Ruckus FastIron 08.0.30g Release Notes, V1 Fast Iron Notes 08030g

FastIron 08.0.30g Release Notes FastIron_08030g_ReleaseNotes_v1

2017-12-14

User Manual: Ruckus FastIron 08.0.30g Release Notes

Open the PDF directly: View PDF PDF.
Page Count: 141 [warning: Documents this large are best viewed by clicking the View PDF Link!]

FastIron Software Release 08.0.30g Release Notes 1
FastIron Software Release 08.0.30g for Brocade
FCX, FastIron SX, and ICX Switches
Release Notes, Version 1
Document History
Version of Document
Summary of Changes
Publication Date
FastIron Software Release
08.0.30g for Brocade FCX,
FastIron SX, and ICX Switches
Release Notes v1.0
Initial release.
March 17, 2016
FastIron Software Release 08.0.30g Release Notes 2
Copyright © 2016 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, Brocade Assurance, the B-wing symbol, ClearLink, DCX, Fabric OS, HyperEdge, ICX, MLX, MyBrocade, OpenScript, VCS, VDX,
Vplane, and Vyatta are registered trademarks, and Fabric Vision is a trademark of Brocade Communications Systems, Inc., in the United
States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of others.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any
equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this
document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may
not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data
contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the
accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs
that accompany it.
The product described by this document may contain open source software covered by the GNU General Public License or other open
source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to
the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
FastIron Software Release 08.0.30g Release Notes 3
Contents
Enhancements in FastIron 08.0.30g ....................................................................................................5
Enhancements in FastIron 08.0.30fa ...................................................................................................5
Enhancements in FastIron 08.0.30f .....................................................................................................5
New and enhanced commands............................................................................................................. 5
Enhancements in FastIron 08.0.30e ....................................................................................................5
New and enhanced commands............................................................................................................. 6
Enhancements in FastIron 08.0.30d ....................................................................................................6
New and enhanced commands............................................................................................................. 6
Enhancements in FastIron 08.0.30c.....................................................................................................7
Enhancements in FastIron 08.0.30b ....................................................................................................7
New and enhanced commands............................................................................................................. 8
Enhancements in FastIron 08.0.30aa ..................................................................................................9
Enhancements in FastIron 08.0.30a ....................................................................................................9
Enhancements in FastIron 08.0.30 ......................................................................................................9
New hardware........................................................................................................................................... 9
New software .......................................................................................................................................... 10
Software feature documentation ....................................................................................................... 11
New and enhanced commands........................................................................................................... 13
Hardware support ............................................................................................................................ 14
Supported devices .................................................................................................................................. 14
Unsupported devices .............................................................................................................................. 15
Supported optics ..................................................................................................................................... 15
Supported FSX modules .......................................................................................................................... 15
Unsupported FSX modules ...................................................................................................................... 16
Software support .................................................................................................................................... 16
Software or image file names ........................................................................................................... 17
Software image files for Release 08.0.30g .............................................................................................. 17
PoE firmware files ................................................................................................................................... 17
FastIron Software Release 08.0.30g Release Notes 4
Licensing information ....................................................................................................................... 18
System requirements ....................................................................................................................... 19
Configuration considerations ........................................................................................................... 19
Limitations and restrictions .............................................................................................................. 19
Upgrade and migration considerations ............................................................................................. 19
Upgrading to this release ................................................................................................................. 19
Downgrading to a previous release ................................................................................................... 19
FastIron library ................................................................................................................................ 19
Deliverables............................................................................................................................................. 20
Reporting errors in the guides ................................................................................................................ 21
Contacting Brocade .......................................................................................................................... 21
Support ................................................................................................................................................... 21
Getting technical help ............................................................................................................................. 21
Closed defects with code changes in Release 08.0.30g ...................................................................... 22
Closed defects with code changes in Release 08.0.30fa ..................................................................... 28
Closed defects with code changes in Release 08.0.30f ....................................................................... 28
Closed defects with code changes in Release 08.0.30e ...................................................................... 36
Closed defects with code changes in Release 08.0.30d ...................................................................... 40
Closed defects with code changes in Release 08.0.30c ....................................................................... 59
Closed defects with code changes in Release 08.0.30b ...................................................................... 61
Closed defects with code changes in Release 08.0.30aa .................................................................... 98
Closed defects with code changes in Release 08.0.30a ...................................................................... 98
Closed defects with code changes in Release 08.0.30 ...................................................................... 100
Closed defects without code changes in Release 08.0.30 ................................................................. 134
FastIron Software Release 08.0.30g Release Notes 5
Enhancements in FastIron 08.0.30g
FastIron 08.0.30g release contains defect fixes. There are no enhancements in this release.
Enhancements in FastIron 08.0.30fa
FastIron 08.0.30fa release contains defect fixes. There are no enhancements in this release.
Enhancements in FastIron 08.0.30f
Brocade FastIron Release 08.0.30f introduces new enhancements.
Key exchange method - By default, diffie-hellman-group1-sha1 is the key-exchange method used
to establish an SSH connection. You can change the default key-exchange method and configure
diffie-hellman-group14-sha1 as the key-exchange method using the ip ssh key-exchange-
method dh-group14-sha1 command. The diffie-hellman-group14-sha1 method provides
enhanced encryption of shared secrets between two devices. This is supported only on FCX
devices.
MIB support for RFC 2787 - Definitions of Managed Objects for the Virtual Router Redundancy
Protocol.
Remote console authentication for standby and member units in the stack - When console
session is established to standby or member units to active unit in a stack, user authentication
will be prompted if enable aaa console command is configured. If console timeout is configured,
on console time out re-authentication of the session will occur. Before user authentication, the
banner updated to running configuration is displayed.
New and enhanced commands
The following command is new for the 08.0.30f release, and are described in detail in the FastIron
Command Reference.
ip ssh key-exchange-method dh-group14-sha1 - Configures diffie-hellman-group14-sha1 as the
key-exchange method to establish an SSH connection.
inline power non-pd-detection enable - Enables detection for non powered endpoints or
devices (non-PD).
show inline power The command output was modified.
Enhancements in FastIron 08.0.30e
FastIron 08.0.30e release contains defect fixes and the following enhancements.
With this release IPv6 static route feature is part of the Base license.
