Rosemount 775-01 Wireless HART Industrial Process Management Product User Manual Publication1 pub

Rosemount Inc Wireless HART Industrial Process Management Product Publication1 pub

User manual

Reference Manual 00809-0100-0775, Rev AA March 2009 Smart Wireless THUM™ Adapter
Reference Manual 00809-0100-0775, Rev AA March 2009 Smart Wireless THUM™ Adapter Smart Wireless THUM Adapter Smart Wireless THUM Adapter Hardware Revision      1 HART® Device Revision     1 Field Communicator Field Device Revision         Dev v2.5 DD v4 Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure to thoroughly understand the contents before installing, using, or maintaining this product.  The United States has two toll-free assistance numbers and one international number.  Customer Central 1-800-999-9307 (7:00 a.m. to 7:00 P.M. CST)  National Response Center 1-800-654-7768 (24 hours a day) Equipment service needs  International 1-(952) 906-8888 NOTICE CAUTION The products described in this document are NOT designed for nuclear-qualified applications.  Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate readings.  For information on Rosemount nuclear-qualified products, contact a Emerson Process Management Sales Representative. The Smart Wireless THUM Adapter may be protected by one or more U.S. Patents pending.  Other foreign patents pending.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Explosions could result in death or serious injury: Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the approvals section of the THUM reference manual for any restrictions associated with a safe installation.   • Before connecting a Field Communicator in an explosive atmosphere, ensure the   instruments are installed in accordance with intrinsically safe or non-incendive   field wiring practices.              Process leaks may cause harm or result in death.   • Install and tighten process connectors before applying pressure.              Electrical shock can result in death or serious injury.   • Avoid contact with the leads and terminals. High voltage that may be present on   leads can cause electrical shock. NOTICE NOTICE NOTICE The THUM and all other wireless devices should be installed only after the Smart Wireless Gateway has been installed and is functioning properly. Wireless devices should also be powered up in order of proximity from the Gateway, beginning with the closest. This will result in a simpler and faster network installation.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter WARNING Failure to follow these installation guidelines could result in death or serious injury.   •Make sure only qualified personnel perform the installation.  Explosions could result in death or serious injury.   • Before connecting a 375 Field Communicator in an explosive atmosphere, make   sure the instruments are installed in accordance with intrinsically safe or   non-incendive field wiring practices.   • Verify that the operating atmosphere of the transmitter is consistent with the   appropriate hazardous locations certifications.  Electrical shock could cause death or serious injury.   • Use extreme caution when making contact with the leads and terminals. Section 1  Overview Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-2 Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-3 Return of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-4 SAFETY  MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol ( ). Please refer to the following safety messages before performing an operation preceded by this symbol. Warnings
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Overview Manual This manual is designed to assist in the installation, operation, and maintenance of Smart Wireless THUM Adapter. Section 1: Overview   • Manual and Transmitter Overview  • Considerations   • Return of Materials Section 2: Configuration   • Device Sensor Configuration   • Device Network Configuration Section 3: Mounting   • Mount the Sensor   • Sensor Assembly/Leads  • Grounding Section 4: Commissioning   • Network Status  • Verify Operation Section 5: Operation and Maintenance Appendix A: Specifications and Reference Data • Specifications • Dimensional drawings • Ordering Information Appendix B: Approvals • Product Certifications • Installation Drawings  Features of the Smart Wireless THUM Adapter include: • An installation-ready solution that provides a variety of mounting options, and transmitter configurations • Flexibility to meet your most demanding applications • Wireless output with >99% data reliability delivers rich HART data, protected by industry leading security • Works with any 2 or 4 wire HART 5.0 or new Device • Does not affect the approval of the sub-device Transmitter
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Considerations General The Smart Wireless THUM Adapter is connected to a HART sub-device.  With simple HART configu-ration, the THUM transmits the HART information from the sub-device unto the WirelessHART net-work.     The THUM can be commissioned before or after installation. It may be useful to commission it on the bench, before installation, to ensure proper operation and to become familiar with its functionality. When applicable, make sure the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices. The device will be powered whenever THUM is  connected to a powered loop.    Location  When choosing an installation location and position, take into account the need for access to the transmitter. For best performance, the antenna should be vertical with some space between objects in a parallel metal plane such as a pipe or metal framework, as the pipes or framework may adversely affect the performance of the antenna.  THUM Power Options  The THUM has two power options; variable current, and fixed current mode.    Variable Current  Variable current mode is the mode that the THUM should be in if the current on the 4-20 mA loop can change between 4 to 20 mA.  The THUM will drop 2.25 volts at 2.5 mA and 1 volt at 25 mA.  The voltage drop is linear between these two points.  The THUM will operate  according to standard specifications under this mode.  Fixed Current  Fixed current mode can only be used when the current of the loop will never fall below 20 mA.  The THUM will always drop 1 volt across the loop. If the current of the loop falls below 20 mA the THUM, and the rest of the wireless network may not function properly.  This symbol represents protective earth grounding. Commissioning Mechanical Electrical
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter RETURN OF  MATERIALS Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications. Temperature Effects The transmitter will operate within specifications for ambient temperatures between –40 and 185 °F (–40 and 85 °C).            To expedite the return process in North America, call the Emerson Process Management National Response Center toll-free at 800-654-7768. This center, available 24 hours a day, will assist you with any needed information or materials.  The center will ask for the following information:   • Product model   • Serial numbers   • The last process material to which the product was exposed The center will provide   • A Return Material Authorization (RMA) number   • Instructions and procedures that are necessary to return goods that   were exposed to hazardous substances  For other locations outside North America, please contact an Emerson Process Management sales representative for further instructions.   NOTE If the device has been exposed to a hazardous substance, a Material Safety Data Sheet (MSDS) must be included with the returned materials. An MSDS is required by law to be available to people exposed to specific hazardous substances. Environmental
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter WARNING Failure to follow these installation guidelines could result in death or serious injury.   •Make sure only qualified personnel perform the installation.  Explosions could result in death or serious injury.   • Before connecting a 375 Field Communicator in an explosive atmosphere, make   sure the instruments are installed in accordance with intrinsically safe or   non-incendive field wiring practices.   • Verify that the operating atmosphere of the transmitter is consistent with the   appropriate hazardous locations certifications.  Electrical shock could cause death or serious injury.   • Use extreme caution when making contact with the leads and terminals.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference, this device must accept any interference received, including interference that may cause undesired operation.  This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Section 2  Configuration Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Device Sensor Configuration . . . . . . . . . . . . . . . ... . . . . . . page 2-2 Device Network Configuration . . . . . . . . . . . . . .. . . . . . . . page 2-2 SAFETY  MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol ( ). Please refer to the following safety messages before performing an operation preceded by this symbol. Warnings
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Connections  The THUM is compatible with a number of sub-devices.  See section 3 for details on wiring the THUM to different types of sub-devices.    The THUM will receive any HART communication from a handheld Field Communicator, or AMS®.  In order for the THUM to receive HART communication the sub-device must be powered.  When us-ing a Field communicator polling must be turned on, the default HART address for the THUM is ad-dress 15.  When using a Field Communicator, any configuration changes must be sent to the transmit-ter using the Send key (F2). AMS configuration changes are implemented when the Apply button is clicked.   AMS® Wireless Configurator  AMS is capable of connecting to devices directly, using a HART modem, or with the Gateway. When configuring on the bench with a HART modem, double click the device icon, then choose the Config-ure/Setup tab (or right click and select Configure/Setup). Configure the device settings using the Direct Connection menu. When configuring with the Gateway, double click the device icon then choose the Configure/Setup tab (or right click and select Configure/Setup). Configure the device settings using the Wireless Connection menu. To check or change sensor configuration using a 375 Field Communicator, enter the following Fast Key Sequence: 2, 1, 3.  To communicate with the Gateway, and ultimately the Information System, the transmitter must be configured to communicate with the wireless network. Using a Field Communicator or AMS, enter the Network ID and Join Key so they match the Network ID and Join Key of the Gateway and the other devices in the network. If the Network ID and Join Key are not identical, the transmitter will not com-municate with the network. The Network ID and Join Key may be obtained from the Gateway on the Setup>Network>Settings page on the web server. Using a 375 Field Communicator, the Network ID can be configured by entering the Fast Key Sequence: 2, 2, 1, 1. The Join Key can also be configured using a 375 Field Communicator with the Fast Key Sequence: 2, 2, 1, 2.   The final device network configuration piece is the Update Rate.  There are three update rates for the THUM.  Each Update Rate can be configured independently of the other two.  One of the Updates is for THUM specific information such as THUM temperature and communication status.  The other two Update Rates are for sub-device information.  The information that is sent for the sub-device and the frequency that it is sent can all be changed at commissioning or at any other time.  At default the Up-date Rate for all three Updates is 1 minute.  The Updates can be changed using AMS or a 375 Field Communicator. THUM Configuration DEVICE NETWORK CONFIGURATION
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter WARNING Failure to follow these installation guidelines could result in death or serious injury.   •Make sure only qualified personnel perform the installation.  Explosions could result in death or serious injury.   • Before connecting a 375 Field Communicator in an explosive atmosphere, make   sure the instruments are installed in accordance with intrinsically safe or   non-incendive field wiring practices.   • Verify that the operating atmosphere of the transmitter is consistent with the   appropriate hazardous locations certifications.  Electrical shock could cause death or serious injury.   • Use extreme caution when making contact with the leads and terminals.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference, this device must accept any interference received, including interference that may cause undesired operation.  This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Section 3  Mounting Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-2 Direct Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-2 Remote Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-4 Ground the Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . ..page 3-5 SAFETY  MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol ( ). Please refer to the following safety messages before performing an operation preceded by this symbol. Warnings
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Mounting  The THUM can be installed in one of two configurations: Direct Mount, where the THUM is  connected directly to the conduit entry of the sub-device, or Remote Mount, where the THUM is mounted separate from the sub-device housing, then connected to the sub-device via conduit. Choose the installation sequence that corresponds to the mounting configuration.  1. Install the HART® device according to standard installation practices, being sure to use thread sealant on all connections. 2. Using the threaded conduit entry attach the THUM to the HART® device making sure to position the THUM in a vertical position, using a 90-degree elbow, if necessary. 3. Connect the THUM to the HART® sub-device using the wiring diagrams below. See Figures 1, 2, 3, and 4 on the following pages. 4. Close the housing cover on the HART® device, so that metal touches metal, and tighten to safety specifications. Please note that the unit may be damaged by over tightening the cover.  NOTE The THUM includes two euro splice connectors. The first is a two compartment splice. The second is a three compartment splice which contains a 250 Ohm resistor, to be used if there is not 250 Ohms of resistance in the loop.  1. Install the HART® device according to standard installation practices, being sure to use thread sealant on all connections. 2. Mount the THUM in a location for good wireless network communication.  Make sure to mount the THUM in a vertical position. 3. Using standard practices connect the THUM wires to the sub-device. 4. Wire the THUM to the HART® sub-device using the wiring diagrams below. See Figures 1, 2, 3, and 4 on the following pages. 5. Close the housing cover on the HART® device, so that metal touches metal, and tighten to safety specifications. Please note that the unit may be damaged by over tightening the cover.  NOTE The THUM includes two euro splice connectors. The first is a two compartment splice. The second is a three compartment splice which contains a 250 Ohm resistor, to be used if there is not 250 Ohms of resistance in the loop. Direct Mount Remount Mount
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Wiring  Figure 1. 2 Wire Sub-Device Plus THUM Wiring Diagram                  NOTE: In order for the THUM to function properly there must be 250 Ohms resistance in the loop. If the 4–20 mA loop does not have 250 Ohms resistance, wire a 250 Ohm resistor as shown in Figure 2.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Wiring  Figure 2. 2 Wire Sub-Device Plus THUM Wiring Diagram with 250 Ohm Resistor                 NOTE: In order for the THUM to function properly there must be 250 Ohms resistance in the loop. If the 4–20 mA loop does not have 250 Ohms resistance, wire a 250 Ohm resistor as shown in Figure 2.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Wiring  Figure 3. 4-Wire Sub-Device with Passive 4–20 mA LOOP Plus THUM Wiring Diagram  NOTE: In order for the THUM to function properly there must be 250 Ohms resistance in the loop. If the 4–20 mA loop does not have 250 Ohms resistance, wire a 250 Ohm resistor as shown in Figure 4.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Wiring  Figure 4. 4-Wire Sub-Device with Passive 4–20 mA LOOP Plus THUM Wiring Diagram with 250 Ohm resistor  NOTE: In order for the THUM to function properly there must be 250 Ohms resistance in the loop. If the 4–20 mA loop does not have 250 Ohms resistance, wire a 250 Ohm resistor as shown in Figure 4.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Wiring  Figure 5. 4-Wire Sub-Device with Active 4–20 mA LOOP Plus THUM Wiring Diagram  NOTE: In order for the THUM to function properly there must be 250 Ohms resistance in the loop. If the 4–20 mA loop does not have 250 Ohms resistance, wire a 250 Ohm resistor as shown in Figure 6.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Wiring  Figure 6. 4-Wire Sub-Device with Active 4–20 mA LOOP Plus THUM Wiring Diagram with 250 Ohm resistance  NOTE: In order for the THUM to function properly there must be 250 Ohms resistance in the loop. If the 4–20 mA loop does not have 250 Ohms resistance, wire a 250 Ohm resistor as shown in Figure 6.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Wiring  Figure 7. 4-Wire Sub-Device with no 4–20 mA LOOP Plus THUM Wiring Diagram   NOTE: In order for the THUM to function properly there must be 250 Ohms resistance in the loop. If the 4–20 mA loop does not have 250 Ohms resistance, wire a 250 Ohm resistor as shown in Figure 7.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter WARNING Failure to follow these installation guidelines could result in death or serious injury.   •Make sure only qualified personnel perform the installation.  Explosions could result in death or serious injury.   • Before connecting a 375 Field Communicator in an explosive atmosphere, make   sure the instruments are installed in accordance with intrinsically safe or   non-incendive field wiring practices.   • Verify that the operating atmosphere of the transmitter is consistent with the   appropriate hazardous locations certifications.  Electrical shock could cause death or serious injury.   • Use extreme caution when making contact with the leads and terminals.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference, this device must accept any interference received, including interference that may cause undesired operation.  This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Section 4  Commissioning Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 Verify Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-2 SAFETY  MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol ( ). Please refer to the following safety messages before performing an operation preceded by this symbol. Warnings
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Operation can be verified in two locations,  using the 375 Field Communicator, or at the Gateway via the Wireless Gateway’s integrated web server.  375 Field Communicator  To verify device operation using a HART Field Communicator, a 648 DD is required.        Smart Wireless Gateway  To verify device operation using the 1420 Wireless Gateway’s integrated web server, navigate to the Explorer>Status page. This page will show whether the device has joined the network and if it is communicating properly.  If the THUM was configured with the Network ID and Join Key and sufficient time for network poll-ing has passed, the transmitter will be connected to the network. To verify connectivity, open the 1420 Wireless Gateway’s integral web interface and navigate to the Explorer>Status page. Verify Operations
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter This page will display the transmitter’s tag, PV, SV, TV, QV, Last Update, Update Rate, Battery Volt-age, and Status. A green status indicator means that the device is working properly. A red indicator means that there is a problem with either the device or its communication path. For more detail on a specific device, click on the tag name.  Troubleshooting    The most common cause of incorrect operation is the Network ID and Join Key. The Network ID and Join Key in the device must match that of the Gateway. The Network ID and Join Key may be obtained from the Gateway on the Setup>Network>Settings page on the web server.
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter WARNING Failure to follow these installation guidelines could result in death or serious injury.   •Make sure only qualified personnel perform the installation.  Explosions could result in death or serious injury.   • Before connecting a 375 Field Communicator in an explosive atmosphere, make   sure the instruments are installed in accordance with intrinsically safe or   non-incendive field wiring practices.   • Verify that the operating atmosphere of the transmitter is consistent with the   appropriate hazardous locations certifications.  Electrical shock could cause death or serious injury.   • Use extreme caution when making contact with the leads and terminals.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference, this device must accept any interference received, including interference that may cause undesired operation.  This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Section 5  Operations and Maintenance Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1 LCD Screen Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-2  SAFETY  MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol ( ). Please refer to the following safety messages before performing an operation preceded by this symbol. Warnings
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Due to the power scavenging of the THUM different capabilities will be available at different times after startup.  Immediately after startup configuration of the THUM is available.  This includes all net-work settings including Network ID and Join Key, and Update Rate.  The THUM will not start to join the network until the radio turns completely on.  This will not happen until up to 3 minutes after startup depending on the current of the loop.      To determine if the THUM has joined the network, go to the Explorer page on the Gateway and look for the THUM tag number as shown below.     Startup Sequence Diagnostic
