Rosslare MD-W11NGR Wireless access control door interface User Manual MD W11 Installation Manual
Rosslare Enterprises Ltd Wireless access control door interface MD W11 Installation Manual
Rosslare >
manual
Wireless Access Control Door Interface MD-W11 Installation Manual November 2010 Introduction Table of Contents 1. Introduction ...................................................................... 2 1.1 1.2 Overview .................................................................................... 2 Features...................................................................................... 3 2. Technical Specifications .................................................... 6 2.1 2.2 2.3 2.4 2.5 2.6 Electrical Characteristics ............................................................ 6 Environmental Characteristics ................................................... 7 Dimensions ................................................................................. 7 Supported Card Transmission Formats ...................................... 8 Supported Keypad Transmission Formats .................................. 8 Available models ....................................................................... 8 3. Installation and Wiring........................................................ 9 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 The Installation Kit ....................................................................... 9 General Installation Requirements ............................................. 9 Installing the MD-W11N Unit...................................................... 10 Wiring the MD-W11N Unit .......................................................... 11 Installing the MD-W11F Unit ...................................................... 14 Wiring the MD-W11F Unit .......................................................... 14 Installing the MD-W11BP Battery Pack ...................................... 16 Wiring the MD-W11BP Battery Pack .......................................... 16 Indications on the Near and Far Units ...................................... 17 Installer Recommendations ..................................................... 17 4. Enrollment ...................................................................... 18 4.1 4.2 Enrolling the Units ...................................................................... 18 Dipswitches .............................................................................. 18 4.2.1. Near and Far Unit Modes ................................................................. 20 5. Operational Information .................................................. 23 Appendix A. Limited Warranty .............................................. 24 Appendix B. Declaration of Conformity................................. 26 Appendix C. Technical Support ............................................ 27 Page 1 MD-W11 Installation Manual Introduction 1. Introduction 1.1 Overview Rosslare Enterprises Ltd.’s MD-W11 Wireless Access Control Door Interface, is a quick, inexpensive solution for connecting remote door devices, such as readers, locks, and REX Buttons to an access control unit. The MD-W11 Wireless Access Control Door Interface consists of two units per door, one located near the controller (the Near unit) and the other near the door (the Far unit). The Near unit is connected to a Rosslare door controller (e.g., AC-215, AC-225, or AC-525). The Far unit is connected to proximity card readers or keypads (e.g., AY-K12 and AY-Q64B). When a card is read or a code is keyed onto the keypad, the Far unit transmits the information to the Near unit. The Near unit, attached to the AC-225 or to another controller, determines whether or not to open the door. The controller then sends the message to the Near unit, which transmits it to the Far unit, and if authorized, the door is opened. Caution: Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Rosslare Ltd.) could void the user’s authority to operate the equipment. MD-W11 Installation Manual Page 2 Introduction 1.2 Features The MD-W11 Wireless Access Control Door Interface includes: • Bi-directional RF data communication • Supports PIN codes and card formats, such as Wiegand 26 bit, 32 bit, and PIN code 6 bit (see list of formats on page 8). • Lock and door relay commands • Tamper, door monitor, and REX messages between the controller and the interface unit • Rolling Code to increase security • Four different RF channels to prevent collisions • Built-in charger for up to 12VDC, 7Ah backup battery on the Far unit • Transfers proximity card information and LED control, reader tamper, lock relay commands, REX, and door monitor events between the coupled units. • Optional MD-W11BP battery pack housing with space for 12VDC/800mAh, sealed lead-acid battery. • Suitable for indoor use. • Available in 869 MHz (H) and 433.92 MHz (G) bands • The NEAR unit is powered from the controller's power supply. The FAR unit is powered by a local wall transformer. A built-in charger provides battery backup. The MD-W11 Wireless Access Control Door Interface is displayed in Figures 1 and 2. Page 3 MD-W11 Installation Manual Introduction Figure 1: MD-W11 Wireless Access Control Door Interface – Near & Far Unit Figure 2: MD-W11 Wireless Access Control Door Interface – G Near Unit (with external Antenna) MD-W11 Installation Manual Page 4 Introduction Figure 3: MD-W11 Wireless Access Control Door Interface – Battery Pack Page 5 MD-W11 Installation Manual Technical Specifications 2. 