Resolution RE301 Security Transmitter, 433.92MHz User Manual RE301 DSC Compat DWS Instructions
Resolution Products, Inc. Security Transmitter, 433.92MHz RE301 DSC Compat DWS Instructions
User Manual
Wireless Security Solutions RE301 DSC-Compatible Standard Door / Window Features • For sensing things that open or separate. • 3 total zones. Each with separate ESNs. o Main reed switch + magnet o 2 supplemental hardwire zones Outer terminal. Inner terminal. • Cover tamper. • Strong, reliable RF signal. • 10-15 year battery life on CR123A battery. • Low Battery indication. Key Instructions • Battery “+” faces towards spring. • DWS has 3 zones with 3 ESNs. But when it comes from the factory, only the magnetic reed switch reports to the panel. The other two external contact zones must be “activated” in order to report. • External contact zones are: normally closed – alarm on open. • No end-of-line resistors on external contact zones. • Activating Zones – ACTIVATE ONLY THE ZONES YOU NEED: Reed switch Zone 0: ESN ends in “0” and is labeled on the DWS battery bucket. Comes from factory already activated. External Contact Zone 1: Outer terminal + Center Terminal ESN is same as Reed switch, except it ends in “1” Activate by shorting Zone 1 while installing battery. External Contact Zone 2: Inner terminal + Center Terminal ESN is same as Reed switch, except it ends in “2” Activate by shorting Zone 2 while installing battery. • Enrolling Zones in DSC Panel: Put panel in Wireless Enrollment Mode. Set all active zones on the DWS to NON-Alarm state. Open (alarm) only the zone on the DWS that you want to enroll. Confirm ESN, Enter Zone # and Zone Type on DSC Panel. May also be enrolled via entering ESN. RE301_DSC-Compat_DWS_Instructions.doc Page 1 of 3 7/22/2011 www.ResolutionProducts.com Operation • Magnetic reed switch (ESN “0”): Alarm, when magnet is pulled away from reed switch. • External Contact zones (Outer=ESN “1”, Inner=ESN “2”) Each zone functions ONLY if Activated AND Enrolled in panel. Alarm: when contact opens. Zones function independently and send separate ESN signals. • Tamper reports on each and every active zone, when cover is opened. • Supervisory signals sent for each and every active zone, every hour. Specifications Magnet trip distance: Mounting hardware: Replacement Battery: Temperature Range: Housing dimensions: 1 inch nominal # 4 or #6 screws CR123A 1550mAH 0F to 120F 3.3x1.4x1.1 inches Specifications subject to change without notice. Internal Picture Tamper ESN ending in “2” Inner Terminal Zone Activated by loop being shorted during power-up Center Common Terminal ESN ending in “0” Magnetic Reed Switch Comes from factory active ESN ending in “1” Outer Terminal Zone Activated by loop being shorted during power-up RE301_DSC-Compat_DWS_Instructions.doc Page 2 of 3 7/22/2011 www.ResolutionProducts.com Notices “GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell International Inc., and Tyco Safety Products Canada LTD, respectively. Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems. However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, Honeywell or DSC. Resolution recommends verifying proper enrollment and operation, per control panel installation instructions, at installation. Warranty Resolution Products, Inc. will replace products that are defective in their first year. FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment. FCC ID: U5X-RE301 IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. Son fonctionnement est soumis aux deux conditions suivantes: 1. Ce dispositif ne peut causer des interférences, et 2. Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. IC: 8310A-RE301 RE301_DSC-Compat_DWS_Instructions.doc Page 3 of 3 7/22/2011 www.ResolutionProducts.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : a781defc-b6ec-11e0-0000-e6d7ff05e350 Producer : GPL Ghostscript 8.64 Keywords : () Modify Date : 2011:07:22 13:33:41-05:00 Create Date : 2011:07:22 13:33:41-05:00 Creator Tool : \376\377\000P\000D\000F\000C\000r\000e\000a\000t\000o\000r\000 \000V\000e\000r\000s\000i\000o\000n\000 \0000\000.\0009\000.\0008 Document ID : a781defc-b6ec-11e0-0000-e6d7ff05e350 Format : application/pdf Title : \376\377\000R\000E\0003\0000\0001\000_\000D\000S\000C\000-\000C\000o\000m\000p\000a\000t\000_\000D\000W\000S\000_\000I\000n\000s\000t\000r\000u\000c\000t\000i\000o\000n\000s Creator : \376\377\000b\000s\000e\000e\000m\000a\000n\000n Description : () Author : bseemann Subject :EXIF Metadata provided by EXIF.tools