Rosslare SA-61H Wireless Smoke Detector User Manual new A4

Rosslare Enterprises Ltd Wireless Smoke Detector new A4

Manual r1

Download: Rosslare SA-61H Wireless Smoke Detector User Manual new A4
Mirror Download [FCC.gov]Rosslare SA-61H Wireless Smoke Detector User Manual new A4
Document ID1804442
Application IDKxvlZmmYpMhHpbROSKx/Lg==
Document DescriptionManual r1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize72.21kB (902629 bits)
Date Submitted2012-09-28 00:00:00
Date Available2012-09-28 00:00:00
Creation Date2012-09-19 14:06:19
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2012-09-19 14:06:22
Document Titlenew A4 template
Document CreatorAcrobat PDFMaker 10.0 for Word
Document Author: sam goldberg

SA-61
Wireless Smoke Detector
September 2012
Installation Manual
1. Introduction
The SA-61 is a battery-operated Wireless Smoke Detector.
It is available in two frequencies: 433.92 MHz or 868.35 MHz.
The smoke sensor unit can easily be plugged into or detached from the
wireless base unit (AS-60) for cleaning and maintenance purposes.
Figure 1: SA-61
A mechanical key on the sensor is designed to avoid mismatching or
incorrect installation of the sensor and base. The sensor chamber is
engineered to sense smoke from a wide range of combustion sources.
The chamber is well protected from insects and dust contamination.
A LED indicator on the sensor unit shows the operating status and
Alarm mode, while an RF LED is located in the base unit and indicates
RF transmissions, such as alarms and tamper.
The SA-61 smoke detector has a low profile, as well as a professional
and trendy appearance.
2. Technical Specifications
2.1
Electrical Characteristics
Power Supply Voltage
CR123 3 V 1300 mAh
Battery Life
Three years with regular use
Avg. Standby Current
30 µA
Max. Alarm Current
75 mA
Siren Output
85 dB at 1 m (built-in)
Sensitivity
2.5%/ ft nominal (0.5~4%/ft)
Frequency
G (433.92 MHz), H (868.35 MHz)
2.2
Indoor
Operating Temperature
0°C to 35.8°C (32°F to 100°F)
Storage Temperature
-20°C to 70°C (-4°F to 158°F)
Operating Humidity
0 to 95% RH (non-condensing)
The indicated LED flashes once every 344 seconds
(to save battery life) to show it is working.
Alarm Mode
The detector goes into Alarm mode if it detects
smoke. In Alarm mode, the indicated LED and the RF
LED quickly flashes and the Piezoelectric sounder is
activated.
Low Battery Mode
When the battery voltage is low, the detector beeps
every 43 seconds.
120 g (4.23 oz)
Dimensions (L x W x H)
121.9 x 121.9 x 34 mm (4.8 x 4.8 x 1.34 in.)
Signaling and Events
Tamper Event
When the sensor is disconnected from the base or
the base unit from the ceiling.
Signaling Type
Red LED on detector, red LED in base unit
Report Types
Alarm, Tamper, Low Battery
Alarm Report:
Physical Characteristics
Weight
Modes of Operation
Normal Mode
2.5
Environmental Characteristics
Environment
2.3
2.4
•
Every 20 seconds during first 3 min
•
Every 3 min from 3 min till 30 min
•
Alarm event is no longer sent after 30 min or
immediately upon Alarm Restore (When the ambient environment somke concetration is lower than
the alarm level for a zone)
3. Installation
3.1
Choosing a Mounting Location
3.2
A smoke detector should be installed according to NFPA (National Fire
Protection Association) Standard 72. For complete coverage in
residential units, smoke detectors should be installed in all rooms, halls,
storage areas, and basements. At the least, one detector should be
placed on each floor and in each sleeping area.
Install smoke detectors as close to the center of the ceiling as possible
or at least 10 cm (4 inches) away from any wall or corner.
Do NOT locate smoke detectors at the top of peaked or gabled
ceilings; the dead air space in these locations may prevent the unit
from detecting smoke. Avoid areas with turbulent air flow such as near
doors, fans or windows. Rapid air movement around the detector may
prevent smoke from entering the unit and affected the accuracy.
Smoke Detector Limitations

Smoke detectors will not sense a fire if the smoke does not reach
the sensor.

Smoke detectors may not be heard. Be sure to locate the smoke
detector within hearing distance.

Smoke from a slow fire rises slowly and may not reach the smoke
detector until the fire gets bigger.

