Rheem Classic Series Up To 95 Afue 2 Stage V S Ecm Specification Sheet
2015-04-02
: Rheem Rheem-Classic-Series-Up-To-95-Afue-2-Stage-V-S-Ecm-Specification-Sheet-683834 rheem-classic-series-up-to-95-afue-2-stage-v-s-ecm-specification-sheet-683834 rheem pdf
Open the PDF directly: View PDF
.
Page Count: 12
| Download | |
| Open PDF In Browser | View PDF |
Air Gas Furnaces RGRM Series Rheem Classic® Series Two-Stage Upflow Gas Furnaces RGRM- Series 45K through 105K Models Rated at 95% A.F.U.E.†, 120K Model Rated at 93.3% A.F.U.E.† Input Rates of 45, 60, 75, 90, 105 & 120 kBTU [13.19-35.17 kW] With Dual Comfort Control™ “The RGRM- 12 gas furnace has earned the ENERGY STAR® in all U.S. South States.” ✝ A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. • The Rheem Classic ® Series 95% A.F.U.E. with Dual Comfort Control™ line of upflow gas furnaces are designed for utility rooms, closets, alcoves, or attics. Because of the low-profile 34 inch [864 mm] height, the upflow model can also be used to satisfy most applications. The design is certified by CSA. • Two stages of operation to save energy and maintain optimal comfort level. • Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat. • Compatible with single or two-stage thermostat. (For optimal performance a two-stage thermostat is recommended.) • Heat exchanger is constructed aluminized steel for maximum corrosion resistance and thermal fatigue reliability. • Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories. • Left or right side gas, electric, and condensate drainage connections. • Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner. • An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. • Variable speed blower motor technology provides ultimate humidity control, quieter sound levels and year-round energy savings. • Optional indoor or outdoor combustion air. In addition, combustion air may be piped to either the top or side of the cabinet on all upflow models. A special molded fitting is provided to ease installation. • Solid bottom is standard. • Control board diagnostics. • A variety of cooling coils and plenums designed to use with the Rheem Classic ® Series 95% A.F.U.E. gas furnaces are available as optional accessories for air conditioning models. FORM NO. G11-523 Air Table of Contents RGRM Series TABLE OF CONTENTS Standard & Optional Equipment ......................................................................3 Physical Data & Specifications ........................................................................4 Model Number Identification ............................................................................5 Dimensional Data............................................................................................6 Blower Performance Data ................................................................................7 Accessories....................................................................................................8 Limited Warranty ............................................................................................9 2 Air Standard & Optional Equipment RGRM Series REMOTE SENSOR DIRECT SPARK IGNITION & REMOTE SENSOR PRIMARY AND SECONDARY HEAT EXCHANGER GAS VALVE AND MANIFOLD IN-SHOT BURNERS PRESSURE SWITCHES DRAFT INDUCER INTEGRATED FURNACE CONTROL ECM MOTOR STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired; heat exchanger; primary aluminized steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; pressure regulator for natural and L.P. (propane) gasses; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.) Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 3 Air Physical Data & Specifications RGRM Series Physical Data and Specifications—Upflow Models U.S. and Canadian Models MODEL NUMBERS HIGH FIRE INPUT BTU/HR [kW] ➀ LOW FIRE INPUT BTU/HR [kW] ➁ HEATING CAPACITY BTU/HR [kW] HIGH ALTITUDE INPUT 8000' ➁ HIGH ALTITUDE OUTPUT AT 8000' (HIGH FIRE) [kW] ➁ BLOWER (D x W) [mm] MOTOR H.P. [W]– SPEEDS–TYPE RGRM-04*MAES RGRM-06*MAES RGRM-07*MAES RGRM-07*YBGS RGRM-09*ZAJS** RGRM-10*ZAJS** RGRM-12*RAJS 45,000 [13.19] 60,000 [17.58] 75,000 [21.98] 75,000 [21.98] 90,000 [26.38] 105,000 [30.77] 120,000 [35.17] 31,500 [9.23] 42,000 [12.31] 52,500 [15.39] 52,500 [15.39] 63,000 [18.46] 73,500 [21.54] 84,000 [24.62] 42,000 [12.31] 56,000 [16.41] 70,000 [20.51] 70,000 [20.51] 84,000 [24.62] 97,000 [28.43] 113,000 [33.12] 30,600 [8.97] 40,800 [11.96] 51,000 [14.95] 51,000 [14.95] 61,200 [17.94] 71,400 [20.93] 81,600 [23.91] 28,458 [8.34] 37,944 [11.12] 47,430 [13.90] 47,430 [13.90] 56,916 [16.69] 66,402 [19.46] 75,888 [22.24] 11 x 7 [279 x 178] 1/2 [373] VAR. SPEED 11 x 7 [279 x 178] 1/2 [373] VAR. SPEED 11 x 7 [279 x 178] 1/2 [373] VAR. SPEED 12 x 7 [305 x 178] 1 [746] VAR. SPEED 12 x 11** [305 x 279] 1 [746] VAR. SPEED 12 x 11** [305 x 279] 1 [746] VAR. SPEED 11 x 10 [279 x 254] 1 [746] VAR. SPEED MOTOR FULL LOAD AMPS 8.7 8.7 8.7 12 12 12 12 MINIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .10 [0.25] .12 [.029] .12 [.029] .12 [.029] .15 [.037] .20 [.049] .20 [.049] MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2] 850 725 765 1180 1275 1400 1250 780 900 1080 1180 1450 1604 1450 TEMPERATURE RISE-HIGH FIRE RANGE IN DEGREES °F [°C] A = 1200 B = 1000 C = 800 D = 600 A = 900 B = 750 C = 600 D = 450 30-60 [16.7-33.3] A = 1200 B = 1000 C = 800 D = 600 A = 900 B = 750 C = 600 D = 450 40-70 [22.2-38.9] A = 1200 B = 1000 C = 800 D = 600 A = 900 B = 750 C = 600 D = 450 40-70 [22.2-38.9] A = 1600 B = 1400 C = 1200 D = 1000 A = 1200 B = 1050 C = 900 D = 750 35-65 [19.4-36.1] A = 2000/900 B = 1600 C = 1400 D = 1200 A = 1500 B = 1200 C = 1050 D = 900 35-65 [19.4-36.1] A = 2000/800 B = 1600 C = 1400 D = 1200 A = 1500 B = 1200 C = 1050 D = 900 40-70 [22.2-38.9] A = 2000 B = 1600 C = 1400 D = 1200 A = 1500 B = 1200 C = 1050 D = 900 50-80 [27.8-4.4] TEMPERATURE RISE-LOW FIRE RANGE IN DEGREES °F [°C] 15-45 [8.3-25] 35-65 [19.4-36.1] 35-65 [19.4-36.1] 20-50 [11.1-27.8] 25-55 [13.9-30.6] 30-60 [16.7-33.3] 40-70 [22.2 – 38.9] 160 170 180 170 165 180 180 C17B (2) 12" x 16" [305 x 406] C17B (2) 12" x 16" [305 x 406] C17B (2) 12" x 16" [305 x 406] C21B (2) 12" x 20" [305 x 508] C21B (2) 12" x 20" [305 x 508] C21B (2) 12" x 20" [305 x 508] C24B (2) 14" x 16" [609 x 406] 153/4 x 25 x 1 153/4 x 25 x 1 153/4 x 25 x 1 153/4 x 25 x 1 191/4 x 25 x 1 191/4 x 25 x 1 223/4 x 25 x 1 117 [53.2] 95.0% 123 [56.0] 95.0% 128 [58.2] 95.0% 139 [63.2] 95.0% 148 [67.3] 95.0% 150 [68.2] 95.0% 159 [72.3] 93.3% LOW HEATING CFM @ .2" [.049 kPa] W.C. E.S.P. [L/s] HIGH HEATING CFM @ .2" [.049 kPa] W.C. E.S.P. [L/s] HIGH COOLING CFM @ .8" [.124 kPa] W.C. E.S.P. [L/s] LOW COOLING CFM @ .8" [.124 kPa] W.C. E.S.P. [L/s] MAX. OUTLET