FastIron Software Release 08.0.30g Release Notes 6
New and enhanced commands
The following commands are new for the 08.0.30e release.
ip follow-ingress-vrf If this command is configured, SNMP reply is sent either through default-
VRF using management port or management-VRF based on the SNMP-request’s ingress-VRF. By
default, when there is a conflict in route, SNMP-reply is sent through management-VRF
irrespective of the VRF in which SNMP-Request is received. Use this command if SNMP-Reply
has to be sent on the VRF in which SNMP-Request is received.
ip add-host-route-first This command should be configured when an TCP connection
establishment packet is routed to a destination interface for which ARP is not resolved.
Configuring this command helps to establish the connection as a part of first TCP handshake
itself.
Enhancements in FastIron 08.0.30d
Brocade FastIron Release 08.0.30d introduces new enahcncements.
LLDP-MED Voice VLAN advertisement - LLDP and CDP protocols are used to advertise Voice
VLAN information to a client such as an IP Phone connected to a port so that it learns the Voice
VLAN information. This was a manual configuration and with the current enhancement this can
be made dynamic. To make this process dynamic, Brocade VSA-11 with an attribute name
"Foundry Voice Phone Config" is used. When the switch receives such an attribute from the
RADIUS server, it automatically configures the CDP/LLDP information to advertise the Voice
VLAN to the client. LLDP requires DSCP and Priority values to configure the MED policy.
Optionally, DSCP and Priority values may also be specified in the VSA.
RADIUS over TLS - RADIUS over TLS secures the communication between RADIUS/TCP peer using
TLS. RADIUS over TLS obsoletes the use of IP addresses and shared MD5 secrets to identify other
peers. RADIUS over TLS is supported for both IPv4 and IPv6.
SCP performance improvement - The SCP file transfer speed over high latency connections is
increased. The SCP file transfer speed enhancement is supported only on Brocade ICX 7750,
Brocade ICX 7450, and Brocade ICX 7250.
New and enhanced commands
The following commands are new for the 08.0.30d release, and are described in detail in the FastIron
Command Reference.
peer-info
The following commands are enhanced in the 08.0.30d release, and are described in detail in the
FastIron Command Reference:
radius-server host
FastIron Software Release 08.0.30g Release Notes 7
show lag
The following commands are deprecated in the 08.0.30d release, and are described in detail in the
FastIron Command Reference:
mac-authentication enable-dynamic-vlan
Enhancements in FastIron 08.0.30c
FastIron 08.0.30c release contains defect fixes. There are no enhancements in this release.
Enhancements in FastIron 08.0.30b
Brocade FastIron Release 08.0.30b introduces serveral new features and enahcncement.
Flexible Authentication enhancement
o Additional RADIUS attribute support for Dynamic VLAN assignments
o Dynamic Tagged VLAN assignements not limited to Voice VLANs
o Support for single and multiple untagged VLANs per port is configurable
Stacking enhancements
o ICX 7750-48C and ICX 7750-48F devices support stacking distances of 10 Km using LR4
fiber optic cables attached to ports 1/2/5 and 1/2/6. Manual trunk configuration using
port 1/2/1 or 1/2/4 as a lead default stacking port is required.
LAG symmetric load balancing
o Sometimes DPI devices and firewalls are installed as a bump in the wire deployment on
certain child links of a LAG. In such a case symmetrical hashing is very important for LAG
interfaces. This allows the reverse flow of traffic to be directed through the same child
link on the LAG and is bound to flow through the same DPI device. This enables proper
accounting on the DPI of the traffic in both the forward and reverse flows. The same is
true for firewall devices as well so they could filter out unwanted traffic in both the
directions.
LAG Scaling
o In FastIron 08.0.30b, the number of LAGs supported on each ICX 7250, ICX 7450, or ICX
7750 increases to 256. When you downgrade from FastIron 08.0.30b, only the first 128
LAGs are deployed.The remaining LAGs are not deployed, and related configuration is
lost.
DHCP snooping, DAI, and IP source guard over LAG
o DHCPv4 snooping, Dynamic ARP inspection and IP source guard are supported over LAG.
DHCPv4 snooping, Dynamic ARP inspection and IP source guard were previously
supported features and in 8.0.30b were supported over LAG as well.
Delay time in notifying VE down event
o When all the ports in the VLAN go into an inactive state (for example, the non-
forwarding state), the device notifies the Layer 3 protocols of the VE down event only
FastIron Software Release 08.0.30g Release Notes 8
after the configured timer expires. Once the timer expires, the device checks if any of
the ports is in the forwarding state. If no ports are in the forwarding state, the device
notifies the Layer 3 protocols of the VE down event. If any of the ports is in the
forwarding state, the device ignores the down event.
Enhancement
ICX
6450
ICX
6610
ICX
6650
ICX
7250
FSX 800
FSX 1600
Book title
FlexAuth
enhancements
Yes
Yes
No
Yes
No
FastIron Ethernet Switch Security
Guide
Stacking
enhancements
No
No
No
No
No
FastIron Ethernet Switch Stacking
Configuration Guide
LAG
symmetric
load balancing
No
No
No
Yes
No
FastIron Ethernet Switch Layer 2
Configuration Guide
LAG Scaling
No
No
No
Yes
No
FastIron Ethernet Switch Layer 2
Configuration Guide
DHCP
snooping, DAI
and IP source
guard over
LAG
Yes
Yes
No
Yes
No
FastIron Ethernet Switch Security
Guide
Delay time in
notifying VE
down event
No
No
No
Yes
No
FastIron Ethernet Switch Layer3
Configuration Guide
New and enhanced commands
The following commands are new for the 08.0.30b release, and are described in detail in the FastIron
Command Reference.
authentication auth-vlan-mode
auth-vlan-mode
delay-notifications
ip arp inspection syslog disable
load-balance symmetric
mac-authentication enable-dynamic-vlan
show ip dhcp snooping flash
The following commands are enhanced in the 08.0.30b release, and are described in detail in the
FastIron Command Reference:
show arp
FastIron Software Release 08.0.30g Release Notes 9
show ip dhcp snooping info
show ip interface ve
show ip static-arp
Enhancements in FastIron 08.0.30aa
Brocade FastIron Release 08.0.30aa contains several defect fixes, but no new features. This release
supports only ICX 7750, ICX 7450, and ICX 7250 platforms.