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Appendix A  Specifications and Reference Data Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-3 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-4 Specifications Functional Specifications Input Any 2- or 4-wire HART 5.0 powered device.  Output WirelessHART.  Humidity Limits 0–100% relative humidity  Burst Rate User selectable, 8 sec. to 60 min.  Electrical Connections The THUM™ is connected into a powered 4–20 mA loop, powering itself by scavenging power. The THUM causes a voltage drop across the loop. The drop is linear from 2.25 volts at 3.5 mA to 1.2 volts at 25 mA, but does not effect the 4–20mA signal on the loop. Under fault conditions, the maximum voltage drop is 2.5 volts.  Power Supply Minimum load on loop 250 Ohms to maintain normal operating functions of the sub-device, the power in the loop must have at least a 2.5 V margin at a 250 Ohm load.  HART Communicator Connections Utilize sub-device HART connections.  Materials of Construction Enclosure Housing - Low-copper aluminum Paint - Polyurethane  Antenna Poly butadine terephthalate (PBT)/Polycarbonate (PC) integrated omnidirectional antenna  Weight .65 lbs. (.29 kg)  Enclosure Ratings Housing option code D is NEMA 4X, and IP66. Physical  Specifications
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter ElectroMagnetic Compatibility (EMC) All Models: Meets all relevant requirements of EN61326-1 (2006) .  Vibration Effect Output unaffected when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz 0.21mm displacement peak amplitude / 60-2000 Hz 3g). Output unaffected when tested per the requirements of IEC60770-1 field with general application or pipeline with low vibration level (10-60 Hz 0.15mm displacement peak amplitude / 60-500 Hz 2g).   Temperature Limits         Output Specifications The THUM™ allows WirelessHART™ communication between the HART device it is connected to and the Smart Wireless Gateway. Performance Specifications
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter DIMENSIONAL DRAWINGS
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Ordering Information
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter Appendix B  Product Certifications Approved Manufacturing Locations . . . . . . . . . . . . . . . . . page B-1 Telecommunication Compliance . . . . . . . . . . . . . . . . . . . . page B-1 European Union Directive Information . . . . . . . . . . . . . . . page B-1 Ordinary Location Certification for FM . . . . . . . . . . . . . . . page B-2 Hazardous Locations Certificates . . . . . . . . . . . . . . . . . . . page B-2 Approved  Manufacturing Locations Rosemount Inc. – Chanhassen, Minnesota, USA       All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.   This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired opera-tion.  This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons.  The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative.  ATEX Directive (94/9/EC)   Emerson Process Management complies with the ATEX Directive.  Electro Magnetic Compatibility (EMC) (2004/108/EC)  Emerson Process Management complies with the EMC Directive  Radio and Telecommunications Terminal Equipment Directive (R&TTE) (1999/5/EC)   Emerson Process Management complies with the R&TTE Directive.   As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Telecommunication Compliance FCC and IC European Union Directive  Information Ordinary Location Certification for FM
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter North American Certifications  Factory Mutual (FM) Approvals  I5 FM Intrinsic Safety and Non-incendive Intrinsically Safe for Class I/II/III, Division 1, Groups A, B, C, D,E, F, and G. Zone Marking: Class I, Zone 0, AEx ia llC Temperature Codes T4 (Tamb = -50 to 70° C) Non-incendive for Class I, Division 2, Groups A, B, C, and D. Intrinsically safe and non-incendive when installed according to Rosemount Drawing 00775-XXXX. Enclosure Type 4X/IP66 Warning: The antenna does not meet the surface resistivity requirements and, to avoid electrostatic charging, it must only be cleaned with a damp cloth.   CSA - Canadian Standards Association  I6 CSA Intrinsic Safety Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. Intrinsically safe and non-incendive when installed according to Rosemount Drawing 00775-XXXX Warning: The antenna does not meet the surface resistivity requirements and, to avoid electrostatic charging, it must only be cleaned with a damp cloth.  European Certifications  I1 ATEX Intrinsic Safety Certificate No.: See Certificate II 1G Ex ia IIC T5 (Ta = -50 °C to 40 °C) Ex ia IIC T4 (Ta = -50 °C to 70 °C) IP66             Special Conditions of Safe Use (X) The antenna does not meet the surface resistivity requirements and, to avoid electrostatic charging, it must only be cleaned with a damp cloth. Hazardous  Locations Certificates
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter  IECEx Certifications  I7 IECEx Intrinsic Safety Certificate No.: See Certificate Ex ia IIC T5 (Tamb = -50 °C to 40 °C) Ex ia IIC T4 (Tamb = -50 °C to 70 °C) IP66            Special Conditions of Safe Use (X) The antenna does not meet the surface resistivity requirements and, to avoid electrostatic charging, it must only be cleaned with a damp cloth. Hazardous  Locations Certificates
Reference Manual 00809-0100-0775, Rev AA March 2009  Smart Wireless THUM Adapter

Navigation menu