Rheem Commercial Storage Tanks80 115 175 Gallon Users Manual RR102C 3
115 to the manual 94e8fe0a-1f61-4744-25c4-af144916cabd
2015-02-05
: Rheem Rheem-Commercial-Storage-Tanks80-115-175-Gallon-Users-Manual-358379 rheem-commercial-storage-tanks80-115-175-gallon-users-manual-358379 rheem pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Commercial Storage Tanks Available in 80, 115 and 175 Gallon Models Rheem-Ruud commercial storage tanks are vertical tanks designed for applications that require large quantities of hot water in short periods of time. When used in tandem with Rheem-Ruud commercial water heating equipment, these storage tanks provide the flexibility needed for many Commercial applications. Installed individually, or in parallel manifold, these storage tanks can provide 80% draw capability without an appreciable temperature decrease in single temperature applications. Construction Features: • Long life tank design – proprietary steel formulation with two coats of high temperature porcelain enamel to maximize corrosion resistance resulting in a superior tank design. Two heavy duty magnesium anode rods are installed for longer tank life. • Space saving design – unlike other storage tanks, the ST80 and ST120 can pass through a 30" opening and the ST175 only requires a 33" opening – ideal for boiler room doors. • Efficient design – 2" of rigid polyurethane foam insulation provides superior insulating qualities resulting in reduced operating costs. Our patented process of injecting foam into the insulating cavity adds additional durability and toughness to the baked enamel steel outer jacket. • Tank openings – circulating line connections and hot outlet are 2" NPT on the ST80 and ST120 and 2-1/2" NPT on the ST175. Other openings are provided for relief valve and temperature control. ST175 equipped with a hand-hole cleanout. Certifications and Ratings: • Efficiency – these models meet or exceed thermal efficiency and standby loss requirements of current ASHRAE standards. (Part of the Federally mandated Energy Policy Act (EPact)). ASME Models Available • Optional construction – ASME construction is available on all storage tank models. Model numbers are ST80A, ST120A and ST175A • T&P valve – must be ordered separately based on water heater BTU input. Continued on reverse. Commercial Storage Tanks continued. DIMENSIONAL INFORMATION (All dimensions shown in English and Metric) WATER CONNECTIONS TOP FRONT OUTLET SIDE APPROXIMATE SHIPPING WEIGHT STD. ASME MODEL NUMBER UNITS A B C D ST80(A) inches 58-5/16 24-7/16 13-3/16 6-3/16 2 2 220 lbs. mm 1481 621 335 157 51 51 100 kgs. 118 kgs. ST120(A) inches 59-1/4 28-1/4 11-1/16 4-1/16 2 2 300 lbs. 340 lbs. mm 1505 718 281 103 51 51 136 kgs. 154 kgs. ST175(A) inches 67-1/4 32-1/4 12-9/16 5-9/16 2-1/2 2-1/2 600 lbs. 600 lbs. mm 1708 819 319 141 64 64 272 kgs. 272 kgs. 260 lbs. NOTE: 1" NPT drain opening on ST175(A). Handhole cleanout on ST175(A) only. 1" NPT RELIEF VALVE OPENING APPROXIMATE WIDTH REQUIRED FOR MANIFOLDED STORAGE TANKS (Shown in English and Metric) ST80(A) ST120(A) UNITS WITH FACTORY MANIFOLD KITS WITH FACTORY MANIFOLD KITS ST175(A) inches 54 58 66 mm 1372 1473 1676 inches 82 87 102 2083 2210 2591 MANIFOLD TYPE Duplex Triplex mm Quadruplex HOT OUTLET OPENING inches 108 116 137 mm 2743 2946 3480 HOT 3/4" NPT THERMOMETER OPENING B TANK INFORMATION (Shown in English and Metric) MODEL NUMBER TANK CAPACITY GALLONS LITERS MAXIMUM WORKING PRESSURE STD. ASME ST80(A) 80 303 150 PSI 125 PSI 1034 kPa 862 kPa ST120(A) 115 435 150 PSI 160 PSI 1034 kPa 1103 kPa ST175(A) 175 662 150 PSI 150 PSI 1034 kPa 1034 kPa 3/4" NPT AQUASTAT OPENING A OPENINGS FOR CIRCULATING LINES C D Recommended Specifications: Storage Tank(s) shall be model ________________, manufactured by RHEEM-RUUD. Storage Tank(s) shall have a storage capacity of ________ gallons. Tank(s) interior shall be double coated with a high temperature porcelain enamel and furnished with two magnesium anode rods rigidly supported. Tank(s) shall have a working pressure rating of _______ psi, and shall be completely assembled. Tank(s) shall be insulated with 2" of rigid polyurethane foam insulation. Storage Tank(s) shall be covered by a five year limited warranty against tank leaks. ADD FOR ASME CONSTRUCTION Storage Tank(s) shall be constructed in accordance with the requirements of the ASME Boiler Pressure Vessel Code, Section IV Part HLW. Limited Warranty This product features a five year limited warranty against tank leaks. Please refer to Commercial Warranty Information brochure for complete warranty information. C O M M E R C I A L W A T E R H E A T E R S In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com Rheem Canada Ltd./Ltée,128 Barton Street West, Hamilton, Ontario L8N 3P3 P R I N T E D I N U. S . A 01/07 WP F O R M N O. R R 1 0 2 C - 3 R e v. 9
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Keywords : Spec Sheet Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2007:01:08 14:40:43-06:00 Modify Date : 2007:01:08 14:40:55-06:00 Metadata Date : 2007:01:08 14:40:55-06:00 Creator Tool : PScript5.dll Version 5.2.2 Document ID : uuid:D88F3535589FDB11B4E9C838F05663F7 Instance ID : uuid:0f58e50f-0fad-48c8-bffa-c3c6e2ba73e1 Derived From Document Name : uuid:00e8cdb5-27ce-47cb-bc20-8951248b5d56 Derived From Document ID : uuid:fe6fb599-8e77-43e8-8a6f-e67db7e361ad Format : application/pdf Title : RR102C-3.pdf Description : Commercial Storage Tanks Subject : Spec Sheet Creator : myra.smith Page Count : 2 Author : myra.smithEXIF Metadata provided by EXIF.tools