AIR TEMPERATURE RETURN AIR CABINETS (OPT.) RXGRFILTER SIZE [mm] STANDARD, HIGH VELOCITY PERMANENT FILTER (IN.) APPROX. SHIPPING WEIGHT (LBS.) [kg] AFUE ➂ NOTES: All models are 115V, 60HZ, 1 phase. Gas connection size for all models is 1/2" [13 mm] N.P.T. ➀ See Conversion Kit Index Form for high altitude derate. ➁ Canadian installations only. ➂ In accordance with D.O.E. test procedures. *E=Standard *N=NOx Models **12 x 11 Housing, 11 x 10 Wheel [ ] Designates Metric Conversions 4 WARNING: Some heating airflow values may be higher than those required for cooling. Be sure to size duct systems for highest possible airflow value. Air Model Number Identification RGRM Series Model Number Identification R Rheem G R M — Gas Upflow Design Furnace Condensing Series Gas Furnace 07E* Heating Input Designation Y Blower Size M = 11 x 7 [279 x 178 mm] R = 11 x 10 Input Electric [279 x 254 mm] Ignition BTU/HR Z = 12 x 11** 04* 45,000 [13.19 kW] [305 x 279 mm] 06* 60,000 [17.58 kW] Y = 12 x 7 07* 75,000 [22 kW] [305 x 178 mm] 09* 90,000 [26.38 kW] 10* 105,000 [30.77 kW] 12* 120,000 [35.17 kW] NOTES: *E = Standard *N = NOx Models **12 x 11 Housing, 11 x 10 Wheel B G Variations A = Std. B = Wide Heat/Cool Designation E = 1100-1300 CFM [519-613.5 L/s] G = 1500-1700 CFM [707.9-802.3 L/s] J = 1900-2100 CFM [896.7-991.1 L/s] RGRM-04EMAES RGRM-04NMAES RGRM-04EMAES278 RGRM-06EMAES RGRM-06NMAES RGRM-06EMAES278 S 278** Fuel Code S = U.S. and Canadian Available Models: RGRM-07EMAES RGRM-07NMAES RGRM-07EYBGS RGRM-07NYBGS RGRM-09EZAJS** RGRM-09NZAJS** Option Code for High Altitude RGRM-09EZAJS278** RGRM-10EZAJS** RGRM-10NZAJS** RGRM-12ERAJS RGRM-12NRAJS RGRM-12ERAJS78 [ ] Designates Metric Conversions 5 Air Dimensional Data RGRM Series MODEL RGRM- A B C D E F LEFT SIDE 04*M 06*M 07*M 07*Y 09*Z 10*Z 12*R 17.5 [445] 17.5 [445] 17.5 [445] 21 [533] 21 [533] 21 [533] 24.5 [622] 1611/32 [415] 1611/32 [415] 1611/32 [415] 1927/32 [504] 1927/32 [504] 1927/32 [504] 2311/32 [593] 155/8 [397] 155/8 [397] 155/8 [397] 191/8 [487] 191/8 [487] 191/8 [487] 225/8 [575] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 151/2 [422] 151/2 [422] 151/2 [422] 181/2 [511] 181/2 [511] 181/2 [511] 221/2 [600] 1325/32 [352] 1325/32 [352] 1325/32 [352] 179/322 [441] 179/322 [441] 179/322 [441] 2025/32 [530] 0 0 0 0 0 0 0 * E=Standard * N=NOx [ ] Designates Metric Conversions 6 MINIMUM CLEARANCE (IN.) [mm] RIGHT BACK TOP FRONT VENT SIDE 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 Air MODEL RGRM- BLOWER SIZE (D x W) IN. [mm] ECM MOTOR H.P. [W] RGRM-04*M 11 x 7 [279 x 178] 1/2 [373] RGRM-06*M 11 x 7 [279 x 178] 1/2 [373] RGRM-07*M 11 x 7 [279 x 178] 1/2 [373] RGRM-07*Y 12 x 7 [305 x 279] 1 [746] RGRM-09*Z** 12 x 11** [305 x 279] 1 [746] RGRM-10*Z** 12 x 11** [305 x 279] 1 [746] RGRM-12*R 11x 10 [279 x 254] 1 [746] BLOWER SPEED HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW Blower Performance Data RGRM Series CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa] 0.1 [.02] – 0.8 [.20] 1200 [566] 1000 [472] 800 [378] 600 [283] 1200 [566] 1000 [472] 800 [378] 600 [283] 1200 [566] 1000 [472] 800 [378] 600 [283] 1600 [755] 1400 [661] 1200 [566] 1000 [472] 1900 [887] 1600 [755] 1400 [661] 1200 [566] 1800 [850] 1600 [755] 1400 [661] 1200 [566] 2000 [944] 1600 [755] 1400 [661] 1200 [566] *E=Standard *N=NOx Models NOTE: CFM values represent furnace-only