Rooti Labs M2-2016 Rooti RX User Manual InstructionManual revJ 20160307

Rooti Labs Limited Rooti RX InstructionManual revJ 20160307

User manual

Download: Rooti Labs M2-2016 Rooti RX User Manual InstructionManual revJ 20160307
Mirror Download [FCC.gov]Rooti Labs M2-2016 Rooti RX User Manual InstructionManual revJ 20160307
Document ID2945377
Application IDk6Jcv4Ep8OEvLwNeeNnEUA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize58.35kB (729336 bits)
Date Submitted2016-03-30 00:00:00
Date Available2016-09-26 00:00:00
Creation Date2016-03-14 11:26:32
Producing SoftwareAdobe PDF library 10.01
Document Lastmod2016-03-14 11:26:32
Document TitleInstructionManual_revJ_20160307
Document CreatorAdobe Illustrator CS6 (Windows)

Rooti Labs Limited
5F-1, No.71, Zhouzi St., Neihu Dist.,
Taipei City 114, Taiwan (R.O.C.)
Tel: +886 (2) 2656-0618
E-mail: service@rootilabs.com
https://www.rootilabs.com/
EC REP
Wellkang Ltd (www.CE-marking.eu)
29 Harley St., London W1G 9QR, UK 0598
Authorised Representative in the European community
ECG Event Recorder
0560
Instruction Manual
User Manual V1.0
BEFORE USE
TABLE OF CONTENTS
BEFORE USE
Introduction
Product Description
Safety Information
Icon Explanation
Operating the Rooti Rx
Care and Maintenance
Before Taking a Measurement
OPERATION INSTRUCTIONS
Rooti Rx
Components
Rooti Link
Instruction Manual
Features
Applications
Getting Started
LED Indications
12
Troubleshooting
12
Specification
13
FCC Statement
15
Introduction
Thank you for purchasing the Rooti Rx.
Fill in for future reference
DATE PURCHASED:
SERIAL NUMBER:
• Staple your purchase receipt here
Product Description
The Rooti Rx is a compact physiological monitoring module. The
intended use of Rooti Rx is to provide a facility in the home, workplace
and for recording and transmitting single lead EGG data to a qualified
receiving station for interpretation by medical professionals. The Rooti
Rx stores one lead electrocardiography(ECG) signals and recording data
transmission via WiFi.
To interpret recording data should be skilled at the level of a technician,
doctor, nurse, or medical specialist.
The Rooti Rx comes with the following components:
•Rooti Rx •Charging Dock •Electrode Sticker x3
•Instruction Manual
Please read this instruction manual
thoroughly before using the unit.
Please keep for future reference.
Safety Information
To assure the correct use of the product basic safety measures
should always be followed including the warnings and cautions
listed in this instruction manual.
Icon Explanation
60
Do not reuse
Manufacturer
Temperature limitation
Date of Manufacture
-10
Read this instruction manual
thoroughly before using the
unit.
Type BF applied part
EC REP
LOT
IP58
0598
CE Certificate
0560 RF CE Certificate
Authorised representative in
the European Community
Use By
Battery must be recycled
Direct Current
Batch Code
Ingress Protection
5:Dust Protected
8:Protected against the effects of
temporary immersion in water
SN
Serial Number
Caution:
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury to the user or patient or
damage to the equipment or other property.
Operating The Rooti Rx
Read all of the information in the instruction manual and any other
literature in the box before operating the unit.
Subjects fitted with a heart pacemaker should not use the Rooti Rx.
The Rooti Rx should not be used in conjunction with any defibrillator, including implanted or AED devices.
Please use standard USB power outlet. The USB power outlet must
be certified to IEC/EN 60601-1 for 2 MOPP and examined regularly.
When wearing the Rooti Rx to shower, RED LED flashes temporarily.
Wipe dry the Rooti Rx after shower, RED LED stops flashing. If RED LED
still flashes, please change new Electrode Pads.
If LED continues flashing after all these steps or user has any other
problem, please CONSULT DOCTOR.
If user feels itchy and allergic after the electrode sticker long-time
attached to skin, please remove the sticker and ask users to CONSULT
DOCTOR.
We advise pregnant women and children to use this product under
the supervision of a doctor.
No modification of this equipment is allowed.
Be aware of choking resulting from a child swallowing a small part
that has become detached from Rooti Rx.
Care And Maintenance
Operate the Rooti Rx only as intended. Do not use the Rooti Rx for
any other purpose.
Do not submerge the Rooti Rx or any of the components in water.
Do not wear Rooti Rx to swimming or taking a bath.
Store the Rooti Rx and the components in a clean, safe location.
(-10~60 C / 10~95% R.H. (noncondensing))
Ingress Protection
5:Dust Protected
8:Protected against the effects of temporary immersion in water
The conductive parts of electrodes and associated connectors for
type BF or CF applied parts, including neutral electrode, should not
contact other conductive parts including earth.
The disposal of Rooti Rx and accessories follows normal electronic
waste recycling method.
Side Effect
If long time wearing Rooti Rx, users may feel itchy and a little bit
allergic on skin.
Contraindication
following patient must be follow the doctor's instructions to use:
1. Chronic Disease patients
2. Allergic to Polyester patient
3. Pregnant woman
4. Children
5. Breastfeeding women
Before Taking a Measurement
Components:
To ensure a reliable measurement, follow these recommendations:
- We suggest using alcohol pad to clean the back of Rooti Rx (Sensor
Pad) before and after use.
- During recording, please do not take off the Rooti Rx.
- Electrode Sticker is only for ONE time use. Please change a new
sticker every time before use.
- When wearing the Rooti Rx to shower, RED LED flashes temporarily.
Wipe dry the Rooti Rx after shower, RED LED stops flashing. If RED LED
still flashes, please change new monitoring electrodes. If LED continues
flashing after all these steps or user has any other problem, please
CONSULT DOCTOR.
- Please make sure to put the Rooti Rx onto the Charging Dock before
data downloading.
To have a better using experience, read the following items.
- Quick RED LED flashing indicates LOW POWER while slow RED LED
flashing indicates LEAD OFF.
- When connecting to Rooti Rx, users cannot use the internet at the
same time.
- If user feels itchy and allergic after the electrode sticker long-time
attached to skin, please remove the sticker and ask users to CONSULT
DOCTOR.
Charging Dock
OPERATION INSTRUCTIONS
Rooti Rx
Front
Function
Button
Back
Sensor
Pad
LED
Notice: We suggest using ALCOHOL PAD to clean the
back of Rooti Rx (Sensor Pad) before and after use.
USB
Charger
Electrode Sticker
Front
Dock
Back
Double-sided tape
(attach to Rooti Rx)
Snap
Double-sided tape
(attach to user’s skin)
Rooti Link
Snap (Snap with self-prepared
Monitoring Electrodes)
Rooti Rx has to be worked along with App “Rooti Link”. Download
“Rooti Link” in Apple Store and follow the on-screen instruction to set
up the Rooti Rx.
Compatibility
•iOS 8+
•iPhone 5+
•iPad Mini
•iPad 3+
Transmit to Mobile Device Application
1. Inside the box
Rooti Rx x1
Electrode Sticker pack x3
Charging Dock x1
Instruction Manual x1
ECG Event Recorder
Instruction Manual
Features
ECG (EC38 Type 3)
Skin Temperature
Uses Standard ECG Electrodes
Wi-Fi data download
Rechargeable
USB charging
Red/ Green/ Blue LED
Function button
IP58
Applications
Hospital General Care
Skilled Nursing Facilities
Home based Remote Patient Monitoring
Physiological status monitoring in real world situations
an
ua
Getting Started
Instruction Manual
2. Charge Rooti Rx
Put the Rooti Rx into Charging Dock and plug it into power outlet,
meanwhile, Green LED flashes. When full-charged
the Rooti Rx, LED lights out.
