Rheem Professional Classic Plus Series Heavy Duty Specification Sheet

2015-04-02

: Rheem Rheem-Professional-Classic-Plus-Series-Heavy-Duty-Specification-Sheet-683448 rheem-professional-classic-plus-series-heavy-duty-specification-sheet-683448 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadRheem Rheem-Professional-Classic-Plus-Series-Heavy-Duty-Specification-Sheet-  Rheem-professional-classic-plus-series-heavy-duty-specification-sheet
Open PDF In BrowserView PDF
Residential Gas
INTEGRATED
H O M E C O M F O RT Classic Plus
Professional
Water
Heavy Duty Water Heaters

Professional Classic Plus™ Heavy Duty
gas water heaters exceed ANSI standards
for flammable vapor ignition resistance
Efficiency

Easy to Light

• .49 - .58 EF

• Piezo Ignitor - no matches required

Performance

Low Emissions

• FHR: Up to 135 gallons for natural
gas, up to 125 gallons for LP gas

• Eco-friendly burner, low NOx design

• Recovery: Up to 75.8 gallons for
­natural gas, up to 65.7 gallons for LP
gas at a 90 degree rise

Guardian System & Sensor
™

• Exclusive air/fuel shut-off device
• Maintenance free – no filter to clean
• Disables the heater in the presence of
flammable vapor accumulation

Combustion Shut-off System

Flame Arrestor Plate

• Meets 40 ng/J NOx r­equirements

Longer Life
• Rheem exclusive R-Tech (resistored)
anode rod provides long-lasting tank
protection

High Altitude Compliant
• All models are certified for a
­ pplications
up to 7,700 feet above sea level
• Some models are c
­ ertified up to
10,200 feet above sea level (check
factory for listings)

2

ProClub
Points

Plus…
• Enhanced-flow brass drain valve
• Temperature and pressure relief valve
included

Maintenance Free

Self-Cleaning
• 48, 60 & 63 gallon models only
• EverKleen™ patented system fights
sediment build-up

• Low lead compliant
• Side water connections for space
heating applications for 48, 63, 75
and 98-gallon models
• Standard replacement parts

Warranty
• 8-Year limited tank and parts warranty*
• With ProtectionPlus™ the 8-year limited
tank warranty becomes 12-year

Professional Classic Plus
Heavy Duty
48, 60, 63, 75 and
98-Gallon Capacities
Up to 75,100 Btu/h
Natural and LP Gas

*See Residential Warranty Certificate for ­
complete information

• Reduces fuel costs
• Fights sediment build-up

Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.

myrheem.com/proclub

See dimensions chart on back.

IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT
PRINTED IN U.S.A. 09/13 WP FORM NO. PRO+G RHHD

Residential Gas
INTEGRATED
H O M E C O M F O RT Classic Plus
Professional
Water
Heavy Duty Water Heaters

Professional Classic Plus™ Heavy Duty Specifications
	

	
	
	
	
	

DESCRIPTION	

FEATURES	

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)	

ENERGY INFO.

T									
HT. TO		
WATER	
HT. TO	
WATER				
GAS INPUT IN	
RECOVERY IN	
FIRST HOUR
ENERGY
Y
		
	 HT. TO	TANK		
GAS 	
VENT	
CONN.	 SIDE T&P	 CONN.	
SHIP.	
THOUS. BTU/H	
G.P.H. 90° RISE	
DEL. G.P.H.
FACTOR
P	 GAL.	MODEL	
	 VENT	 HT.	 DIAM.	CONN.	 SIZE	 CNTR.	 VALVE	 size	WT.	
E	 CAP.	NUMBER	NAT.	
LP	NAT.	
LP	NAT.	
LP	
A	
B	
C	
D	
E	
F	
G	
H	
(LBS)	NAT.	
LP

	Tall	 48	 PRO+G48-65N RH58	

65		

	Tall	 48	 PRO+G48-48P RH58		
	
Tall	
60	
PRO+G60-50N RH56	

65.7		

48		

98		

48.5		

62-1/2	58-1/2	21-3/4	

14	

4	

11	

51-3/4	

3/4	

180	

88	 62-1/2	58-1/2	21-3/4	

14	

4	

11	

51-3/4	

3/4	

180		

0.58
0.58

50		 50.5		 107		 62	58	23	13-1/4	4	 8	48-1/2	3/4	 180	 0.56

	
Tall	
60	
PRO+G60-45P RH56		 45		 45.5		107	62	58	23	13-1/4	4	 8	48-1/2	3/4	 180		
	
Tall	63	
PRO+G63-65N RH55	

65		

	
Tall	63	
PRO+G63-50P RH55		
	 Tall	

75	 PRO+G75-75N RH	

	 Tall	

75	 PRO+G75-65P RH53		

	
Tall	98	
PRO+G98-75N RH49	

	

50		

75.1		

141		

65.7		

75.8		

65		

115		

65	61-1/4	23	

50.5		 110	 65	61-1/4	23	

75.8		

65		

75		

	
Tall	98	
PRO+G98-65P RH49		

65.7		

109	

14	
14	

4	

11	 54-3/4	 3/4	

225	

0.56

0.55

4	

11	 54-3/4	 3/4	

225		

64	

60	

26-1/4	

14-3/4	

4	

11	

53-1/4	

1	

320	

64	

60	

26-1/4	

14-3/4	

4	

11	

53-1/4	

1	

320		

0.55
0.53

135		 67-3/4	64	27-1/4	14-3/8	 4	

11	 57-3/16	 1	

350	

0.49

65.7		 125	67-3/4	64	27-1/4	14-3/8	 4	

11	 57-3/16	 1	

350		

0.49

Energy Factor based on D.O.E. (Department of Energy) test ­procedures.

FLUE

ANODE ROD

H

H

HOT
WATER
CONNECTION

COLD
WATER
CONNECTION

F
E
3/4" N.P.T.
RELIEF
VALVE
OPENING

C
A B

G
1/2"

SIDE TAPS
(48, 63, 75
& 98 GAL.
MODELS
ONLY)

D

SIDE TAPS ON
48, 63, 75 & 98 GAL. MODELS ONLY

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 • www.rheem.com
IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT
PRINTED IN U.S.A. 09/13 WP FORM NO. PRO+G RHHD



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2013:09:18 16:28:55-04:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2013:09:23 14:30:36-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Metadata Date                   : 2013:09:23 14:30:36-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:d5f3f4e3-df71-f141-b368-de3bd97c23e0
Original Document ID            : xmp.did:0A80117407206811B34BA559CEB6FCA7
Document ID                     : xmp.id:398A1225E32068118083897ABF10DEB7
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:388A1225E32068118083897ABF10DEB7
Derived From Document ID        : xmp.did:3000BFC0AF21681195FE8AD729C011B2
Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2013:09:18 16:28:55-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu