Residential Gas INTEGRATED HO M E C O M F O RT Classic Plus Professional Water Induced Draft Water Heater Professional Classic Plus™ Induced Draft is a compact, energy saving 29-gallon gas water heater that outperforms standard 50-gallon models Efficiency Guardian System™ & Sensor • .70 EF • Exclusive air/fuel shut-off device for double protection • Energy Star® rated • Well insulated for reduced stand-by heat loss Performance • Maintenance free – no filter to clean • Protective control system that disables the heater in the presence of flammable vapor accumulation • 29-Gallon capacity with 90-gallon FHR performance • Recovery rate of 61 GPH at 90 degree rise, exceeds standard 50-gallon by up to 49% Combustion Shut-off System Flame Arrestor Plate Compact Size • Small foot print, 17-3/4 inch diameter •F ast one-man installation, compact and light weight Self-Diagnostic System • Integrated self-diagnostic system control for easy installation and service Low Emissions • Eco-friendly burner, low NOx design • Meets 40 ng/J NOx requirements Maintenance Free Longer Life • Rheem exclusive R-Tech (resistored) anode rod provides long-lasting tank protection High Altitude Compliant • Certified for applications up to 7,700 feet above sea level Plus… Technology • Dual certified for both potable water and space heating • 110 VAC draft inducer (includes 8-foot cord with 3-prong plug) • Enhanced-flow brass drain valve • Standard atmospheric Category I, double-wall, B-vent, 3" or 4" (4" adaptor included) What is a Fan Assisted Draft Inducer? Standard gas water heaters produce extremely hot air during combustion, which moves the combustion gases quickly up the chimney. The Professional Classic Plus Induced Draft is much more efficient (i.e. it puts more heat in the water and less heat up the chimney). A proprietary baffle and flue design retains the heat longer, therefore a device is needed to propel the air and gases upward. Fan assisted draft inducer creates the proper draft to expel the combustion gases. • Temperature and pressure relief valve included • Low lead compliant • EverKleen™ patented system fights sediment build-up Professional Classic Plus Induced Draft 29-Gallon Capacity 60,000 Btu/h Natural Gas • Standard replacement parts Warranty • 8-Year limited tank and parts warranty* LEED Point = 1 • With ProtectionPlus™ the 8-year limited tank warranty becomes 10-year ProtectionPlus – order part number SP20081 (6 pack only) *See Residential Warranty Certificate for complete information See dimensions chart on back. IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHIDCAN Residential Gas INTEGRATED HO M E C O M F O RT Classic Plus Professional Water Induced Draft Water Heater Rheem Professional Classic Plus Induced Draft Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK GAL. MODEL THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CAP. NUMBER NAT. NAT. NAT. A B C 29 PRO+G29T-60N CN70 ID 60 61 90 65-1/2 58-1/4 HT. TO GAS VENT CONN. SIZE D E 17-3/4 14 3 or 4 WATER CONN. CNTR. F 8 ENERGY INFO. HT. TO SIDE WATER SHIP. ENERGY T&P CONN. WT. FACTOR G H (LBS) NAT. 51-9/16 3/4 136 AVG. ANN. OPERATING COST NAT. 0.70 $261 NOTE: No propane available for this unit. Performance First Hour Rating Recovery 92 PRO+G29T-60N CN70 ID 60 50 86 40 Gallons 88 Conventional 50-Gal. Gas 84 82 PRO+G29T-60N CN70 ID F E Conventional 50-Gal. Gas 10 29 Gal. 0 50 Gal. 29 Gal. A B 1/2" Energy Efficiency G D 0.80 PRO+G29T-60N CN70 ID Conventional 50-Gal. Gas 0.60 C 50 Gal. Efficiency 0.70 COLD WATER CONNECTION 3/4" N.P.T. RELIEF VALVE OPENING 30 20 80 78 H HOT WATER CONNECTION 70 Energy Factor (EF) Gallons 90 ANODE ROD H Therm-X-Guard thermal expansion tank recommended. See spec sheet 105-29 for correct sizing. 0.50 0.40 0.30 0.20 0.10 29 Gal. 50 Gal. PRO+G29T-60N CN70 ID Energy Factor based on FTC Energy Guide labels. 50 Gal. Footprint Comparison Narrow 17-3/4 inch diameter fits in a smaller space than standard 40 or 50-gallon models. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • www.rheem.com IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT 2 PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHIDCAN
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2014:01:14 14:53:27-05:00 Metadata Date : 2014:01:14 14:53:30-05:00 Modify Date : 2014:01:14 14:53:30-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:926df895-0283-3f4a-9d9b-aa9b885b11f7 Original Document ID : xmp.did:0A80117407206811B34BA559CEB6FCA7 Document ID : xmp.id:F228E065FA2068118F62B1DC45D75973 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:F128E065FA2068118F62B1DC45D75973 Derived From Document ID : xmp.did:C995E03064356811822AAFC53C065F3E Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:01:14 14:53:27-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools