Resolution RE308 8 Zone Transmitter, 433.92MHz User Manual RE308 Hardwire to DSC Compat Translator

Resolution Products, Inc. 8 Zone Transmitter, 433.92MHz RE308 Hardwire to DSC Compat Translator

User Manual

RE308_Hardwire_to_DSC-Compat_Translator.doc Page 1 of 4  8/2/2011 www.ResolutionProducts.com   Wireless  Security  Solutions   RE308  Hardwire to Wireless Takeover Translator™, DSC-Compatible  Features • Converts hardwire zones into DSC-compatible wireless signals. • 8 Hardwire loops with end-of-line resistor detection. • Unique wireless ESN for each Translator loop, plus 1 for main device. • Transmit diversity for long reliable range. • PIR powering (via external supply). • 3 year operation on batteries (contacts only). • Complete supervision of zone tampers and low battery.  Key Instructions • Translator is for use with DSC Self Contained and Alexor systems that have “Wireless Enrollment Mode”.   If using the Translator with an earlier DSC System, please call Resolution Tech Support, and we will help you determine the IDs to plug in. • Use with normally closed contacts in-line with 4.7 K-ohms end-of-line resistors. • Not for use with life safety devices, such as Smoke or CO sensors. • External supply requirements (wall-AC):  12V DC at least 50 mA. • PIR & Glassbreak (powered devices) usage:    4-wire devices only.  Not for use with 2-wire powered devices.  2 AA back-up batteries will drive contacts only, and cannot drive a PIR.  Under external supply failure, the PIR/Glass would likely alarm.  If using PIR/Glass, we recommend using 12V DC, 24-hour back-up supply.  If using old panel 12V DC supply, verify operation and old battery. • Enrolling:  Sensor enrollment: 1. Enter Wireless Enrollment Mode on DSC Panel. 2. Open each loop to initiate enrollment. 3. Confirm ESN,  Enter Zone # and Zone Type on DSC panel.  Main Translator device enrolled into panel by its tamper switch.   Zone Type 03 will monitor Tamper, Low Battery and Supervisions.  Operation • 8 Hardwire 4.7K-ohm Zones – transmit 8 unique wireless IDs: Alarm, when Device sees open circuit. Tamper, when device sees short circuit. Supervisories, every hour for each zone.  RE308_Hardwire_to_DSC-Compat_Translator.doc Page 2 of 4  8/2/2011 www.ResolutionProducts.com • Translator Main Zone wireless transmission (9th unique ID): Tamper, when cover opened. Low battery, when either low AA batteries, OR loss of 12V DC external. Supervisory every hour.  • LED Operation Green LED:  On if AC power present. Red LED:  When 12V DC is present: “Blinks” on transmit to panel; “on” if device tamper or device low battery. • Application Diagram                        • Connection Diagram    New Wireless System  Existing Hardwire Sensors  New  Self-Contained System in public area  Old Hardwire Panel Mounted in utility area New System’s wireless language  4.7KContactClosed NormallyOpen in AlarmLoopxPIRTo Enroll zone, short across here to tamper12V DC AA Backup batteries will NOT power PIR
RE308_Hardwire_to_DSC-Compat_Translator.doc Page 3 of 4  8/2/2011 www.ResolutionProducts.com   Specifications DSC Device Type:  2  (all 8 zone ESN’s and device ID) Electronic Serial Numbers:    Last digit = Translator Loop #  [0 = Module] Zone sensing duration:    State sensed if held more than 600ms. End-of-line Resistors:  4.7k-ohm, 5%. Max wire run:    1000 feet Backup batteries:  Two AA Alkaline. External supply:    12V DC, at least 50mA. Current draw with supply: 4mA, normal operation. PIR usage:    PIR may need tight voltage tolerance.  Add PIR and device current requirements together to get total current need.   AC Fail Conditions:  External 12VDC gone for 15 minutes.  Restores on external 12VDC restore. Device Low Battery Conditions:  Low battery for 1 minute.  Restores on device tamper, external 12VDC restore. Back-up Battery Life on AC Fail:   2 years, all zones terminated in 4.7K; longer if unused/open. Housing dimensions:  4x6x1 inches  Specifications subject to change without notice.  Internal Picture   Terminals for Zones 1, 2 Terminals for Zones 3-8 Power Terminals Tamper / Enroll Switch RE308_Hardwire_to_DSC-Compat_Translator.doc Page 4 of 4  8/2/2011 www.ResolutionProducts.com Notices  “GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell International Inc., and Tyco Safety Products Canada LTD, respectively.    Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems.  However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, Honeywell or DSC.   Resolution recommends verifying operation at installation.  Do not use Translator for life safety devices, such as smoke or CO sensors.  Warranty Resolution Products, Inc. will replace products that are defective in their first year.  FCC Notice This device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference that may be received, including interference that may cause undesired operation.   Changes or modifications not expressly approved by the Resolution Engineering, Inc. could void the user's authority to operate this equipment.  FCC ID: U5X-RE308   IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and  2. This device must accept any interference, including interference that may cause undesired operation of the device.   Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. Son fonctionnement est soumis aux deux conditions suivantes: 1. Ce dispositif ne peut causer des interférences, et 2. Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.    IC: 8310A-RE308

Navigation menu