To keep your smoke detectors working properly, be sure to
maintain the unit according to manufacturer’s recommendations
and UL and NFPA standards.
3.3
Disassembly
3.5
The unit arrives assembled, so you must disassemble the unit into its
three pieces before you can mount it.
Inserting the Battery
To disassemble:
The battery compartment is designed to meet UL requirement. A lever
has been inserted to avoid attaching the sensor unit without the
battery being inserted.
1. Turn the sensor counter-clockwise to the “Loose” position as
shown in Figure 2 and gently remove the sensor.
1. Load the battery into the base compartment as shown in Figure 4.
To insert the battery:
Figure 2: Loose and Lock Positions
Figure 4: Battery Installation
2. Gently separate the top part of the base unit from the lower part.
3.4
Mounting the Base Unit
The AS-60 base unit provides different punch out options for different
gang box standards for mounting to 3 1/2-inch and 4-inch octagonal,
single-gang, and 4-inch square back boxes (Figure 3).
3.6
Assembly
Once you have mounted the base unit and inserted the battery, you
are ready to close the unit.
To assemble the unit:
1. Replace the top part of the base unit with its bottom part that has
been mounted by lining up the two lines as shown in Figure 5.
Figure 5: Base Cover Insertion
2. Attach the sensor unit onto the base unit as shown in Figure 6 and
turn the sensor clockwise to the Lock position (Figure 2).
Figure 6: Sensor Insertion
Figure 3: Punch Out Options for Various Gang Box Standards
To mount the base unit:
1. Mark two mounting points in the wall.
2. Drill into the marked points and insert wall plugs/gang box.
3. Screw and fix the base unit.
4. Testing
Once the detector is installed, you should test the unit.
4.1
General Testing
4.2
RF Testing
To test the unit:
To test the RF connection:
1. Press and hold the Test button on the sensor. The following
occurs:
1. Remove the sensor.

Both LEDs flash quickly

The Piezoelectric sounder is activated

The smoke detector transmits an alarm to the wireless alarm
panel
2. Remove the top cover of the base unit.
3. Press the S3 button (Figure 7) for more than 5 seconds.
Figure 7: S3 Button
Release the Test button to return to Normal mode.
The unit sends 10 RF messages to the system every four seconds
and then returns to Normal mode
5. Maintenance
5.1
Cleaning
5.2
The unit runs a self-check for cleanliness every 43 seconds. If three
consecutive tests fail, the unit beeps three times every 43 seconds.
Battery Replacement
When the detector’s battery is low, the detector beeps once every 43
seconds. If the detector is connected to a wireless security network, it
sends a low battery warning message.
To clean the unit, pass a vacuum cleaner with a brush attachment
gently over the front frilled sections and the sides of the smoke
detector.
The smoke detector continues to operate with a low battery for at least
7 days.
Replace the battery when a low battery is indicated.
6. FCC Statement


This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

This device may not cause harmful interference.

This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.
Limited Warranty
EXCLUSIONS AND LIMITATIONS
ROSSLARE shall not be responsible or liable for any damage or loss
resulting from the operation or performance of any Product or any
systems in which a Product is incorporated. This warranty shall not
extend to any ancillary equipment not furnished by ROSSLARE, which is
attached to or used in conjunction with a Product, nor to any Product
that is used with any ancillary equipment, which is not furnished by
ROSSLARE.
This warranty does not cover expenses incurred in the transportation,
freight cost to the repair center, removal or reinstallation of the
product, whether or not proven defective.
Specifically excluded from this warranty are any failures resulting from
Customer's improper testing, operation, installation, or damage
resulting from use of the Product in other than its normal and
customary manner, or any maintenance, modification, alteration, or
adjustment or any type of abuse, neglect, accident, misuse, improper
operation, normal wear, defects or damage due to lightning or other
electrical discharge. This warranty does not cover repair or replacement
where normal use has exhausted the life of a part or instrument, or any
modification or abuse of, or tampering with, the Product if Product
disassembled or repaired in such a manner as to adversely affect
performance or prevent adequate inspection and testing to verify any
warranty claim.
ROSSLARE does not warrant the installation, maintenance, or service of
the Product. Service life of the product is dependent upon the care it
receives and the conditions under which it has to operate.
In no event shall ROSSLARE be liable for incidental or consequential
damages.
LIMITED WARRANTY TERMS
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE’S WARRANTY.
THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR
NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE.
THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL
OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION,
ROSSLARE ENTERPRISES LIMITED (ROSSLARE) TWO-YEAR LIMITED
WARRANTY is applicable worldwide. This warranty supersedes any
other warranty. ROSSLARE'S TWO-YEAR LIMITED WARRANTY is
subject to the following conditions:
WARRANTY
Warranty of ROSSLARE'S products extends to the original purchaser
(Customer) of the ROSSLARE product and is not transferable.
PRODUCTS COVERED BY THIS WARRANTY AND DURATION
ROSSLARE ENTERPRISES LTD. AND/OR SUBSIDIARIES (ROSSLARE)
warrants that the SA-61 Wireless Smoke Detector to be free from
defects in materials and assembly in the course of normal use and
service. The warranty period commences with the date of shipment to
the original purchaser and extends for a period of 2 years (24 months).
WARRANTY REMEDY COVERAGE
In the event of a breach of warranty, ROSSLARE will credit Customer
with the price of the Product paid by Customer, provided that the
warranty claim is delivered to ROSSLARE by the Customer during the
warranty period in accordance with the terms of this warranty. Unless
otherwise requested by a ROSSLARE representative, return of the failed
product(s) is not immediately required.
If ROSSLARE has not contacted the Customer within a sixty (60) day
holding period following the delivery of the warranty claim, Customer
will not be required to return the failed product(s). All returned
Product(s), as may be requested at ROSSLARE’S sole discretion, shall
become the property of ROSSLARE.
To exercise the warranty, the user must contact ROSSLARE Enterprises
Ltd. to obtain an RMA number after which, the product must be
returned to the Manufacturer freight prepaid and insured.
In the event ROSSLARE chooses to perform a product evaluation within
the sixty (60) day holding period and no defect is found, a minimum
US$ 50.00 or equivalent charge will be applied to each Product for
labor required in the evaluation.
ROSSLARE will repair or replace, at its discretion, any product that
under normal conditions of use and service proves to be defective in
material or workmanship. No charge will be applied for labor or parts
with respect to defects covered by this warranty, provided that the
work is done by ROSSLARE or a ROSSLARE authorized service center.
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE SPECIFICALLY EXCLUDED.
IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE
PURCHASE PRICE OF THE PRODUCT, OR FOR ANY OTHER INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF
USE, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND LOSS OF PROFITS,
ARISING OUT OF THE INSTALLATION, USE, OR INABILITY TO USE SUCH PRODUCT, TO
THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY
LAW.
THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF
THE PROVISIONS OF THIS LIMITED WARRANTY.
Contact Information
Asia Pacific, Middle East, Africa
Latin America
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852 2795-5630
Fax: +852 2795-1508
support.apac@rosslaresecurity.com
Rosslare Latin America
Buenos Aires, Argentina 1642
support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86 755 8610 6842
Fax: +86 755 8610 6101
support.cn@rosslaresecurity.com
United States and Canada
Rosslare Security Products, Inc.
Southlake, TX, USA 76092
Toll Free: +1-866-632-1101
Local: +1-817-305-0006
Fax: +1-817-305-0069
support.na@rosslaresecurity.com
Rosslare Electronics India Pvt Ltd.
Tel/Fax: 91 20 40147830
Mobile: 91 9975768824
sales.in@rosslaresecurity.com
Europe
Rosslare Israel Ltd.
Rosh HaAyin, Israel 48091
Tel: +972 3 938-6838
Fax: +972 3 938-6830
support.eu@rosslaresecurity.com
www.rosslaresecurity.com
0706-0960435+01
India

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Modify Date                     : 2012:09:19 14:06:22+03:00
Create Date                     : 2012:09:19 14:06:19+03:00
Metadata Date                   : 2012:09:19 14:06:22+03:00
Creator Tool                    : Acrobat PDFMaker 10.0 for Word
Document ID                     : uuid:e56474d9-a809-4b3b-9a5d-1e3334031515
Instance ID                     : uuid:7c597bd5-25ca-4384-9dbf-1c63b0b3b449
Subject                         : 7
Format                          : application/pdf
Title                           : new A4 template
Creator                         : sam goldberg
Producer                        : Adobe PDF Library 10.0
Source Modified                 : D:20120919110603
Company                         : SYO
Product 0020 Name               : Product Name
Page Layout                     : OneColumn
Page Count                      : 4
Author                          : sam goldberg
Product Name                    : Product Name
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GCDSA-61H

Navigation menu