Robertshaw Low Capacity Gas Valves And Accessories 7000Lc Users Manual VA Air Beta Program National Rollout
2015-01-21
: Robertshaw Robertshaw-Low-Capacity-Gas-Valves-And-Accessories-7000Lc-Users-Manual-351677 robertshaw-low-capacity-gas-valves-and-accessories-7000lc-users-manual-351677 robertshaw pdf
Open the PDF directly: View PDF
.
Page Count: 24
| Download | |
| Open PDF In Browser | View PDF |
Low Capacity Gas Valves & Accessories UNI-LINE® PRODUCT KNOWLEDGE © Copyright Invensys Controls 2009 Subjects We Will Cover In This Session Fuel Characteristics Gas Valve Applications Robertshaw® 7000LC (Low Capacity) Series Hydraulic Actuated 24 Volt Actuated Millivolt Actuated 7500 Series - Coming Soon! Manufacturers Pilot, Thermocouple, and Thermopile Basics Website Tools When You Have Questions Q&A Acronyms BTU = British Thermal Units LC = Low Capacity LP = Liquid Propane MV = Main Valve NAT = Natural Gas PD = Pressure Drop PV = Pilot Valve SLC = Snap-action Low Capacity V = Volts WC” = Water Column inches Fuel Characteristics Natural Gas Characteristics Liquid Propane (LP) 0.64 Specific Gravity 1.53 1000 BTUs / Cubic Feet 2500 7”WC – 10.5”WC Service Pressure Range 11”WC – 14”WC 1200º F Ignition Temperature 950º F 10/1 Combustion 24/1 Air/Gas Ratio Natural gas is lighter than air and rises L.P. gas is heavier and puddles in the lowest area it can find Fuel Characteristics of British Thermal Units Definition of a BTU – The quantity of heat required to raise the temperature of one pound of water one degree Fahrenheit Many gas appliances are rated depending on BTU output – The more heat needed, the higher the BTU rating Residential gas water heaters (regardless of fuel) are rated between 15,000 and 75,000 BTU Over 75,000 BTU is considered Commercial Water Heater Commercial Water Heaters are rated between 75,000 and 750,000 BTU Space Heating and Hearth Applications Factory Model Uni-Line® Part Number BTU @ 1” PD Natural Gas Catalog Page Liquid Propane 7000 STD Nat 300,000 Min - Max BTU Capacity Pages 68-82 LP 485,000 10,000 – 900,000 7200 Nat 150,000 15,000 – 200,000 Uni-Line 720 Pages 85-87 LP 240,000 15,000 – 320,000 2000 DER/IPER Nat 125,000 25,000 – 170,000 Uni-Line 722 Page 88 LP 200,000 25,000 – 272,000 7500 Nat 100,000 6,700 – 160,000 Coming Soon! LP 162,000 12,000 – 226,000 Nat 40,000 5,000 – 70,000 Uni-Line 710 Pages 83-84 LP 65,000 5,000 – 100,000 7000 ST Nat 100,000 10,000 – 160,000 Uni-Line 700 Pages 70-71 LP 162,000 Intermittent Pilot Direct Spark Y Y Y Y Y Y N Y (IPER) Y (DER) Y N N Y N N Y N N 10,000 – 720,000 Uni-Line 700 7000 LC & SLC Standing Pilot 10,000 – 226,000 7000LC (Low Capacity) Factory Series Most popular Low Capacity Uni-Line® part is 710-502 Designed for: – Standing Pilot only – OEM replacements Incorporates the following: – Manual Valve – Pilot Valve – Main Gas Pressure Regulator Applications include: – – – – Patio Heaters Recreation Vehicles Wall Furnaces Fireplace Hearth 710-100 Series 710-200 Series 710-400 Series 710-500 Series Manual Hydraulic 24 Volts Millivolt 7000LC (Low Capacity) Example Factory Number is 7000MVRLC Contains MV for Millivolt Actuator Contains R for Regulated Contains LC for Low Capacity Uni-Line® Part 710-502 BTU rating range is 5,600 - 70,000 Regulator is 3.5” WC for Natural Gas Inlet and outlet size are 1/2” x 1/2” Pilot outlet is 1/4” 7000LC Hydraulic Actuated Gas Valve Most popular Hydraulic Snap-Action part is 710-205 Add “S” to Factory Part for Snap-Action ie. 7000SRLC 56F LO 1 2 3 4 5 6 7 8 HI 90F ECO (Limit) Gas Cock Temperature Control Knob Sensing Bulb Safety Pilot and Thermocouple 7000LC 24 Volt Actuated Gas Valve Most popular Uni-Line® part is 710-402, Factory Part 7000-ERLC Wall Thermostat 24 VAC 120 VAC Transformer ECO (Limit) High Limit NC Fan Control NO Gas Cock Operator Fan Motor Pilot and Thermocouple 7000LC Millivolt Actuated Gas Valve Wall Thermostat ECO (Limit) Gas Cock Safety Pilot Line ⇒ Operator Pilot and Thermopile 7000LC Millivolt Actuated - Wiring Most popular part is 710-502 Factory model is 7000MVRLC Safety Magnet OPERATOR TH/TP R W TP TH 1950 Series Two-Lead Thermopile 7500 Series Gas Valve – Coming Soon! Designed for: – OEM replacements – Smaller Locations Incorporates the following: – Manual Valve – Pilot Valve – Main Gas Pressure Regulator – Field Convertible without additional components Applications include: – Central Heating Units – Wall Heaters – Hearth Fireplaces Gas Valve Manufacturers Markets Robertshaw® Honeywell White- Rodgers Dexen SIT USA based Engineering and Technical Services USA based Engineering and Technical Services USA based Engineering and Technical Services Taiwan based Italian based Engineering and Technical Services No Engineering nor Technical Services Space & Central Heating Yes Yes Yes Yes Yes Residential Water Heating Yes Yes Yes No Yes Hearth Products Yes Yes No Yes Yes Pilots, Thermocouples, Ignition systems Yes Yes Yes No Yes Robertshaw® Gas Valve Accessories Pilots Thermocouples Thermopiles Pilot Basics Pilot Parts Order 1820 Series with Left of Right flame pattern type Pilot Uni-Kits® are with or without Thermopile pre-mounted Thermocouple Basics “Hot” Junction Copper-Nickel Alloy Copper-Iron Alloy “Cold” Junction Insulated Copper Wire Copper Sheath Contact Button UUUUUUU Load (Safety Magnet) Fitting Nut Contact Button Thermocouple Parts The 1980 series offers easy installation into most pilot burners Uses Snap-Fit® technology End of part number refers to various lengths: – 1980-012 is 12 inches – 1980-072 is 72 inches Thermopile Basics Hot Junctions Cold Junctions UUUUUU Load (Safety Magnet) UUUUUU Load (Gas Valve) 1950 Series Twin Lead Connector Thermopile Parts The 1950 series thermopiles have two lead wire connections and are primarily used in HVAC applications Note: The 1951 coaxial series used mostly on Commercial Cooking applications Twin lead wires Quiz Question #1 What is the difference between thermocouples and thermopiles? A. B. C. D. Voltage Size Application All of the Above Find Answers On www.Uni-Line.com Website Enter part numbers Click here for more information When You Have Questions Technical Service 1-800-445-8299 Fax 1-630-260-7294 Customer Service 1-800-304-6563 Fax 1-800-426-0804 Uni-Line® Catalog Website: www.Uni-Line.com Cross Reference Website: www.uni-line.com/templates/xrefsearch.aspx General Information Websites: Robertshaw®, Paragon®, Eliwell™, Ranco®, and Publication Zone® www.InvensysControls.com www.RobertshawTstats.com www.ToolBox.InvensysControls.com/templates/Login.aspx Invensys®, Robertshaw® Paragon®, Ranco®, Eliwell™, Uni-Line, and Make the Connection™ are trademarks of Invensys plc., its subsidiaries and/or affiliated companies. All other brands mentioned in this document may be the trademarks of their respective owners. © 2009 Invensys Controls. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : Acrobat PDFMaker 8.1 for PowerPoint Modify Date : 2009:10:02 10:55:59-05:00 Create Date : 2009:10:02 10:54:56-05:00 Metadata Date : 2009:10:02 10:55:59-05:00 Format : application/pdf Creator : Title : VA Air Beta Test Program and National Rollout Document ID : uuid:3c2969b3-06b2-454f-857b-c7c5ff8f0aa5 Instance ID : uuid:ab37fdf7-4790-448c-ac19-bf023262a775 Company : Jmc Marketing Page Count : 24 Page Layout : SinglePage Author :EXIF Metadata provided by EXIF.tools