Rheem Professional Classic Series Power Vent Specification Sheet

2015-04-02

: Rheem Rheem-Professional-Classic-Series-Power-Vent-Specification-Sheet-683475 rheem-professional-classic-series-power-vent-specification-sheet-683475 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

PRINTED IN U.S.A. 03/15 WP FORM NO. PROG RHPV Rev. 1
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
Professional
Classic
Power Vent gas water heaters
offer up to 100 foot vent runs, energy efficiency
and the Guardian System
Professional
Classic
Power Vent
40 and 50-Gallon Capacities
Up to 42,000 Btu/h
Natural and LP Gas
Efficiency

® rated
Performance





Self-Diagnostic System



Low Emissions

Features



connection

Guardian System & Sensor





Flexible Venting Options




Longer Life


High Altitude Compliant




Plus…


included






Warranty



With ProtectionPlus









Maintenance Free
Flame Arrestor PlateCombustion Shut-off System
LEED Point = 1
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional
Classic
Power Vent Water Heaters
See specifications chart on back.
PRINTED IN U.S.A. 03/15 WP FORM NO. PROG RHPV Rev. 1
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating 101 Bell Road
Montgomery, Alabama 36117-4305 www.rheem.com
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional
Classic
Power Vent Water Heaters
Professional
Classic
Power Vent Specifications
Energy Factor based on D.O.E. (Department of Energy) test procedures.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO HT. TO WATER HT. TO WATER
Y GAS INPUT IN RECOVERY IN FIRST HOUR TOP OF TANK GAS CONN. SIDE T&P CONN. SHIP. ENERGY
P GAL. MODEL THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. ASSEMBLY HT. DIAM. CONN. CNTR. VALVE SIzE WT. FACTOR
E CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G (LBS) NAT. LP
Tall 40 PROG40-40N RH67 PV 40 40.4 68 67-3/8 59 19-3/4 14 8 53-1/2 3/4 140 0.67
Tall 40 PROG40-36P RH67 PV 36 36.4 68 67-3/8 59 19-3/4 14 8 53-1/2 3/4 140 0.67
Tall 50 PROG50-42N RH67 PV 42 42.4 87 66-3/8 58 21-3/4 14 8 52-1/2 3/4 170 0.67
Tall 50 PROG50-42P RH67 PV 42 42.4 87 66-3/8 58 21-3/4 14 8 52-1/2 3/4 170 0.67
Short 40 PROG40S-36N RH67 PV 36 36.4 73 62-1/2 51-1/4 21-3/4 14 8 44-1/4 3/4 155 0.67
Short 40 PROG40S-32P RH67 PV 32 32.4 73 62-1/2 51-1/4 21-3/4 14 8 44-1/4 3/4 155 0.67
Short 50 PROG50S-36N RH67 PV 36 36.4 87 62-1/2 51-1/4 23-3/4 14 8 44 3/4 175 0.67
Short 50 PROG50S-32P RH67 PV 32 32.4 87 62-1/2 51-1/4 23-3/4 14 8 44 3/4 175 0.67
HOT
WATER
CONNECTION COLD
WATER
CONNECTION
POWER VENT
ASSEMBLY
C
BF
A
D
G
G
E
T&P FITTING
3/4" N.P. T.
1/2"
ANODE ROD
NUMBER OF MINIMUM MAXIMUM MAXIMUM
90° ELBOWS NUMBER PIPE PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH (FT.) LENGTH (FT.)
TERMINAL ELBOWS REq. (FT.) 0’ - 2000’ 2000’ - 7700’ *
One (1) None 4.0 44.0 24.0
One (1) One (1) 4.0 41.0 21.0
Two (2) None 4.0 38.0 18.0
Two (2) One (1) 4.0 35.0 15.0
Three (3) None 4.0 32.0 12.0
NUMBER OF MINIMUM MAXIMUM MAXIMUM
90° ELBOWS NUMBER PIPE PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH (FT.) LENGTH (FT.)
TERMINAL ELBOWS REq. (FT.) 0’ - 2000’ 2000’ - 7700’ *
One (1) None 5.0 95.0 75.0
One (1) One (1) 5.0 92.5 72.5
Two (2) None 5.0 90.0 70.0
Two (2) One (1) 5.0 87.5 67.5
Three (3) None 5.0 85.0 65.0






Maximum and Minimum Vent Lengths for 2” Vents Maximum and Minimum Vent Lengths for 3” Vents