Rinnai Submittal Sheet Msb Electronic Control Miscellaneous
2015-05-15
: Rinnai Rinnai-Submittal-Sheet-Msb-Electronic-Control-Miscellaneous-719972 rinnai-submittal-sheet-msb-electronic-control-miscellaneous-719972 rinnai pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
MSB ELECTRONIC CONTROLS AND EZ CONNECT SUBMITTAL SHEET Job Name: Location: Architect/Engineer: Wholesaler: Number of Heaters: BTU/Hr Input: Notes: FEATURES AND BENEFITS • Modulating technology witih up to 327:1 Turndown (25 units with MSB electronic controls) •T he temperature setting for all of the connected water heaters is controlled by the temperature controller connected to the • 15,200 Btuh to 5 Million Btuh water heater with the Master MSB Board. Temperature controllers • 0.26 gpm to 245 gpm hot water flow range connected to the other units will provide maintenance codes for their • Each MSB-M board will connect up to 5 water heaters using the MSB-C1 kits. • Up to 5 MSB-M boards can be connected together with communication cables (MSB-C2 kits) allowing up to 25 water heaters to operate as a single system. • When multiple water heaters are operating, they will attempt to supply equal amounts of hot water. respective units. • If a water temperature over 140 degree F is desired, then an MCC-912 controller needs to be connected to Master Control Board. •T he order in which each water heater operates is occasionally rotated to ensure equal usage among the entire system. •D etailed installation instructions are provided with each of the kits. NOTE: For tankless only systems, reference MSB installation instructions to ensure distance between racks do not exceed MSB communication cable length. * The Rinnai EZConnect™ is specifically designed for connecting only 2 water heaters. OPTIONS MSB-M Kit MSB-C1 Kit MSB-C2 Kit EZ-Connect™ Rinnai America Corporation • 103 International Drive Peachtree City, GA 30269 • 800-621-9419 TANKLESS RACK SYSTEM (TRS) MSB Control System and EZConnect • Each MSB-M board will connect up to 5 water heaters using the MSB-C1 kits. • Up to 5 MSB-M boards can be connected together with communication cables (MSB-C2 kits) allowing up to 25 water heaters to operate as a single system. No. of water heaters 2* 1 NA NA An MSB system could have an operating range of 15,200 BTU to as great as 5 million BTU. In terms of flow rate, 0.4 gpm to 245 gpm. 3 1 1 NA 4 1 2 NA 5 1 3 NA 6 2 2 1 7 2 3 1 8 2 4 1 9 2 5 1 10 2 6 1 11 3 5 2 12 3 6 2 13 3 7 2 14 3 8 2 15 3 9 2 16 4 8 3 17 4 9 3 18 4 10 3 19 4 11 3 20 4 12 3 21 5 11 4 22 5 12 4 23 5 13 4 24 5 14 4 25 5 15 4 • • • • • • Number of Components Required When multiple water heaters are operating, they will attempt to supply equal amounts of hot water. The temperature setting for all of the connected water heaters is controlled by the temperature controller connected to the water heater with the Master MSB Board. Temperature controllers connected to the other units will provide maintenance codes for their respective units. If a water temperature over 140 degree F is desired, then an MCC-91-2 controller needs to be connected to Master Control Board The order in which each water heater operates is occasionally rotated to ensure equal usage among the entire system. Detailed installation instructions are provided with each of the kits. NOTE: For tankless only systems, reference MSB installation instructions to ensure distance between racks do not exceed MSB communication cable length. * The Rinnai EZConnect™ is specifically designed for connecting only 2 water heaters. MSB-M kit includes MSB-C1 kit includes MSB-M MSB-C1 MSB-C2 MSB-C2 kit includes • Control board • Cable B (9.8 ft, 3 m) • MSB Cable (13.1 ft, 4 m) • Cable A (23 in, 585 mm) • Brackets, ties, and screws • Terminal connectors • Cable B (9.8 ft, 3 m) • Instructions • Instructions • Brackets, ties, and screws • Instructions Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 11 SP-TRS
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2012:11:06 15:37:52-05:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2012:11:06 15:41:52-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2012:11:06 15:41:52-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:128494e2-1a7e-a647-a572-0958ac52eb65 Original Document ID : xmp.did:69C154110A2068118083AA20B4D09132 Document ID : xmp.id:45E9624F26206811BB1D9B78C28A5EA4 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:44E9624F26206811BB1D9B78C28A5EA4 Derived From Document ID : xmp.did:58F965F7152068118083801703705392 Derived From Original Document ID: xmp.did:69C154110A2068118083AA20B4D09132 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2012:11:06 15:37:52-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False State : 1 Version : 1.1 Page Count : 2 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools