Rosemount 753S Remote Monitoring Device User Manual HART Transmitter Rev AA PDS

Rosemount Inc Remote Monitoring Device HART Transmitter Rev AA PDS

Manual

Download: Rosemount 753S Remote Monitoring Device User Manual HART Transmitter  Rev AA PDS
Mirror Download [FCC.gov]Rosemount 753S Remote Monitoring Device User Manual HART Transmitter  Rev AA PDS
Document ID521056
Application ID1Q1G3WAh2JT+Z4/A6XtRvw==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize60.75kB (759342 bits)
Date Submitted2005-03-07 00:00:00
Date Available2005-03-07 00:00:00
Creation Date2005-02-17 21:19:35
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2005-02-17 15:23:38
Document TitleHART Transmitter_ Rev AA PDS.fm
Document CreatorPScript5.dll Version 5.2
Document Author: carljoh

Preliminary Copy
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Rosemount Wireless HART Network
Transmitter
• Truly wireless transmitter for monitoring
applications
• Improved asset management with advanced
HART diagnostics
• Mitigate need for wireless surveys with Self
Organizing Network technology
• Integrate data into DCS/PC/AMS host
systems
Content
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
Configuration Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
www.rosemount.com
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Scalable and Flexible Device Networks
Scalable
• Automatically recognize new device installation
• Tiered measurement offering
• Wireless solution maintains data accuracy
Flexible
• Integrates with pressure, temperature, level, and flow devices
• HART/analog and discrete inputs
• Truly wireless solution for easy installation
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Selection Guide
ORDERING OPTIONS
Remote Mount
REMOTE MOUNT WITH REMOTE
POWER SUPPLY
ENERGY EFFICIENT REMOTE
MOUNT WITH LINE POWER
24VDC
Wireless Housing with Integrated Pressure Transmitter
INTEGRATED PRESSURE TRANSMITTER AND
REMOTE POWER SUPPLY
ENERGY EFFICIENT INTEGRATED
PRESSURE TRANSMITTER
24 VDC
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Specifications
PERFORMANCE SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Vibration Effect
Electrical Connections
Less than +/- 0.1% of URL when tested per the requirements of
IEC 60770-1 field or pipeline with high vibration level (10-60 Hz
0.211mm displacement peak amplitude / 60-2000 Hz 3g).
½ - 14 NPT conduit.
Housing style codes 1J, 1K, 1L, 2J
Less than +/- 0.1% of URL when tested per the requirements of
IEC60770-1 field with general application or pipeline with low
vibration level (10-60 Hz 0.15mm displacement peak amplitude /
60-500 Hz 2g).
Polyurethane
Electromagnetic Compatibility (EMC)
Meets all relevant requirements of IEC/EN 61326 and NAMUR
NE-21.
FUNCTIONAL SPECIFICATIONS
Power Supply
Paint
Cover O-rings
Buna-N
Assembly Configurations
Remote mount with remote power supply
Remote mount
Wireless housing with integrated pressure transmitter
and remote power supply
Wireless housing with integrated pressure transmitter
External power supply:
• Rosemount Remote Power Supply with solar panel and
battery
Pmax = 1.5W
Amp = 1.2
Voltage at Pmax = 16.5V
• 6 to 28 Vdc with no load
24VDC
Temperature Limits
Ambient
-4 to 140 °F (-20 to 60 °C)
Storage
-40 to 185 °F (-40 to 85 °C)
Humidity Limits
0-100% relative humidity
Turn-On Time
Performance within specifications less than 2.0 seconds after
power is applied to the transmitter or as determined by the
measurement transmitter (whichever is greater).
Vibration
Suitable for 60-2000 Hz 2g as specified in IEC 60770-1
Power Management
Update intervals from once per minute to once per hour.
24 VDC
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Product Certifications
Approved Manufacturing Locations
Rosemount Inc. — Chanhassen, Minnesota USA
FCC Compliance
This product is in compliance with FCC regulations.
FCC ID: LW2753S
IC ID: 2731-753S
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions:
• this device may not cause harmful interference, and
• this device must accept any interference received, including
interference that may cause undesired operation
Changes or modifications not expressly approved by
Rosemount, Inc. could void your authority to operate
the equipment.
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Dimensional Drawings
Transmission Antenna
* R - SMA CONNECTOR
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Assembly
* R - SMA CONNECTOR
Remote Power Supply
* R - SMA CONNECTOR
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Configuration Data Sheet
Configuration Data Sheet
Customer: _____________________________________________
P.O. No.:_______________________________________________
Model No.: _____________________________________________
Line Item: ______________________________________________
Input Output Information
Type of Measurement Variable Input:
□ HART (multi-drop mode)
□1
753R / iTraX Information
Device Tag Name:
I_I_I_I_I_I_I_I_I_I_I_I_I_I_I_I_I_I_I_I_I
(20 characters maximum)
Measurement Variables to Transmit:
Read/Transmit Interval:
Event Expiration Time:
Device Startup Time:
Power Mode:
□ PV
□ SV
□ TV
□ QV
□ Read and transmit once per minute
□ Read and transmit once every 5 minutes
□ Read and transmit once every 15 minutes
□ Read and transmit once every 30 minutes
□ Read and transmit once per hour
_______ minutes (default 30 minutes)
_______ seconds (default 2 seconds)
□ Power Save
□ Always On
Button Configuration
Mode:
□ Enable
□ Disable
Application Information (If Applicable)
Location (city, state, country):
Process Material Name:
Material Phase:
_____________________________________________
_____________________________________________
□ Liquid
□ Gas
□ Solid
□ Steam
Expected Date of Installation: _________
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Product Data Sheet
00813-0100-XXXX, Rev AA
February 2005
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.
All other marks are the property of their respective owners.
Emerson Process Management
Rosemount Division
8200 Market Boulevard
Chanhassen, MN 55317 USA
T (U.S.) 1-800-999-9307
T (International) (952) 906-8888
F (952) 949-7001
Rosemount Temperature GmbH
Frankenstrasse 21
63791 Karlstein
Germany
T 49 (6188) 992 0
F 49 (6188) 992 112
www.rosemount.com
¢00813-XXXX-XXXXm¤
© 2005 Rosemount Inc. All rights reserved.
Emerson Process Management Asia
Pacific Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947
AP.RMT-Specialist@emersonprocess.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2005:02:17 21:19:35Z
Modify Date                     : 2005:02:17 15:23:38-06:00
Page Count                      : 10
Creation Date                   : 2005:02:17 21:19:35Z
Mod Date                        : 2005:02:17 15:23:38-06:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : carljoh
Metadata Date                   : 2005:02:17 15:23:38-06:00
Creator                         : carljoh
Title                           : HART Transmitter_ Rev AA PDS.fm
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LW2753S

Navigation menu