Riverbed Technology DTAFA Wireless a/b/g/n/AC Access Point User Manual rev

Riverbed Technology Inc. Wireless a/b/g/n/AC Access Point Users Manual rev

Users Manual_rev.pdf

Download: Riverbed Technology DTAFA Wireless a/b/g/n/AC Access Point User Manual rev
Mirror Download [FCC.gov]Riverbed Technology DTAFA Wireless a/b/g/n/AC Access Point User Manual rev
Document ID2985163
Application IDMQ99fnevzYRcf8kkViQ9eA==
Document DescriptionUsers Manual_rev.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.02kB (350261 bits)
Date Submitted2016-05-10 00:00:00
Date Available2016-05-10 00:00:00
Creation Date2016-05-06 13:25:52
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2016-05-06 13:25:52
Document TitleUsers Manual_rev.pdf
Document CreatorMicrosoft® Word 2010
Document Author: Julie.Wang(王嘉玲)

STEELCONNECT
TM
ACCESS POINT
LET'S GET STARTED…
1. POSITION THE DEVICE
You can mount the Access Point (AP) to a wall or ceiling using the attached snap disk.
If you do not require a solid mount, you can use the AP as a desktop unit.
For best radio coverage, ceiling mount the AP.
The AP ships with the rack mount hardware.
2. CONNECT THE POWER
Supply the AP with power using either the power supply (12 VDC, 2.0 A) or a
PoE injector (48 VDC, 0.5 A).
3. CONNECT TO THE NETWORK
Connect the AP to your local network. To find a SteelConnect Manager instance,
the AP needs Internet access; make sure the network provides a DHCP service
so the AP can establish a connection automatically.
4. Pre-Install Preparation
You should complete the following steps before going on-site to perform an installation.
4.1 Configure Your Network in SteelConnect Manager
Riverbed recommends that you add your AP to a network in Dashboard before
mounting it in the field. The following is a brief overview only of the steps required to add
an AP to your network. For detailed instructions about creating, configuring and managing
Riverbed wireless networks.
1. Login to http://dodo.oceddo.cc. If this is your first time, create a new account.
2. Find the network to which you plan to add your nodes or create a new network.
3. Add your nodes to your network. You will need the serial number of each node, which
looks like xxx-xxxx-xxxx, and is found on the bottom of the unit.
4.2 Assigning IP Addresses to AP
All gateway AP (AP with Ethernet connections to the LAN) must be assigned routable IP
addresses.
These IP addresses can be dynamically assigned via DHCP or statically assigned.
4.2.1 Dynamic Assignment
When using DHCP, the DHCP server should be configured to assign a static IP address
for each MAC address
belonging to a Riverbed AP. Other features of the wireless network, such as 802.1X
authentication, may rely on the property that the APs have static IP addresses.
4.2.2 Static Assignment
Static IPs are assigned using the local web server on each AP. The following procedure
describes how to set the static IP:
1. Using a client machine (e.g., a laptop), connect to the AP either wirelessly (by
associating to any SSID broadcast by the AP) or over a wired connection.
If using a wired connection, connect the client machine to the AP either through a PoE
switch.
2. Using a web browser on the client machine, access the AP’s built-in web server by
browsing to http://dodo.oceddo.cc
3. Click on the “Static IP Configuration” tab.Configure the static IP address, net mask,
gateway IP address and DNS servers that this AP will use on its wired connection.
5. If necessary, reconnect the AP to the LAN.
Need help?
Riverbed Technology | 680 Folsom Street | San Francisco, CA 94107
support@riverbed.com | (415) 247-7381 | www.riverbed.com
WEEE-Reg.-Nr. DE 36272080
LED LIGHTS
Green: Power | Orange: Ethernet
LEDs turn off when the AP enters normal operation mode.
FACTORY RESET
To reset the AP to its factory state, press the reset button on the back panel for
10 seconds. After releasing the button, all five LEDs flash and the AP resets to the
factory default state.
TEMPERATURE RANGES
Operating temperature: 0°C - 40°C | 32°F - 104°F
Storage temperature: -20°C - 60°C | -4°F - 140°F
For more information, go to https://support.riverbed.com.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
For operation within 5.15 ~ 5.25GHz frequency range, it is restricted to indoor
environment.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
30cm between the radiator & your body.
Industry Canada statement:
This device complies with ISED’s licence-exempt RSSs. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le
dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter
tout brouillage reçu, y compris un brouillage susceptible de provoquer un
fonctionnement indésirable.
Caution :
(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce
the potential for harmful interference to co-channel mobile satellite systems;
(ii) the maximum antenna gain permitted for devices in the band 5725-5850 MHz shall
be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point
and non-point-to-point operation as appropriate; and
(iii) Users should also be advised that high-power radars are allocated as primary users
(i.e. priority users) of the bands 5650-5850 MHz and that these radars could cause
interference and/or damage to LE-LAN devices.
Avertissement:
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement
pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux
systèmes de satellites mobiles utilisant les mêmes canaux;
(ii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5725 à 5
850 MHz) doit être conforme à la limite de la p.i.r.e. spécifiée pour l'exploitation point à
point et l’exploitation non point à point, selon le cas;
(iii) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de
haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour
les bandes 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des
dommages aux dispositifs LAN-EL.
Radiation Exposure Statement:
This equipment complies with ISED radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 33cm between the radiator & your body.
Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies
pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un
minimum de 33 cm de distance entre la source de rayonnement et votre corps.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 5
Language                        : zh-TW
Tagged PDF                      : Yes
Author                          : Julie.Wang(王嘉玲)
Creator                         : Microsoft® Word 2010
Create Date                     : 2016:05:06 13:25:52+08:00
Modify Date                     : 2016:05:06 13:25:52+08:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZHV-DTAFA

Navigation menu