Operating Manual for
Model 34288
Recovery, Recycling, Recharging Unit
O
p
e
r
a
t
i
n
g
M
a
n
u
a
l
SAFETY DEFINITIONS: Follow all WARNING, CAUTION, and NOTE messages in this manual. These messages are dened as
follows: WARNING means you may risk serious personal injury or death; CAUTION means you may risk personal injury, property
damage, or unit damage; and NOTEs and OPERATING TIPS provide clarity and helpful information. These safety messages cover
situations ROBINAIR is aware of. ROBINAIR cannot know, evaluate, and advise you as to all possible hazards. You must verify that
conditions and procedures do not jeopardize your personal safety.
DISCLAIMER: Information, illustrations, and specications contained in this manual are based on the latest information available
at the time of publication. The right is reserved to make changes at any time without obligation to notify any person or organization
of such revisions or changes. Further, ROBINAIR shall not be liable for errors contained herein or for incidental or consequential
damages (including lost prots) in connection with the furnishing, performance, or use of this material. If necessary, obtain additional
health and safety information from the appropriate government agencies and the vehicle, refrigerant, and lubricant manufacturers.
ALLOW ONLY QUALIFIED PERSONNEL TO OPERATE THE UNIT. Before operating the unit, read and follow
the instructions and warnings in this manual. The operator must be familiar with air conditioning and refrigeration
systems, refrigerants, and the dangers of pressurized components. If the operator cannot read this manual,
operating instructions and safety precautions must be read and discussed in the operator’s native language.
PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. Do not overll the internal storage vessel, because
overlling may cause explosion and personal injury or death. Do not recover refrigerants into nonrellable
containers; use only federally authorized rellable containers (DOT spec. 4BW or 4BA).
HOSES MAY CONTAIN LIQUID REFRIGERANT UNDER PRESSURE. Contact with refrigerant may cause per-
sonal injury. Wear protective equipment, including safety goggles. Disconnect hoses using extreme caution.
AVOID BREATHING A/C REFRIGERANT AND LUBRICANT VAPOR OR MIST. Exposure may irritate eyes,
nose, and throat. To remove refrigerant from the A/C system, use only equipment certied for the type of
refrigerant being removed. Use the unit in locations with mechanical ventilation that provides at least four air
changes per hour. If accidental system discharge occurs, ventilate the work area before resuming service.
DO NOT USE AN EXTENSION CORD. An extension cord may overheat and cause re. If you must use an
extension cord, use the shortest possible cord with a minimum size of 14 AWG.
TO REDUCE THE RISK OF FIRE, do not use the unit in the vicinity of spilled or open containers of gasoline
or other ammable substances.
CAUTION—DO NOT PRESSURE TEST OR LEAK TEST EQUIPMENT AND / OR VEHICLE AIR CONDI-
TIONING SYSTEMS WITH COMPRESSED AIR. Some mixtures of air and refrigerant have been shown to be
combustible at elevated pressures. These mixtures, if ignited, may cause injury or property damage.
TO PREVENT CROSS-CONTAMINATION, USE THIS UNIT WITH R-134a REFRIGERANT ONLY. The unit is
designed to recover, recycle, and recharge only R-134a refrigerant. Do not attempt to adapt the unit for another
refrigerant. Do not mix refrigerant types through a system or in the same container; mixing of refrigerants will
cause severe damage to the unit and the vehicle air conditioning system.
HIGH VOLTAGE ELECTRICITY INSIDE THE UNIT HAS A RISK OF ELECTRICAL SHOCK. Exposure may
cause personal injury. Disconnect the power before servicing the unit.
Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.
WARNINGS
Model 34288
Recovery, Recycling, & Recharging Unit
OPERATING NOTE: At temperatures exceeding 120° F / 49° C, wait 10 minutes between recovery jobs.
1
543175 Rev. H, June 25, 2013
Table of Contents
Introduction2
 TechnicalSpecications2
 KeypadFunctions3
 Glossary3
 MenuFunctions4
Setup 5
 UnpacktheAccessoryKit5
 PowerUptheUnit5
 SelectaLanguage5
 SelectOperatingUnits5
 SetTankFillLevel6
 AddOiltotheVacuumPump6
 FilltheInternalStorageVessel7
OperatingInstructions8
RecoverRefrigerantfromaVehicle                             8
 EvacuatetheA/CSystem9
 RechargetheA/CSystem10
Maintenance12
 General12
 ElectricalProtection12
ManuallyFilltheInternalStorageVessel(ISV)                    12
 ReplacetheFilter-Drier13
CheckRemainingFilterCapacity                            13
 ChangetheFilter13
 AdjustTankFillLevel14
 CheckforLeaks14
 ChangeVacuumPumpOil15
 ReplacementParts16
 ScaleCalibration16
 TankRecertication16
SpanishManual17
FrenchManual35
SafetyPrecautions                                InsideFrontCover
WarrantyInsideBackCover
IMPORTANT: To comply with federal law governing A/C system service, you must complete and mail
the MVAC Certication Form included in the accessory kit. Technicians using this equipment must be
certied under EPA Section 609 (Environmental Protection Agency). For more information, read the
MACS information included in the accessory kit, or visit the MACS website at www.macsw.org.
To validate the warranty provided by Robinair, complete the warranty card included in the accessory
kit, and mail it within ten days from the purchase date of the unit.
2
Introduction
RobinairNo34288isusedonR-134avehiclesandisdesignedtobecompatiblewithexistingservice
equipmentandstandardserviceproceduresModelNo34288isaUL-listed,single-passsystem
thatmeetsSAEspecicationsforrecycledrefrigerantFollowtheSAE-J2211recommendedservice
procedureforthecontainmentofR-134a
Theunitincludesa15cfm(42l/m)Robinairhighvacuumpumpforfast,thoroughevacuationThe
compressorpullstheA/Csystemto0psig,thenworksinserieswiththevacuumpumptoachievehighly
efcientrecoveryandimmediaterechargeIfthesystemisnotopenedforservice,thereisnoneedtopull
additionalvacuumIfthesystemisopenedforservice,usetheunit’svacuumcycletoremoveairand
moisturefromtheA/Csystem(Werecommendaminimum15-minutevacuum,orfollowthevehicle
manufacturersspecs)Note: R-134a systems require special oils. Refer to the A/C system manufacturers
service manual for oil specications.
Technical Specications
Voltage115V,60Hz
Operating Range     50°to120°F(11°to49°C)
Filter-Drier                43cuinspin-ontype
Pump Free-Air Displacement
   15cfm(42l/m)
Dimensions49"Hx34"Wx23"D
               (1245cmx864cmx584cm)
Digital Display: visual
interface between operator
and machine.
Main Power Switch: supplies
electrical power to unit.
Manifold Gauges:
connect to vehicle A/C system;
show system’s low-side and
high-side pressure.
Tool Storage Area
(additional storage
on back side for
extra lter-driers and
oil bottles).
Panel Valves:
direct system’s low-side
and high-side pressure.
Power Cord
3
543175 Rev. H, June 25, 2013
Introduction
Keypad Functions
START /
YES
START / YESbeginsorresumesa
function,oranswersaquery
STOP / NO terminatesorpausesa
function,oranswersaquery
MENU displaystheselectionmenu
ARROWSareusedforscrolling
throughmenuitems
RECOVER activatestherecovery
sequence
VACUUM activatesthevacuum
sequence
CHARGE chargesthevehicleA/C
systemwithaprogrammedamount
ofrefrigerant
RECOVER
STOP /
NO
VACUUM
CHARGE
MENU
Glossary
A/C System :Thevehicleairconditioningsystembeingserviced
Internal Storage Vessel :Therellablerefrigerantstoragevessel
designedspecicallyforthisunit;30lb(14kg)
Source Tank :Adisposabletankofnewrefrigerantusedtorell
theinternalstoragevessel;notincluded
Unit :ModelNo34288
Keypad
START /
YES STOP /
NO
RECOVER
VACUUM
CHARGE
MENU
4
Menu Functions
1 PresstheMENUbuttononthekeypad
2 PresstheUPorDOWNarrowkeytoscroll
throughthemenuchoicesshownonthesecond
lineofthedisplay:
 SELECTLANGUAGE
 VERSIONXXX
 SELECTUNITS
 MAINTAINVACUUMOIL
 MAINTAINFILTER
 REFRIGMANAGEMENT
 MANUALREFILL
 ADJUSTTANKFILLLVL
 CALIBRATIONCHECK
 SERVICEMENU
 DISPLAYTANKINFO
3 PressSTART / YEStomakeachoicefromthe
menuPressSTOP / NOtopauseduringany
process,andSTOP / NOasecondtimetoexit
aprocess
Introduction
Select Language
Operatormaychoosetohavepromptsdisplayedinoneofthree
languages:English,Spanish,orFrench
Version X.XX
Displaystherevisionlevelofthesoftwareintheunit
Select Units
The operator may choose to have test results displayed in
Imperial(lb),Imperial(lbandoz),orMetric(kg)
Maintain Vacuum Oil
For maximum vacuum pump performance, change vacuum
pumpoilafterevery10hoursofoperationThismenuitem
displayshowlongthevacuumpumphasoperatedsincethe
lastoilchange,andallowstheusertoresetthevalueoncean
oilchangeiscompleteRefertotheinstructionsoutlinedinthe
MaintenancesectionunderChange Vacuum Pump Oil
Maintain Filter
The lter-drier removes acid, particulates, and moisture
from the refrigerant To meet SAE J-2788 requirements,
it is mandatory to replace the lter-drier after 150 lbs
(68kg)ofrefrigeranthasbeenlteredThismenuitemshows
howmuchrefrigeranthasbeenlteredsincethelastlterchange,
andallowstheusertoresetthevalueoncealterchangeis
completeAcode,whichappearsonthelter,mustbeentered
into the unit to ensure compliance with SAE J-2788 Refer
totheinstructionsoutlinedintheMaintenancesectionunder
Replace the Filter-Drier
Refrig Management
Displays the amount of refrigerant recovered, charged, and
replenished(forthelifeoftheunit),andltered(sincethelast
lterchange)
Manual Rell
Usetotransferrefrigerantfromthesourcetanktotheinternal
storage vessel (ISV) Refer to instructions outlined in the
MaintenancesectionunderManually Fill the ISV
Adjust Tank Fill Lvl
Duringthetankrellprocess,theunitstopsrellingwhenit
reachesthepre-setamountofrefrigerantintheinternalstorage
vessel(defaultis15lbs)Thisvaluemaybeadjustedupor
downtosuittheusersneedsRefertoinstructionsoutlinedin
theMaintenancesectionunderAdjust Tank Fill Level
Calibration Check
UsetoverifyinternalscalecalibrationRefertoinstructionsin
MaintenancesectionunderScale Calibration Check
Service Menu
ForRobinairservicecenteruseonly
Display Tank Info
Displaysinternalstoragevessel(ISV)pressureandtemperature
UsetochecktheISVforexcessivepressure
Arrow
Keys
Start / Yes
Button Stop / No
Button
Menu
Button
START /
YES STOP /
NO
RECOVER
VACUUM
CHARGE
MENU
5
543175 Rev. H, June 25, 2013
Setup
Unpack the Accessory Kit
Unpacktheaccessorykitfromthebag,andremovethe
plasticpackagingThekitconsistsof
• Low-sidetankadapter
• Calibrationweight
• Vacuumpumpoil,oilllercap,andtube
• Plasticpouchcontainingawarrantycard(tobe
completedandmailed),applicableMSDSsheets,a
servicecenterlisting,andanenvelopeofMobileAir
ConditioningSociety(MACS)information
Important: You must complete and mail the
MVAC Certication Form, and your technicians
must be certied with the Environmental
Protection Agency (EPA) to operate this
equipment.
Power Up the Unit
1 Unwindthepowercordfromthehandle,andplugit
intoacorrectvoltageoutletSeeFigure1
2 TurnonthemainpowerswitchThersttimethe
unitispoweredup,itdisplaystheinitialsetupmode
Select a Language – English
Seleccionar Idioma – Espanol
Selection Langue – Francais
Theoperatormaychoosetohavepromptsdisplayedin
oneofthreelanguages:English,Spanish,orFrench
1
UsetheUPorDOWNarrowkeytotogglethrough
thechoicesforEnglish,Spanish,orFrench
2
PressSTART / YEStoselectthedisplayedlanguage
Select Operating Units
Theoperatormaychoosetohavetestresultsdisplayed
inImperial(lb,orlbandoz)orMetric(kg)units
1 UsetheUPorDOWNarrowkeytotogglethrough
choicesforIMPERIALUNITSorMETRICUNITS
2 PressSTART / YEStoselectthedisplayed
operatingunitchoice
IMPORTANT :
R-134a systems have
special ttings (per SAE specications)
to avoid cross-contamination with R-12
systems. DO NOT adapt your unit for a
different refrigerant — system failure
will result.
Power
Cord
Main
Power Switch
Figure 1
6
Set Tank Fill Level
Theoperatormayeitheraccepttheunit’spre-setdefault
weightof15lbs(68kg)ofrefrigerantstoredinthe
internalstoragevessel(ISV),orchangetheamountto
accommodatetheapplication
Theunitdisplays
LEVEL:1500LBS
ENTERTANKFILLLVL
LIMIT:4TO17LBS
PRESSSTART/YESTOSAVE
1 PressSTART / YEStoacceptthedefaultamount,
orusethearrowkeystoenteradesiredamountand
pressSTART / YES.
Add Oil to the Vacuum Pump
IMPORTANT: The vacuum pump is shipped
without oil in the reservoir. Failure to add oil to
the vacuum pump will damage the pump.
Theunitdisplays
ADD5OZOFNEWOIL
TOVACUUMPUMP
STARTTOCONTINUE
1 Removethebrassplugfromthevacuumpumpoil
llportSeeFigure2
2
Attachtheexibletube/captotheoilbottle;pouronly
ve(5)ouncesofvacuumpumpoilintothellport
Note: You will top off the oil in the next step as the
vacuum pump is running.
3 PressandreleasetheSTART / YESkeyWhilethe
vacuumpumpisrunning,slowlyaddoiluntilthe
levelrisestothecenterofthereservoirssightglass
4 PresstheSTOP / NOkeytostopthevacuumpump,
andinstallthebrasspluginthellport
5 PressSTART / YEStocontinue
Setup
Figure 2
CAUTION: The unit is programmed
to run the setup procedure as outlined
here. To prevent personal injury, do
NOT operate the unit at any other
time without the brass plug installed,
because the vacuum pump is
pressurized during normal operation
.
Sight Glass
Fill Port
Sight
Glass
Fill Port
Vacuum Pump
7
543175 Rev. H, June 25, 2013
Setup
Fill the Internal Storage Vessel (ISV)
1
PressSTART / YES,andtheunitautomatically
runsa5-minutevacuumtoclearallinternalair
Note: The “burping” noise heard during this
process indicates air is being purged from the
system—this is normal.
2 Afterthevacuumpumpshutsoff,attachthe
low-sidetankadaptertotheliquidvalveon
thetankAttachthelow-sideservicehoseto
thisadapterSeeFigure3
3 Openthesourcetankvalveandthelow-side
panelvalveSeeFigure4
4 Installthesourcetank,andsecureittotheunit
(usingthetankstrap)insuchawaythatliquid
refrigerantissuppliedtotheconnection
5 PressSTART / YEStobeginllingthe
internalstoragevesselAddatleast8lbs
(36kg)ofrefrigeranttoensureenough
refrigerantisavailableforcharging
 Thisprocesstakes15–20minutesTheunit
stopswhenasufcientamountofrefrigerant
hasbeentransferredtotheinternaltank,or
whenthesourcetankisempty
 PressSTOP / NOtopausePressSTOP
/ NOagaintoexit,orSTART / YESto
resume
6 Whenthellprocessiscomplete,press
STOP / NOtoexitClosethesourcetank
valveDisconnectthelow-sideservicehose
Theunitisreadyforoperation
Note: There is no need to calibrate the scale; it is
calibrated at the factory.
Figure 3
Power
Cord
Source
Tank
Strap
Low- and
High-Side
Hoses
Low- and
High-Side
Panel Valves
Figure 4
Hose
Storage
Fittings
8
Operating Instructions
Recover Refrigerant from a Vehicle
1 Emptytheoildrainbottlelocatedontheright-hand
sideoftheunit,ifnecessary,ormakenoteofthe
currentoillevelSeeFigure5
2 Connectthehigh-andlow-sidehosestothevehicle
A/Csystem
3 Openthecouplervalvesonthehoses
4 Openthehigh-andlow-sidepanelvalvesonthe
controlpanel
5 PresstheRECOVERbutton
Note: The clicking noise heard during the recovery
process indicates the solenoid is opening and closing —
this is normal.
6 Whenthesystemhasrecoveredto0psi,thevacuum
pumpstartsandrunsuntilrecoveryiscompleteThe
unitthengoesintoanautomaticoildrain—thismay
require90secondstocomplete
7 Aftertheoildrainiscomplete,thedisplayshows
 RECOVERCOMPLETE
 RECOVEREDXXXXLBS(XXXKG)
 CHECKOILBOTTLE
Note: The displayed recovered weight can vary,
depending on ambient conditions, and should not be
used as an indicator of scale accuracy.
8 Checktheoildrainbottle,andnotetheamountofoil
thatwasremovedfromtheA/CsystemThisisthe
amountofnewoilthatmustbechargedintotheA/C
systemafterevacuationiscomplete
• Useonlynewoiltoreplacetheoilremovedduring
therecyclingprocess
• Disposeofusedoilaccordingtolocal,state,and
federalregulations
RecoveryiscompleteYouarenowreadytoeither
advancetothechargeprocess,ortomakerepairstothe
A/Csystemfollowedbytheevacuationprocess
Oil Drain
Bottle
Figure 5
Operating Tips
After the RECOVER function is selected :
If system pressure is below 10 psi, the display
reads
LOWRECOVERPRESSURE
CHECKCONNECTIONS
until pressure increases, or the START / YES
button is pressed. Verify the high- and low-side
hoses are connected and coupler valves are
open. Press STOP / NO to exit.
• If 100 lbs. (45 kg) or more of refrigerant has
been recovered since the last lter-drier change,
the display reads
FILTERWEIGHTXXXLB(XXKG)
To meet SAE J-2788 requirements, it is
mandatory to replace the lter-drier after
150 lbs. (68 kg) of refrigerant has been
ltered.The unit gives a warning to replace
the lter when lter weight reaches 100 lbs.;
when lter weight reaches 150 lbs., the unit
locks out and ceases to operate.Refer to
instructions outlined in the Maintenance section
under Replace the Filter-Drier.
9
543175 Rev. H, June 25, 2013
Evacuate the A/C System
1 Ensureservicehosesareconnected,andcoupler
valvesareOPEN
2 PressVACUUM
3
PressSTART / YEStoacceptthedefaultevacuation
timeof10minutes,orenterthedesiredvacuumtime
usingthenumberkeys,andpressSTART / YES
IMPORTANT: The unit pulls a vacuum on the
vehicle A/C system to remove air and boil off
moisture that may be present in the system.
Evacuate the system for at least 10 minutes,
or follow the A/C system manufacturer’s
specications, to ensure adequate moisture
and contaminant removal.
4 TheunitevacuatestheA/Csystemandstopswhen
thespeciedamountoftimehaselapsed
 PressSTOP / NOtopausetheprocessPress
START / YEStoresume,orSTOP / NOagain
toexit
YouarenowreadytoreplenishtheA/Csystemwith
newoil,ifnecessary,ortorechargethesystemwith
refrigerant
Operating Instructions
Operating Tips
If the vacuum pump has run for 10 or more
hours without an oil change, the unit displays
VACUUMOILTIMEXX:XX
CHANGEOILNOW?
Refer to instructions outlined in the Maintenance
section under Change Vacuum Pump Oil.
Before the unit begins evacuating the A/C
system, it checks for any pressure in the
system that might damage the vacuum pump.
If pressure is detected, the unit displays
PRESSUREEXISTS
PRESSANYKEYTOEXIT
Press any key to exit, and recover refrigerant
before proceeding.
10
Recharge the A/C System
1
PressCHARGE Opentheappropriatepanelvalve(s),
dependingonwherethesystemshouldbecharged–
high-side,low-side,orboth
2 Press
CHARGE
againtochangetheunitsof
measureAcceptthedefaultweightbypressing
START / YES,orusethearrowkeystoscrolltothe
correctamount,andpressSTART / YES
3
Thedisplayreads
CHARGEINPROGRESS/DONOTDISTURB
XXXLBS(XXXKG)
 Movingorbumpingtheunitatthispointmayresult
inanincorrectreading
Note:
During a charge cycle, if the unit fails to transfer
refrigerant due to low tank pressure, the charge
process is automatically interrupted and the unit
operates in a mode to build tank pressure. Once
tank pressure is sufcient, the unit automatically
completes the charge.
When the charge cycle gets close to the weight
entered in Step 2, the unit slows down. It’ll charge,
settle, charge again, settle, etc.
4Whenthechargeiscomplete,thedisplayreads
CHARGEDXXXLBS(KG)
PRESSSTARTTOEQUALIZEHOSES
 Theusermustequalizepressureintheservicehoses
toensureallliquidrefrigeranttrappedinthehosesis
transferredtothevehicleA/Csystemforanaccurate
chargePressSTART / YEStoequalizehoses
5 Closethehigh-sidecouplervalveThedisplayreads
DISCONNECTHSHOSE
OPENPANELVALVES
ANDSTARTA/CMAX
STARTTOCONTINUE
Thehigh-sidehosemustberemovedfromthe
vehicle,andthe low-side hose must stay
connected to the vehiclewiththelow-side
coupleropen
6 Openbothpanelvalves
Operating Instructions
Operating Tips
After selecting the CHARGE function and
entering a desired weight, if the weight
entered will leave less than 2 lbs. (.91 kg) of
refrigerant in the internal tank after charge,
the charge function will not start. The display
reads
INSUFFICIENTREFRIG
PRESSANYKEYTOEXIT
Refer to the Maintenance section of this
manual for instructions to Manually Rell the
Internal Storage Vessel (ISV).
11
543175 Rev. H, June 25, 2013
Operating Instructions
Recharge the A/C System contd.
7 Placethevehiclegearselectorinparkorneutral,
withtheemergencybrakeON
8
StartthevehicleTheA/Csystemshouldbesetat
maximum
9 PressSTART / YESThedisplayreads
EQUALIZINGHOSES
REMOVELSHOSEWHEN
HS+LSARE<40PSI
PLEASEWAIT
 Thisallowsthevehicle’scompressortopull
refrigerantintotheA/CsystemWhenbothgauges
readbelow40psi,closebothpanelvalvesandthe
low-sidecouplervalveThedisplayreads
DISCONNECTLOWSIDEHOSE
STARTTOCONTINUE
10

Closethelow-sidecouplervalveRemovetheservice
hosesfromtheA/Csystem
IMPORTANT: If the low-side or high-side
coupler valves are left open, the system will
pull the refrigerant back out of the vehicle.
11
ShutOFFthevehicle
12
Press
START / YES tobeginclearingthehoses
CLEARINGHOSES
PLEASEWAIT
 Whenthehosesarecleared,thedisplayreads
CHARGECOMPLETE
CHARGEDXXXXLBS
ANYKEYEXITS
TheA/Csystemisnowreadyforuse
WARNING: To prevent personal injury,
Verify the vehicle is in park or neutral
with the emergency brake ON before
starting the engine.
Never run a vehicle without adequate
ventilation in the work area.
12
Maintenance
General Maintenance
1 Onaregularbasis,wipeofftheunitusingaclean
clothtoremovegreaseanddirt
2
Periodicallycheckinternalcomponentsforleaks;over
time,ttingscanloosenastheunitismovedOpenthe
doorpanel,andtracelinesusingaleakdetectorCheck
connectionsonthebackoftheunitTightenanyloose
ttingsorconnectionsyoumaynd
Electrical Protection
Theunitisequippedwitha15ampcircuitbreakeron
thebackpanelSeeFigure6Ifthebreakertrips,its
buttonwillpopoutAtrippedcircuitbreakerwillcause
theunittoloseallpower
Pressthecircuitbreakerbuttontoreset
Manually Fill the
Internal Storage Vessel (ISV)
Thismenuitemisusedtotransferrefrigerantfroma
sourcetanktotheinternalstoragevessel
1 PressMenu,andusearrowkeystoselectMANUAL
REFILLPressSTART / YES. Theunitdisplays
CONNECTSOURCETANK
TOLSSERVICEHOSE
OPENLSPANELVALVE
STARTTOBEGIN
2 Connectthelow-sidetankadaptertotheliquidvalve
onthetankConnectthelow-sideservicehosetothis
tankadapterOpenthelow-sidepanelvalve
3 Installthesourcetank,andsecureittotheunit
withthesourcetankstrapinsuchawaythatliquid
refrigerantissuppliedtotheconnection
4 PressSTART / YEStobeginThedisplayshows
TANKFILLINPROGRESS
TRANSFERXXLBS
5 Theunitautomaticallystopswhenthepresettankll
levelisreached,orpressSTOP / NOtoexit
6 ClosethesourcetankvalveDisconnectthelow-side
servicehose Figure 7
Side View
Circuit
Breaker
Figure 6
Back View
MAIN POWER
BREAKER
Power
Cord
Source
Tank
Strap
Low- and
High-Side
Hoses
13
543175 Rev. H, June 25, 2013
Replace the Filter-Drier
Thelter-drierisdesignedtotrapacidandparticulates,
andtoremovewaterfromrefrigerantTomeetthe
SAEJ-2788mandateforadequatemoistureand
contaminantremoval,thelter-driermustbereplaced
after150lbs(68kg)ofrefrigeranthasbeenltered
Therefore, you no longer have a choice—the
lter-drier must be replaced.Theunitgivesa
warningwhen100lbsoftheltercapacityhasbeen
used;the unit locks down when the 150 lb.
lter capacity has been reached and will no
longer functionForthisreason,alwayshaveaspare
RobinairNo34724lter-drieronhand
Check Remaining Filter Capacity
1 PressMENU
2 Usethearrowkeystoscrollthroughthemenuto
MAINTAINFILTER,andpressSTART / YES
Theunitdisplays
XXXLBSFILTERED
RECOVERLOCKOUTINXXXLBS
REPLACEFILTERNOW?
PRESSSTOPTOEXIT
3 PressSTOP / NOtoexit
Change the Filter
1 PressMENU
2 Usethearrowkeystoscrollthroughthemenuto
MAINTAINFILTER,andpressSTART / YES
Theunitdisplays
XXXLBSFILTERED
RECOVERLOCKOUTINXXXLBS
REPLACEFILTERNOW?
PRESSSTOPTOEXIT
3 PressSTART / YEStoproceed
4 Ifthereispressureinthelter,theunitbeginsa
clearingprocessWhencomplete,thedisplayreads
ENTER10DIGITSERIALNUMBERUsethe
arrowkeystoentertheserialnumberthatappears
onthenewlter-drier,andpressSTART / YES
Maintenance
IMPORTANT: Use only authentic Robinair
No. 34724 lter-driers in this machine. All
performance tests and claims are based
on using this specic lter-drier.
And only the Robinair No. 34724 lter-
drier includes the code necessary to
make the unit operable again.
Enter the Serial No. for a New Filter-Drier
Useanarrowkeytochangetheselecteddigitto
thecorrespondingnumberorletterintheserial
numberWhenthecorrectletterornumberis
displayed,pressSTART / YEStoselectitand
movetothenextdigitRepeatthisprocessuntil
theentireserialnumberhasbeenentered,and
pressSTART / YES
Operating Tips
14
5 ThedisplayreadsPLEASEREPLACEFILTER
Openthereardooroftheunitandunscrewtheold
lterSeeFigure8
6
Lookatthenewlter—verifybotho-ringsare
lubricatedandcorrectlylocatedinthegroovesSee
Figure9ThreadthenewlterintoplacePress
START / YES
Note: If the display shows SERIALNUMBERERROR,
the serial number is invalid or the lter-drier has
already been used in this unit.
7 ClosethedoorPressSTOP / NOtoexitThelter-
drierreplacementisnowcomplete
Replace the Filter-Drier contd.
Maintenance
Filter-Drier
Rear View
(without shroud)
Adjust Tank Fill Level
Whenconnectedtoarefrigerantsource,theunit
maintainsadefaultvalueof15lbsofrefrigerantinthe
internalstoragevesselThisvaluemaybeadjustedup
ordowntosuittheapplication
1PressMENU
2 Usethearrowkeystoscrollthroughthemenuto
ADJUSTTANKFILLLVL,andpressSTART /
YESTheunitdisplays
LEVEL:1500LBS
ENTERTANKFILLLVL
LIMIT:4TO17LBS
PRESSSTART/YESTOSAVE
3 Usethearrowkeystoenteravaluebetween4lbs
and17lbs,andpressSTART / YES.
Figure 8
O-rings
Figure 9
Check for Leaks
Checktheunitforleakseverythreemonths,oras
speciedbylawinyourjurisdiction
1 TurnoffMAIN POWER,anddisconnectthepower
cordfromtheoutlet
2
Openthereardoor;removetopcoverandfrontpanel
3
Usealeakdetectortoprobeallconnectionsfor
refrigerantleaksTightenttingsifaleakisindicated
4 Reassemblethebodypanels,andclosethereardoor
Inspect the unit periodically for leaks.
The manufacturer does not reimburse
for lost refrigerant.
15
543175 Rev. H, June 25, 2013
Change Vacuum Pump Oil
Formaximumvacuumpumpperformance,changethe
vacuumpumpoilafterevery10hoursofoperation(The
unitwilldisplayapromptafter10hoursofoperation)
1 PressMENUUsethearrowkeystoselect
MAINTAINVACUUMOIL,andpressSTART /
YESThedisplayshowshowlongthevacuumpump
hasoperatedsincethelastoilchange:
PUMPOILTIMEX:XX
TIMEREMAININGX:XX
CHANGEOIL?
2 PressSTART / YESThedisplayshowsVACUUM
OILCHANGETIME2:00,andcountsdowntozero
Allowthevacuumpumptorununtilitautomatically
stopsThedisplaythenshowsDRAINOLDOIL
ANDADD5OZNEWOIL
3 RefertoFigure10,andremovethebrassplugfrom
thevacuumpump’soilllport(Thepumpdrains
fasterwhenvented)
4
Removetheoildrainttingcap,anddraintheoilinto
asuitablecontainerfordisposalReplacethecap
5
Attachtheexibletubeandcaptotheoilbottle;pour
ve(5)ouncesofvacuumpumpoilintothellport
6 PressSTART / YESThedisplayshowsFILL
PUMPTOCENTEROFSIGHTGLASS,andthe
vacuumpumpstartsWhilethevacuumpumpis
running,slowlyaddoiluntilthelevelrisestothe
centerofthereservoirssightglass
7 PressSTOP / NOThecounterresetstozeroaftera
vacuumpumpoilchangehasbeencompleted
8 ReplacethebrassplugonthellportPressSTOP /
NOtoexittotheMainMenu
CAUTION: To prevent personal injury, do
NOT operate the unit at any time without the
brass plug installed, because the vacuum
pump is pressurized during normal operation.
Review the laws in your jurisdiction
to determine the correct disposal
procedure for pump oil. It is the
responsibility of the user to determine
if a material is a hazardous waste at
the time of disposal. Ensure you are
in compliance with all applicable laws
and regulations.
Maintenance
Oil Drain Fitting
Oil Fill Port
Sight Glass
Figure 10
16
Repl.
Component Part No.
Filter-Drier 34724
ServiceCouplerSet
(high- and low-side couplers) 18192
ServiceHoseSet
(high- and low-side hoses) 34722
VacuumPumpOil
(case of 12 quarts) 13203
VacuumPumpOil
(case of 4 gallons) 13204
MaintenanceKit 13172
VinylDustCover(optional) 17492
TankAdapter 16301
Replacement Parts
Maintenance
Scale Calibration
Thecalibrationcheckisusedtoensuretheunit’sinternal
scaleisalwayscalibratedDuringthistest,useonlythe
calibrationweightthatisprovidedwiththeunit
1 PressMenu
2 UsethearrowkeystoscrolltoCALIBRATION
CHECK
3 RefertoFigure11,andverifythemagnetonthe
bottomoftheunitiscleanPressSTART / YES
4 Thedisplayreads
ATTACHTHEWEIGHTTOTHEBOTTOMOFTHE
MACHINE
PRESSSTARTTOCONTINUE
5Attachtheweightprovidedtothemagnetonthe
bottomoftheunitPressSTART / YES
Magnet
• IfthedisplayshowsCALIBRATIONAPPROVED,thescaleisincalibrationPressanykeytoexit
• IfthedisplayshowsCALIBRATIONREJECT,thescaleisoutofcalibrationCallyourlocalservice
centerforassistance
• IfthedisplayshowsCALIBRATIONERROR1,verifythecalibrationweightiscorrectlyattached
tothemagnet,andverifythemagnetiscleanwithnothingattachedtoitIfthatdoesnotcorrectthe
problem,callyourlocalservicecenterforassistance
Tank Recertication
Theinternalstoragevessel(ISV)inthisunitisa
DOT-approvedtankthatcarriesadatecodeISVs
mustberecertiedeveryveyears
TodeterminethedatecodeoftheISVinyour
Robinairunit,removethefrontpaneloftheunitIt
shouldbepossibletoreadthedatecodestampedon
theISV
Ifthedatecodereadsbeyondtheve-yearlimit,
contactaRobinairservicecenterforassistance
Figure 11
Rev. November 1, 2005
This product is warranted to be free from
defects in workmanship, materials, and com-
ponents for a period of one year from date of
purchase. All parts and labor required to repair
defective products covered under the warranty
will be at no charge. The following restrictions
apply:
1. The limited warranty applies to the original
purchaser only.