2.1 Technical Specifications Electrical Characteristics Input Voltage: Far Unit: Near Unit: 12-24 AC, 15-24V DC. 13.8V DC from the controller's power supply or wall adapter. Battery Charger: 12V sealed Lead-Acid, up to 7Ah (Far Unit) Input Current: Standby: 70mAh Max: 160mA Maximum Range: (With External Antenna) Open field: 300 meters (985 feet) Range depends on RF related environmental conditions. Response time: Up to 500ms with Rosslare’s AC-215 controller and reader. Response time depends on RF link quality, number of doors used as well as controller and reader response time. Output Relays: Far Unit: Near Unit: One (1) 5A Form C relay Two (2) 1A Form C relays Output Types: Far Unit: Near Unit: LED CTRL – open collector STAM, SPV, LBAT, AC, TMP – open collector Communications: Bi-directional RF, narrow band. Fast anticollision, rolling code protocol with data protection. Available in 4 bands (see Dipswitches, on page 18). MD-W11 Installation Manual Page 6 Technical Specifications 2.1 Electrical Characteristics Data Transfer: Reader formats (based on the card and keypad transmission formats listed below), Lock commands, REX, Door Monitor, LED control and reader tamper inputs. Supervisory & Alerts: Full supervision over the remote unit. Alert outputs at the Near unit for supervision failure, system tamper, reader tamper, low battery and power failure. 2.2 Environmental Characteristics Operating Environment: Indoor Use Operating Temperature: -10°C to 50°C (14°F to 122°F) Operating Humidity: 0 to 95% (Non Condensing) 2.3 Dimensions Near/Far Units HxWxD 13 x 8.7 x 3.2 cm 5.1 x 3.42 x 1.26 inch Battery Pack HxWxD 12.8 x 6.9 x 3.4 cm 5.04 x 2.72 x 1.34 inch Weight Near/Far Units Battery Pack with battery Page 7 155 g 5.5 oz 433 g 15.3 oz MD-W11 Installation Manual Technical Specifications 2.4 • • • • • • Supported Card Transmission Formats Wiegand 26 bit (default) Wiegand 26 bit with facility code output Wiegand 32 bit Wiegand 32 bit reverse output Wiegand 34 bit Wiegand 40 bit 2.5 Supported Keypad Transmission Formats 2.6 Available models • • • • • • • • • • • Single key, 6-bit Wiegand (Rosslare format, default) Single key, 6-bit Wiegand with Nibble + Parity bits Single key, 8-bit Wiegand, Nibble Complemented 4 keys binary, 26 bit Wiegand 1 to 5 keys, 26 bit Wiegand 6 keys BCD and parity bits, 26 bit Wiegand MD-W11NHR (869MHz) MD-W11FHR (869MHz) MD-W11NGR (433MHz) MD-W11FGR (433MHz) MD-W11BP MD-W11 Installation Manual Page 8 Installation and Wiring 3. Installation and Wiring The NEAR and FAR units of the MD-W11 are installed and wired as explained in this chapter. 3.1 The Installation Kit The installation kit of the MD-W11 interface includes: • MD-W11N NEAR Unit: The Near unit sends the Controller the Proximity card ID or Keypad code as though it were a local reader. Following controller code/ID verification, the lock relay receives a command (transmitted to the Far unit) to open the door. • MD-W11F FAR Unit: The Far unit is connected to a proximity card reader and/or keypad, and controls the door lock relay. • MD-W11BP Battery Pack: The Battery Pack is mounted only on the MD-W11 Far Unit side (See Installing the MD-W11BP Battery Pack, on page 16). The MD-W11N and the MD-W11F are connected to the controller and the door components (lock, door monitor, reader). Both units are transceivers: the NEAR unit receives the data transmitted from the Reader, and sends it to the controller. If authorized, the controller sends authorization to the NEAR unit, which transmits authorization to the FAR unit. The FAR unit then opens the door. The Wireless Access Control Door Interface makes the transfer of data between the Controller input, the outputs, and the door components (such as Lock, Reader, Door Monitor, and Exit Button) transparent, as if the door components were connected directly to the controller. 3.2 General Installation Requirements The installation kit includes: • One drilling template (Label /Sticker) Page 9 MD-W11 Installation Manual Installation and Wiring One Security spline key One Security hex screw Four mounting screws Four wall plugs Fixed External antenna (G Model) • • • • • 3.3 Installing the MD-W11N Unit The NEAR unit can be connected to a standard Rosslare controller, such as the AC-225. Decide where to mount the unit, and install it as follows: 1. Use the spline key to remove the case security screw from the back of the unit, as shown in Figure 4. Figure 4: MD-W11 Back Cover 2. 