Roost RSW200A 2.4 GHz Wi-Fi Module User Manual user Guide

Roost Inc. 2.4 GHz Wi-Fi Module user Guide

user Guide

Roost User Manual RSW200A Transmitter Module
User Guide Version: 1a
Publication date: Jan 3, 2018
©2018 Roost, Inc. All rights reserved. The
Roostword mark and logo are trademarks of
Roost, Inc.
The Wi-Fi Certified Logo is a logo of
Wi-Fi Alliance®. All other logos and trademarks
are the property of their respective
owners. See www.getroost.com/patents for a list of
applicable patents and/or patent applications.
No part of this publication may be stored,
reproduced, transmitted or distributed, in whole or
in part, in any manner,
electronic or otherwise,
whether or not for a charge or other or no
consideration, without the prior written permission
of
Roost, Inc. Requests for permission to store,
reproduce, transmit or distribute materials may be made to the following address:
Roost, Inc.
1250 Borregas Avenu
Sunnyvale, CA 94089
support@getroost.com
1) Compatibility
2.4GHz Band ONLY
2) FCC Notice to OEM
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired operation.
CAUTION:
Changes or modifications to this unit not
expressly approved by Roost, Inc. could void the user’s authority to operate
this equipment.
Note: This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful
interference in a
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed
and
used in accordance with the instructions,
may cause harmful interference to radio communications. However, there
is no
guarantee that interference will not occur in a
particular installation. If this equipment does
cause harmful
interference to radio or
television reception, which can be determined
by turning the equipment off and on, the user
is
encouraged to try to correct the interference
by one or more of the following measures:
1.
Reorient the Roost Smart Monitor
2. Consult getroost.com/support for help
Radiation Exposure Statement:
This equipment complies with the FCC radiation exposure limit set forth for an
uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between
radiator and your body.
OEM Warning
:
The modular transmitter must be equipped with either a permanently affixed label or must
be capable of electronically displaying its FCC identification number – FCC ID: 2AE5A-RSW200A. If the
FCC identification number is not visible when the module is installed inside another device, then the outside
of the device into which the module is installed must also display a label referring to the enclosed module.
This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: 2AE5A-
RSW200A.” Any similar wording that expresses the same meaning may be used. The Grantee may either
provide such a label, an example of which must be included in the application for equipment authorization,
or, must provide adequate instructions along with the module which explain this requirement. In the latter
case, a copy of these instructions must be included in the application for equipment authorization.
3) ISEDC Notice
This device complies with Innovation, Science, and Economic Development Canada license-exempt RSS standard(s).
Operation is subject to the following conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired operation of the
device.
Cet appareil est conforme à Industrie Canada une licence standard RSS exonérés (s). Son fonctionnement est soumis aux
deux conditions suivantes:
Cet appareil ne doit pas provoquer d’interférences
Cet appareil doit accepter toute interference recue, y compris les interferences pouvant provoquer un functionnement
indésirable de l’appareil..
Radiation Exposure Statement:
This equipment complies with the IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the
radiator and your body.
Enonće d’exposition aux ravonnements:
Cet équipment est conforme aux limites d’exposition aux rayonnements ioniques
RSS-102 Pour un environnement incontrôlé. Cet équipement doit être installé et utilisé avec un Distance minimale de 20 cm
entre le radiateur votre corps.
OEM Warning
:
The modular transmitter must be equipped with either a permanently affixed label or must
be capable of electronically displaying its ISEDC identification number – IC: 20891-RSW200A. If the ISEDC
identification number is not visible when the module is installed inside another device, then the outside of
the device into which the module is installed must also display a label referring to the enclosed module. This
exterior label can use wording such as the following: “Contains Transmitter Module IC: 20891-RSW200A.”
Any similar wording that expresses the same meaning may be used. The Grantee may either provide such
a label, an example of which must be included in the application for equipment authorization, or, must
provide adequate instructions along with the module which explain this requirement. In the latter case, a
copy of these instructions must be included in the application for equipment authorization.
4) Safety Information
WARNING: Do not expose this Roost RSW200A transmitter module
to excessive heat, direct sunlight, or fire. Do
not
expose to excessive humidity, rain,
moisture or other liquids. Store at room temperature between 40 and 80
degrees F for best results.
WARNING: Keep out of reach of children. Ingestion hazard. Harmful if swallowed.
5) Disposal Information
The Roost RSW200A Transmitter Module Must be Recycled or Disposed of Properly.
When the Roost RSW200A Transmitter module is no longer
functional, please dispose of it
properly, following
the
guidelines in accordance with applicable
regulations for your country. In most countries,
electronic printed circuit boards
must be recycled.
6) No Lifesaving Uses of the Services
The
Roost RSW200A Transmitter module
, Monitor app (including mobile and web applications), the Smart Monitor
device, and the Smart Monitor software may be collectively referred to as the “Services”.
The Roost Smart Monitor APP is
not an alarm. The apps and device software are intended to be
accessed and used for non-critical information
and
control of the smart Monitor hardware. You will not
rely on the Services for any health, lifesaving,
or emergency
purposes. Under no circumstances should you enter into a life-
threatening environment. The Services (on their
own or in combination with third-party
products or services) are not a third-party
monitored emergency notification
system and
are not certified for emergency response.
Roost will not dispatch emergency authorities
to your home in
the event of an emergency
7) Electrical Specifications of the Roost RSW200A Transmitter Module
Input Operating Voltage Range: 3V minimum, 3.6V Maximum, 3.3V nominal
Input Operating Voltage during Sleep State: 2.5V Minimum
Absolute Maximum Input Voltage: 5V
Input Current consumption (with no load on Control Interface Logic Signals), 1uA nom Sleep, 400mA
max during Transmit
Digital Interface Logic Levels: CMOS
o
high level minimum of Input Operating Voltage – 0.6V
o low level maximum of 0.45V
Digital Interface Output Drive Level: 8mA maximum
RF Transceiver operation: 2.4GHz Band 802.11 B,G,N
Absolute Maximum Transmit power: +20.5dBm
RF Test Signal Connector Type: Murata MM8030-2610
Normal Operating Temperature Range: -0C to +60C
Operable Temperature Range: -30C to +70C
Maximum Humidity limit: 60C with 100% relative humidity for 24 hours operating
Mechanical Vibration limit: Single axis sinusoidal for 4 hours,10-30-10Hz sweeps at 2 cycles/min with
0.55mm displacement
Mechanical Shock limit: half sine, 109G@8.0mSec. Two shocks in all three axes for a total of 12
shocks
8) HW Integration of the Roost RSW200A Transmitter Module into OEM product
The RSW200A Transmitter Module is meant for Internet of Things applications.
The module is provided as a PCBA
As good practice with all radio PCBs, it is expected the mother board integrating the RSW200A Transmitter Module
will have, at a minimum, a continuous ground plane in the area adjacent to the RSW200A Transmitter. This ground
plane can be on the top, bottom, or internal layers and should be connected to the RSW200A Ground pin (connector
H6) in a continuous fashion
The RSW200A Interface Connector control signals are TTL, Open Drain, or Analog as specified in the Limited Modular
Circuit Description.
The RSW200A Transmitter Module is a Limited Modular Certification so further Spurious Emissions scanning is
required to maintain proper certification authorization.