Enhancements in FastIron 08.0.30a
Brocade FastIron Release 08.0.30a contains several defect fixes, but no new features.
Refer to Closed defects with code changes in Release 08.0.30a for a list of the defects that are fixed in
this release.
Note the following change to the Brocade ICX 7250 Ports on Demand (PoD) licencing:
To upgrade all 8 PoD ports to 10G, you must already have the 2 port capacity license installed on
the device. If the 2 port capacity license is not already installed, you must purchase and install it
before you can install the 8 port capacity license.
Refer to the FastIron Ethernet Switch Software Licensing Guide for additional details about licensing.
Enhancements in FastIron 08.0.30
Brocade FastIron Release 08.0.30 introduces several new software features and hardware
enhancements, with a continued commitment to The Effortless Network vision of making the network
flexible, easy to manage, and cost-effective. The Effortless Network is enabled by Brocade® HyperEdge®
Architecture, which brings campus networks into the modern era to better support mobility, security,
and application agility. This evolutionary architecture integrates innovative technologies to streamline
application deployment, simplify network management, and reduce operating costs.
New hardware
In the 08.0.30 release, a new ICX 7250 switch is introduced and supported.
The Brocade ICX 7250 switches are a series of high performance entry-level enterprise stackable
switches offering up to 8×1/10 GbE SFP+ ports for uplink or stacking. Available in 24-port and 48-port of
1 GbE RJ-45 configurations, the Brocade ICX 7250 can easily deliver sufficient bandwidth between the
edge and aggregation layers to support expanding video traffic, VDI adoption, and high-speed wireless
802.11ac deployment. The Brocade ICX 7250 switches offer the following features:
Eight 1/10G SFP+ ports for uplink or stacking
FastIron Software Release 08.0.30g Release Notes 10
Comprehensive support for a range of 1 GbE and10 GbE optics (refer to the Brocade Optics Family
Data Sheet).
ICX 7250-24P and ICX 7250-48P copper ports support PoE and PoE+on all ports.
Available external power supply for ICX 7250 power supply redundancy and additional POE power
(optional)
Supports up to 12 units in a single stack
One Gigabit Ethernet port (RJ-45) and one serial management port (mini-USB) to configure and
manage the switch through the CLI.
New software
Committed to enhancing the Brocade® HyperEdge® Architecture, FastIron 08.0.30 integrates the
following software features and enhancements to the Brocade FastIron product portfolio.
4x10G Breakout for 40G interfaces on ICX 7750
Brocade ICX 7750 devices support 4x10G breakout of the 40G interfaces.
Stacking for 10GE SFP+ on ICX 7450
Brocade ICX 7450 devices support linear and ring High Availability (HA) stack topologies using
the 10GE SFP+ interfaces.
OpenFlow v1.0 and v1.3 on ICX 7450 & ICX 7750
An OpenFlow-enabled router supports an OpenFlow Client (control plane software), which
communicates with an OpenFlow Controller using the OpenFlow protocol.
Media Access Control Security (MACsec) on ICX 7450
FastIron MACsec is a link-to-link Layer 2 Ethernet feature that uses shared keys to encrypt data
and provide secure delivery of data between participating ICX 7450 Series switches and other
Brocade switches that support MACSec. Encryption and integrity checks are performed by the
hardware. The security provided minimizes the threat of man-in-the-middle attacks, frame
sniffing or snooping, and other types of intrusion.
A new software license for the MACsec functionality is introduced. The MACsec license works
independently of the Premium, Advance, or POD licenses already installed on Brocade devices
and can be obtained from the software portal, as with other existing licenses.
LAG Enhancements on ICX 7250, ICX 7450, and ICX 7750
Support for 16 port LAG
32 ECMP Paths on ICX 7750
FastIron Software Release 08.0.30g Release Notes 11
ICX 7750 now supports up to 32 ECMP Paths
EEE on ICX 7450 and ICX 7250
Support for Energy Efficent Ethernet on ICX 7450 and ICX 7250
LAG Rename enhancement
Supports changing the name of an existing LAG
Egress counters MIB on ICX 6610, ICX 7750, ICX 7450, ICX 7250, and FCX
New MIB table to access egress counters for all the queues for a port.
External USB support on ICX 7750, ICX 7450, and ICX 7250
Supports copy files to and from the Brocade ICX 7750, ICX 7450, and ICX7250 using the USB
port.
DHCPv6 prefix delegation notification on ICX 7750 and ICX 7450
DHCPv6 prefix delegation notification allows a DHCPv6 server to dynamically delegate IPv6
prefixes to a DHCPv6 client using the DHCPv6 Prefix Delegation (PD) option.
Ethernet Remote Loopback on ICX 7750, ICX 7450, ICX 7250, ICX 6610, ICX 6450, ICX 6430, and FCX
On an interface, the switch loops traffic back from destination port to source port for enhanced
diagnostics and troubleshooting.
Layer 3 unicast routing over MCT on ICX 7750
Support for unicast routing protocols over MCT.
Layer 3 multicast routing over MCT on ICX 7750
Support for multicast routing protocols over MCT.
Per-port multi-user authentication
Up to 32 devices can be concurrently authenticated on a single port and each assigned to a
unique VLAN with unique ACLs.
Software feature documentation
The following table lists the software features, the supported platforms, and where the features are
documented.
FastIron Software Release 08.0.30g Release Notes 12
Enhancement
ICX
6450
ICX
6610
ICX
6650
ICX
7250
FSX 800
FSX 1600
Book title
4x10G
Breakout for
40G interfaces
No
No
No
No
No
FastIron Ethernet Switch
Administration Guide
Stacking for
10GE SPF+
interfaces
Yes
No
No
Yes
No
FastIron Ethernet Switch Stacking
Configuration Guide
OpenFlow
v1.0 and v1.3
No
Yes
No
No
No
FastIron Ethernet Switch Software
Defined Networking (SDN)
Configuration Guide
MACsec on
ICX 7450
No
Yes
No
No
No
FastIron Ethernet Switch Security
Configuration Guide
LAG
Enhancements
on ICX 7250,
ICX 7450, and
ICX 7750 16-
port LAG
No
No
No
Yes
No
FastIron Ethernet Switch Platform
and Layer 2 Switching Configuration
Guide
32 ECMP
Paths on ICX
7750
No
No
No
No
No
FastIron Ethernet Switch Layer 3
Routing Configuration Guide
EEE on ICX
7450 and ICX
7250
No
No
No
Yes
No
FastIron Ethernet Switch
Administration Guide
LAG Rename
enhancement
No
No
No
No
No
FastIron Ethernet Switch Platform
and Layer 2 Switching Configuration
Guide
Egress
counters MIB
No
Yes
No
Yes
No
Unified IP MIB Reference
External USB
support
No
No
No
Yes
No
FastIron Ethernet Switch
Administration Guide
Ethernet
Remote
Loopback
Yes
Yes
No
Yes
No
FastIron Ethernet Switch Platform
and Layer 2 Switching Configuration
Guide
DHCPv6 prefix
delegation
notification
No
No
No
No
No
FastIron Ethernet Switch Layer 3
Routing Configuration Guide
L3 unicast
routing over
MCT
No
No
No
No
No
FastIron Ethernet Switch Layer 3
Routing Configuration Guide
L3 multicast
routing over
MCT
No
No
No
No
No
FastIron Ethernet Switch Layer 3
Routing Configuration Guide
Per-port multi-
user
authentication
Yes
Yes
No
Yes
No
FastIron Ethernet Switch Security
Configuration Guide
FastIron Software Release 08.0.30g Release Notes 13
New and enhanced commands
The following commands are new for the 08.0.30 release, and are described in detail in the FastIron
Command Reference.
bandwidth (interface)
breakout ethernet
clear link-oam statistics
copy disk0
copy flash disk0
copy running-config disk0
copy startup-config disk0
eee
ethernet (EFM-OAM)
ethernet loopback
ethernet loopback (VLAN-aware)
ethernet loopback test-mac
flash-timeout
format disk0
ip dhcp-client continuous-mode max-duration
ip dhcp-client discover-interval
ip multicast-routing rpf-check mac-movement
ipv6 multicast-routing rpf-check mac-movement
link-oam
mount disk0
pdu-rate (EFM-OAM)
port-statistics-reset-timestamp enable
remote-loopback
reverse-path-check
rpf-mode
sflow sample-mode
sflow source
show breakout
show cpu
show cpu historgram
show eee-statistics
show eee-statistics ethernet
show ethernet loopback interfaces
show ethernet loopback resources
show files disk0
show interfaces lag
FastIron Software Release 08.0.30g Release Notes 14
show ip reverse-path-check
show ip reverse-path-check interface
show link-oam info
show link-oam statistics
show memory
show memory task
show power-savings-statistics
system-max max-ecmp
timeout (EFM-OAM)
unmounts disk0
update-lag-name
The following commands are enhanced in the 08.0.30 release, and are described in detail in the FastIron
Command Reference:
errdisable recovery Added loam-critical-event keyword.
set ip next-hop Added no-ttl-decrement option.
show ip multicast vlan Output includes flooding information.
show ip pim mcache Output includes Layer 3 multicast routing over MCT.
show ipv6 multicast vlan Output includes flooding information.
show version Output includes module serial number.
The following commands are enhanced in the 08.0.30 release and are described in detail in the Brocade
FastIron SX, FCX, and ICX Diagnostic Reference:
show tech-support Added header support.
supportsave Included core, system, infra, and display options.
Hardware support
This section lists the supported and unsupported devices for the 08.0.30 release of Brocade FastIron
products.
Supported devices
This 08.0.30 and later software release applies to the following Brocade products:
- FastIron X Series: FastIron SX 800 and 1600 (FSX 800 and FSX 1600)
The following Brocade FastIron management modules are compatible with the FastIron X Series
Chassis:
- SX-FI-ZMR-XL
- SX-FI-ZMR-XL-PREM6
FastIron Software Release 08.0.30g Release Notes 15
- SX-FI-2XGMR-XL
- SX-FI-2XGMR-XL-PREM6
- FCX Series (FCX)
- ICX 6610 Series (ICX 6610)
- ICX 6430 Series (ICX 6430, ICX 6430-C12)
- ICX 6450 Series (ICX 6450, ICX 6450-C12-PD)
- ICX 6650 Series (ICX 6650)
- ICX 7250 Series (ICX 7250-24, ICX 7250-24P, ICX 7250-48, ICX 7250-48P, ICX 7250-24G)
- ICX 7450 Series
- ICX 7750 Series (ICX 7750-26Q, ICX 7750-48F, and ICX 7750-48C)
For a complete list of supported modules in the 08.0.30 software release, refer to the section Supported
FSX modules.
Unsupported devices
This 08.0.30 and later software release does not support the following Brocade products:
- FastIron GS Series (FGS)
- FastIron LS Series (FLS)
- FastIron Edge (FES)
- FastIron Edge Switch X Series IPv4 models (FESX v4)
- FastIron Edge Switch X Series (IPv6 models) (FESX6)
- FastIron WS Series (FWS)
- FastIron SuperX
- TurboIron 24X (TI 24X)
For a complete list of unsupported modules in the 08.0.30 software release, refer to the section
Unsupported FSX modules.
Supported optics
For a list of supported fiber-optic transceivers that are available from Brocade, refer to the latest version
of the Brocade Optics Family data sheet available online at Brocade.com.
Supported FSX modules
This release supports the following modules on the FSX 800 and FSX 1600 devices.
Second generation modules
Third generation modules
SX-FI624C
SX-FI-24GPP
FastIron Software Release 08.0.30g Release Notes 16
Second generation modules
Third generation modules
SX-FI624HF
SX-FI-24HF
SX-FI624P
SX-FI-2XG
SX-FI62XG
SX-FI-8XG
SX-FI48GPP
In addition, SX-FI-ZMR-XL, SX-FI-ZMR-XL-PREM6, SX-FI-2XGMR-XL, and SX-FI-2XGMR-XL-PREM6 high
performance management modules are supported in this release. Only systems with all second
generation or all third generation modules are supported. No mixing of generations is allowed in this
release. The module in the lowest slot number is enabled first and will determine the mode of the
chassis. Any module not of the same generation as the first enabled module will not be enabled and will
be skipped in the bootup process.
Unsupported FSX modules
This release does not support the following modules on the FSX 800 and FSX 1600 devices.
