Rosslare AYX6255 CSN SELECT Smart Card Readers User Manual A4 1 page

Rosslare Enterprises Ltd CSN SELECT Smart Card Readers A4 1 page

Contents

User Manual

Download: Rosslare AYX6255 CSN SELECT Smart Card Readers User Manual A4 1 page
Mirror Download [FCC.gov]Rosslare AYX6255 CSN SELECT Smart Card Readers User Manual A4 1 page
Document ID3252210
Application IDvu85PSLpeWcwznehYWu2/Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize17.84kB (223041 bits)
Date Submitted2017-01-09 00:00:00
Date Available2017-01-09 00:00:00
Creation Date2016-04-28 09:15:58
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2016-04-28 09:15:59
Document TitleA4 1-page
Document CreatorAcrobat PDFMaker 10.0 for Word
Document Author: Sam Goldberg

AY-x6255 Family
CSN SELECT Smart Card Readers
Installation and User Manual
1. Introduction
The AY-x6255 is a family of multi-format contactless smart card
readers for use in access control system solutions.
1.1
Box Content
Before beginning, verify that all of the following is in the box. If
anything is missing, please report the discrepancy to your nearest
Rosslare office.
CSN SELECT readers support reading from the secure memory of the
following credential technologies:

MIFARE Ultralight / Ultralight C

One AY-x6255 unit

MIFARE Classic


MIFARE Plus S / Plus X
Installation kit – Includes two wall plugs, two mounting screws,
security Torx screw, and security Torx screw tool

MIFARE DESFire EV1

Installation and operating instructions

ISO 14443A

ISO 14443B

ISO 15693

iClass

ISO 18092 (NFCIP-1)

FeliCa
AY-K6255
AY-L6255
AY-H6255
AY-M6255
2. Technical Specifications
2.1
Electrical Characteristics
2.2
Environmental Characteristics
Power Supply Type
Linear (recommended)
Operating Temp. Range
-25°C to 65°C (-13°F to 149°F)
Operating Voltage Range
8 to 16 VDC
Operating Humidity Range
0 to 95% (non-condensing)
Current @ 12 V
Standby: 100 mA
Maximum: 120 mA
Outdoor Usage
Read Range*
MIFARE Classic EV1: 40 to 45 mm (1.5 to 1.8 in.)
MIFARE Plus: 30 mm (1.2 in.)
MIFARE DESFire EV1: 30 mm (1.2 in.)
Weather-resistant, UV-resistant, meets IP65,
epoxy-potted, suitable for indoor and outdoor
use
LED Control Input 1**
Green LED control, TTL
LED Control Input 2**
Red LED control, TTL
Auxiliary Input**
Buzzer control, TTL
Auxiliary Output**
Tamper output (open collector, active low, max.
sink current 30 mA)
Maximum Cable Distance
to Controller
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1200 m (4,000 ft) with 2x2 18AWG twisted shielded cable
2.3
Physical Characteristics
Dimensions
(H x W x D)
AY-K6255: 80.5 x 40.5 x 14.7 mm
(3.2 x 1.6 x 0.6 in.)
AY-L6255: 144.9 x 42.9 x 22.1 mm
(5.7 x 1.7 x 0.9 in.)
AY-H6255: 110.7 x 75.0 x 17.1 mm
(4.4 x 3.0 x 0.7 in.)
AY-M6255: 89.5 x 88.9 x 16.8 mm
(3.5 x 3.5 x 0.7 in.)
Weight
* Measured using a Rosslare MIFARE card cards. Range also depends on
electrical environment and proximity to metal.
AY-K6255: 77 g (2.7 oz)
AY-L6255: 126 g (4.4 oz)
AY-H6255: 163 g (5.7 oz)
** Standard configuration. Custom configurations are available.
AY-M6255: 145 g (5.1 oz.)
3. Wiring Instructions
The units are supplied with a 10-conductor 18” (46-cm) pigtail or with
10 terminal blocks.
Table 1: AY-x6255 Wiring
Wire Color
To connect a pigtail reader to the controller:
1. Prepare the reader cable by cutting its jacket back 3.2 cm (1¼”)
and strip the insulation from the wires 1.3 cm (½").
2. Prepare the controller cable by cutting its jacket back 3.2 cm (1¼")
and strip the insulation from the wires 1.3 cm (½").
3. Splice the reader’s pigtail wires to the corresponding controller
wires (as indicated in Table 1) and cover each joint with insulating
tape.
4. If the tamper output is being utilized, connect the purple wire to
the correct input on the controller.
The LED control may be configured by the factory to function
either as a LED control or as buzzer control. Currently, the auxiliary
input is used as buzzer control and LED Control 1 is used as the
green LED control.
Output
Red
Power
Black
Ground
Green
Data 0 / Data
White
Data 1 / Clock
Purple
Tamper Output
Orange
Green LED control
Brown
Red LED control
Yellow
Buzzer control / Auxiliary input
Blue
OSDP-RS-485-A*
Gray
OSDP-RS-485-B*
*H and M models only
• The individual wires from the reader are color coded according the
Wiegand standard.
5. Trim and cover all unused conductors.
• When using a separate power supply for the reader, this supply and
that of the controller must have a common ground.
• The reader’s cable shield wire should be preferably attached to an earth
ground, or a signal ground connection at the panel, or power supply
end of the cable.
4. OSDP Operation

The K and L models do not currently support OSDP function.
DIP Switch 1
This switch is used to select the reader output (Wiegand or OSDP):

Off = Wiegand

On = OSDP
CSN SELECT readers that support OSDP operation are compatible with
most OSDP commands. The reader address is set using DIP switches on
the back of the reader. Release the screw on the back of the reader to
remove the door to access the DIP switches.

DIP Switch 2
Figure 1 shows the DIP switch settings, which are described below.

DIP Switch 3
This switch is reserved for future use.
This switch is reserved for future use.
Figure 1: DIP Switch Settings

DIP Switches 4 to 8
These switches set the address of the reader for OSDP protocol.
DIP Switch 4 is MSB and DIP Switch 8 is LSB. The address is the DIP
switch state +1.
Examples:

All the DIP switches in Off position, state is = 0 => address = 1

All the DIP switches in On position, state is = 0x1F => address
= 0x20 = 32
DIP switches 4, 6, 8 in On position and 5, 7 in Off position, state is
= 0x15 => address = 0x16 = 22
Declaration of Conformity
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
AYMH6255: FCC ID = GCD-AYCX6X55
AYKL6255: FCC ID = GCD-AYX6255


This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:

This device may not cause harmful interference.

This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick
Links section on the ROSSLARE website at www.rosslaresecurity.com.
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
Contact Information
United States and Canada
China
Rosslare Security Products, Inc.
Southlake, TX, USA
Toll Free: +1-866-632-1101
Local:
+1-817-305-0006
Fax:
+1-817-305-0069
support.na@rosslaresecurity.com
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86-755-8610-6842
Fax: +86-755-8610-6101
support.cn@rosslaresecurity.com
Europe
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852-2795-5630
Fax: +852-2795-1508
support.apac@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Israel Ltd.
Rosh HaAyin, Israel
Tel: +972-3-938-6838
Fax: +972-3-938-6830
support.eu@rosslaresecurity.com
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824
sales.in@rosslaresecurity.com
Rosslare Latin America
Buenos Aires, Argentina
Tel: +54-11-4001-3104
support.la@rosslaresecurity.com
www.rosslaresecurity.com
0706-0960618+00
India
Latin America

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Modify Date                     : 2016:04:28 09:15:59+03:00
Create Date                     : 2016:04:28 09:15:58+03:00
Metadata Date                   : 2016:04:28 09:15:59+03:00
Creator Tool                    : Acrobat PDFMaker 10.0 for Word
Document ID                     : uuid:c7ef336c-4a95-4189-9f5a-f1c48e7202ee
Instance ID                     : uuid:e11349b8-d860-4596-a703-c354fcc600b4
Subject                         : 8
Format                          : application/pdf
Title                           : A4 1-page
Creator                         : Sam Goldberg
Producer                        : Adobe PDF Library 10.0
Source Modified                 : D:20160428061536
Company                         : SYO
Product 0020 Name               : Product Name
Page Layout                     : OneColumn
Page Count                      : 2
Author                          : Sam Goldberg
Product Name                    : Product Name
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GCD-AYX6255

Navigation menu