Resolution RE920 IP Module User Manual 1 of 2

Resolution Products, Inc. IP Module 1 of 2

Contents

User manual 1 of 2

RE920 PA IP ModuleFeatures•Connects in daughterboard slot of SimonXT panel•Allows reporting of alarm and status conditions over IP connection•Allows control of system functions (arming, disarming, etc) over IP connection•Allows control of lights and other Zwave devices over IP connectionKey Instructions•Install RE920 unit in slot at back of panel•Power up the panel•Connect ethernet cable•Connect to configuration software and enter MAC address•Configure RE920 to correct IP address for reporting•Configure RE920 to correct IP address for system controlLED Operation•"L and S" LEDs are normal ethernet LEDs and indicate healthy ethernet network connection•"Power" LED lights green when powered and shows heartbeat for processor functioning correctly•"Local" LED lights when proper connection to local router established•"CS" LED lights when connected to Central Station•"Platform" LED lights when connected to interactive platform websiteRE920_IP_Module_Manual.docPage 1 of 407-Jan-11www.ResolutionProducts.com
SpecificationsPanel Compatibility: GE/Interlogix SimonXTExternal supply:   9-18V DC, at least 100mA.Current draw: 60mA, normal operation.PCB dimensions: 1.9 x 4.1 inchesSpecifications subject to change without notice.Internal PictureRE920_IP_Module_Manual.docPage 2 of 407-Jan-11www.ResolutionProducts.comEthernet LEDsEthernet ConnectorFactory Default SwitchStatus LEDsPrinted Zwave AntennaMounting Holes
OEM Installation InstructionsThe RE920 module is installed in the SimonXT host as follows:1. The SimonXT should be powered down.2. Expose the back of the panel as shown in the following picture.3. The module is installed in the expansion slot on the left, as shown in the picture.4. Unwrap the module from its packaging and carefully slide the module underneath the plastic tabs at the top of the expansion slot.5. Gently press down on the bottom of the module so that it engages with the connector on the panel.6. Secure the module in place using four screws in the provided holes.7. Attach ethernet cable to the connector and arrange it so that it exits the enclosure with out strain.8. Connect to the module using the configuration IP Address and configure the module's IP Addresses and other information with the configuration interface.RE920_IP_Module_Manual.docPage 3 of 407-Jan-11www.ResolutionProducts.com
Notices “GE” is a trademark owned by General Electric Company.  "Interlogix" is a trademark of UTC.This Resolution product is not produced by, endorsed by, or officially associated with GE or UTC.   Resolution recommends verifying operation at installation.This product is only usable with the GE/Interlogix SimonXT alarm panel.FCC NoticeThis device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions:This device may not cause harmful interference.This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Engineering, Inc. could void the user's authority to operate this equipment.FCC ID: U5X-RE920RE920_IP_Module_Manual.docPage 4 of 407-Jan-11www.ResolutionProducts.com

Navigation menu