Rixson 2700L (10 09) Heavy Duty Floor Closers Installation Instructions
User Manual: Rixson 2700L Heavy Duty Floor Closers Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
PAGE 4 Closer Adjustment BA CLOS DELAY Template F - 13/16 3/4 TU F HO ON OF RN FULL 1 Do not use Backcheck as deadstop. This is an intensity valve not speed control. Arm 5-7/8 Cement Case 1-3/4 Jamb 3/4 DELA YED ped uip eq If B. The Closing Speed valve allows adjustment from full open to 15° on units without the Delay Action feature. 1” 1-5/8 5/8 R. 7/16 3/4 3/4 C L 3/8 3/4 70° 3/4 1-3/4 D 1-1/2 3/16 1” 3/4 13/16 1/16 1/2 Thrust Bearing Spindle Shoulder Collar B 5/16 3/8 R. 2-1/4 3/8 Door Mortised "A" Deep for Arm "A" 1/4 Threshold 1-3/16 1/2 Threshold 15/16 Floor Plate CLOSED Cement Case Threshold 4-1/16 Floor Closer Case E. Important: Backcheck adjustment must be adjusted to vary resistance from light to firm at 60° of door open. Support Adjuster Closer Type This closer is one of three types as follows: 1. Non hold-open factory set. No hold-open adjustments. 2. Automatic hold-open factory set. No hold-open adjustment. 7-3/4 7-1/4 6-1/2 5-1/4 4-1/2 3-1/4 2-1/2 1/2 3. Selective (on-off) hold-open label will indicate position of on-off selector screw. When turned “on”, closer has automatic holdopen: turned “off”, hold-open will not function. Turn full 180°. Door Size 1-3/4 2” 2-1/4 2-1/2 3” These adjustments if required should be done by an authorized repair agency. Repairs, parts replacement or internal adjustments must be done by a Rixson authorized repair agency. Consult www.rixson.com for an authorized repair agency in your area. RIXSON Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2006, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. www.rixson.com ASSA ABLOY 866-474-9766 Technical Department A 30° 3/4 Arm Cap A B Max. Lead Thk. 1-1/4 1/4 9/32–7.14mm 1-3/8 5/16 3/8–9.52mm 1-1/2 3/8 15/32–11.90mm 1-5/8 7/16 9/16–14.28mm 2” 1/2 3/4–19.05mm Table based on lead placed in center or door. ® 5/16 B 1-1/4 This closer can be adjusted for increased or decreased spring power. WITH THRESHOLD Set Cement Case Flush with Finished Floor 1-1/4 Spring Power Adjustments Rixson Specialty Door Controls A 1-1/16 15° D. Latch valve allows adjustment from 15° to closed position. 5/16 60° 9-13/16 Cement Case 9-7/8 Floor Plate AC TI ON Top Pivot 6-1/8 Floor Plate Floor Plate 2-1/16 R. A. The Delay Action valve allows adjustment from full open to 65° closed position. (Optional) 2-15/16 2-5/16 1-11/16 1-1/16 7/16 Jamb 1/8 Min. Clearance Required Between Door and Stop 3/16 R. Bevel Edge of Door 1/8” in 2” This Set Screw Is On Selector Hold-open Types Only C. The Closing Speed valve allows adjustment from 65° to 15° closed position on closers with Delay Action feature. 4-1/4 3-9/16 C C K HE + ° 80 TU RH 2700L (10-09) S LO W S LO W Closing speeds can be adjusted to suit local conditions and requirements. Label on closer face designates the purpose of each adjustment screw. Adjustments are for speed control. Installation Instructions CK FULL 1 G S PE ATCH 3/4” Offset Pivoted – Handed L180 Top Pivot – Non Handed ED HO O F S LO W IN ACTI L27 & L27-180 Heavy Duty Floor Closers ASSA ABLOY FRANKLIN PARK ILLINOIS ° 80 RN - IN G S PE ED ON C C K HE CK BA S LO W CLOS DELAY L ACTI ON ATCH ON LH + RIXSON FIREMARK FRANKLIN PARK ILLINOIS L RIXSON FIREMARK RIXSON ® Right Hand Shown Conversion from inches to metric: inch x 25.4 Rixson Specialty Door Controls 5/16 3/4 1-1/16 Note: 1. Arm and pivot leaf drilled to receive 2” #14 FHWS or 1” x 1/4-20 FHMS. 2. For Wood Doors: Pre-drill arm and 3/16 top pivot holes to prevent splitting. 3. If vertical adjustment is required two Floor 1/16” shims are provided. Place Plate shims between arm and spindle Cement Case shoulder collar. 