Rheem Professional Classic Series Powered Damper Specification Sheet
2015-04-02
: Rheem Rheem-Professional-Classic-Series-Powered-Damper-Specification-Sheet-683513 rheem-professional-classic-series-powered-damper-specification-sheet-683513 rheem pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
Residential Gas INTEGRATED HOM E C O M F O RT Classic Professional Water Powered Damper Water Heaters The energy efficient Professional Classic™ Powered Damper gas water heaters meet or exceed the latest ENERGY STAR® requirements Efficiency • Exclusive air/fuel shut-off device • .67 - .69 EF • Maintenance free – no filter to clean • ENERGY STAR® rated • Disables the heater in the presence of flammable vapor accumulation Performance • FHR: 72 - 84 gallons • Recovery rate is up to 40.4 gallons at a 90 degree rise Self-Diagnostic System Combustion Shut-off System Flame Arrestor Plate • Electronic gas control for improved monitoring and service Low Emissions Maintenance Free • Eco-friendly burner, low NOx design • Meets 40 ng/J NOx requirements Longer Life Technology • Rheem exclusive R-Tech (resistored) anode rod provides long-lasting tank protection • 24 VAC flue damper, 110 VAC outlet required • Includes 9-foot cord, 3-prong plug • Standard Cat. I, double-wall, B-vent, 3" (4" adaptor included) What is a Powered Damper? The 24-volt powered flue damper is positioned atop the unit. It opens and closes automatically in response to gas-burner activity. When the combustion stops, it signals the damper to close, trapping the heat inside the flue and delivering more heat to the water. High Altitude Compliant • Certified to 10,100 ft. above sea level (50-gallon 50K Btu/h model certified to 5,999 feet above sea level) Plus… • Dual certified for both potable water and space heating • Enhanced flow brass drain valve • Temperature and pressure relief valve included Professional Classic Powered Damper 38, 40 and 50-Gallon Capacities Up to 40,000 Btu/h Natural and LP Gas • Low lead compliant • Standard replacement parts Warranty LEED Point = 1 • 6-Year limited tank and parts warranty* *See Residential Warranty Certificate for complete information Guardian System™ & Sensor See dimensions chart on back. IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 01/14 WP FORM NO. PROG RHPDCAN Residential Gas INTEGRATED HOME C O M F O RT Classic Professional Water Powered Damper Water Heaters Professional Classic™ Power Dampered Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. T HT. TO WATER HT. TO WATER GAS INPUT IN RECOVERY IN FIRST HOUR Y HT. TO TANK GAS VENT CONN. SIDE T&P CONN. SHIP. ENERGY THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. P GAL. MODEL VENT HT. DIAM. CONN. SIZE CNTR. VALVE SIZE WT. FACTOR E CAP. NUMBER NAT. LP NAT. LP NAT. A B C D E F G H (LBS) NAT. AVG. ANN. OPERATING COST NAT. Short 40 PROG40S-40N CN67 PD 40 36 40.4 36.4 72 55-1/2 50-1/2 21-3/4 14 3 or 4 8 44 3/4 140 0.67 $272 Short 50 PROG50S-40N CN67 PD 40 36 40.4 36.4 89 55-1/2 50-1/2 23-3/4 14 3 or 4 8 44 3/4 160 0.67 $272 Tall 38 PROG40T-40N CN69 PD 40 36 40.4 36.4 68 62-3/4 57-3/4 19-3/4 14 3 or 4 8 52-1/4 3/4 140 0.69 $264 Tall 50 PROG50T-40N CN67 PD 40 36 40.4 36.4 84 14 3 or 4 8 52-1/2 3/4 160 0.67 $268 63 58 21-3/4 Specify LP when ordering. Add gas input and "P' to the model number. Example: PROG40S-36P CN67 PD ANODE ROD H H HOT WATER CONNECTION F E COLD WATER CONNECTION 3/4" N.P.T. RELIEF VALVE OPENING C A B 1/2" G D In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • www.rheem.com IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 01/14 WP FORM NO. PROG RHPDCAN
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2014:01:21 13:26:23-06:00 Metadata Date : 2014:01:21 13:26:25-06:00 Modify Date : 2014:01:21 13:26:25-06:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:4cc04150-190d-3144-8800-f01161dd316d Original Document ID : xmp.did:0A80117407206811B34BA559CEB6FCA7 Document ID : xmp.id:991B775B0C206811822AB67D43C0925C Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:981B775B0C206811822AB67D43C0925C Derived From Document ID : xmp.did:981B775B0C206811822AB67D43C0925C Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:01:21 13:26:23-06:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools