Rheem Value Series Single Stage Submittal Sheet
2015-04-02
: Rheem Rheem-Value-Series-Single-Stage-Submittal-Sheet-683706 rheem-value-series-single-stage-submittal-sheet-683706 rheem pdf
Open the PDF directly: View PDF .
Page Count: 3
Download | |
Open PDF In Browser | View PDF |
SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg. Evaporator Heating Input Heating Output CFM/ESP EER/SEER Electrical Minimum Ampacity Min.-Max. Breaker Net Unit Weight Accessory Catalog Form Number ACCESSORIES: NOTES: PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640 FORM NO. X33-1420 Supersedes Form No. X66-1253 Rev. 1 SUBMITTAL SHEET FOR 13PJL SERIES 11/2 TO 5 NOMINAL TON [5.28 TO 17.58 kW], UP TO 14.5 SEER HEAT PUMP UNITS JOB NAME LOCATION CONTRACTOR ORDER NO. ENGINEER UNIT MODEL NO. SUBMITTED FOR APPROVAL DATE RECORD COIL MODEL NO. AIR HANDLER MODEL NO. FEATURES FOR 13PJL SERIES HEAT PUMP UNITS 11/2 TO 5 NOMINAL TON [5.28 TO 17.58 kW] UNIT DATA COOLING PERFORMANCE EFFICIENCY .................................. _______ SEER TOTAL CAPACITY*.................... _______ MBH [kW] SENSIBLE CAPACITY* .............. _______ MBH [kW] OUTDOOR DESIGN TEMP. ........ _______ °F [°C] DB TEMP. OF AIR ENTERING EVAPORATOR COIL .............. _______ °F [°C] DB _______ °F [°C] WB • Outdoor heat pump designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial applications. • Painted louvered steel cabinet • Easily accessible control box • Condenser coils constructed with copper tubing and enhanced aluminum fins. • Grille/Motor mount for quiet fan operation • Filter Drier (shipped – not installed) POWER INPUT REQUIREMENT .......... _______ kW (*uses blower motor heat) HEATING PERFORMANCE ACCESSORIES/OPTIONS EFFICIENCY .................................. _______ HSPF TOTAL CAPACITY*.................... _______ MBH [kW] OUTDOOR DESIGN TEMP. ........ _______ °F [°C] DB TEMP. OF AIR ENTERING EVAPORATOR COIL .............. _______ °F [°C] DB SUPPLY AIR BLOWER PERFORMANCE TOTAL AIR SUPPLY .................. _______ CFM [L/s] TOTAL RESISTANCE EXTERNAL TO UNIT........................................ _______ IWG BLOWER SPEED.............................. _______ RPM POWER OUTPUT REQUIREMENT .... _______ BHP MOTOR RATING .......................... _______ HP [W] POWER INPUT REQUIREMENT .......... _______ kW ELECTRICAL DATA POWER SUPPLY .......................... ___________ Hz TOTAL UNIT AMPACITY.................. _______ AMPS MINIMUM WIRE SIZE ...................... _______ AWG MAXIMUM OVERCURRENT DEVICE FUSES/HACR BREAKER ............ _______ AMPS CLEARANCES ACCESS SIDE 24" [609.6 mm] AIR INLETS 12" [304.8 mm] ABOVE UNIT 60" [1524 mm] Outdoor Thermostats (Model No. RXPT-A01, A02, A03, A04) .. High Pressure Control (Model No. RXAB-A07) .......................... Low Ambient Control (Model No. RXAD-A07)............................ Compressor Time Delay Control (Model No. RXMD-B01) ........ Blower Time Delay Control (Model No. RXMD-C04).................. Sound Enclosure* ...................................................................... Heat Pump Monitor (Model No. RXPM-B01) .......................... Thermostats and Subbases* Start Components* *Available through the Replacement Parts Division 13PJL 18, 24, 30, 36, 42, 48, 60 w L H SEE DETAIL A Model Number 13P(-)L 18, 24 Height “H” (Inches) [mm] 261/4 [666.75] Length “L” (Inches) [mm] 235/8 [600.07] Width “W” (Inches) [mm] 235/8 [600.07] 30 261/4 [666.75] 275/8 [701.67] 275/8 [701.67] 36 42, 48, 60 273/8 [695.32] 353/8 [898.52] 315/8 [803.27] 315/8 [803.27] 315/8 [803.27] 315/8 [803.27] [ ] Designates Metric Conversions NOTES: Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 6-14 QG FORM NO. X33-1420 Supersedes Form No. X33-1155 Rev. 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Create Date : 2014:06:05 13:27:03-05:00 Modify Date : 2014:06:05 15:58:11-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Title : untitled Metadata Date : 2014:06:05 15:58:11-05:00 Producer : Acrobat Distiller 10.0.0 (Macintosh) Document ID : uuid:3414cae3-baf9-0349-a417-a78ae0bb8161 Instance ID : uuid:d2987272-c7e6-1748-8b1b-92fc2aad3949 State : 1 Version : 1.1 Page Count : 3 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools