Ritetemp 8030C Owner S Manual
8030C 8030C_operation_guide
2014-07-06
: Ritetemp Ritetemp-8030C-Owner-S-Manual ritetemp-8030c-owner-s-manual ritetemp pdf
Open the PDF directly: View PDF .
Page Count: 7
Download | |
Open PDF In Browser | View PDF |
Operation 8030C MENU M PROGRA T RESE Calibration o NOTE: Your thermostat comes from the factory calibrated to + or - 1 F actual temperature. It is an accurate instrument. If you want your thermostat to display the same temperature as another thermometer in your home, you can adjust its calibration. To change the calibration: The unit must be in the HEAT or COOL mode. Press the MENU button. Press the Temp Up/Temp Down arrows to adjust the temperature reading. CALIBRATE DISPLAY ON will appear. Press HOME to save the new setting. MENU PROGRAM CTOR -T FA T RESE Y SPLA DI RATE CALIB Customer Support: 888-515-2585 or Visit our webiste Made in China www.ritetemp-thermostats.com 401-011 Operation 8030C Day Time Slot Time of day Touch Screen Menu button Program button MENU M PROGRA T RESE Current Room Temperature Reset button Target Temperature Fan Switch Mode Switch Thermostat Mode Statement of use: The GPMG8030C can be used with most 24 volt gas, oil or electric heating and air conditioning systems, single-stage heat pumps or gas millivolt heating systems. It cannot be used with 120 volt heating systems or multistage heat pumps. Using a TOUCH SCREEN Please take a moment to try out your touch screen itself. To select a function on the touch screen, place your finger on the main temp display and give a short firm push. Try a "tap" of the finger or stylus. Your input must last long enough for the system to determine it is not an accidental 'bump'. Using the stylus is more comfortable for some users. Again allow the system enough time to recognize your inputs. When you are comfortable with touch inputs, proceed. PG 1 Basic Screens The MODE SWITCH of the 8030C must be in the HEAT or the COOL position to access all control functions. The 8030C Thermostat has 3 basic screens. The HOME screen is displayed when unit is operating your system. Touching the will always return you to this screen. Time Slot Day Current Room Temperature Time of day Touch here to change from 12 to 24hr clock display. Target Temperature Chirp indicator HOME screen Thermostat Mode PG 2 MENU screen Displayed when the MENU button is pressed from the HOME screen. Set C - F Lock Program Set Day Touch this to Touch for 5 sec Touch this area to set set temperature to lock or unlock the day of the week. display. o 1 o 3 Return HOME 2 Set Time Touch this area to set the time of day. Left arrow goes back, right arrow goes forward. Temperature Swing set Filter Timer set -T FACTOR CALIBRATE DISPLAY Calibration indicator This comes on if you Chirp set have altered the Touch this to turn the calibration of your unit audible chirp on or off. Calibration Use this to calibrate your LCD display to match another thermometer. PG 3 PROGRAM screen Displayed when the PROGRAM button is pressed from the HOME Return HOME Set Time Slot Set Program Day When programming Touch this area to set Touch this area to set is complete touch this the Time Slot you the day of the week you to run your program. want to program. want to program Target Temps for. Set Program Time Touch this area to set the time of day you want each time period to start. Left arrow goes back, right arrow goes forward. Copy Touch this area to copy current program to the Review next day touch this area to auto cycle through your program Temp Up / Temp Down arrows. Touch these to raise and lower each Target Temp. PG 4 1 Configure Press MENU to configure the thermostat (from HOME screen). Set day of the week Touch the Day of the week area to cycle through the days of the week to select the current day. Set time of day Touch the Time of Day arrows to move the time selection forward or backward until it displays the Backward Forward current time. Touch and hold for faster setting. Set C - F display Touch the F and it will toggle to o o o o C. Set audible chirp Touch the the musical note icon to select the chirp or no chirp. Return HOME by touching the home icon. PG 5 2 Auto-run This Thermostat comes preprogrammed with an EnergyStar approved program. This program is recommended by the EPA for energy efficiency. TM We strongly recommend that you Auto-Run this program for one week, and see if it works for you. If it does not fit your needs you can always input a custom program. TM To Auto-Run the Energy-Star program, select HEAT or COOL with the mode switch. The unit is now running the Energy-Star program. TM The clock is displayed on the left. The ambient temperature is displayed in the the center of the LCD touch screen. The TIME SLOT icon indicates the TIME SLOT active in the Energy-Star program. Tm The programmed temperature is shown on the lower right. For program details refer to the Energy-Star program chart below. TM MORN 6:00am All Days 70oF HEAT DAY 8:00am 62oF EVEN 6:00pm 70oF NITE 10:00pm 62oF MORN 6:00am