Residential Gas
INTEGRATED
HOME COMFORT Classic Direct Vent
Professional
Water
Water Heaters for Manufactured Housing

Professional Classic™ Direct Vent gas water heaters
from Rheem are certified for Manufactured
Housing (HUD) and modular construction
Efficiency

Roof Jacks

• .58 - .61 EF

Performance
• FHR: 67-gallons for 50-gallon model,
60 gallons for 40-gallon model and 51
gallons for 30-gallon model
• Recovery rate is 32.3 gallons at a
90 degree rise for 50-gallon model,
30.3 gallons for 30 and 40-gallon
models

Flexibility
• Field convertible controls for natural
gas or LP operation included
• No external door is required
• Provides maximum design freedom
since it can be placed anywhere within
the home
• Hot water outlet located at top
• Cold water inlet at side for fast,
economical hook-up

12" Non-Adjustable & Air Inlet 	
15-32" Adjustable & Air Inlet	
30-60" Adjustable & Air Inlet	
48-95" Adjustable & Air Inlet	

AP12032E
AP12032B
AP12032C
AP12032D

Air Inlets
6" Non-Adjustable	
11-22" Adustable	

AP12019B
AP12017B

Extension Pipe Kit
Roof Jack Extension Pipe Kit	

AP12021

 oof jack and air inlet must be ordered separately
R
with 30, 40 and 50-gallon direct vent models and
must be in accordance with instructions furnished
with the heater. No other roof jack or air inlet
assemblies are approved for installation with this
heater. Clamps and secure strapping are packed
in water heater carton.

Longer Life
• Rheem exclusive R-Tech (resistored)
anode rod provides long-lasting tank
protection

Plus…

Adjustable Roof
Jack Vent

• Piezo ignition – easy light pilot

Design allows ­adjustment
to roof pitches of up to

• Factory installed temperature and
pressure relief valve – side location

5/12". Four roof
jacks ­available to
­accommodate roof
­thickness of 12" up to 95".

Direct Combustion
Air Inlet
Air is drawn directly into
­combustion chamber
through air inlet fixed
to base; 1/2" screen for
rodent p
­ rotection.

• Enhanced flow brass drain valve

• Low lead compliant
• EverKleen™ patented system fights
sediment build-up

Warranty
• 6-Year limited tank and parts
­warranty*
*See Residential Warranty Certificate for ­
complete information

Professional Classic
Direct Vent for
­Manufactured Housing

30, 40 and 50-Gallon Capacities
Up to 32,000 Btu/h
Natural and LP Gas

Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and
all state energy efficiency performance criteria.

See dimensions chart on back.

IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT
PRINTED IN U.S.A. 09/13 WP FORM NO. PROG RHMHDV

Residential Gas
INTEGRATED
HOME COMFORT Classic Direct Vent
Professional
Water
Water Heaters for Manufactured Housing

Professional Classic™ Direct Vent for Manufactured Housing Specifications
		

DESCRIPTION	

FEATURES	

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)	

	 T									
	 Y
		
GAS INPUT IN	
RECOVERY IN	 FIRST HOUR	
HT. TO	
TANK		
	 P	 GAL.	 MODEL	
THOUS. BTU/H	 G.P.H. 90° RISE	 DEL. G.P.H.	
VENT	
HT.	
DIAM.	
	 E	 CAP.	NUMBER	
NAT./LP	
NAT./LP	
NAT./LP	
A	
B	
C	

	 Tall	

30	 PROG30-30N RH61 MH DV	

30	

30.3	

51	

57	

	 Tall	

40	 PROG40-30N RH59 MH DV	

30	

30.3	

60	

57-1/2	

	 Tall	

50	 PROG50-32N RH58 MH DV	

32	

32.3	

67	

57	

57	

HT. TO		
GAS	
VENT	
CONN.	
SIZE	
D	
E	

ENERGY INFO.

ROOF 	
HT. TO	
WATER		
JACK	
SIDE T&P	 CONN.	 SHIP.	
VENT SIZE	
VALVE	
size	WT.	
F	
G	
H	
(LBS)	

	
ENERGY
FACTOR
NAT./LP

17-3/4	 14-1/2	

3	

5	

51-1/2	

20	

110	

0.61

57-1/2	 19-3/4	 14-1/2	

3	

5	

51-1/2	

20	

125	

0.59

3	

5	

51-1/2	

20	

150	

0.58

57	

21-3/4	 14-1/2	

Energy Factor based on D.O.E. (Department of Energy) test p
­ rocedures.

ADJUSTS TO PITCHES
OF UP TO 5/12"

F
24" MIN.

A
B

E

0" MIN.
WALL
CLEARANCE

C

RELIEF
VALVE
COLD
WATER
CONN.

G

1/2"

2"

D

H

WATER CONNECTIONS
ALL 3/4" N.P.T.

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 • www.rheem.com
IINNTTEEGGRAT
ED
MO
FO
RAT
E DH OHM
OEMCEOC
MRT
F O RT

2
PRINTED IN U.S.A. 09/13 WP FORM NO. PROG RHMHDV



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2013:09:18 16:16:09-04:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2013:09:23 14:25:30-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Metadata Date                   : 2013:09:23 14:25:30-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:88d77ed8-fd02-6f4b-9c3e-d6b69d8d3216
Original Document ID            : xmp.did:0A80117407206811B34BA559CEB6FCA7
Document ID                     : xmp.id:62700D5CE12068118083897ABF10DEB7
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:61700D5CE12068118083897ABF10DEB7
Derived From Document ID        : xmp.did:D750EA49AA216811923FE75EA4967D1F
Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2013:09:18 16:16:09-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu