Rheem Tankless Electric Rte 18 Specification Sheet
Rheem-Tankless-Electric-Rte-7-Specification-Sheet-683584 rheem-tankless-electric-rte-7-specification-sheet-683584
Rheem-Tankless-Electric-Rte-9-Specification-Sheet-683574 rheem-tankless-electric-rte-9-specification-sheet-683574
Rheem-Tankless-Electric-Rte-3-Specification-Sheet-683594 rheem-tankless-electric-rte-3-specification-sheet-683594
Rheem-Tankless-Electric-Rte-13-Specification-Sheet-683563 rheem-tankless-electric-rte-13-specification-sheet-683563
2015-04-02
: Rheem Rheem-Tankless-Electric-Rte-18-Specification-Sheet-683552 rheem-tankless-electric-rte-18-specification-sheet-683552 rheem pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
Residential Electric INTEGRATED H O M E C O M F O RT Water Tankless Water Heaters Tankless electric water heaters offer continuous hot water quick and on demand for point-of-use applications RTE 3 RTE 7 Features Applications • Continuous hot water on demand • Homes • Restaurants • Industry leading low-flow activation • Apartments • Offices • External temperature control • Condos • Laboratories • LEDs indicate active element and standby mode • Hospitals • Anywhere hot water is needed • 1/2-Inch water connections • Rest rooms RTE 9 RTE 13 • Rugged brass/copper heat exchanger Warranty • Pre-wired 2-foot power supply cord(s) included • 10-Year limited heat exchanger and 1-Year limited parts w arranty.* Efficiency *See Residential Warranty Certificate for complete information. • Modulating heat exchanger improves energy efficiency • No standby heat loss aids in energy consumption • No venting needed - eliminates greenhouse gases Easy Installation • Complete install without removing the cover • Easy water connections using 1/2-inch compression fittings • Lightweight Space Savings • No T&P valve required • Compact size - fits almost anywhere RTE 3 and RTE 7 • Ideal for fast, continuous hot water at a single point-of-use faucet or other fixture • RTE 3 (3kW/120V) requires a dedicated 30 AMP breaker • RTE 7 (7kW/240V) requires a dedicated 30 AMP breaker RTE 9 and RTE 13 6, 10, 15, 20 and 30-Gallon RTE 18 RTE 27 RTE Tankless 3 kW to 27 kW 120 and 240 Volt AC Electric • Ideal for fast, continuous hot water at a lavatory or sink • RTE 9 (9kW/240V) requires a dedicated 40 AMP breaker • RTE 13 (13kW/240V) requires a dedicated 60 AMP breaker RTE 18 and RTE 27 • Designed for fast, continuous hot water in a bathroom addition/ renovation or single shower • RTE 18 (18kW/240V) requires two dedicated 40 AMP breakers • RTE 27 (27kW/240V) requires two dedicated 60 AMP breakers All come with an on-unit temperature control with LED lights IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 12/14 WP FORM NO. TK-205 Rev. 5 Residential Electric INTEGRATE D H O M E C O M F O RT Water Tankless Water Heaters Rheem Tankless Electric Specifications Application Flow Rate in GPM at 60 PSI Typical Shower 2.0 GPM Typical Bath Tub Faucet 2.5 GPM Bathroom Vanity Sink Faucet 1.0 GPM Kitchen Sink Faucet 1.5 GPM Washer 2.0 GPM Water Temperature and Flow Rate Required Flow Rate in Gallons Per Minute Ground 1 1.5 2 2.5 3 3.5 4 4.5 5 Water Temperature Suggested EcoSense Model (kW) 35 40 13 18 27 27 9 13 18 27 27 45 9 13 18 27 27 27 50 9 13 18 27 27 27 55 7 9 13 18 27 27 27 27 60 7 7 9 18 18 27 27 27 65 7 7 9 13 18 18 18 27 70 7 7 9 13 13 18 27 27 27 75+ 3 7 7 9 18 18 18 27 27 Recommendations based on hot outlet water temperature of 105°F. Dimensions (inches/pounds) Model HEIGHT width DEPTH weight RTE 3 10-1/4 5-3/8 3-1/4 RTE 7 10-1/4 5-3/8 3-1/4 6 6 RTE 9 10 7-1/4 3-1/4 8 RTE 13 10 7-1/4 3-1/4 8 RTE 18 10-1/2 11-1/4 3-1/4 12 RTE 27 10-1/2 11-1/4 3-1/4 12 • Plumbing connections: 1/2 NPT • Minimum flow rate: 1/2 gal. min Electrical Specifications Model Kw VOLTS REcommended MAX POWER BREAKER Size (AMP) AWG WIRE RTE 3 3 120 30 29 10 RTE 7 7 240 30 29 10 RTE 9 9 240 40 38 8 RTE 13 13 240 60 54 6 RTE 18 18 240 (2) 40 75 (2) 8 RTE 27 27 240 (2) 60 112 (2) 6 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • www.rheem.com IINNTTEEGGRAT ED MO FO RAT E DH OHM OEMCEOC MRT F O RT PRINTED IN U.S.A. 12/14 WP FORM NO. TK-205 Rev. 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2014:12:10 10:17:51-06:00 Metadata Date : 2014:12:10 10:17:56-06:00 Modify Date : 2014:12:10 10:17:56-06:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:df3f4c9e-e4eb-ad4d-ad15-782b9e6a8431 Original Document ID : xmp.did:0A80117407206811B34BA559CEB6FCA7 Document ID : xmp.id:B3729471C22368118083929DE914427B Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:B2729471C22368118083929DE914427B Derived From Document ID : xmp.did:2BFE14CA2720681195FED2B0B0EBCDF4 Derived From Original Document ID: xmp.did:0A80117407206811B34BA559CEB6FCA7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:12:10 10:17:51-06:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools