Rheem Prestige Series Up To 80 Afue Variable Speed Downflow Submittal Sheet

2015-04-02

: Rheem Rheem-Prestige-Series-Up-To-80-Afue-Variable-Speed-Downflow-Submittal-Sheet-683741 rheem-prestige-series-up-to-80-afue-variable-speed-downflow-submittal-sheet-683741 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 3

SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
FORM NO. X33-1445
Supersedes Form No. X33-1285 Rev. 2
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ........ _______ MBH [kW]
TOTAL CAPACITY OUTPUT*...... _______ MBH [kW]
DESIGN TEMP. RISE ................ _______ °F [°C] DB
AFUE .................................................. _______ %
CALIFORNIA SEASONAL
EFFICIENCY .................................... _______ %
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY .................. _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................ _______ IWG
BLOWER SPEED.............................. _______ RPM
POWER OUTPUT REQUIREMENT .... _______ BHP
MOTOR RATING .......................... _______ HP [W]
POWER INPUT REQUIREMENT .......... _______ kW
ELECTRICAL DATA
POWER SUPPLY ................................ _______ Hz
TOTAL UNIT AMPACITY.................. _______ AMPS
MINIMUM WIRE SIZE ...................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............ _______ AMPS
FEATURES FOR R802V DOWNFLOW
80% residential Gas Furnace CSA certified
Two stages of operation to save energy and maintain optimal
comfort level.
Variable speed blower motor technology provides ultimate
humidity control, quieter sound levels, and year round energy
savings
EcoNet enabled HVAC product
PlusOneDiagnostics — 7 Segment LED all units
PlusOneIgnition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion
resistance and thermal fatigue reliability.
Low profile 34" cabinet ideal for space constrained
installations
Integrated Control board features dip switches for easy
system set up
Insulated blower compartment
QR code for quick access to product information from your
smart phone or tablet
Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.
FIELD INSTALLED ACCESSORIES
Filter Rack RXGF-CC ................................................................
Combustible Floor Base RXGC-B17 ........................................
Combustible Floor Base RXGC-B21 ........................................
Combustible Floor Base RXGC-B24 ........................................
EcoNet Control RETST600SYS ................................................
DOWNFLOW GAS FURNACE
R802V Series
80% A.F.U.E.
Input Rates 75 to 125 kBTU [22 to 37 kW]
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices. Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 11-14 QG FORM NO. X33-1445
Supersedes Form No. X33-1209
Downflow Dimensions
Dimensions and Clearance to Combustible Material (inches) [mm]
MODEL
R802V-
SERIES
A B C D E
REDUCED CLEARANCES (IN.) [mm]
075317 171/2[445] 1611/32 [415] 121/8[308] 165/8[422] 03 0 1 [25] 3 [76] 6 [152]
LEFT
SIDE
RIGHT
SIDE BACK TOP FRONT VENT SHIP. WGTS.
(LBS.) [kg]
100 211/2[533] 1927/32 [504] 137/8[352] 201/8[511] 0 0 0 1 [25] 3 [76] 6 [152] 120 [54.4]
110 [49.9]
075421 211/2[533] 1927/32 [504] 137/8[352] 201/8[511] 0 0 0 1 [25] 3 [76] 6 [152] 115 [52.2]
125 241/2[622] 2311/32 [593] 155/8[397] 235/8[600] 0 0 0 1 [25] 3 [76] 6 [152] 140 [63.5]
NOTES:May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.
May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with
local codes.
[ ] Designates Metric Conversions

Navigation menu