First generation interface modules
Management modules
SX-FI424C
SX-FIZMR
SX-FI424P
SX-FIZMR-PREM
SX-FI424F
SX-FIZMR-6-PREM
SX-FI424HF
SX-FIZMR-6-PREM6
SX-FI42XG
SX-FI2XGMR4
SX-FI2XGMR4-PREM
SX-FI2XGMR6
SX-FI2XGMR6-PREM
SX-FI2XGMR6-PREM6
Software support
For a complete list of the supported software and FastIron features, refer to the latest version of the
FastIron Ethernet Switch Feature Support, RFC Compliance, and IEEE Compliance Matrix on
www.brocade.com or my.brocade.com.
FastIron Software Release 08.0.30g Release Notes 17
Software or image file names
Software image files for Release 08.0.30g
Table 1 lists the software image files that are available for the 08.0.30g release.
Table 1 Software image files
Device
Required Boot Image
Flash Image
FSX 800
FSX 1600
sxz10101.bin
SXLS08030g.bin (Layer 2) or
SXLR08030g.bin (full Layer 3)
Note: Load the image ONLY when the SX-
FI2XGMRXL6 2-port 10G and SX-FIZMRXL6
0-port management modules are installed
in the FSX chassis.
FCX
ICX 6610
grz10100.bin
FCXS08030g.bin (Layer 2) or
FCXR08030g.bin (Layer 3)
ICX 6430
ICX 6450
ICX 6430-C12*
ICX 6450-C12-PD
kxz10105.bin
ICX64S08030g.bin (Layer 2) or
ICX64R08030g.bin (Layer 3)
*Only available on Layer 2
ICX 6650
fxz10101.bin
ICXR08030g.bin
ICXS08030g.bin
ICX 7250
spz10105.bin
SPS08030g.bin (Layer 2) or
SPR08030g.bin (Layer 3)
ICX 7450
spz10105.bin
SPS08030g.bin (Layer 2) or
SPR08030g.bin (Layer 3)
ICX 7750
swz10105.bin
SWS08030g.bin (Layer 2) or
SWR08030g.bin (Layer 3)
PoE firmware files
Table 2 lists the PoE firmware file types supported in all 08.0.30 releases. The firmware files are
specific to their devices and are not interchangeable. For example, you cannot load FCX PoE
firmware on an FSX device.
Note: The PoE circuitry includes a microcontroller pre-programmed at the Brocade factory. In
the past, a copy of the current microcontroller code was embedded as part of the FastIron
software releases and was used for upgrades if necessary. Two different types of PoE controller
code sets were included for PoE and PoE+ subsystems. That is no longer the case, and the
software has been enhanced so that it can be loaded as an external file. The initial release of the
microcontroller code is still current and does not need to be upgraded. The PoE firmware version
FastIron Software Release 08.0.30g Release Notes 18
string will be kept updated to match the corresponding FastIron software version; however, this
is only a cosmetic change, and the firmware itself remains unchanged. If a new version of the
code is released, Brocade will notify its customers of the needed code upgrade. Finally, in the
remote case that a failure occurs during an upgrade process, the switch would still be functional
but without PoE circuitry. If you encounter such an issue, please contact Brocade Technical
Support.
Table 2 PoE firmware files
Device
Firmware version
File name
FSX 800 with SX-FI624P
module
FSX 1600 with SX-FI624P
module
6.0.6
fsx_poe_06.0.6.fw
FSX 800 with SX-FI48GPP or SX-
FI-24GPP module
FSX 1600 with SX-FI648PP or SX-
FI-24GPP module
2.1.0
fsx_poeplus_02.1.0.fw
FCX
ICX 6610
2.1.0
fcx_poeplus_02.1.0b004.fw
ICX 6430
ICX 6450
ICX 6430-C12
ICX 6450-C12-PD
2.1.0
2.3.09
icx64xx_poeplus_02.1.0b004.fw
icx64xxc12_poeplus_02.03.09.fw
ICX 7250
1.6.1 b009
icx72xx_poeplus_01.6.1.b009.fw
ICX 7450
1.6.1 b009
icx74xx_poh_01.6.1.b009.fw
Licensing information
The non-node locked license allows you to enable the licensed features prior to obtaining a license key.
The device no longer enforces the license key but prints syslog messages to the console, reminding the
user that a license is required. Once a valid license is installed, the messages stop. The non-node locked
license is applicable to a product platform. This means that a license can be moved from one device and
re-deployed to another device within the same product platform. The non-node locked license is not
specific to a device unlike the node-locked license, because the LID of a license is associated with each
device. This license can be purchased from Brocade. No activation process is required and these licenses
can be installed as received from Brocade.
Note the following change to the Brocade ICX 7250 Ports on Demand (PoD) licencing:
To upgrade all 8 PoD ports to 10G, you must already have the 2 port capacity license installed on
the device. If the 2 port capacity license is not already installed, you must purchase and install it
before you can install the 8 port capacity license.
FastIron Software Release 08.0.30g Release Notes 19
For a complete list of available software and port licensing, refer to the latest version of the FastIron
Ethernet Switch Software Licensing Guide on www.brocade.com or my.brocade.com.
System requirements
For system requirements, refer to the latest version of the FastIron Ethernet Switch Software Upgrade
Guide on www.brocade.com or my.brocade.com.
Configuration considerations
For configuration considerations, refer to the latest version of the FastIron Ethernet Switch Software
Upgrade Guide on www.brocade.com or my.brocade.com.
Limitations and restrictions
For limitations and restrictions, refer to the latest version of the FastIron Ethernet Switch Software
Upgrade Guide on www.brocade.com or my.brocade.com.
Upgrade and migration considerations
For upgrade and migration considerations, refer to the latest version of the FastIron Ethernet Switch
Software Upgrade Guide on www.brocade.com or my.brocade.com.
Upgrading to this release
For upgrade information, refer to the latest version of the FastIron Ethernet Switch Software Upgrade
Guide on www.brocade.com or my.brocade.com.
Downgrading to a previous release
For downgrade information, refer to the latest version of the FastIron Ethernet Switch Software Upgrade
Guide on www.brocade.com or my.brocade.com.
FastIron library
This section lists publications in the existing FastIron Release 08.0.30 library and new manuals available
to customers on http://www.brocade.com/ethernetproducts or my.brocade.com.
FastIron Software Release 08.0.30g Release Notes 20
Deliverables
Software manuals
Brocade FastIron SX, FCX, and ICX Diagnostic Reference
Brocade FastIron SX, FCX, and ICX Web Management Interface User Guide
FastIron Command Reference
FastIron Ethernet Switch Administration Guide
FastIron Ethernet Switch Feature Support, RFC Compliance, and IEEE Compliance Matrix
FastIron Ethernet Switch IP Multicast Configuration Guide
FastIron Ethernet Switch Layer 3 Routing Configuration Guide
FastIron Ethernet Switch Platform and Layer 2 Switching Configuration Guide
FastIron Ethernet Switch Security Configuration Guide
FastIron Ethernet Switch Software Defined Networking Configuration Guide
FastIron Ethernet Switch Software Licensing Guide
FastIron Ethernet Switch Software Upgrade Guide
FastIron Ethernet Switch Stacking Configuration Guide
FastIron Ethernet Switch Traffic Management Guide
Unified IP MIB Reference
Hardware manuals
Brocade FastIron SX Series Chassis Hardware Installation Guide
Brocade FCX Series Hardware Installation Guide
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide
Brocade ICX 6430-C Compact Switch Hardware Installation Guide
Brocade ICX 6450-C Compact Switch Hardware Installation Guide
Brocade ICX 6610 Stackable Switch Hardware Installation Guide
Brocade ICX 6650 Hardware Installation Guide
Brocade ICX 7450 Stackable Switch Hardware Installation Guide
Brocade ICX 7750 Hardware Installation Guide
FastIron Software Release 08.0.30g Release Notes 21
Hardware manuals
Brocade ICX 7250 Switch Hardware Installation Guide
Reporting errors in the guides
Send an e-mail to documentation@brocade.com to report errors in the user guides.
Contacting Brocade
Support
Contact your switch supplier for hardware, firmware, and software support, including product repairs
and part ordering. To expedite your call, have the following information immediately available:
Technical Support contract number, if applicable
Switch model
Switch operating system version
Error numbers and messages received
Detailed description of the problem, including the switch or network behavior immediately
following the problem, and specific questions
Description of any troubleshooting steps already performed and the results
Switch Serial Number
Getting technical help
To contact Brocade, go to http://www.brocade.com/services-support/index.page for the latest e-mail
and telephone contact information.
FastIron Software Release 08.0.30g Release Notes 22
Closed defects with code changes in Release 08.0.30g
This section lists defects closed with code changes in in the 08.0.30g release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000543666
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
ACLs - Access Control Lists
Symptom:
Control traffic to CPU is subjected to filtering.
Condition:
Egress ACL applied on VE and a port of VE is receiving control traffic bound to CPU. If the traffic
matches deny rule then the traffic will be dropped and not sent to CPU.
Workaround:
To the egress ACL, add a rule permitting traffic bound to CPU.
Defect ID:
DEFECT000552848
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.10
Technology:
HTTP/HTTPS
Symptom:
FI is exposed to CVE-2014-8730
Condition:
FI is exposed to CVE-2014-8730
Defect ID:
DEFECT000558899
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
SSH - Secure Shell
Symptom:
When SSH is done to VRRP-E, it shows in show who even afafter disconnection
Condition:
When SSH is done to VRRP-E, it shows in show who even afafter disconnection
Defect ID:
DEFECT000562548
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
ACLs - Access Control Lists
Symptom:
Control packets which are processed in Switch's CPU are also filtered by Egress Access-list applied
on a Virtual interface, even with egress-acl-on-cpu-traffic flag disabled.
Condition:
Egress ACL applied on Virtual interface, Control packets like OSPF Egresses out of the Virtual
interface.
egress-acl-on-cpu-traffic flag is not enabled.
Workaround:
Add an additional filter to permit the Source and/or Destination IP address of the control packet.
FastIron Software Release 08.0.30g Release Notes 23
Defect ID:
DEFECT000566505
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.40
Technology:
Configuration Fundamentals
Symptom:
On a 1G copper link between ICX7250 and FCX624S when FCX side is configured as "speed 1000-
full-master" and ICX7250 side is configured to "speed 1000-full-master" and then back to "speed
auto" then the link does not come up.
The FCX624S side is configured as "speed 1000-full-master" and the ICX7250 side is configured as
"speed auto", in that case the link remains up. Then the ICX7250 is configured as "speed 1000-full-
master", then the link goes down as expected. But when ICX7250 is configured back to "speed auto"
then the link does not come up.
Condition:
After having an invalid speed-duplex setting on the ICX 7250, and then changing it to auto, the link
appears to stay down. Even the port disable/enable does not recover the port. The peer end of 1G link
is FCX624S
Defect ID:
DEFECT000569369
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 07.4.00
Technology:
VLAN - Virtual LAN
Symptom:
High CPU observed for few seconds when disabling or enabling one end link in any of two 6450
switches (in scaled setup 2k VLANs) which are connected directly.
Condition:
In scaled setup (2k VLANs), processing VPORT down/up event holds CPU for few secs.So High
CPU will be seen for few seconds when disabling or enabling one end link in ICX 6450 switches.
.
Defect ID:
DEFECT000572533
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
OSPF - IPv4 Open Shortest Path First
Symptom:
Packets will get looped between two OSPF neighbors and the source would get ICMP-Error as TTL
expired.
Condition:
For an IP-address, static route is configured and an alternative route is learnt through OSPF for same
IP-address. The outgoing interface of static route is flapped.
Defect ID:
DEFECT000575351
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.10
Technology:
Configuration Fundamentals
Symptom:
High CPU utilization with SX 1600 chassis and "show chassis" displaying temperature as zero for
slots 12, 14, 16, 17 and 18
Condition:
This issue is seen with fully loaded SX 1600 and temperature read failing for slots 12, 14, 16, 17 and
18.
Recovery:
Reinsertion of line cards in slots 12, 14, 16, 17 and 18.
Defect ID:
DEFECT000575759
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
OSPFv3 - IPv6 Open Shortest Path First
Symptom:
In the Fastiron device, OSPFv3 hello timer does not reflect the value configured on the fly.
Condition:
When the hello interval timer is changed multiple times on the fly, the Fastiron device does not reflect
the confgiured value and sends more hello packets within one second.
FastIron Software Release 08.0.30g Release Notes 24
Defect ID:
DEFECT000577741
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
ACLs - Access Control Lists
Symptom:
In L3 FastIron device, a physical port configured with 'acl-logging' cannot be made member of a
VLAN without virtual-router interface.