All Days 78oF COOL DAY 8:00am EVEN 6:00pm 85oF NITE 10:00pm 78oF PG 6 3 Program NOTE: 60 Second Rule-During programming, if a button is not pushed in 60 seconds, the unit will return to the home screen. Everything you have changed while programming will automatically be saved. Press PROGRAM to go to the programming screen. Select HEAT with the HEAT/Cool MODE switch. Select the day you want to programTouch the Day of the week area to cycle through the days of the week to select the desired day. Select the time slot you want to program Touch the Time slot area to cycle through the 4 time slots, until it displays the desired time slot. Select the time of day Touch the Time of Day arrows to move the time Backward Forward selection forward or backward until it displays the desired time. PG 7 3 Program cont. Select the desired temperature Touch the UP temp / Down temp arrows. Repeat the above procedures for each day of the week and each time slot of the day as desired. To REVIEW your program touch REVIEW. Each time slot for each day or set of identical days, will be displayed every 3 seconds. Return HOME by touching the home icon. To COPY the program from the current day to another day Touch COPY on the program screen. The current day will remain solid, the destination day will flash. Touch the day area to advance the day and select a copy destination. Touch COPY again to copy all settings to the destination day. To program for cooling Select COOL with the Heat/Cool MODE switch and repeat the above procedure. PG 8 Manual The 8030C has 3 manual override commands. These are accessed by touching the Current Temp Display at the HOME screen (center of screen). Target Temperature Return HOME HOLD Touch this area to set a comfortable target temp for the system to hold until you return and remove HOLD. TEMPORARY Manual Override indicator Shows you have temporarily modified the Target Temp. Temp Up / Temp Down arrows Touch these to raise and lower the manual override Target Temp. MANUAL Temporary Override screen PG 9 Manual cont. TEMPORARY Overide At the Manual override screen, Touch the Temp Up / Temp Down arrows to select your desired temporary Target Temperature. Touch HOME to return to operation. The TEMPORARY icon will go on indicating you have modified the Target Temp for the current Time Slot only(see PG7-Time Slot). HOLD At the Manual override screen, Touch HOLD to initiate a hold temperature. Touch the Temp Up / Temp Down arrows to select your hold temperature. Touch HOME to return to operation. The HOLD ON icon will flash indicating you have changed the Target Temp. The system will HOLD this temperature until you return to this screen and de-select HOLD, by touching the HOLD icon again. The Mode Switch must be in HEAT or COOL mode to override. PG 10 4 Special Features Swing Swing setting determines the temperature difference from ON to OFF that the thermostat will command the HVAC system to run. With the MODE switch in HEAT or COOL, press the MENU button. Touch the SWING icon and the current setting of temp swing is shown on the display (default at 3 ). To change the swing, touch the left or right arrows. The furnace will cycle more at the lower numbers as it tries to keep your set point constant. Filter The 8030C has a feature that keeps track of actual furnace run time and reminds you to periodically replace your system's air filter. Press MENU (from HOME screen) and touch FILTER icon. This will display your accumulated filter run time. To input a new filter life time, touch the FILTER icon for 3 seconds. Input the lifetime hours for your new filter. To zero the filter timer for a new filter, touch the accumulated time display. PG 11 To leave the filter display, touch HOME 4 Spec. Featr. cont. Lock Allows you to to prevent any changes in custom settings. To lock, touch the LOCK icon on the MENU screen for 5 sec. To unlock, Touch the locked icon for 5 sec. Low Battery When the batteries are low, the battery icon will come on and flash. The two AA Batteries in the unit need to be replaced. In some installations your heater system will stop functioning when the thermostat loses power. Replace batteries as soon as you see this warning. The thermostat programs will remain for 30 seconds while the batteries are changed. Do not take longer than 30 sec to change the batteries in your unit or you will lose all custom settings and all programming. Only the EnergyStar program will remain. Once the batteries are replaced, the system will return to normal in 2 seconds. TM 12/24 hour The thermostat can display time in 12 or 24 hour formats. At the HOME screen touch the time display to toggle from 12 to 24 hr display. PG 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2004:07:30 21:24:02Z Modify Date : 2004:08:30 21:39:09-07:00 Page Count : 7 Creation Date : 2004:07:30 21:24:02Z Mod Date : 2004:08:30 21:39:09-07:00 Producer : Acrobat PDF File Format dob for Macintosh Author : ob Metadata Date : 2004:08:30 21:39:09-07:00 Creator : obEXIF Metadata provided by EXIF.tools