Resolution RE261 Wireless Motion Detector User Manual

Resolution Products, Inc. Wireless Motion Detector

User Manual

Download: Resolution RE261 Wireless Motion Detector User Manual
Mirror Download [FCC.gov]Resolution RE261 Wireless Motion Detector User Manual
Document ID3801437
Application IDgvtdDw3Z3M0wlNNSgftf7g==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize54.81kB (685100 bits)
Date Submitted2018-03-29 00:00:00
Date Available2018-03-30 00:00:00
Creation Date2018-03-02 13:19:24
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-03-02 13:19:30
Document TitleUser Manual
Document CreatorAdobe InDesign CC 2017 (Windows)

commercial battery-powered wall mount sensor with an 85
degree detection range.
Features
•
•
•
•
•
85° detection range with 78 distinct detection zones
Range up to 40 feet
Selectable pulse count 2 or 4
Designed for commercial applications
5 year warranty
Enroll all variants by entering their serial numbers into the
security panel. Alternatively, the sensor can be enrolled in
one of the following ways:
Cryptix™, DSC®, Qolsys® and Interlogix® variants are
enrolled by placing the panel into enrollment mode, and
then pulling the battery tab or tampering the device.
Honeywell® and 2GIG™ variants are enrolled by placing
the panel into wireless enrollment mode and either
removing the battery tab while holding the tamper, or by
tripping the device three times. These sensors must be
enrolled as a “Loop 1” sensor.
Install by screwing two #5 screws through the unit’s mounting
knockouts. Use 2 of the 3 mounting knockouts in the center
of the unit’s back to mount on a flat wall. Use 2 of the 4
corner knockouts to mount the unit in the corner of a room.
Mount the sensor 5ft to 8 ft (1.5m-2.4m) high. Screw the
third #8 screw through the wall tamper knockout into the
wall, ensuring that the wall tamper screw is attached to
something solid. Tighten all screws until snug. Enroll the
sensor using the instructions above. Close the cover and
conduct a walk test. After testing, take the unit out of walk
test mode and close the cover again. Finally, finish threading
the white #4 screw until it is snug.
Mounting Tips
• Avoid direct sunlight
• Avoid facing directly to AC or heating vents
• Avoid vapor or high humidity
• Avoid curtains, screens, etc. from blocking detection
• Do not install outdoors
• Mounting height 5ft-8ft (1.5m-2.4m)
Use your panel’s installation guide to verify proper system setup.
UID
IN
PIR Motion Sensor alarms when motion is sensed. It is a
LL
Indoor 40 PIR Motion Sensor
STA
Sensor Functions
Alarm LED can be switched either “ON” or “OFF”.
Pulse Count can be switched to either “2” or “4” pulse
mode depending on the environmental conditions
of the installation.
Pulse Count
• Select “2” for normal applications.
• Select “4” for use in areas where there may be
movement by small animals or other objects,
such as fax machines or curtains.
Walk Test Jumper puts sensor in Walk Test Mode when
connected or Normal Mode when not connected. The
LED will light up and an alarm will be sent whenever
motion is detected if the unit is in Walk Test Mode. In
Normal Mode, the unit will only send an alarm every 2
minutes, and the LED will only light up if the “LED ON”
jumper is connected.
Mounting and Jumper Locations
Detection Range
LED
Pulse Count
Troubleshooting
Problem
Probable Cause
Remedy
Alarm is not activated
although someone is
walking in detection
area
Detection area is improper,
battery is dead, Walk Test
switch is OFF and 2 minute
delay is active
Conduct a walk test, change
the battery
Alarm is activated with
nobody in the area
Moving object within
detection area, temperature
of object within area is
changing rapidly
Remove the object from
the detection area, remove
the heat sources from the
detection area or relocate the
detector
LED does not light up
at the time of the walk
test
Walk test switch is OFF,
battery is dead
Turn the walk test switch ON,
change the battery
LED does not light up
in normal operation
LED switch is OFF, battery
is dead
Turn LED switch ON, change
battery
Pro Tips
Save battery life by taking unit out of walk test mode after
