Rixson IS H340 Top Pivot Center Hung Non Handed

User Manual: Rixson H340 Top Pivot Center Hung Non Handed Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 1

H340 Top Pivot
Center Hung
Non Handed
IS-H340
Notes:
1. Do not scale drawing.
2. Dimensions are given in inches (mm).
Installation Instructions:
1. Prepare door and frame per details shown.
2. To insure proper operation of door, the centerline of the top pivot pin
must be straight and plumb with bottom spindle.
3. Install jamb portion with pin retracted.
4. Install door portion.
5. Place door on bottom pivot and raise door to vertical position.
6. Engage top pivot pin by turning adjusting screw clockwise when door
portion is in alignment with the jamb portion.
1-15/32
(37.3)
6-3/4
(171.4)
1-7/16
(36.5)
9/32
(7) 1/4
(6.4)
1-13/16
(46)
21/32
(16.7)
15/32
(11.9)
Top Pivot Jamb Portion
9/32
(7.2)
1-5/16
(33)
9/32
(7.2)
9/32
(7.2)
#12-24 x 5/8 FHMS or
#12 x 1-1/4 FHWS (2 Places)
1/4-20 x 5/8 FHMS or
#14 x 1-1/2 FHWS
1-1/8
(28.6)
1/16
(1.6)
7/8
(22.2)
9/16
(14.3)
1”
(25.4) Dia.
Dia.
1-5/16
(33.3)
Finish Plate
Top Pivot Door Portion
H340 Top Pivot
Pivot Shown Engaged
2”
(50.8)
15/32
(11.9) 4-13/16
(122.2)
7-9/32
(185)
1-1/4
(32)
5/8
(15.9)
1/4-20 x 5/8 FHMS or
#14 x 1-1/2 FHWS (3 Places)
www.rixson.com
ASSA ABLOY
RIXSON®
DATE
TEMPLATE NUMBER
07-09
Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2003, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.