Risco RWT6F915 WL Flood Detector 915 MHz User Manual 5IN2583 WL Flood Detector

Risco Ltd. WL Flood Detector 915 MHz 5IN2583 WL Flood Detector

User manual

Download: Risco RWT6F915 WL Flood Detector 915 MHz User Manual 5IN2583 WL Flood Detector
Mirror Download [FCC.gov]Risco RWT6F915 WL Flood Detector 915 MHz User Manual 5IN2583 WL Flood Detector
Document ID3083410
Application IDNfkZvuhGLREffeiaQjtP3A==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize8.35kB (104361 bits)
Date Submitted2016-08-01 00:00:00
Date Available2016-08-01 00:00:00
Creation Date2016-07-11 14:37:46
Producing SoftwareGPL Ghostscript 9.06
Document Lastmod2016-07-11 14:37:46
Document TitleMicrosoft Word - 5IN2583 WL Flood Detector
Document CreatorPScript5.dll Version 5.2.2
Document Author: Motti_B

WIRELESS FLOOD DETECTOR
Model: RWT6F
Installation instructions
Remove the plastic wrapping from the batteries before installation
and make sure the cover is removed so the internal tamper switch is
accessible.
Send a signal transmission from the detector by pressing the tamper
button for at least 2 seconds; the control panel beeps once to accept
or beeps three times to reject. Once accepted, the system
announces the device type and its zone (for example, “Detector,
zone 1”).
When the detectors have been enrolled, short-press the control
to exit Learn mode; the unit beeps once and the
panel button
LEDs stop flashing.
Note: For future use, it is recommended to write down the detector
description, zone number, and installation location of each allocated
detector.
4 Installation
1 General Description
The wireless flood detector is a fully supervised detector used to
detect the presence of water based liquids at any desired location
such as basements or water tanks.
The detector is comprised from 2 parts: Wireless transmitter and
flood sensor which are connected by 2.4m cable.
The detector operates with RISCO Group's programmable wireless
receivers.
2 LED Indication
On: The LED turns on each time the detector transmits (alarm,
tamper or supervision). Blink: Low battery condition. The LED will
blink on each transmission.
3 Quick Device Allocation at the Control Panel
The detector is automatically programmed to your control panel
during the on-line installation wizard setup. If you later purchase an
extra detector you can enroll it as follows:
To quickly allocate the detector at the control panel:
If the control panel is not already in Learn mode, press the
button on the control panel for 5 seconds; the unit beeps once
as it enters Learn mode (all the LEDs also light up, one after the
other).
Select a mounting location that is suitable both for the transmitter
and the flood sensor as follows:
Transmitter Mounting Location:
• Place the transmitter at the highest possible position to improve
communication and prevent from coming wet in the event of
flooding.
• Test the transmitter's communication quality by generating an
alarm and verifying that the receiver has received it. If the alarm
signal is not detected, reposition the transmitter and try again.
Flood Sensor Mounting location:
The flood sensor should be placed in a position where water will
accumulate rapidly in an event of flooding.
After selecting the mounting location:
1. Attach the flood sensor in horizontal position near the floor with
using the double-sided adhesive.
2. Secure the flood sensor cable to the wall. (Note: It is
recommended to place the flood sensor cable inside metal or
plastic pipe).
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from
defects in materials and workmanship under normal use for 24 months from the date of
production. Because Seller does not install or connect the product and because the product may
be used in conjunction with products not manufactured by the Seller, Seller can not guarantee
the performance of the security system which uses this product. Sellers' obligation and liability
under this warranty is expressly limited to repairing and replacing, at Sellers option, within a
reasonable time after the date of delivery, any product not meeting the specifications. Seller
makes no other warranty, expressed or implied, and makes no warranty of merchantability or of
fitness for any particular purpose. In no case shall seller be liable for any consequential or
incidental damages for breach of this or any other warranty, expressed or implied, or upon any
other basis of liability whatsoever. Sellers obligation under this warranty shall not include any
transportation charges or costs of installation or any liability for direct, indirect, or not be
compromised or circumvented; that the product will prevent any persona; injury or property loss
by intruder, robbery, fire or otherwise; or that the product will in all cases provide adequate
warning or protection. Buyer understands that a properly installed and maintained alarm may
only reduce the risk of intruder, robbery or fire without warning, but is not insurance or a guaranty
that such will not occur or that there will be no personal injury or property loss as a result.
Consequently seller shall have no liability for any personal injury, property damage or loss based
on a claim that the product fails to give warning. However, if seller is held liable, whether directly
or indirectly, for any loss or damage arising from under this limited warranty or otherwise,
regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the
product, which shall be complete and exclusive remedy against seller. No employee or
representative of Seller is authorized to change this warranty in any way or grant any other
warranty.
WARNING: This product should be tested at least once a week.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to local regulations.
FCC ID: JE4RWT6F915
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation
Changes or modifications to this equipment which are not expressly approved by
the party responsible for compliance (RISCO Group's.) could void the user's
authority to operate the equipment.
FCC Note
5 Jumpers settings
Please do not change the jumper settings.
6 Technical Specifications
Electrical
Current consumption
(standby)
Battery life
Range (loss)
Voltage requirements
Frequency
Physical
Size
(LxWxD)
Environmental
Operating temperature
Storage temperature
10 uA standby
5 years
300m (1000 feet)
CR123A 3VDC Lithium Batteries
915MHz
81 x 35 x 32 mm
(3.2 x 1.37 x 1.27 in.)
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment on and off, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on to a different circuit from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
© RISCO Group 07/16
0°C to 55°C (-32°F to 131°F)
-20°C to 60°C (-4°F to 140°F)
5IN2583
2

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:6314c482-49b7-11e6-0000-843a313fd000
Producer                        : GPL Ghostscript 9.06
Modify Date                     : 2016:07:11 14:37:46+03:00
Create Date                     : 2016:07:11 14:37:46+03:00
Creator Tool                    : PScript5.dll Version 5.2.2
Document ID                     : uuid:6314c482-49b7-11e6-0000-843a313fd000
Format                          : application/pdf
Title                           : Microsoft Word - 5IN2583 WL Flood Detector
Creator                         : Motti_B
Author                          : Motti_B
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JE4RWT6F915

Navigation menu