3. Use the drilling template to determine where to drill holes in the wall. Use the hardware to mount the back plate on the wall. MD-W11 Installation Manual Page 10 Installation and Wiring Notes: 4. 3.4 We highly recommend to use the bottom left mounting hole, as it used for the purpose of back tamper when a person attempts to dislodge the unit from the wall. See Figure 4: MDW11 Back Cover marked with A. Wire the unit as instructed in the chapter on Wiring the MDW11N Unit, below, and Figure 5: MD-W11N NEAR Unit Wiring Diagram, on page 12. Wiring the MD-W11N Unit Wire the following terminals between the Controller's Input and Output to the MD-W11N Near Unit, as shown in Figure 5: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Power supply connection (+12V and GND) System tamper (STAM) Supervision failure (SPV) - Far unit has supervision failure Low battery (LBAT) - Far unit has low battery AC Fail (AC) - Far unit has power failure Data 0 (D0) Data 1 (D1) Reader LED control (LED input) Far Reader Tamper (TMP) Connection for lock (Lock input) Relay 1 REX (output) Relay 2-Door monitor (output) Notes: 1. System tamper (STAM), Supervision failure (SPV), Low battery (LBAT), AC Fail (AC) are outputs which can be connected to any input of AC-225 and in AxTrax this input should be configured accordingly (using Panel Links). 2. If either the Far reader or the Near reader, or both have been tampered with, the STAM status changes, and retains this status until both readers have been closed. Page 11 MD-W11 Installation Manual Installation and Wiring Figure 5: MD-W11N NEAR Unit Wiring Diagram MD-W11 Installation Manual Page 12 Installation and Wiring Figure 6: Sample Wiring Detail Note: Figure 6 shows sample input connections to any inputs, and is relevant to: AC-215/225/525. The relevant input can be configured to result in the required outcome, using AxTrax and Panel Links. Note: 1. The connection between the REX Input and Relay 1 is always COM+ N.O. or COM + N.C. so that only two lines connect this pair. 2. The connection between the Door Monitor Input and Relay 2 is always COM+ N.O. or COM + N.C. so that only two lines connect this pair. Page 13 MD-W11 Installation Manual Installation and Wiring 3.5 Installing the MD-W11F Unit The Far unit can be connected to a standard Rosslare reader, such as the AY-K12. The optional battery box can then be attached to the wall next to the Far unit. 1. 2. 3. 4. 5. 6. 3.6 Attach the battery box to the wall with two screws. Insert the wires from the reader and from the battery to the hole in the side of the Far unit box. Attach the side of the unit box to the wall with four screws. Attach the wires to the PCB. Cover both the battery and the Far unit boxes. Tighten the screws on the bottom of both boxes so that they remain closed. Wiring the MD-W11F Unit Wire the following terminals between the Controller's Input and Output to the MD-W11 Far Unit, as shown in Figure 7: MD-W11N FAR Unit Wiring Diagram on page 15: 1. 2. 3. 4. 5. 6. 7. 8. 12-24 VAC or 15-24VDC to the VIN+ and VINOptional backup battery that connects to BAT+ and BAT12V and GND power output for the Reader. Data 0 Wiegand (D0) (input) Data 1 Wiegand (D1) (input) LED - Reader LED control (output) TMP - Input for receiving reader tamper alert Normally Open (NO)/Normally Closed (NC) and COM of 5A Form C relay to the door’s lock 9. REX - Optional input for Request for Exit 10. DM - Optional input for door monitor contact MD-W11 Installation Manual Page 14 Installation and Wiring Figure 7: MD-W11N FAR Unit Wiring Diagram Page 15 MD-W11 Installation Manual Installation and Wiring 3.7 Installing the MD-W11BP Battery Pack Only install the MD-W11BP battery pack in the MD-W11 Far Unit. Decide where to mount the unit, and install the battery pack as follows: 1. 2. 3. 4. Use the spline key to remove the security screw from the bottom of the case, and open the unit. Use the drilling template to locate where to drill holes in the wall. Use the hardware provided to mount the back plate on the wall. Wire the battery pack as shown in Figure 8. Figure 8: MD-W11BP Battery Pack Note: The battery pack comes with a battery installed. The size of the case is compatible with Rosslare’s BT-05 12VDC / 800mA SLA rechargeable battery. 3.8 Wiring the MD-W11BP Battery Pack In the Far unit only, connect the Red (+) and Black (GND) to MDW11F Bat (+) and Bat (-). MD-W11 Installation Manual Page 16 Installation and Wiring 3.9 Indications on the Near and Far Units Figure 9 shows the six LED’s (which indicate the unit’s current status) on the display panel of each unit : 1. 2. 3. 4. 5. 6. PWR – Power ON Tx – Sending transmission Rx – Receiving transmission ENRL – Enrolling TRBL – Trouble SYS – System OK Figure 9: LED Display Panel 3.10 Installer Recommendations To install the MD-W11 units most efficiently, place the Near and Far units facing each other, rather than placing them at a 90º angle to one another. Both transmission and reception are improved if the Near and Far units have the same polarity. In addition: 1. 2. 3. 4. Do not place any of the MD-W11 units next to an air conditioner, heater, blower, or an engine that generates a magnetic field. Do not place any unit next to an electronic device that transmits RF or next to an access control reader or device. Assure that metal fixtures and furnishings (e.g., doors or closets) are not in line with the Near and Far units. Assure that the Near and Far units are at the same approximate height, preferably above head level. Page 17 MD-W11 Installation Manual Enrollment 4. Enrollment Prevent loss of transmission data by enrolling each pair of Near and Far units. 4.1 Enrolling the Units 4.2 Dipswitches One unit cannot recognize the unique ID of another unit unless both units are enrolled so that they can work together. The dipswitches on both units are set as follows: Dipswitches 1-4: Dipswitch 5: Dipswitch 7: Not used OFF or ON OFF or ON Enrolling Dipswitch 8: Not used Dipswitch 6: Must be in the ON position. Used to set the channel. Used to set the channel. Normal mode – ON Enrolling mode – OFF Must be in the ON position. Up is ON 1 2 3 4 5 6 7 8 Down is OFF Note: Only handle the Dipswitches when the power is OFF. MD-W11 Installation Manual Page 18 Enrollment Set the unit channels with Dipswitches 5 and 6. Dipswitch Dipswitch Channel H Model ON ON OFF OFF ON OFF ON OFF 869.50 Mhz 868.45 Mhz 868.30 Mhz 868.15 Mhz Channel G Model 433.60 Mhz 433.40 Mhz 433.20 Mhz 433.00 MHz Note: Dipswitches 5 and 6 must be synchronized in the Far and Near Units. Choose the same channel for both units. If the LED’s flash, the dipswitches have not been set properly. In that case, first re-set the dipswitches, and then power the unit off and on. During enrollment, the enrolling LED blinks first, followed by the TX LED, which blinks when it is transmitting. The enrolling process is finished when the enrolling LED shines steadily. After enrolling, return dipswitch 7 to ON (normal mode). Note: Only handle the Dipswitches when the power is OFF. Page 19 MD-W11 Installation Manual Enrollment 4.2.1. Near and Far Unit Modes The current unit mode is indicated by a steady or blinking LED. The three modes (Normal, Enrolling, and Trouble) of the NEAR and FAR units are described in detail below. Normal Mode: The normal mode is “idle,” and the LED’s behave as follows: PWR - Power ON - steady Tx - Sending transmission - blinking when sending Rx - Receiving transmission - blinking when receiving SYS - System OK – blinking • • • • Note: If SYS LED is not blinking, it indicates a serious error. A blinking TRBL indicates that there is trouble. Refer to the Trouble Mode for a list of possible problems. Enrolling Mode: The following steps indicate how to set the Enrolling mode (for retention of transmitted data). 1. 2. 3. 4. 5. 6. Set Dipswitch 7 on both units (Near and Far) to OFF. Power up both units. PWR IS steady and ENRL IS blinking. The Far unit sends its ID to the Near unit. The Near unit receives an ID and sends it to the Far unit The Far unit receives the Near unit’s ID and ENRL is steady. MD-W11 Installation Manual Page 20 Enrollment Trouble Mode: The MD-W11 FAR module detects the following troubles: • • • • • • Reader tamper FAR module tamper Low battery AC Fail RF device Failure / Problem Incorrect dipswitch setting Following detection of any of the said problems or failures, the FAR module behaves as shown in the following table: Problem Activity Reader tamper Sends trouble and problem to the Near module. FAR module tamper Sends trouble and problem to the Near module. Low battery Sends trouble and problem to the Near module. Trouble LED turns on. AC Fail Sends trouble and problem to the Near module. Trouble LED turns on. RF device Failure / Problem Trouble LED flashes at a fast rate. (after power on) Incorrect dipswitch setting All LEDs flash at a slow rate. (after power on) Page 21 MD-W11 Installation Manual Enrollment The MD-W11 Near module detects following troubles: • • • • NEAR module tamper Supervision Fail RF device Failure / Problem Incorrect dipswitch setting Following detection of any of the said problems or failures, the NEAR module behaves as shown in the following table: Problem name Activity NEAR module tamper Activates NEAR units’ tamper output Supervision Failure Activates NEAR units’ supervision output. Trouble LED turns on. RF device Failure / Problem Trouble LED flashes at a fast rate. (after power on) Incorrect dipswitch setting All LEDs flash at a slow rate. (after power on) MD-W11 Installation Manual Page 22 Operational Information 5. Operational Information The units should be no more than 300 