Resolution RE252 Wireless Keypad, 345MHz User Manual RE252 Honeywell Compat PIN Pad

Resolution Products, Inc. Wireless Keypad, 345MHz RE252 Honeywell Compat PIN Pad

User Manual

RE252_Honeywell-Compat_PIN-Pad.doc  Page 1 of 4  28-Sep-12 www.ResolutionProducts.com    Wireless  Security  Solutions   RE252 Honeywell Compatible PINpad™  Features  • Secure, 4-digit Code to disarm • 1-button arming • Red/Green LED arming feedback • Small, yet comfortable keypad • Mounts on wall via VHB® tape, or screws • Secure for carrying in purse or mounting on car visor • More securely replaces Honeywell 5878 6-button Wall Touchpad • 4-6 year battery life on CR2032 battery.  Key Instructions • Do NOT use this product for 2GIG panels.  Use the RE252T. • PIN Code programming Default access code is “1234”.  To change access code: 1. Enter current 4-digit access code. 2. Within 4 seconds, press and hold the “1” and “3” keys simultaneously. After 3 seconds, Red LED will be lit. 3. Enter new 4-digit access code. After successfully changing the code, the Green LED will be lit 4. Note new access code .  BAD GUY CANNOT RESET CODE. So it must be noted and remembered! • Enrolling:   1. Refer to the Honeywell control unit installation manual. 2. Enroll exactly as you would a key fob.  • Specific Control Panel Programming follows here…  Lynx Touch 5100:  Programming  Keys  Add New  System Programming… Key Type 4 Button User Master Serial Number [press Stay key to enroll] Zone 49 (example) Button Key 1 – Zn 49 Arm Away Button Key 2 – Zn 50 Disarm Button Key 3 – Zn 51 Arm Stay Button Key 4 – Zn 52 24 Hour Auxiliary  To RF Learn: Press the PINpad STAY button twice, more than 5 seconds apart.   Be at least 5 feet from panel. RE252_Honeywell-Compat_PIN-Pad.doc  Page 2 of 4  28-Sep-12 www.ResolutionProducts.com  Lynx Touch 5100, continued…    Lynx Plus 3000 & Vista:  To RF Learn: Press each PINpad button (or PIN Code) twice, more than 5 seconds apart.   Be at least 5 feet from panel. Be sure to associate the Key with a User!   You may also use WIRELESS KEY TEMPLATE 3.  Operation              2GIG Go! Panel   Use Resolution RE252T 2GIG-Compatible PINpad for 2GIG panels.  Panic function will not work on 2GIG panel using this RE252 Honeywell version. PINpad Button Lynx Touch Button Key Lynx Touch  Loop Should be programmed to Away  Button Key 1  Loop 3  ARM AWAY PIN Code  Button Key 2  Loop 2  DISARM Stay  Button Key 3  Loop 4  ARM STAY Stay + Away  Button Key 4  Loop 1  24 Hour AUX PINpad Button Lynx Plus Zone Number Lynx Plus  Zone Type Lynx Plus  Input Type Lynx Plus  Loop Away  26  (example) 21  Arm-Away  BR  Loop 3 PIN Code  27  22  Disarm  BR  Loop 2 Stay  28  20  Arm-Stay  BR  Loop 4 Stay + Away  29  07  24 Hr Aud  BR  Loop 1 PINpad Button  Panel Action  LED Stay  ARM STAY  flashes double red Away  ARM AWAY  flashes double red twice PIN Code  DISARM  flashes double green Stay + Away  PANIC ALARM  flashes red 8 times
RE252_Honeywell-Compat_PIN-Pad.doc  Page 3 of 4  28-Sep-12 www.ResolutionProducts.com     Pictures                           Battery Replacement CR2032 Battery + Terminal up Insert Screwdriver here to open Stay + Away Sends Panic Loop 1 Entering Code Sends Disarm Loop 2 Away Loop 3 Stay Loop 4 TO CHANGE PIN CODE: Current 4-digit access code, and then… 1 + 3    Red LED,and then… Enter New Code Red/Green  Status LED Shows command sent RE252_Honeywell-Compat_PIN-Pad.doc  Page 4 of 4  28-Sep-12 www.ResolutionProducts.com  Specifications   Not supervised. Replacement Battery:  CR2032 Lithium / Manganese Dioxide Temperature Range:  0F to 120F Housing dimensions:  2x2.25x0.33 inches 1-way RF:      Does not receive panel status  Specifications subject to change without notice.   Notices  “GE”, “Honeywell”, “DSC”, “2GIG” and “Napco” are trademarks owned by General Electric Company, Honeywell International Inc., Tyco Safety Products Canada LTD, 2GIG Technologies Inc., and NAPCO Security Systems, Inc., respectively.    Resolution Products, Inc. products will function with one of either GE, Honeywell, DSC or Napco systems.  However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, Honeywell, DSC or Napco.   Resolution recommends verifying proper enrollment and operation, per control panel installation instructions, at installation.  Warranty Resolution Products, Inc. will replace products that are defective in their first year.  FCC Notice This device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference that may be received, including interference that may cause undesired operation.   Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment.  FCC ID: U5X-RE252   IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and  2. This device must accept any interference, including interference that may cause undesired operation of the device.   Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. Son fonctionnement est soumis aux deux conditions suivantes: 1. Ce dispositif ne peut causer des interférences, et 2. Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.   IC: 8310A-RE252

Navigation menu