Rinnai Rur98I Reu Kbp3237Ffud Us Specification Sheet
2015-05-15
: Rinnai Rinnai-Rur98I-Reu-Kbp3237Ffud-Us-Specification-Sheet-719851 rinnai-rur98i-reu-kbp3237ffud-us-specification-sheet-719851 rinnai pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
RUR98i (KBP3237FFUD) Type of Appliance Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system with built in recirc pump, Energy Star Qualified Rinnai model number REU-KBP3237FFUD-US Operation / Installation Forced combustion; indoor only; Certified for installation in Manufactured (Mobile) Homes Minimum/Maximum Gas Rate (Input) 15,200 - 199,000 BTU/h (4.5-58.3 kW) Electrical Appliance: Temperature Controller: Electrical Consumption Normal: 205 w Standby: 3 w Anti-frost protection: 150 w Amperage Max: 8A Fuse: 10A Ignition System Direct electronic ignition Hot Water Capacity Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM 1.5 l/min) Maximum flow rate: 9.8 GPM (37.1 l/min) Temperature 98° - 120° F (37°- 49°C) (factory default) Maximum temperature is selectable at 120° F (49°C) or at 140° F (60°C); Temperature (without remote) 120° F (49°C) (factory default) or 140° F (60°C) Approved Gas Types Natural or Propane (ensure unit matches gas type) Energy Factor (EF) Natural Gas: 0.95 Service Connections Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT Isolation & Pressure Relief Valves Included Heavy duty forged brass Isolation valves EXP E2, certified to NSF/ANSI 618 for potable water Water Flow Control Water flow sensor, electronic water control and by-pass control Minimum/Maximum Water Supply Pressure 50 - 150 PSI (345-1035 KPa) (60 - 80 PSI (414 - 552 KPa) or above is recommended for maximum flow) AC 120 Volts - 60 Hz DC 12 Volts Propane: 0.95 Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE (37.9) 10.0 10.0 Water Flow gpm (l/min) (34.1) 9.09.0 (30.3) 8.08.0 (26.5) 7.07.0 (22.7) 6.06.0 (19.0) 5.05.0 kA3237 (15.1) 4.04.0 (11.4) 3.03.0 (7.6) 2.02.0 (3.8) 1.01.0 0.0 0.0 0 25 (13.9) 25 50 (27.8) 50 75 (41.6) 75 100 (55.6) 100 delta T - Temperature Rise ºF (ºC) © 2014 Rinnai America Corporation RUR98i-SP 9/2014 125 (69.4) 125 150 (83.3) 150 RUR98i (KBP3237FFUD) Internal Recirculation Pump Control Built in Rinnai Circ-Logic™ : Recirculation program cycles internal pump Controller MC-195T-US (included)-Pump Timer Control, MC-91-2US (optional) Maximum Recirculation Pipe Lengths Dedicated Return -Total length includes both hot water supply lines and Dedicated Return line Cross Over Mode -Cross over mode requires use of included thermal by-pass valve -Total length includes both hot water supply and cold water piping length from the tankless to thermal by-pass valve 400ft for 3/4” pipe diameter 100ft for 1/2” pipe diameter Controller Cable Non-polarized two-core cable, minimum 22 AWG Safety Devices Remaining flame (OHS) Thermal fuse Automatic frost protection Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse * 24 inches (609.6mm) required for service Top of heater - 6 inches (152.4mm) Front of heater - 6 inches *(152.4mm) Sides of heater - 2 inches (50.8mm) Back of heater - 0 inches Bottom of heater - 12 inches (304.8mm) From vent pipe - 0 inches Clearances from Non-combustibles * 24 inches (609.6mm) required for service Top of heater - 2 inches (50.8mm) Front of heater - 6 inches *(152.4mm) Sides of heater - 1/2 inches (12.7mm) Back of heater - 0 inches Bottom of heater - 12 inches (304.8mm) From vent pipe - 0 inches Clearances from Combustibles Min. / Max. Gas Supply Pressure Natural Gas: Propane Gas: min 4” W.C. (2.5mbar) min 8” W.C. (20mbar) Manifold Gas Pressure (inches W.C.) Natural Gas: Propane Gas: high fire 3.0” W.C. (7.5mbar) low fire 0.42” W.C. (1.1mbar) high fire 3.5” W.C. (8.7mbar) low fire 0.47” W.C. (1.2mbar) NOx Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Direct Vent system designed for use with Ubbink Polypropylene Concentric Vent, Twin Pipe PVC/CPVC (3” and 4” configurations), or Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adapter) See installation and operation manual for details regarding installation and allowed vent lengths. Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information. WEIGHT: 72.8 lb (33 kg) DIMENSIONS ø 5.5 (140.2) 5.9 (150) 10.1 (257.7) J 25.7 (654) 28.5 (723.3) 31.2 (791.3) 29.8 (756.3) 1.2 (31.2) 2.02 (51.3) Limited Warranty max 10.5” W.C. (26.1mbar) max 13.5” W.C. (33.6mbar) 2.8 (70.1) 8.7 (222) DIMENSION Inches (mm) DIMENSION Inches (mm) A (GAS) 1.6 (40.2) E 4.6 (116.8) A (COLD) 2.0 (50.2) F 2.3 (57.7) A (HOT) 1.4 (36.4) G 1.9 (47.8) B 5.0 (127.2) H 0.52 (13.3) C 7.1 (179.7) I 18.3 (466) D 0.60 (15.3) J 7.2 (181.5) A Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 Language : en-US Tagged PDF : Yes Author : Jose Torres Create Date : 2014:11:05 08:56:45-05:00 Modify Date : 2014:11:05 08:56:45-05:00 Producer : Microsoft® Publisher 2010 Creator : Microsoft® Publisher 2010EXIF Metadata provided by EXIF.tools