*ATTENTION: To achieve maximum
product utility, please make sure to
fully charge the Rooti Rx before
use.
3. Download RootiLink App for your
patient
First, help your patient to set up
RootiLink, the app for Rooti Rx. Ensure
smart device is connected to Internet and
search for “RootiLink” in App Store, download and set up a RootiLink account for
your patient.
(1) After downloaded,
start RootiLink.
(2) Sign up a new account
for RootiLink, set up your
personal profile.
(3) Tap “Device Set Up” in main page.
(4) Follow the instructions in the app and connect RootiLink with
Rooti Rx.
Notice: After connecting Wi-fi in Apple system, quickly press Home
key twice to go back RootiLink.
4. Offer Rooti Rx as a Tool for Your Patients
Follow the instructions in the app, set up Rooti Rx for your patients
and start recording.
(1) Step 1: Remove double-sided tape in the front side of Eletrode
Sticker.
(2) Step 2: Stick the Rooti Rx onto the FRONT of Electrode Sticker.
Aim the circle steel dot to the hole of sticker.
(3) Step 3: Snap in Monitoring Electrodes* to Electrode Sticker.
(4) Step 4: Remove adhesive tapes on the BACK of Electrode Sticker.
(5) Step 5: Ask patients to stand still, chin
up and chest out. Attach Rooti Rx on top of
patients’ left chest. Make sure the sticker
can cover on skin properly without abnormal
stretching or twisting. (Approximately 3cm
upper from left nipple.)
Chest out when
attach Rooti RX
*ATTENTION:
a. Please use certificated self-prepared standard Monitoring
Electrodes sold in general pharmacy.
b. During the recording, teach patients to short press the button
when they feel uncomfortable, and Rooti Rx will record ECG tags.
(1) Reopen RootiLink.
Short press to tag
c. If Rooti Rx leads off or not attaches well to your body, Red LED will
keep lighting up. Please go back to hospital for medical support.
5. Preview mode
After set up Rooti Rx, check the patients’ ECG signal/ skin temperature through Preview mode of RootiLink. Make sure the ECG signal is
stable and well-performed.
(2) Remove electrode sticker
from the Rooti Rx.
(3) Follow the on-screen instruction
in the app. Long press the Rooti Rx
function button and activate Wi-Fi
advertising (BLUE LED) to reconnect Rooti Rx with RootiLink.
(4) Tap “Download” and put the Rooti Rx into Charging Dock. Plug
into power through USB charger.
(5) During the download, Rooti
Rx flashes Blue LEDs quickly.
(6) When download completed,
you can review ECG Tag or ECG
Date in History Data.
6. Set up recording days and countdown timer starts
counting.
At this time, Rooti Rx will work as a standalone recorder.
7. Review Record for Your Patients
After recording, help your patients to download their record in the
app. Review history ECG data as your further diagnose references.
10
11
Specification
LED Indications
Short Press
Long Press
Battery Low
On Body
Lead Off
Record ECG tags
Off Body
N/A
Pairing:
Uploading:
Battery Check: full
On Base
Battery Check: Low
Charging:
Finish Charging:
N/A
Troubleshooting
When short press the Rooti Rx, it indicates Red LED.
Please charge the Rooti Rx by plugging into the Charging Dock.
When connecting my phone with the Rooti Rx, why it stucks
in the Wi-Fi searching list?
iOS: Press “Home Key” twice to go back RootiLink
Why is Rooti Rx keeps flashing RED?
Rooti Rx is LOW BATTERY, please CONSULT DOCTOR/
MEDICAL PROFESSIONALS.
Rooti Rx is in LEAD OFF status
1. Please adjust Monitoring Electrodes and Electrode Sticker, see if
they are finely attached.
2. If 1. cannot solve the problem, change new Monitoring Electrodes.
3. If 1. & 2. are not available to solve this problem, please CONSULT
DOCTOR/ MEDICAL PROFESSIONALS.
I am charging the Rooti Rx, it’s originally lightening GREEN,
but it’s now no LED signal.
Rooti Rx is now fully battery charged.
12
Rooti Rx
Brand
Rooti
Model
Rooti Rx
Item
Rooti Rx
Measurement Method
One Lead Electrocardiogram, EKG/ECG
Rating
Direct Current 3.7v 250 mAh
Power Source
Lithium-ion Polymer
Battery Pack 250 mAh AHB521630
Battery Life
2 year or 500 times
Expected Service Life: 1 year
Operating Environment
Record mode
Environment
0~40 C
20~93 %R.H.
80,0 kPa to 101,3 kPa
(noncondensing)
Charging mode
and others
0~50 C
20~93 %R.H.
80,0 kPa to 101,3 kPa
(noncondensing)
Storage and transportation -10~60 C / 10~95 %R.H.(noncondensing)
Environment
Main Unit Weight
14 g ± 1 g
Dimensions for Main Unit 62 * 22.5 * 8.45 mm
Accessory
Charging dock, Electrode sticker
13
Charging Dock
Brand
Rooti
Model
Rooti Rx
Item
Charging Dock
0~50 C / 20~93 %R.H.
Operating Environment Atmospheric pressure 80,0 kPa to 101,3 kPa
(noncondensing)
Service Life
Expected Service Life: 1 year
Storage and transportation -10~60 C / 10~95 %R.H.(noncondensing)
Environment
Main Unit Weight
18 g
Dimensions for Main Unit 64 * 30 * 7 mm
Electrode Sticker
Brand
Rooti
Model
Rooti Rx
Item
Electrode Sticker
0~50 C / 20~93 %R.H.
Operating Environment Atmospheric pressure 80,0 kPa to 101,3 kPa
(noncondensing)
Federal Communications Commission (FCC) Statement
(1) This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) this device may not cause harmful interference and
2) this device must accept any interference received, including interference that may cause
undesired operation of the device.
(2) You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment.
(3) This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC RF Exposure:
“For body worn operation, this Rooti RX has been tested and meets FCC RF exposure guidelines
when used with an accessory that contains no metal and that positions the Rooti RX a minimum
of **5mm** from the body. Use of other accessories may not ensure compliance with FCC RF
exposure guidelines.”
To comply with the FCC RF exposure compliance requirements, this device and its antenna must
not be co-located or operating in conjunction with any other antenna or transmitter.
European Union Regulatory Notice
This device bearing the CE marking is in compliance with the essential requirements and other
relevant provisions of Directive : 1999/5/EC. This device complies with the following harmonized
European standards.
Radio: ETSI EN 300 328 V1.9.1 : 2015 / BS EN 62479 : 2010
EMC: EN 301 489 –1 v1.9.2: 2011 / EN 301 489 –17 v2.2.1: 2012
EN 55022: 2010+AC: 2011
EN61000-3-2 : 2006+A1:2009+A2:2009 / EN61000-3-3 : 2008
EN 61000-4-2 : 2009 / EN 61000-4-5 : 2006
EN 61000-4-3 : 2006+A1:2008+A2:2010 / EN 61000-4-6 : 2014
EN 61000-4-4 : 2012 / EN 61000-4-11 : 2004
Safety : EN 60950-1: 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013
Storage and transportation -10~60 C / 10~95 %R.H.(noncondensing)
Environment
Main Unit Weight
3.2 g
Dimensions for Main Unit 32.7 * 115 * 5.2 mm
14
©2016 Rooti Labs Limited. All rights reserved. Reproduction in whole or in part is prohibited.
Rooti and Rx are trademarks of Rooti Labs Limited, applied in the U.S. and other countries.
15
Guidance and manufacturer’s declaration -electromagnetic emissions
The Rooti RX is intended for use in the electromagnetic environment specified below.
The customer or the user of the Rooti RX should assure that it is used in such an environment.
Emission test
Compliance
Electromagnetic environment-guidance
RF emissions
CISPR 11
Group 1
The Rooti RX uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely
to cause any interference in nearby electronic equipment.
RF emissions
CISPR 11
Class B
Harmonic emissions
IEC 61000-3-2
Class A
The Rooti RX is suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supply network
that supplies buildings used for domestic purposes.
Voltage fluctuations
/flicker emissions
IEC 61000-3-3
Compliance
Guidance and manufacturer’s declaration-electromagnetic immunity
The Rooti RX is intended for use in the electromagnetic environment specified below.
The customer or the user of the Rooti RX should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level
Conducted RF
IEC 61000-4-6
3 Vrms
150 KHz to 80 MHz
3 Vrms
Radiated RF
IEC 61000-4-3
3 V/m
80MHz to 2,5 GHz
3 V/m
Recommended separation distance:
d = 1,2 √P
d = 1,2 √P 80MHz to 800 MHz
d = 2,3 √P 800MHz to 2,5 GHz
Where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey, should
be less than the compliance level in each frequency
range.
Interference may occur in the vicinity of
equipment marked with the following symbol:
Guidance and manufacturer’s declaration-electromagnetic immunity
The Rooti RX is intended for use in the electromagnetic environment specified below.
The customer or the user of the Rooti RX should assure that it is used in such an environment.
Immunity test
IEC 60601
test level
Compliance level
Electromagnetic
environment-guidance
Electrostatic
discharge(ESD)
IEC 61000-4-2
+ 6 kV contact
+ 8 kV air
+ 6 kV contact
+ 8 kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative
humidity should be at least 30%
Electrical fast
transient/burst
IEC 61000-4-4
+ 2kV for power
supply lines
+ 1kV for input/
output lines
+ 22kV for power
supply lines
Not applicable
Mains power quality should be that of
a typical commercial or hospital
environment.
Surge
IEC 61000-4-5
+ 1kV line(s) to line(s)
+ 2kV line(s) to earth
+ 1kV differential
mode Not applicable
Mains power quality should be that of a
typical commercial or hospital
environment.
Voltage Dips, short
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
<5% UT(>95% dip
in UT) for 0,5 cycle
40% UT(60% dip in
UT) for 5 cycles
70% UT(30% dip in
UT) for 25 cycles
<5% UT(>95% dip
in UT) for 5 s
<5% UT(>95% dip
in UT) for 0,5 cycle
40% UT(60% dip in
UT) for 5 cycles
70% UT(30% dip in
UT) for 25 cycles
<5% UT(>95% dip
in UT) for 5 s
Mains power quality should be that of a
typical commercial or hospital
environment. If the user of the Rooti RX
requires continued operation during
power mains interruptions, it is
recommended that the Rooti RX be
powered from an uninterruptible power
supply or a battery.
3 A/m
3 A/m
The Rooti RX power frequency
magnetic fields should be at levels
characteristic of a typical location in a
typical commercial or hospital
environment.
Power frequency
(50, 60 Hz)
magnetic field
IEC 61000-4-8
NOTE UT is the a.c. mains voltage prior to application of the test level.
16
Electromagnetic environment-guidance
Portable and mobile RF communications
equipment should be used no closer to any part
of the Rooti RX including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency of
the transmitter.
NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically
with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site
survey should be considered. If the measured field strength in the location in which the Rooti RX is used
exceeds the applicable RF compliance level above, the Rooti RX should be observed to verify normal operation.
If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating
the Rooti RX.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distance between
portable and mobile RF communications equipment and the Rooti RX
The Rooti RX is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the Rooti RX can help prevent electromagnetic interference by maintaining
a minimum distance between portable and mobile RF communications equipment (transmitters) and the Rooti RX
as recommended below, according to the maximum output power of the communications equipment.