completing walk test. There is no 2 minute delay when
in walk test mode. Leaving in walk test mode will
severely decrease battery life.
Sudden light changes will cause the sensor to trip. Ensure
that the detector is not placed near windows.
Sudden temperature changes will cause the sensor to trip.
Ensure the motion detector is not placed near heating
and cooling vents.
High humidity environments can cause condensation of
the detection lens. Ensure the motion detector is not
installed in these kinds of environments.
Protective film should be removed from the lens after
installation.
Sensor specifications: The table below displays the
functional frequencies of each compatible sensor.
Part Number
Frequency
Compatible
RE161
319.5 MHz
Interlogix/Qolsys
RE261
345 MHz
Honeywell
RE261T
345 MHz
2GIG
RE361
433.92 MHz
DSC
RE661
433.92 MHz
Cryptix
Specifications
Physical
Housing Dimensions
4.53 x 2.44 x 1.97 inches (115 x 62 x 50 mm)
Weight with Battery
3.9oz (110.6 g)
Mounting Fasteners
(2) #5 screws, (1) #8 screw (1) square nut, (1) #4 screw
(All provided)
Environmental
Operating Temperature
Maximum Humidity
32°F to 120°F (0°C to 49°C)
85% non-condensing relative humidity
Sensor Specifications
Frequencies
Replacement Battery
Nominal Battery Life
433.92 MHz, 319.5 MHz, 345 MHz
One Panasonic CR123A Lithium Battery
3 years (assuming 720 trips/day), 7 years (assuming 240 trips/
day)
Battery Voltage
Current Draw
Detection Range
Detectable Speed
Transmitted Indications
3.0 VDC (Nominal), 2.7 VDC (Low)
21 mA (Maximum), 4.7 uA (Standby), 30 mA (Max in walk
test)Up to 40 Feet (12 m)
1 to 5 feet per second (0.3 to 1.5 meters per second)
Motion, Tamper (Cover/Wall), Low Battery, Supervision
Certification
RE161, RE261, RE261T,
RE361, RE661
UL639, ULC-S306-03, ETL, FCC, IC
Specifications subject to change without notice
FCC NOTICE
WARRANTY
Resolution Products, Inc. will replace all non-portable products
that are defective in their first five (5) years, and all portable
products that are defective in their first two (2) years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including
interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux cnr d’Industrie
Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
IC: 8310A-RE161, 8310A-RE261, 8310A-RE361
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by Resolution
Products, Inc. could void the user’s authority to operate this
equipment.
FCC ID: U5X-RE161, U5X-RE261, U5X-RE361
TRADEMARKS
INTERLOGIX, HONEYWELL, DSC, QOLSYS, AND 2GIG
ARE TRADEMARKS OWNED BY UNITED TECHNOLOGIES
ELECTRONIC CONTROLS INC., HONEYWELL INTERNATIONAL
INC., TYCO SAFETY PRODUCTS CANADA LTD, QOLSYS
INC. AND 2GIG, RESPECTIVELY. RESOLUTION PRODUCTS,
INC. PRODUCTS WILL FUNCTION WITH ONE OF EITHER
INTERLOGIX (FORMERLY GE), QOLSYS, HONEYWELL, DSC, OR
2GIG SYSTEMS. HOWEVER, NO RESOLUTION PRODUCT IS
PRODUCED BY, ENDORSED BY, NOR IS OFFICIALLY ASSOCIATED
WITH INTERLOGIX (FORMERLY GE), QOLSYS, HONEYWELL, DSC
OR 2GIG. RESOLUTION RECOMMENDS VERIFYING PROPER
ENROLLMENT AND OPERATION, PER CONTROL PANEL
INSTALLATION INSTRUCTIONS, AT INSTALLATION.
47-0050-00 • RevA • 2018-03-02
Tech Support Line (877) 260-5578
www.ResolutionProducts.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01
Create Date                     : 2018:03:02 13:19:24-06:00
Metadata Date                   : 2018:03:02 13:19:30-06:00
Modify Date                     : 2018:03:02 13:19:30-06:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Instance ID                     : uuid:86d27344-7702-4409-9c5c-a0e9f2c69193
Original Document ID            : xmp.did:4f265460-22e0-4d44-80b2-09089cdf40a5
Document ID                     : xmp.id:68778747-cf10-c644-8eaf-af92c778b08e
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6fbedec8-2566-c645-a99a-d9a926ac6d01
Derived From Document ID        : xmp.did:9c96f17e-3439-434d-ac1c-5b8c73615382
Derived From Original Document ID: xmp.did:4f265460-22e0-4d44-80b2-09089cdf40a5
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2018:03:02 13:19:24-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CC 2017 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U5X-RE261

Navigation menu