2. The warranty applies to the product in
normal usage situations only, as described
in the Operating Manual. The product must
be serviced and maintained as specied.
3. If the product fails, it will be repaired or
replaced at the option of the manufacturer.
4. Transportation charges for warranty service
will be reimbursed by the factory upon
verication of the warranty claim and sub-
mission of a freight bill for normal ground
service. Approval from the manufacturer
must be obtained prior to shipping to an
authorized service center.
5. Warranty service claims are subject to
authorized inspection for product defect(s).
6. The manufacturer shall not be responsible
for any additional costs associated with a
product failure including, but not limited to,
loss of work time, loss of refrigerant, cross-
contamination of refrigerant, and unauthor-
ized shipping and/or labor charges.
7. All warranty service claims must be made
within the specied warranty period. Proof-
of-purchase date must be supplied to the
manufacturer.
8. Use of recovery/recycling equipment with
unauthorized refrigerants or sealants will
void warranty.
Authorized refrigerants are listed on the
equipment or are available through the
Technical Service Department.
The manufacturer prohibits the use of
the recovery/recycling equipment on air
conditioning (A/C) systems containing
leak sealants, either of a seal-swelling or
aerobic nature.
This Limited Warranty
does NOT apply if:
The product, or product part, is broken by
accident.
The product is misused, tampered with, or
modied.
The product is used for recovering or recy-
cling any substance other than the specied
refrigerant type. This includes, but is not
limited to, materials and chemicals used to
seal leaks in A/C systems.
Robinair
Limited Warranty Statement
Declaración de garantía
limitada Robinair
Revisión del 1 de noviembre de 2005
Se garantiza que este producto no posee defec-
tos de mano de obra, materiales y componentes
por el período de un año a partir de la fecha de
compra. Todas las partes y mano de obra re-
querida para reparar los productos con defecto
cubiertos bajo la garantía no tendrán costo.
Aplican las siguientes restricciones:
1. La garantía limitada aplica al comprador
original únicamente.
2. La garantía aplica al producto en situaciones
de uso normal únicamente, como lo indica
el Manual de funcionamiento. Al producto
se le debe dar servicio y mantenimiento
como se especica.
3. Si falla el producto, se debe reparar o reem-
plazar a discreción del fabricante.
4. Los cargos de transporte de servicio de ga-
rantía serán reembolsados por la fábrica al
vericar el reclamo de garantía y presentar
una boleta de ete por servicio terrestre
regular. Se debe obtener la aprobación
del fabricante antes de hacer el envío a un
centro de servicio autorizado.
5. Los reclamos de servicio de garantía están
sujetos a inspección de defectos del pro-
ducto.
6. El fabricante no será responsable de los
costos adicionales relacionados con fallas
en el producto, que incluyen pero no se
limitan a, tiempo improductivo, pérdida de
refrigerante, contaminación de refrigerante
y envío no autorizado o cargos por mano de
obra.
7. Todo reclamo de servicio de garantía se
debe hacer dentro del período de garantía
establecido. Se debe proporcionar la fecha
de la prueba de compra al fabricante.
8. El uso de equipo de recuperación/reciclaje
con refrigerantes o selladores no autoriza-
dos anula la garantía.
Los refrigerantes autorizados se indican
en el equipo o están disponibles a través
del Departamento de servicio técnico.
El fabricante prohíbe el uso de equipo
de recuperación/reciclaje en sistemas de
aire acondicionado (A/C) con fugas de
sellador, ya sea porque un sello se ina o
es de naturaleza aeróbica.
Esta garantía limitada NO aplica si:
El producto, o parte de éste, se rompe ac-
cidentalmente.
El producto se usa incorrectamente, se
adultera o modica.
El producto se usa para recuperar o reciclar
cualquier sustancia que sea diferente al tipo
de refrigerante establecido. Esto incluye,
pero no se limita a materiales y productos
químicos utilizados para sellar fugas en
sistemas de A/C.
Énoncé de la garantie limitée
de Robinair
Révisée le 1er novembre 2005
Ce produit est couvert contre les défauts de ma-
tériau, de fabrication et de composant pendant
un an à compter de la date d’achat. Toutes les
pièces et la main-d’œuvre nécessaires aux répa-
rations sous garantie sont sans frais. Toutefois,
les restrictions suivantes s’appliquent :
1. La garantie limitée s’applique uniquement à
l’acheteur initial.
2. La garantie s’applique uniquement au
produit utilisé dans des conditions de
fonctionnement normales conformément au
manuel d’utilisation. Il doit être réparé et
entretenu conformément aux spécications.
3.
Si le produit subit une défaillance, il sera
réparé ou remplacé à la discrétion du fabricant.
4. Les frais de transport pour les réparations
sous garantie sont remboursés par l’usine
après l’évaluation de la réclamation au
titre de la garantie et après la soumission
d’une facture de transport terrestre standard.
L’approbation du fabricant est requise avant
l’expédition du produit à un atelier de répa-
ration autorisé.
5. Les réclamations au titre de la garantie sont
sujettes à l’inspection du produit défectueux
par un personnel autorisé.
6.
Le fabricant ne peut être tenu responsable pour
tout coût supplémentaire lié à la défaillance
du produit incluant, sans toutefois s’y limiter,
les interruptions de fonctionnement, la perte
de liquide frigorigène, la contamination des
liquides frigorigènes et l’expédition et/ou les
frais de main-d’œuvre soumis par des ateliers
non autorisés.
