Rheem Classic Series Up To 95 Afue 2 Stage Psc Motor Submittal Sheet

2015-04-02

: Rheem Rheem-Classic-Series-Up-To-95-Afue-2-Stage-Psc-Motor-Submittal-Sheet-683819 rheem-classic-series-up-to-95-afue-2-stage-psc-motor-submittal-sheet-683819 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 3

SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
FORM NO. X33-1371
Supersedes Form No. X33-1229 Rev. 4
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
SUBMITTAL SHEET FOR RGRL-
95% A.F.U.E. OR ABOVE TWO-STAGE
UPFLOW GAS FURNACES
Models with Input Rates of 45,000, 60,000, 75,000, 90,000
& 105,000 BTU/HR [13.19, 17.58, 22, 26.38 & 30.77 kW]
UNIT DATA
HEATING PERFORMANCE
TOTALCAPACITY INPUT* ...... _______ MBH [kW]
TOTAL CAPACITY OUTPUT* .. _______ MBH [kW]
DESIGN TEMP. RISE .............. _______ °F [°C] DB
AFUE ................................................ _______ %
CALIFORNIA SEASONAL
EFFICIENCY .................................. _______ %
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................ _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT...................................... _______ IWG
BLOWER SPEED .......................... _______ RPM
POWER OUTPUT REQUIREMENT .. _______ BHP
MOTOR RATING ........................ _______ HP [W]
POWER INPUT REQUIREMENT ........ _______ kW
ELECTRICAL DATA
POWER SUPPLY .............................. _______ Hz
TOTAL UNIT AMPACITY................ _______ AMPS
MINIMUM WIRE SIZE .................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER .......... _______ AMPS
FEATURES FOR RGRL
Two stages of operation to save energy and maintain optimal
comfort level.
Furnace operates at 70% capacity for low-heat and 100% capacity
for high-heat.
Compatible with single or two-stage thermostat. (For optimal perfor-
mance a two-stage thermostat is recommended.)
Heat exchanger is constructed of all aluminized steel for maximum
corrosion resistance and thermal fatigue reliability.
Low profile “34 inch” design is lighter and easier to handle and
leaves room for optional accessories.
Left or right side gas, electric, and condensate drainage connections.
Integrated control board manages all operational functions and
provides hookups for humidifier and electronic air cleaner.
An insulated blower compartment, a slow-opening gas valve and a
specially designed inducer system make it one of the quietest
furnaces on the market today.
Features a Limited Lifetime Warranty on the primary and secon dary
heat exchanger and a 10-Year Limited Warranty on all other parts.
Molded permanent filters.
Optional indoor or outdoor combustion air. In addition, combustion
air may be piped to either the top or side of the cabinet on all upflow
models. A special molded fitting is provided to ease installation.
Dual certified for sealed combustion (2-pipe) or non-direct (1-pipe)
applications.
Solid bottom is standard.
Control board diagnostics.
FIELD INSTALLED ACCESSORIES
Plenum Adapter (RXAA-) ....................................................................
Vent Termination Kits Concentric:
RXGY-E03A Vertical/Horizontal: RXGY-E03A ..............................
RXGY-D02 OR 2A RXGY-003 OR 3A
Horizontal Two Pipe: RXGY-D02, RXGY-D03 ..........................
Condensate Pump Kit: RXGY-B01 ......................................................
Neutralizer Kit: RXGY-A01............................................................
Fossil Fuel Kit: RXPF-F01 and F02 ....................................................
Return Air Plenum (RXGR-C17B, 21B, 24B) ......................................
External Bottom Filter Rack: RXGF-CB ..............................................
External Side Filter Rack: RXGF-CA ..................................................
High Altitude Kit: (RXGY-F18, F19, F20)..............................................
UPFLOW MODELS
MODEL
RGRL- A B C D E F LEFT
SIDE
MINIMUM CLEARANCE (IN.) [mm] SHIP
WGTS.
[kg]
RIGHT
SIDE BACK TOP FRONT VENT
04*MAES 171/2[445] 1611/32 [415] 155/8[397] 2 [51] 15 [422] 1325/32 [352] 0 0 0 1 [25] 2 [51] 0111 [50]
06*MAES 171/2[445] 1611/32 [415] 155/8[397] 2 [51] 15 [422] 1325/32 [352] 0 0 0 1 [25] 2 [51] 0117 [53]
09*ZAJS 21 [533] 1927/32 [504] 191/8[487] 2 [51] 181/2[511] 179/32 [441] 0 0 0 1 [25] 2 [51] 0148 [67]
07*YBGS 21 [533] 1927/32 [504] 191/8[487] 2 [51] 181/2[511] 179/32 [441] 0 0 0 1 [25] 2 [51] 0145 [66]
07*MAES 171/2[445] 1611/32 [415] 155/8[397] 2 [51] 15 [422] 1325/32 [352] 0 0 0 1 [25] 2 [51] 0123 [56]
10*ZAJS 21 [533] 1927/32 [504] 191/8[487] 2 [51] 181/2[511] 179/32 [441] 0 0 0 1 [25] 2 [51] 0152 [69]
*E=Standard [ ] Designates Metric Conversions
*N=NOxModels
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices. Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. 4-12 QG FORM NO. X33-1371
Supersedes Form No. X33-1229 Rev. 4