meters from one another in an open field. The Far unit has one dipswitch with eight buttons, the default for all of which is On. The end-user only uses button #7 to enroll the Near and Far units. When the user turns button #7 to Off, the Near unit recognizes the Far unit so the units work with each other. The Far unit can also be attached to a REX (request for exit) button, a door monitor to indicate whether a door is open or closed, and a tamper to check whether the cover was opened. These indications are transmitted from the Far unit to the Near unit, which then sends them to the controller. The proximity reader reads card information, and sends it from the Far unit to the Near unit and to the controller to determine which door to open. If applicable, the controller sends authorization to open the door to the Near unit, which transmits the authorization to the Far unit, and the door is opened. Page 23 MD-W11 Installation Manual Limited Warranty Appendix A. Limited Warranty ROSSLARE ENTERPRISES LIMITED S (Rosslare) TWO YEARS LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's TWO YEARS LIMITED WARRANTY is subject to the following conditions: Warranty Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable. Products Covered By This Warranty and Duration ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that the MD-W11 Wireless Access Control Door Interface, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 2 years (24 Months). Warranty Remedy Coverage In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately required. If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES. To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation. Rosslare will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center. MD-W11 Installation Manual Page 24 Limited Warranty Exclusions and Limitations ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, or to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE. This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective. Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim. ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages. Limited Warranty Terms THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD. AND ITS SUBSIDIARIES’ WARRANTY THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE. 392B THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE SPECIFICALLY EXCLUDED. 39B IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, OR FOR ANY OTHER INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF USE, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND LOSS OF PROFITS, ARISING OUT OF THE INSTALLATION, USE, OR INABILITY TO USE SUCH PRODUCT, TO THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW . 394B THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY. 395B Page 25 MD-W11 Installation Manual Declaration of Conformity Appendix B. Declaration of Conformity THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS B DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE IN A RESIDENTIAL INSTALLATION. THIS EQUIPMENT GENERATES, USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. HOWEVER, THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION. IF THIS EQUIPMENT DOES CAUSE HARMFUL INTERFERENCE TO RADIO OR TELEVISION RECEPTION, WHICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON, THE USER IS ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES: • • • • Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. MD-W11 Installation Manual Page 26 Technical Support Appendix C. Technical Support Asia Pacific, Middle East Rosslare Security Products Headquarters 905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com United States and Canada 1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com Europe, Africa Global Technical Support & Training Center HaMelecha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com South America Presbitero Actis 555, Oficina 31. San Isidro. Buenos Aires. Argentina Tel: +5411-5273-6383 Tel: +305-921-9919 E-mail: support.la@rosslaresecurity.com Web Site: www.rosslaresecurity.com Page 27 MD-W11 Installation Manual 0706-0960234+00 www.rosslaresecurity.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Chanie Tessler Company : Context Create Date : 2010:11:25 09:40:05+02:00 Modify Date : 2010:11:25 09:41:25+02:00 Source Modified : D:20101125073825 Subject : Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2010:11:25 09:41:25+02:00 Creator Tool : Acrobat PDFMaker 9.1 for Word Document ID : uuid:ed00b251-bed0-4c37-bcd3-028e0a659d29 Instance ID : uuid:206f014c-e71f-4ebb-bb75-d4f3dd1c244a Format : application/pdf Title : MD-W11 Installation Manual Description : Creator : Chanie Tessler Producer : Adobe PDF Library 9.0 Keywords : Page Layout : OneColumn Page Count : 31 Signing Date : 2010:11:25 09:41:25+02:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, ExportEXIF Metadata provided by EXIF.tools