4. Max degree of opening, trim permitting, is 105°. Suitable WITH FLOOR PLATE reinforcing by others. Leadlining by Set Cement Case 1/8" Below others. Surface of Finished Floor www.rixson.com Door Mortised 1-5/16 Deep for Arm 866-474-9766 Technical Department PAGE 2 PAGE 3 Top Pivot Jamb Portion LH 4. Hang Door Floor Closer Case How To Determine Hand of Door Top Pivot Door Portion RH X Heavy Duty Cement Case Spindle Arm Knuckle CAUTION: 4a Arm Cap Arm Locking Screw X Pins point down for RH closer A. Close down Latch Speed valve. Using wrench, turn spindle until wrench is parallel with center line of closer. (Illustration 4a)Install thrust bearing and spindle shoulder collar. X Wrench Adjustable Screw Pad B. Set door on closer spindle. DO NOT FORCE DOOR CLOSED WHILE “CLOSING SPEED” VALVE IS TURNED DOWN. CAUTION: Face a door swinging open away from you. If it opens to the right, it is right hand. If it opens to the left, it is left hand. RIGHT HAND installation IMPORTANT: Use plumb line to make sure that center line of top pivot pin lines up with center line of closer spindle. An adjustable screw pad is provided in this heavy duty cement case for better load distribution. This pad is adjusted so the heavy duty closer case is equally supported by the adjustable pad and the case flange pads at outer corners of case as shown by “X”. Pad is staked to keep from coming loose. Right Hand Shown C. Push item 1 “top pivot pin” into place. Attach “cap” item 2. (Illustration 4b) CAP MUST BE TIGHTENED SECURELY. D. Close door to 60° or more and turn Closing Speed valve screw counterclockwise. Door will then close. 4b 1 Installation Instructions E. Open Closing Speed valve (counterclockwise) one turn. To increase (speed up) closing, open Latch Speed valve (ccw) one turn. 1 2 2 F. 1. Locating Closer 2. Install Cement Case in Floor For accurate installation see your dealer for a 185 Quickspotter Kit. 4c 1/8” Minimum From Face of Door to Door Stop Door Jamb If door drags at floor (or threshold, if used), remove door, insert a spacer (Illustration 4c) and rehang door. G. While working door back and forth TIGHTEN ARM LOCKING SCREW SECURELY with wrench furnished. LEVEL IN BOTH DIRECTIONS Door Stop Closer is shipped with Closing Speed valve down. DO NOT FORCE VALVE DOWN. H. Put arm cap on closer spindle and secure TIGHTLY with cap screw furnished. Arm Cap I. Adjust closing and latch speeds as required for proper closing. Arm A. For floor plate application: Cement case is set 1/8” (3.2mm) below floor level. B. For threshold application: Cement case is set flush with floor. C. Set cement case in floor and block in position. D. Case should be parallel with center line of door. E. CEMENT CASE SHOULD BE LEVEL. Place levels per Illustration. F. Grout in cement case with closer. Cement should not get between closer and case. Right Hand Door 3/4” From Face of Door to CL of Spindle Spindle Position 13/16” From Face of Jamb to CL of Spindle A. Measure 13/16” out from door jamb. B. Allow 1/8” minimum clearance from door stop to door face. Measure door thickness. Add 3/4”. C. Where lines meet determines center line of closer. Rixson Specialty Door Controls Spacer Thrust Bearing 3. Install Top Pivot & Closer Arm A. Install top pivot in door per template. B. Install top pivot in frame per template. C. Center line of pivot should line up with center line of closer. Use plumb line as illustrated. D. If side pivot is used, see template for intermediate pivot. E. Install door closer arm in bottom of door per template. www.rixson.com 866-474-9766 Technical Department Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : AdobePS5.dll Version 5.0.1 Modify Date : 2009:10:08 14:08:45-04:00 Create Date : 2009:10:08 14:08:29-04:00 Metadata Date : 2009:10:08 14:08:45-04:00 Format : application/pdf Title : 2700L (10-09).cdr Document ID : uuid:41f7b6d0-6047-480f-9392-76c92048bdca Instance ID : uuid:b35cfc56-58b5-4f3a-8908-3895cc17059c Page Count : 2 Creator : AdobePS5.dll Version 5.0.1EXIF Metadata provided by EXIF.tools