Rheem Professional Prestige Series 90 Outdoor Specification Sheet
Rheem-Professional-Prestige-Series-95-Direct-Vent-Indoor-Specification-Sheet-683400 rheem-professional-prestige-series-95-direct-vent-indoor-specification-sheet-683400
Rheem-Professional-Prestige-Series-84-Direct-Vent-Indoor-Specification-Sheet-683420 rheem-professional-prestige-series-84-direct-vent-indoor-specification-sheet-683420
Rheem-Professional-Prestige-Series-95-Outdoor-Specification-Sheet-683407 rheem-professional-prestige-series-95-outdoor-specification-sheet-683407
Rheem-Professional-Prestige-Series-90-Direct-Vent-Indoor-Specification-Sheet-683414 rheem-professional-prestige-series-90-direct-vent-indoor-specification-sheet-683414
2015-04-02
: Rheem Rheem-Professional-Prestige-Series-90-Outdoor-Specification-Sheet-683416 rheem-professional-prestige-series-90-outdoor-specification-sheet-683416 rheem pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Residential Gas INTEGRATED HOME COMFORT Water Prestige RTGH Tankless Water Heaters Rheem Prestige™ RTGH is a series of high efficiency condensing tankless gas water heaters designed for continuous hot water Efficiency High-Altitude Compliant • Up to .94 EF with stainless steel condensing heat exchanger • Intelligent electronic controls designed to increase energy efficiency and safety • Third party efficiency listed by AHRI • High-altitude capability – up to 9,840 ft. elevation above sea level Performance • Industry First! 0.26 GPM minimum flow rate, 0.40 GPM minimum activation flow rate • SCAQMD rule 1146.2 compliant • RTGH-95 for 3 bathroom homes*– 9.5 gal./min. at 35°F rise max., 8.4 gal./min. at 45°F rise • RTGH-90 for 2-3 bathroom homes*– 9.0 gal./min. at 35°F rise max., 7.5 gal./min. at 45°F rise •R TGH-84 for 2-3 bathroom homes*– 8.4 gal./min. at 35°F rise max., 6.6 gal./min. at 45°F rise Compact Size • Compact space-saving design – about the size of a medicine cabinet Self-Diagnostic System • Self-diagnostic system for easy installation and service. • Digital display shows temperature setting and maintenance codes Technology • Two-pipe direct vent system designed for PVC pipe (up to 38 ft. of 3" PVC Pipe or 5 ft. of 2" PVC Pipe). See instructions for details • Hot-start programming helps m inimize fluctuation in water temperature, referred to as “cold water sandwich effect,” during periods of frequent on/ off operation •B uilt-in electric blower •E xclusive! Guardian OFW™ overheat film wrap • EZ-Link™ cable available for higher demand applications to connect two tankless units to operate as one •M anifold up to six units with an optional MIC-6 manifold control board •M anifold up to 20 units with the optional MIC-185 plus the MICS-180 manifold control assembly Plus… • Digital remote control and 10 ft. of thermostat wire included • Supplied with a 120-volt power cord (indoor models only) • Freeze protection to -30°F • Required manual gas isolation valve included • EZ- Spec™ Sizing Software – advanced online tool that takes the guess work out of sizing tankless applications – available at www.rheem.com/tankless Warranty • 12-Year heat exchanger – residential, 5-yearheat exchanger – commercial, 5-year parts and 1-year labor 5 ProClub Points RTGH-DVL Indoor Direct Vent Model 11,000-199,900 Btu/h Natural and LP Gas See Warranty Certificate for c omplete information Commercial Applications The RTGH Condensing Tankless Series can be upgraded for hightemperature commercial use. • Temperature range is 85°F to 185°F RTGH-95 Upgrade Kits RTG20240A for RTGH-95DVLN RTG20240B for RTGH-95DVLP RTG20240C for RTGH-95XLN RTG20240D for RTGH-95XLP RTGH-90 Upgrade Kits RTG20244A for RTGH-90DVLN RTG20244B for RTGH-90DVLP RTG20244C for RTGH-90XLN RTG20244D for RTGH-90XLP RTGH-84 Upgrade Kits 5 ProClub Points RTGH-XL Outdoor Model 11,000-199,900 Btu/h Natural and LP Gas RTG20241A for RTGH-84DVLN RTG20241B for RTGH-84DVLP RTG20241C for RTGH-84XLN RTG20241D for RTGH-84XLP Note: These upgrade kits are not compatible with previous models. See the Tankless Parts and Accessories Catalog for a complete listing. * Based on simultaneous showers using 2.5 gallons per minute. Flow rates vary depending on temperature of cold water supply. LEED Points = 2 myrheem.com/proclub IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 10/14 WP FORM NO. TK-806 REV. 6 Residential Gas INTEGRATED HOME COMFORT Water Prestige RTGH Tankless Water Heaters Rheem Prestige™ Specifications DESCRIPTION FEATURES GAS MODEL INPUT TEMP. NUMBER BTU/H TYPE RANGE MIN. FLOW/ GPM @ ACTIVATION 77° RISE GPM MAX. ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. GPM @ SHIP. EST. YEARLY CONNECTION 45° RISE MAX. VENT WEIGHT ENERGY Recovery ENERGY cost MAX. GPM WATER GAS HEIGHT WIDTH DEPTH DIAM. (LBS.) FACTOR EFFICIENCY NAT/LP Rheem Prestige™ RTGH-95 for 3 Bathroom Homes RTGH-95DVLN 11,000- Indoor 85° to 0.26/0.40 4.9 8.4 9.5 3/4 3/4 27-1/2 18-1/2 9-3/4 2” or 3” 140° F PVC 2-Pipe 199,900 Direct Vent 82 .94 94% $174/421 RTGH-95XLN 11,000- Outdoor 85° to 0.26/0.40 4.9 8.4 9.5 3/4 3/4 27-1/2 18-1/2 9-3/4 199,900 140° F 82 .94 94% $174/421 N/A Rheem Prestige™ RTGH-90 for 2-3 Bathroom Homes RTGH-90DVLN 11,000- Indoor 85° to 0.26/0.40 4.4 7.5 9 3/4 3/4 27-1/2 18-1/2 9-3/4 2” or 3” 140° F PVC 2-Pipe 180,000 Direct Vent 82 .93 93% $176/425 RTGH-90XLN 11,000- Outdoor 85° to 0.26/0.40 4.4 7.5 9 3/4 3/4 27-1/2 18-1/2 9-3/4 180,000 140° F 82 .93 93% $176/425 N/A Rheem Prestige™ RTGH-84 for 2-3 Bathroom Homes RTGH-84DVLN 11,000- Indoor 85° to 0.26/0.40 3.9 6.6 8.4 3/4 3/4 27-1/2 18-1/2 9-3/4 2” or 3” 140° F PVC 2-Pipe 157,000 Direct Vent 82 .92 92% $178/430 RTGH-84XLN 11,000- Outdoor 85° to 0.26/0.40 3.9 6.6 8.4 3/4 3/4 27-1/2 18-1/2 9-3/4 157,000 140° F 82 .92 92% $178/430 Estimated energy cost based on a national average fuel cost of $1.09/therm for natural gas and $2.41/gallon for LP. Energy factor determined by the U.S. Department of Energy (DOE) test procedures. All models are available in Natural Gas and Propane (LP). For Propane replace the N with P when ordering. • SCAQMD 1146.2 compliant. • Factory set maximum temperature is 120° F. See Use and Care Manual for setting. • Consult factory for information on sizing the application. • Add a "C" to the model number when ordering Canadian models. Outdoor models are only for seasonal use in Canada. Please contact Rheem Canada Ltd. for details. Vent Termination Kits are required for Direct Vent models. Contact your distributor for details. Proper gas pressure must be ensured to supply tankless gas water heaters – up to 199,900 Btu/h for RTGH-95 models, up to 180,000 Btu/h for RTGH-90 models, up to 157,000 Btu/h for RTGH-84 models. (Consult your gas supplier) Temperature Rise (° F) Model Number 35° 45° 50° 60° 70° 77° 80° 90° 100° RTGH-95 Water Flow (GPM) 9.5 8.4 7.6 6.3 5.4 4.9 4.7 4.2 3.8 RTGH-90 Water Flow (GPM) 9.0 7.5 6.8 5.6 4.8 4.4 4.2 3.8 3.4 RTGH-84 Water Flow (GPM) 8.4 6.6 6.0 5.0 4.3 3.9 3.7 3.3 3.0 N/A Indoor Direct Vent 5 1/2” 6 1/4” 27 1/2” 18 1/2” 9 3/4” Above estimates are for sizing purposes only. Maximum Vent Length (intake/outlet): Water Heater Flow Rate Curves GPM 10 9 8 H95 Max Flow H90 Max Flow 7 H84 Max Flow 6 5 4 3 2 1 0 10 20 35 45 50 60 70 Delta-T Parts and Accessories 77 80 90 100 120 140 Maximum Maximum Length Length Number of 2" of 3" of 90° Straight Straight Elbows Pipe Pipe 0 or 1 5.0 ft. 38.0 ft. (1.5 m) (11.6 m) 2 3.5 ft. 36.5 ft. (1.0 m) (11.1 m) 3 2.0 ft. 35.0 ft. (0.6 m) (10.6 m) 4 Not 33.5 ft. Available (10.2 m) 5 Not 32.0 ft. Available (9.8 m) 6 Not 30.5 ft. Available (9.3 m) 4 1/4” 3 1/4” 3 1/2” 7 1/2” For more information on Tankless parts and accessories, see the Parts and Accessories Catalog or call 866-720-2076. 2 3/4” 6 3/4” Outdoor 27 1/2” (ULCs636 pipe must be used for Canada.) Venting & terminations – 2” or 3” PVC, recess boxes, pipe covers, extra remote controls, EZ-Link™ cable, manifolds and cables, service valve kits, service parts and flush kits. 2 1/2” 2 3/4” 18 1/2” 9 3/4” 4 1/4” 3 1/4” 2 1/2” 2 3/4” 2 3/4” 3 1/2” 6 3/4” 7 1/2” In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • www.rheem.com IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT 2 PRINTED IN U.S.A. 10/14 WP FORM NO. TK-806 REV. 6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2014:10:24 15:17:52-05:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2014:10:28 10:02:50-05:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:10:28 10:02:50-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:09b413a7-0a0a-5f4e-b61e-7e3f2ed8ca99 Original Document ID : xmp.did:0A80117407206811B34BA559CEB6FCA7 Document ID : xmp.id:ED4F58CABF2568118083B71C87E59B3A Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:EC4F58CABF2568118083B71C87E59B3A Derived From Document ID : xmp.did:6CA94A75232068119109DEA12E3D43A5 Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:10:24 15:17:52-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools