Rheem Professional Classic Plus Series Induced Specification Sheet

2015-04-02

: Rheem Rheem-Professional-Classic-Plus-Series-Induced--Specification-Sheet-683433 rheem-professional-classic-plus-series-induced--specification-sheet-683433 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadRheem Rheem-Professional-Classic-Plus-Series-Induced--Specification-Sheet-  Rheem-professional-classic-plus-series-induced--specification-sheet
Open PDF In BrowserView PDF
Residential Gas
INTEGRATED
HO M E C O M F O RT Classic Plus
Professional
Water
Induced Draft Water Heater

Professional Classic Plus™ Induced Draft is a
compact, energy saving 29-gallon gas water heater
that outperforms standard 50-gallon models
Efficiency

Guardian System™ & Sensor

• .70 EF

• Exclusive air/fuel shut-off device for
­double protection

• Energy Star® rated
• Well insulated for reduced stand-by
heat loss

Performance

• Maintenance free – no filter to clean
• Protective control system that
disables the heater in the presence of
flammable vapor accumulation

• 29-Gallon capacity with 90-gallon
FHR performance
• Recovery rate of 61 GPH at 90
degree rise, exceeds standard
50-gallon by up to 49%

Combustion Shut-off System

Flame Arrestor Plate

Compact Size
• Small foot print, 17-3/4 inch ­
diameter
•F
 ast one-man installation, compact
and light weight

Self-Diagnostic System
• Integrated self-diagnostic
system control for easy
installation and service

Low Emissions
• Eco-friendly burner, low NOx design
• Meets 40 ng/J NOx requirements

Maintenance Free

Longer Life
• Rheem exclusive R-Tech (resistored)
anode rod provides long-lasting tank
protection

High Altitude Compliant
• Certified for applications up to 7,700
feet above sea level

Plus…

Technology

• Dual certified for both potable water
and space heating

• 110 VAC draft inducer (includes
8-foot cord with 3-prong plug)

• Enhanced-flow brass drain valve

• Standard atmospheric Category I,
double-wall, B-vent, 3" or 4"
(4" adaptor included)
What is a Fan Assisted Draft Inducer?
Standard gas water heaters produce
­extremely hot air during combustion, which
moves the combustion gases quickly up
the chimney. The Professional Classic Plus
Induced Draft is much more efficient (i.e. it
puts more heat in the water and less heat up
the chimney).
A proprietary baffle and flue design r­etains
the heat longer, therefore a device is needed
to propel the air and gases upward.
Fan assisted draft inducer creates the proper
draft to expel the combustion gases.

• Temperature and pressure relief valve
included
• Low lead compliant
• EverKleen™ patented system fights
sediment build-up

Professional Classic Plus
Induced Draft
29-Gallon Capacity
60,000 Btu/h
Natural Gas

• Standard replacement parts

Warranty
• 8-Year limited tank and parts
­warranty*

LEED Point = 1

• With ProtectionPlus™ the 8-year limited
tank warranty becomes 10-year
ProtectionPlus – order part number
SP20081 (6 pack only)
*See Residential Warranty Certificate for ­
complete information

See dimensions chart on back.

IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT
PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHIDCAN

Residential Gas
INTEGRATED
HO M E C O M F O RT Classic Plus
Professional
Water
Induced Draft Water Heater

Rheem Professional Classic Plus Induced Draft Specifications
		

DESCRIPTION	

FEATURES	

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)	

										
				
GAS INPUT IN	
RECOVERY IN	 FIRST HOUR	
HT. TO	
TANK		
	 GAL.	 MODEL	
THOUS. BTU/H	
G.P.H. 90° RISE	
DEL. G.P.H.	
VENT	
HT.	
DIAM.	
	 CAP.	 NUMBER	
NAT.	
NAT.	
NAT.
	
A	
B	
C	
	

29	

PRO+G29T-60N CN70 ID	

60	

61	

90	

65-1/2	

58-1/4	

HT. TO		
GAS	
VENT 	
CONN.	
SIZE	
D	
E	

17-3/4	

14	

3 or 4	

WATER	
CONN.	
CNTR.	
F	

8	

ENERGY INFO.

HT. TO				
SIDE	
WATER	
SHIP.	
ENERGY	
T&P	
CONN.	
WT.	
FACTOR	
G	
H	
(LBS)	
NAT.	

51-9/16	

3/4	

136	

AVG. ANN.
OPERATING
COST
NAT.

0.70	

$261

NOTE: No propane available for this unit.

Performance
First Hour Rating

Recovery

92

PRO+G29T-60N CN70 ID

60
50

86

40

Gallons

88

Conventional
50-Gal. Gas

84
82

PRO+G29T-60N CN70 ID

F
E

Conventional
50-Gal. Gas

10

29 Gal.

0

50 Gal.

29 Gal.

A B
1/2"

Energy Efficiency

G

D

0.80

PRO+G29T-60N CN70 ID
Conventional
50-Gal. Gas

0.60

C

50 Gal.

Efficiency

0.70

COLD
WATER
CONNECTION

3/4" N.P.T.
RELIEF
VALVE
OPENING

30
20

80
78

H

HOT
WATER
CONNECTION

70

Energy Factor (EF)

Gallons

90

ANODE ROD

H

Therm-X-Guard thermal
expansion tank recommended. ­
See spec sheet 105-29
for correct sizing.

0.50
0.40
0.30
0.20
0.10

29 Gal.

50 Gal.

PRO+G29T-60N
CN70 ID

Energy Factor based on FTC Energy Guide labels.

50 Gal.

Footprint Comparison
Narrow 17-3/4 inch diameter fits
in a smaller space than standard
40 or 50-gallon models.

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.com
IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT

2
PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHIDCAN



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2014:01:14 14:53:27-05:00
Metadata Date                   : 2014:01:14 14:53:30-05:00
Modify Date                     : 2014:01:14 14:53:30-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:926df895-0283-3f4a-9d9b-aa9b885b11f7
Original Document ID            : xmp.did:0A80117407206811B34BA559CEB6FCA7
Document ID                     : xmp.id:F228E065FA2068118F62B1DC45D75973
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:F128E065FA2068118F62B1DC45D75973
Derived From Document ID        : xmp.did:C995E03064356811822AAFC53C065F3E
Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2014:01:14 14:53:27-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu