Rheem Criterion Ii Installation Manual ManualsLib Makes It Easy To Find Manuals Online!
2014-12-11
: Rheem Rheem-Criterion-Ii-Installation-Manual-121105 rheem-criterion-ii-installation-manual-121105 rheem pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
FORM NO. G11-449 REV. 6 Supersedes Form No. G11-449 Rev. 5 GAS FURNACES ® CRITERION II 80.0-82.2% A.F.U.E.✝ DOWNFLOW GAS FURNACES The Rheem® Criterion® II line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by CSA. Features Patented heat exchanger, constructed of both stainless and aluminized steel for the maximum in corrosion resistance. ■ Low profile “34 inch” [864 mm] design is lighter and easier to handle, and leaves room for optional equipment. ■ Left or right side gas and electric inlet connections with quick, simple change. ■ Direct Spark ignition models and integrated board with humidifier and electronic air cleaner hookups. ■ Insulated blower compartment helps to reduce jacket loss and noise. ■ Pre-paint galvanized steel cabinet. ■ Molded permanent filter. ■ Grab-holes in doors to aid in easy door removal and replacement. A variety of cooling coils and plenums designed to use with Rheem Criterion II gas furnaces are available as optional accessories. ■ RGLH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kW] ENER ✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. UIDE Annual Fuel Utilization Efficiency - AFUE THIS MODEL 80.0% MID 78% 82% HIGH 88% 97% RHEEM CRITERION II 80% DOWNFLOW GAS FURNACE Molded Permanent Filter Integrated Furnace Control Heat Exchanger Draft Inducer Motor Direct Spark Ignitor with Remote Sense In-Shot Burners STANDARD EQUIPMENT Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multispeed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; on-board twinning; fused transformer (secondary), 3rd speed option for continuous fan; common heat/cool terminal. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. 2 Rheem Manufacturing Company All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition is 100% lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS MODEL NUMBERS RGLH- SERIES Input–BTU/Hr [kW] ➁ Heating Capacity BTU/Hr [kW] ➀ High Altitude Input [kW] High Altitude Output Capacity [kW] Heat Ext. Static Pressure [kPa] 05EAUER 05NAUER 50,000 [15] 41,000 [12] 45,000 [13] 07EAUER 07NAUER 75,000 [22] 60,000 [18] 67,500 [19.8] 07EAMGR 07NAMGR 75,000 [22] 60,500 [18] 67,500 [19.8] 10EAMER 10NAMER 100,000 [29.3] 80,000 [23] 90,000 [26.4] 10EBRJR 10NBRJR 100,000 [29.3] 81,000 [24] 90,000 [26.4] 12EARJR 12NARJR 125,000 [36.6] 99,000 [29] 112,500 [33] 15EARJR 15NARJR 150,000 [44] 120,000 [35] 135,000 [39.6] 36,500 [10.7] 53,500 [15.7] 54,000 [15.8] 72,000 [21.1] 72,500 [21.2] 89,000 [26.1] 107,500 [31.5] .10 [.025] .12 [.029] .12 [.029] .15 [.037] .20 [.05] .20 [.05] 11 x 6 [279 x 152] 11 x 6 [279 x 152] 11 x 7 [279 x 178] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 3/4-4-PSC 3/4-4-PSC 3/4-4-PSC [559] 9.5 MED-LOW MED-HIGH 2000 [944] .50 [.12] [559] 9.5 MED-LOW MED-HIGH 2000 [944] .50 [.12] [559] 9.5 MED-LOW MED-HIGH 2000 [944] .50 [.12] 40-70 [22.2-38.9] 40-70 [22.2-38.9] 50-80 [27.8-44.4] 190 [87.8] (2) 14 x 20 [356 x 508] 120 [54.4] 80% 180 [82.2] (2) 14 x 20 [356 x 508] 140 [63.5] 80% 190 [87.8] (2) 14 x 20 [356 x 508] 150 [68.0] 80% 74.7/74.7 75.2/75.3 76.0/75.9 Motor H.P. [W]–Speeds [W]– PSC Type Motor Full Load Amps Heating Speed Cooling Speed Cooling CFM @ .5" [kPa] E.S.P. (Nominal) [L/s] Rated E.S.P. (In. W.C.) [kPa] 1/2-4-PSC 1/2-4-PSC 3/4-4-PSC [373] 6.8 MED-LOW HIGH 1200 [566] .50 [.12] [373] 7.1 MED-HIGH HIGH 1200 [566] .50 [.12] [559] 9.5 MED-LOW MED-HIGH 1600 [755] .50 [.12] Temperature Rise Range °F [°C] 25-55 [13.9-30.6] 40-70 [22.2-38.9] 25-55 [13.9-30.6] Max. Outlet Air Temp. °F [°C] 155 [68.3] (1) 14 x 20 [356 x 508] 85 [38.6] 82.2% 165 [73.9] (2) 12 x 20 [305 x 508] 105 [47.6] 80.5% 155 [68.3] (2) 12 x 20 [305 x 508] 105 [47.6] 81.1% .15 [.037] 11 x 6 = 10*AU [279 x 152] 11 x 7 = 10*AM [279 x 178 1/2-4-PSC [373] 7.1 MED-HIGH HIGH 1200 [566] .50 [.12] 55-85 = 10*AU [30.6-47.2] 45-75 = 10*AM [25-41.7] 190 [87.8] (2) 12 x 20 [305 x 508] 115 [52.2] 80.2% 75.9/76.2 74.4/74.9 75.1/75.5 75.2/75.2 Blower (D x W) [mm] Standard Filter [mm] Approx. Shipping Weight (Lbs.) [kg] AFUE–Electric Ignition Models ➀ California Seasonal Efficiency– Electric Ignition Nox Models NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" N.P.T. ➀ In accordance with D.O.E. test procedures. ➁ See Conversion Kit Index Form No. 92-21519-52 for U.S. models and Form No. 92-21519-53 for Canadian models for high altitude derate. MODEL IDENTIFICATION—DOWNFLOW MODELS R G L H Rheem Gas Furnace Downflow Design Series [ — 07E A U E Heating Input Designation Variations A = Std. Cabinet B = Wide Cabinet Blower Designation U = 11 x 6 [279 x 152 mm] M = 11 x 7 [279 x 178 mm] R = 11 x 10 [279 x 254 mm] Heating & Cooling Designation S = 500-1200 CFM [236-566 L/s] E = 1100-1330 CFM [519-628 L/s] G = 1450-1750 CFM [684-826 L/s] J = 1800-2075 CFM [850-979 L/s] Electric Ignition NOx Model Input BTU/HR 05E 07E 10E 12E 15E 05N 07N 10N 12N 15N 50,000 [15 kW] 75,000 [22 kW] 100,000 [29 kW] 125,000 [37 kW] 150,000 [44 kW] R Fuel Type R = Natural Gas, U.S. and Canadian Standard Furnace ] Designates Metric Conversions Rheem Manufacturing Company 3 DOWNFLOW DIMENSIONS TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] REDUCED CLEARANCES (IN.) [mm] MODEL RGLHSERIES A B C D E 05 07 10 (A) 10 (B) 12 15 14 [356] 171/2 [445] 171/2 [445] 21 [533] 241/2 [622] 241/2 [622] 1227/32 [326] 1611/32 [415] 1611/32 [415] 1927/32 [504] 2311/32 [593] 2311/32 [593] 103/8 [264] 121/8 [308] 121/8 [308] 137/8 [352] 155/8 [397] 155/8 [397] ➀ ➀ 131/8 [333] 165/8 [422] 165/8 [422] 201/8 [511] 235/8 [600] 235/8 [600] ➀ ➀ ➀ ➀ LEFT SIDE 0 0 0 0 0 0 RIGHT SIDE 4➁ 3➁ 3➁ 0 0 0 BACK TOP FRONT VENT 0 0 0 0 0 0 1 [25] 1 [25] 1 [25] 1 [25] 1 [25] 1 [25] 3 [76] 3 [76] 3 [76] 3 [76] 3 [76] 3 [76] 6 [152] ➂ 6 [152] ➂ 6 [152] ➂ 6 [152] ➂ 6 [152] ➂ 6 [152] ➂ SHIP. WGTS. (LBS.) [kg] 85 [38.6] 105 [47.6] 115 [52.2] 120 [54.4] 140 [63.5] 150 [68] NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. ➁ May be 0" [0 mm] with type B vent. ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with ANSI Z21.47-1993 • CAN/CGA-2.3-M93 venting table guidelines, and in accordance with local codes. 4 Rheem Manufacturing Company [ ] Designates Metric Conversions BLOWER PERFORMANCE DATA—DOWNFLOW MODELS MODEL NUMBER RGLHSERIES BLOWER SIZE [mm] MOTOR H.P. [W] 05MAUER 05EAUE 05NAUER 11 x 6 [279 x 152] 1/2 [373] 07MAUER 07EAUE 07EAUER 11 x 6 [279 x 152] 1/2 [373] 07MAMGR 07EAMG 07NAMGR 11 x 7 [279 x 178] 3/4 [559] * 11 x 7 [279 x 178] * 1/2 [373] 10EBRJR 10NBRJR 11 x 10 [279 x 254] 3/4 [559] 12EARJR 12NARJR 11 x 10 [279 x 254] 3/4 [559] 15MARJR 15EARJR 15NARJR 11 x 10 [279 x 254] 3/4 [559] * 10EAME* 10NAMER BLOWER SPEED CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN .1 [.02] .2 [.05] .3 [.07] .4 [.10] .5 [.12] .6 [.15] .7 [.17] LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH 735 [347] 1025 [484] 1185 [559] 1345 [635] 835 [394] 990 [467] 1140 [538] 1300 [614] 1210 [571] 1580 [746] 1915 [904] —0000 715 1015 1165 1330 820 975 1125 1290 1205 1560 1880 2050 [337] [479] [550] [628] [387] [460] [531] [609] [569] [736] [887] [967] 690 995 1150 1310 800 955 1105 1265 1195 1550 1825 1995 [326] [470] [543] [618] [378] [451] [522] [597] [564] [732] [861] [942] 660 975 1130 1295 775 935 1080 1245 1180 1530 1790 1940 [311] [460] [533] [611] [366] [441] [510] [588] [557] [722] [845] [916] 635 955 1100 1265 750 905 1050 1215 1165 1495 1740 1885 [300] [451] [519] [597] [354] [427] [496] [573] [550] [706] [821] [890] 605 930 1075 1235 720 875 1020 1180 1155 1465 1675 1835 [286] [439] [507] [583] [340] [413] [481] [557] [545] [691] [791] [866] 575 [271] 905 [427] 1040 [491] 1205 [569] 685 [323] 835 [394] 980 [463] 1140 [538] 1130 [533] 1430 [675] 1600 [755] 1770 [835] LOW MED-LO MED-HI HIGH 935 [441]* 1070 [505] 1240 [585] 1420 [670] 910 1055 1210 1395 [429]* [498] [571] [658] 885 1040 1190 1370 [418]* [491] [562] [647] 855 1010 1165 1340 [404]* [477] [550] [632] 825 980 1135 1305 [389]* [463] [536] [616] 785 945 1095 1265 [370]* [446] [517] [597] 760 [359]* 905 [427] 1055 [498] 1220 [576] LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH 1330 [628] 1690 [798] —0000 —0000 1330 [628] —0000 —0000 —0000 1300 [614] 1675 [791] 2105 [993] —0000 1295 [611] 1670 [788] 2085 [984] 2410 [1137] 1295 [611] 1690 [798] 2090 [986] 2395 [1130] 1280 [604] 1650 [779] 2075 [979] 2340 [1104] 1285 [606] 1655 [781] 2055 [970] 2355 [1111] 1280 [604] 1660 [783] 2035 [960] 2335 [1102] 1230 [580] 1620 [765] 2035 [960] 2290 [1081] 1245 [588] 1615 [762] 2005 [946] 2305 [1088] 1240 [585] 1635 [772] 1985 [937] 2260 [1067] 1205 [569] 1570 [741] 1990 [939] 2215 [1045] 1225 [578] 1585 [748] 1970 [930] 2240 [1057] 1215 [573] 1580 [746] 1930 [911] 2185 [1031] 1170 [552] 1545 [729] 1955 [923] 2145 [1012] 1205 [569] 1565 [739] 1945 [918] 2165 [1022] 1210 [571] 1535 [724] 1850 [873] 2080 [982] 1115 [526] 1485 [701] 1900 [897] 2080 [982] 1160 [547] 1525 [720] 1880 [887] 2100 [991] 1175 [555] 1480 [698] 1785 [842] 1965 [927] 1030 [486] 1425 [673] 1815 [857] 1995 [942] NOTES: *Not to be used as a heating speed. Data compiled with factory filters installed. [ ] Designates Metric Conversions Rheem Manufacturing Company 5 ACCESSORIES—DOWNFLOW DOWNFLOW WARNING: Unit design is certified for installation on non-combustible floor. A special factory supplied combustible floor sub-base is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage and personal injury. COMBUSTIBLE FLOOR BASE DIMENSIONS COMBUSTIBLE FLOOR BASE RXGC-B14 RXGC-B17 RXGC-B21 RXGC-B24 USE WITH FURNACE SIZES RGLH-05 RGLH-07, RGLH-10(-)A RGLH-10(-)B RGLH-12, RGLH-15 A IN. [mm] 141/2 [368] 18 [457] 211/2 [546] 25 [635] B IN. [mm] 131/4 [337] 163/4 [425] 201/4 [514] 233/4 [603] C IN. [mm] 111/4 [286] 143/4 [451] 181/4 [464] 213/4 [552] PLENUM DATA—“A” COILS Plenum adapters are required in some instances for use on downflow applications when plenum and furnace size do not match. FURNACE WIDTH IN. [mm] 14 [356] 14 [356] 171/2 [445] 171/2 [445] 171/2 [445] 171/2 [445] 21 [533] 21 [533] 241/2 [622] 241/2 [622] PLENUM WIDTH IN. [mm] 161/4 [413] 201/4 [514] 161/4 [413] 201/4 [514] 215/8 [549] 251/4 [641] 221/4 [565] 251/4 [641] 251/4 [641] 215/8 [549] PLENUM ADAPTER DOWNFLOW COIL PLENUM RXAA-C178 RXAA-C179 RXAA-C186 RXAA-C180 RXAA-C189 RXAA-C181 RXAA-C182 RXAA-C183 RXAA-C184 RXAA-C190 RXAL-B16BU RXAL-B20BU RXAL-B16BU RXAL-B20BU RXAL-B21BU RXAL-B25BU RXAL-B22BU RXAL-B25BU RXAL-B25BU RXAL-B21BU NOTE: See Form Number C11-206 for MultiFlex coil data. RXPF-F01 and F02 FOSSIL FUEL KITS—are for use with Rheem Heat Pumps and Criterion II warm air furnaces. The RXPF-F02 meets TVA requirements. RXGF-CC* FILTER RACK—Downflow top return mount. NOTE: Filter racks are shipped without filters. *Filters available through PROSTOCK ™. OPTION CODE FOR HIGH ALTITUDE: US-277 Canada-298 (Kit packaged with furnace. Requires field installation.) GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. 6 Rheem Manufacturing Company Gas Heat Exchanger Limited Warranty .......Twenty (20) Years *Any Other Part..............................................One (5) Years *This five year limited warranty is applicable only to single-phase products installed in residential applications on or after January 1, 2001. NOTES Rheem Manufacturing Company 7 Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 11-01 DC FORM NO. G11-449 REV. 6 Supersedes Form No. G11-449 Rev. 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Create Date : 2013:09:25 22:02:24Z Keywords : manuals, instruction manuals, user manuals, service manuals, user guides, pdf manuals, owners manuals, installation guides Modify Date : 2014:12:07 11:48:14+08:00 Subject : Search through 700.000 manuals online & and download pdf manuals. Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Description : Search through 700.000 manuals online & and download pdf manuals. Title : ManualsLib - Makes it easy to find manuals online! Creator Tool : pdftk 1.44 - www.pdftk.com Metadata Date : 2014:12:07 11:48:14+08:00 Producer : itext-paulo-155 (itextpdf.sf.net-lowagie.com) Document ID : uuid:acae5d88-2ac0-a640-9731-b9b503fed516 Instance ID : uuid:ce9e3d60-1a28-5f4c-85d7-68f18bcc0ec8 Page Count : 8EXIF Metadata provided by EXIF.tools