airflow ratings. **12 x 11 Housing, 11 x 10 Wheel [ ] Designates Metric Conversions 7 Accessories RGRM Series Air VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/VERTICAL = RXGY-E03A (US & Canadian Installations) HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04 (US Installations) RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations) RXGY-G02 (US Only) CONDENSATE PUMP KIT: RXGY-B01 NEUTRALIZER KIT: RXGY-A01 FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA) RETURN AIR PLENUM: RXGR-C17B, RXGR-C21B, RXGR-C24B PLENUM DATA FOR “A” COILS Plenum adapters are required in some instances for use on upflow applications when plenum and furnace size do not match. FURNACE WIDTH IN. [mm] 141/2 [356] 141/2 [356] PLENUM WIDTH IN. [mm] 161/4 [413] 201/4 [514] 171/2 [445] 171/2 [445] 171/2 [445] PLENUM ADAPTER UPFLOW COIL PLENUM RXAA-C171 RXAL-B16BU RXAA-C172 RXAL-B20BU 161/4 [413] 201/4 [514] 215/8 [549] RXAA-C185 RXAA-C173 RXAA-C187 RXAL-B16BU RXAL-B20BU RXAL-B21BU 171/2 [445] 251/4 [641] RXAA-C174 RXAL-B25BU 21 21 21 251/4 [641] 221/4 [565] 215/8 [549] RXAA-C175 RXAA-C176 RXAA-C188 RXAL-B25BU RXAL-B22BU RXAL-B21BU ® 1/2 [622] 1/4 [641] for MultiFlex RXAA-C177 24See 25C11-206 Note: Form Number coil data. 241/2 [622] 215/8 [549] RXAA-C187 RXAL-B25BU RXAL-B21BU [533] [533] [533] LP CONVERSION KITS: U.S./Canadian RXGJ-FP26 or RXGJ-FP21 EXTERNAL BOTTOM FILTER RACK: RXGF-CB EXTERNAL SIDE FILTER RACK: RXGF-CA MODEL RGRM04 06 07EM 07NM 07EY 07NY 09 10 12 FILTER RACK FILTER SIZES* INCHES [mm] RXGF-CB RXGF-CA (BOTTOM) (SIDE) 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 223/4 x 25 [578 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. [ ] Designates Metric Conversions 8 FOR HIGH ALTITUDES: HIGH ALTITUDE KIT: INPUT BTU/HR [kW] RGRM-04*M HIGH ALTITUDE KIT NO. RXGY-F18 RGRM-06*M RXGY-F18 RGRM-07*M RGRM-07*Y Not Required Not Required RGRM-09*Z RXGY-F20 RGRM-10*Z RGRM-12*R Not Required RXGY-F21 Option – 278 furnaces are shipped with #51 DMS orifices installed. This is one drill size smaller than standard furnaces to account for expected average elevations and heating values typically seen in these areas. CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. For all installations above 2000 ft. (including all option – 278 models), the burner orifice size needs to be recalculated and verified. A burner orifice change may still be required. See Installation Instructions for more information. NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. (U.S. Models—Kit packaged with furnace. Requires field installation). Air Limited Warranty RGRM Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Unit Replacement (Registration Required) ...............................Ten (10) Years Conditional Parts (Registration Required) ...............................Ten (10) Years Heat Exchanger .........................................Limited Lifetime 9 Air 10 Notes RGRM Series Air Notes RGRM Series 11 The new degree of comfort.™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 PRINTED IN U.S.A 05/12 QG FORM NO. G11-523
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Has XFA : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 10.1.3 (Macintosh) Create Date : 2012:05:07 12:24:19-05:00 Modify Date : 2012:05:11 11:54:10-05:00 Title : untitled Page Count : 12EXIF Metadata provided by EXIF.tools