7. Toute réclamation pour des réparations au
titre de la garantie doit être soumise durant
la période de garantie. Une preuve d’achat
doit être fournie au fabricant.
8.
L’utilisation d’un appareil de récupération et
de recyclage avec du liquide frigorigène ou
des scellants non spéciés annule la garantie.
Les liquides frigorigènes autorisés sont
indiqués sur l’appareil, ou ils peuvent
être obtenus auprès du Service technique.
Le fabricant interdit l’utilisation d’un ap-
pareil de récupération et de recyclage dans
les systèmes de climatisation contenant des
colmatants pour fuites, que ce soient des
scellants à dilatation ou aérobiques.
Cette garantie limitée NE s’applique
PAS si le produit :
ou une partie du produit a été endommagé
par un accident.
a été utilisé de façon inadéquate, ou qu’il a
été altéré ou modié.
est utilisé pour la récupération et le recy-
clage de substances autres que le type de
liquide frigorigène spécié. Ces substances
comprennent, sans toutefois s’y limiter, les
matériaux et les produits chimiques utilisés
pour colmater les fuites des systèmes de
climatisation.
543175 (Rev. H, June 25, 2013) © Bosch Automotive Service Solutions
Visit our web site at www.robinair.com or call our toll-free
Technical Support Line at 800-822-5561
in the continental U.S. or Canada.
In all other locations, contact your local distributor. To help us serve you better, please be prepared to provide
the model number, serial number, and date of purchase of your unit.To validate your warranty, complete the
warranty card attached to the unit, and return it within ten days from date of purchase.
NATIONWIDE NETWORK OF AUTHORIZED SERVICE CENTERS
If your unit needs repair or replacement parts, contact the service center in your area. For help in locating a
service center, call the toll-free technical support line or visit www.robinair.com.
Visite nuestro sitio web en www.robinair.com o llame sin costo a
la línea de Asistencia técnica al 800-822-5561
en EE.UU. continental o Canadá.
En todas las demás ubicaciones, comuníquese con su distribuidor local. Para ayudarnos a servirle mejor, tenga a mano
el número de modelo, número de serie y fecha de compra de su unidad. Para validar la garantía, complete la tarjeta de
garantía anexa a su unidad y devuélvala dentro de los diez días siguientes a la fecha de compra.
RED NACIONAL DE CENTROS DE SERVICIO AUTORIZADOS
Si su unidad necesita reparaciones o partes de reemplazo, comuníquese con el centro de servicio de su área. Para ob-
tener ayuda para ubicar un centro de servicio, llame sin costo a la línea de asistencia técnica o visite www.robinair.com.
Visitez notre site Web à www.robinair.com ou appelez sans frais
le soutien technique au 800-822-5561
sur le territoire continental des États-Unis ou au Canada.
Pour tout autre endroit, communiquez avec votre distributeur local. An de nous aider à mieux vous servir, soyez prêt à
nous donner le numéro de modèle, le numéro de série et la date de l’achat de votre unité. An de valider votre garantie,
remplissez la carte de garantie jointe à votre système et retournez-la dans les dix jours de la date d’achat.
RÉSEAU NATIONAL DES CENTRES DE SERVICE AUTORISÉS
Si votre unité a besoin d’être réparée ou à besoin de pièces de remplacement, communiquez avec le centre de service de
votre région. Pour vous aider à localiser un centre de service, appelez sans frais la ligne de soutien technique ou visitez le
www.robinair.com.
The Robinair 34288 unit is designed to meet all applicable agency certications, including Underwriter's Laboratories, Inc., SAE
Standards, and CUL. Certain state and local jurisdictions dictate that using this equipment to sell refrigerant by weight may not be
permitted. We recommend charging for any A/C service by the job performed. This weight scale provides a means of metering the
amount of refrigerant needed for optimum A/C system performance as recommended by OEM manufacturers
La unidad Robinair 34288 está diseñada para cumplir con todas las certicaciones de agencia aplicables, incluyendo Under-
writer’s Laboratories, Inc., Estándares SAE y CUL. Ciertas jurisdicciones estatales y locales prescriben que el uso de este equipo
para vender refrigerante por peso es posible que no sea permitido. Recomendamos que se cobre el trabajo realizado por dar
servicio al aire acondicionado. Esta escala de peso proporciona un medio para medir la cantidad de refrigerante que se necesita
para el rendimiento óptimo del sistema de aire acondicionado, tal como lo recomiendan los fabricantes OEM.
Le modèle 34288 a été conçu pour répondre aux certications applicables de la Underwriter’s Laboratories, Inc., aux normes SAE
et CUL. Certains endroits dictent l’utilisation de cet équipement et il peut arriver que la vente de uide frigorigène en fonction du
poids puisse être interdite. Nous vous recommandons de facturer les services de climatisation en fonction du travail effectué. Ce
poids de tarication permet de calculer la quantité de uide frigorigène nécessaire pour un rendement optimum de la climatisation,
tel qu’il est recommandé par les fabricants de l’équipement d’origine.
Due to ongoing product improvements, we reserve the right to change design, specications, and materials without notice.
Debido a las constantes mejoras del producto, nos reservamos el derecho de cambiar diseño, especicaciones y materiales sin aviso.
En raison des améliorations constantes apportées à nos produits, nous nous réservons le droit de changer de concept, de spécications et de matériaux sans préavis.
655 Eisenhower Drive
Owatonna, MN 55060 USA
Tech Services: 1-800-822-5561
Fax: 1-866-259-1241
Customer Service: 1-800-533-6127
Fax: 1-800-322-2890
Web site: www.robinair.com