Rated maximum
output power of
transmitter
Separation distance according to frequency of transmitter
150 kHz to 80 MHz
d =1,2√P
80 MHz to 800 MHz
d =1,2√P
800 MHz to 2.5 GHz
d =2,3√P
0,01
0,12
0,12
0,23
0,1
0,38
0,38
0,73
1,2
1,2
2,3
10
3,8
3,8
7,3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where p is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Format                          : application/pdf
Title                           : InstructionManual_revJ_20160307
Metadata Date                   : 2016:03:14 11:26:32+08:00
Modify Date                     : 2016:03:14 11:26:32+08:00
Create Date                     : 2016:03:14 11:26:32+09:00
Creator Tool                    : Adobe Illustrator CS6 (Windows)
Thumbnail Width                 : 256
Thumbnail Height                : 168
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 13110 bytes, use -b option to extract)
Instance ID                     : uuid:ced7258b-2402-40fc-b7ca-c8a1b912b622
Document ID                     : xmp.did:7D3A478894E9E511AE7DD8276507142E
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:20838afc-2f96-438b-a105-207480157814
Derived From Document ID        : xmp.did:5432995669A9E511A524F3495AB9FF66
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:5432995669A9E511A524F3495AB9FF66, xmp.iid:7D3A478894E9E511AE7DD8276507142E
History When                    : 2015:12:23 19:35:59+08:00, 2016:03:14 11:26:25+08:00
History Software Agent          : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows)
History Changed                 : /, /
Manifest Link Form              : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference
Manifest Reference File Path    : C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\InstructionManual\3_6b.png, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\ios\ios\Icon-60@3x.png, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\ios\ios\Icon-60@3x.png, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\screenshot\IMG_5081.PNG, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\screenshot\IMG_5083.PNG, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\screenshot\IMG_5085.PNG, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\screenshot\IMG_5081.PNG, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\screenshot\IMG_5090.PNG, C:\Users\user\Documents\Projects_Haowei\Rooti\SleepRx\Miscellanious\QSG\screenshot\IMG_5080.PNG
Startup Profile                 : Print
Has Visible Overprint           : False
Has Visible Transparency        : True
N Pages                         : 1
Max Page Size W                 : 200.000195
Max Page Size H                 : 150.001180
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, Arial-ItalicMT, Gautami-Bold, MyriadPro-Regular, MyriadPro-It, Tahoma, Tahoma-Bold, AdobeMingStd-Light
Font Family                     : Arial, Arial, Gautami, Myriad Pro, Myriad Pro, Tahoma, Tahoma, Adobe 明體 Std
Font Face                       : Regular, Italic, Bold, Regular, Italic, Regular, Bold, L
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type
Font Version                    : Version 5.21, Version 5.21, Version 5.90, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 5.21, Version 5.21, Version 6.007;PS 6.001;hotconv 1.0.67;makeotf.lib2.5.33168
Font Composite                  : False, False, False, False, False, False, False, False
Font File Name                  : arial.ttf, ariali.ttf, gautamib.ttf, MyriadPro-Regular.otf, MyriadPro-It.otf, TAHOMA.TTF, TAHOMABD.TTF, AdobeMingStd-Light.otf
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE Cool Gray 3 U
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Colorants L       : 79.607796
Swatch Groups Colorants A       : 0
Swatch Groups Colorants B       : 0
Swatch Groups Group Name        : Brights
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0
Swatch Groups Colorants Mode    : RGB
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Red     : 127
Swatch Groups Colorants Green   : 63
Swatch Groups Colorants Blue    : 151
Producer                        : Adobe PDF library 10.01
Page Count                      : 10
Creator                         : Adobe Illustrator CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ACVP-M2-2016

Navigation menu