Condition:
'acl-logging' command is configured on a physical interface and the port need to be made member of
a VLAN.
Defect ID:
DEFECT000580221
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
The Fastiron device acting as DHCP client is not getting the boot file with auto-configuration feature
enabled.
Condition:
When the Fastiron device acting as DHCP client is connected to the DHCP servers which needs the
client to specifically request for option 67 (boot file), the client is not getting the boot file.
Defect ID:
DEFECT000582687
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Management GUI
Symptom:
Port may flap when changing the port name through GUI web interface.
Condition:
Configuring port name through WEB interface.
Defect ID:
DEFECT000582755
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.20
Technology:
CLI - Command Line Interface
Symptom:
Stale SSH and Telnet connections after TCP connect scans
Condition:
SSH/TELNET to device with port scanner enabled and idle timeout configured
Recovery:
Reload of the device
Defect ID:
DEFECT000585403
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
ACLs - Access Control Lists
Symptom:
IPV6 egress ACL rules blocking ICMP packets and bringing OSPFv3 Neighbor ship down
Condition:
When device has OSPFv3 and IPV6 egress ACL configured, ICMP packets are blocked
Defect ID:
DEFECT000585440
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Management GUI
Symptom:
FI device may unexpectedly reload on WEB/HTTPS session logout.
Condition:
Web/HTTPS session logout or manually copying following configuration from file to CLI, where
extra space may be added to the contact or location.
snmp-server location VS-RZ1
snmp-server contact IT06-1
FastIron Software Release 08.0.30g Release Notes 25
Defect ID:
DEFECT000585864
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Management GUI
Symptom:
FI device may unexpectedly reload on stack priority change through HTTP.
Condition:
FI device managed by web interface and stack priority change from web interface.
Workaround:
Use CLI to modify stack priority
Defect ID:
DEFECT000586351
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Stack Failover/Switchover
Symptom:
Unable to get configuration mode in CLI using "config t" with following message.
telnet@T1-CORE-SW-ICX7750#conf t
Standby unit not ready yet, please try again.
Condition:
CLI Configuration mode can be unavailable in a stack after configuration update or image update.
Defect ID:
DEFECT000586571
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VLAN - Virtual LAN
Symptom:
The topology group ID greater than 30 is getting removed from the running configuration in
ICX6430.
Condition:
In ICX6430, the topology group ID greater than 30 is deleted from the configuration when upgrading
the code from 7.x to 8.x.
Defect ID:
DEFECT000586791
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
MCT - Multi-Chassis Trunking
Symptom:
MCT unable to synchronize the LACP configuration after the LAG is re-deployed and LACP stuck in
inactive or blocked state.
Condition:
Re-deploy MCT LACP to server
Defect ID:
DEFECT000586940
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
sFlow
Symptom:
In ICX 6650, unable to configure interface IP as source IP using "sflow source" CLI command.
telnet@ICX6650-1(config)#sflow source ve 20
Invalid input -> ve 300
Type ? for a list
telnet@ICX6650-1(config)#sflow source
DECIMAL UDP port number, Range: 1025-65535, Default is 8888
<cr>
Condition:
Configuring a virtual interface (VE) as the sFlow source interface in ICX 6650.
FastIron Software Release 08.0.30g Release Notes 26
Defect ID:
DEFECT000587072
Technical Severity:
Low
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
AAA - Authentication, Authorization,
and Accounting
Symptom:
RADIUS server receives ACCESS-REQUEST packet without NAS-PORT-ID attribute.
Condition:
FI device is configured to authenticate clients using RADIUS server and 802.1X or MAC-
authentication is enabled on a port..
Defect ID:
DEFECT000587488
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
In a stacking configuration with ICX 7450, the LAG ports for internal trunk to the stack member stays
down after reload.
Condition:
LAG ports of internal trunk to the stack member are stuck in block state on reload, after upgrade to FI
8.0.30e or FI 8.0.30f.
Defect ID:
DEFECT000587494
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
LLDP - Link Layer Discovery Protocol
Symptom:
FI device may unexpectedly reload when plugging/unplugging phone by LLDP.
Condition:
This issue may occur on FI device connected to a phone with LLDP
Workaround:
Remove "lldp enable snmp med-topo-change-notifications ports" configuration
Defect ID:
DEFECT000587698
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Unable to SSH/Telnet to SX device with all 5 sessions held up.
Condition:
SX device running on FI 8.0.30d with port scanner configured and SSH/telnet login, logouts.
Recovery:
Reload of the device.
Defect ID:
DEFECT000588652
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
After upgrading from FI 8.0.30d to FI 8.0.30f, the standby unit stuck in synchronizing state.
Condition:
Upgrade of stack from FI 8.0.30d to FI 8.0.30f and use of stack trunk ports.
Workaround:
Use 40G stack port instead of stack trunk ports.
Defect ID:
DEFECT000589675
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.30
Technology:
IPv4 Multicast Routing
Symptom:
The static rp-address configuration will be lost on code upgrade.
Condition:
When upgrading the system from 7.x to 8.x code, the static rp-address configuration will be lost.
Workaround:
After the upgrade, the static-rp address has to be reconfigured.
FastIron Software Release 08.0.30g Release Notes 27
Defect ID:
DEFECT000589972
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
RFN - Remote Fault Notification
Symptom:
'sh int br' shows 10G port in down instead of ERR-DIS state after loop-detection timer expiry.
Condition:
ICX 6450 with 10G port and loop detection enabled. The port state set to DOWN on loop detection
timer expiry.
Defect ID:
DEFECT000590055
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.30
Technology:
QoS - Quality of Service
Symptom:
ICX 6450 may unexpectedly reload when receiving continuous PAUSE frames after printing below
syslog message.
SYSLOG: <11>Dec 31 16:06:29 KH Dropping CPU TX packt due to buffer usage more than
95[5979]
Condition:
ICX 6450 running with FI 8.0.30d and continuous PAUSE frames are received with “buffer-sharing-
full” configured.
Workaround:
Remove the device sending continuous PAUSE frames
Recovery:
Recommendation:
1. Remove “buffer-sharing-full” configuration and use only when congestion is seen in network
2. Configure symmetric flow-control
Defect ID:
DEFECT000590179
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
ICMP - Internet Control Message
Protocol
Symptom:
When ICX7750 generates a Redirect, it contains the originating packet instead of forwarded packet.
Condition:
As per the RFC 4861, Section 8.2 "Redirected Header: as much of the forwarded packet as can fit
without the redirect packet exceeding the minimum MTU required to support IPv6, ICX7750 should
generate a Redirect which contains forwarded packet.
Defect ID:
DEFECT000590283
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IPv6 Addressing
Symptom:
The switch does not choose the source address that matches the longest prefix.
Condition:
As per the RFC 4861, "Rule 8: Use longest matching prefix", the device should select the source
address based on the longest prefix match.
Defect ID:
DEFECT000590858
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
BNA SNMP polling of FI device may cause the device to unexpectedly reload.
Condition:
FI device managed by BNA or SNMP query to fetch dot1dBasePortIfIndex (1.3.6.1.2.1.17.1.4.1.2 )
OID with the index value as 0 or out of port value.
FastIron Software Release 08.0.30g Release Notes 28
Closed defects with code changes in Release 08.0.30fa
This section lists defects closed with code changes in in the 08.0.30fa release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000587488
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
In a stacking configuration with ICX 7450, the LAG ports for internal trunk to the stack member stays
down after reload.
Condition:
LAG ports of internal trunk to the stack member are stuck in block state on reload, after upgrade to FI
8.0.30e or FI 8.0.30f.
Closed defects with code changes in Release 08.0.30f
This section lists defects closed with code changes in in the 08.0.30f release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000531662
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.10
Technology:
Configuration Fundamentals
Symptom:
SSH/TELNET to the FastIron device would fail after some days of device boot up.
Condition:
When the FastIron device is managed by NMS tool which does the periodic polling of the device
using SSH/TELNET, the SSH/TELNET connectivity would fail after some days of device boot up.
Defect ID:
DEFECT000561060
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.10
Technology:
ARP - Address Resolution Protocol
Symptom:
ICX 7750, observing varying forwarding rate at egress port.
Condition:
ICX 7750, traffic generated at a maximum load to all ingress ports causing congestion in egress port
and leads to varying forwarding rate at the egress port.
Defect ID:
DEFECT000561661
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.10
Technology:
Configuration Fundamentals
Symptom:
On ICX6610-48 after multiple cold boots, one of the 1G copper port does not link up.
Condition:
The ICX6610-48 has some of the 1G copper ports connected. These links are up. When we do
multiple cold boots of the system then sometime it was found that one of the copper port did not link
up.
Workaround:
When this port down condition happens then disabling and enabling the port will bring it back to
operational.
Recovery:
Cold Booting the device will clear the port issue.
FastIron Software Release 08.0.30g Release Notes 29
Defect ID:
DEFECT000564506
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IP Addressing
Symptom:
Some of traffic flows from lag ports will stop. Some streams will pass and some stream will not flow.
Condition:
If member port is the last member of the lag and that lag port is removed and then the traffic loss
happens in a multi VRF scenario.
Defect ID:
DEFECT000565407
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.10
Technology:
Configuration Fundamentals
Symptom:
On ICX6650 port having 1000Base-LX SFP optics, the interface type is displayed as unknown while
issuing "show media ethernet <port>" command. When the command "show media ethernet <port>"
is issued for the port having this optics then the "interface type unknown" is observed in the command
output.
Condition:
This issue is observed on ICX6650 having 1000Base-LX SFP optics when the CLI "show media
ethernet <port>" is issued.
Defect ID:
DEFECT000566348
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.10
Technology:
Configuration Fundamentals
Symptom:
In ICX6610, the 10G fiber port shows up before the system has completely initialized.
Condition:
The ICX6610 10G link shows as "Up" while the system is reloading.
Defect ID:
DEFECT000566388
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 07.4.00
Technology:
Traditional Stacking
Symptom:
ICX6610 may unexpectedly reload
Condition:
This issue may be seen when displaying virtual interfaces in detail using CLI command.
Defect ID:
DEFECT000570190
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.40
Technology:
IP Addressing
Symptom:
On ICX 7K routers, when ip follow is enabled on one vlan which follows a primary vlan, then hosts
in one vlan cannot communicate to hosts in another vlan.
Condition:
As long as ip follow is configured on ICX 7K routers.
Defect ID:
DEFECT000571052
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.10
Technology:
Rate Limiting and Shaping
Symptom:
Broadcast rate limiting on an interface is working as expected but when it comes to multicast rate
limiting or unknown unicast rate limiting it fails to drop exceeded rate.
Condition:
In ICX6XXX platforms, multicast and unknown unicast rate limit is not accurate.
Recovery:
none
FastIron Software Release 08.0.30g Release Notes 30
Defect ID:
DEFECT000571792
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
MCT - Multi-Chassis Trunking
Symptom:
External VRRP MAC address not showing on the correct port of ICX7750 MCT cluster after VRRP
failover
Condition:
This is seen on VRRP failover in MCT cluster.
Defect ID:
DEFECT000571946
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.30
Technology:
OpenFlow
Symptom:
Traffic through OPENFLOW enabled port, tagged to specific VLAN is sent out being tagged to
VLAN 4092.
Condition:
OpenFlow version 1 configured in passive mode on an ICX6610. When a port is tagged to a VLAN
and configured in layer23 mode, flows leaving that port leave tagged in VLAN 4092.
Defect ID:
DEFECT000572311
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.40
Technology:
ARP - Address Resolution Protocol
Symptom:
Ingress Gratuitous ARP on route-only lag port floods to other route-only ports.
Condition:
Observed when route-only configuration is given (Disabling L2 switching on an interface/globally)
Workaround:
No Workaround available
Defect ID:
DEFECT000572641
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
SSH - Secure Shell
Symptom:
Unable to SSH into client with DH Group14 Key
Condition:
When user tries to establish a SSH connection with DH group 14 key.
Defect ID:
DEFECT000572919
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
AAA - Authentication, Authorization,
and Accounting
Symptom:
AAA authentication not working for standby and member console.
Condition:
This issue is seen during Rconsole to standby or member unit.
Defect ID:
DEFECT000573664
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
On FastIron devices, when "radius-server retransmit" is configured as x then it is not transmitting x
times to radius-server.
Condition:
On FastIron devices, when "radius-server retransmit" is configured as x then it is not transmitting x
times to radius-server.
FastIron Software Release 08.0.30g Release Notes 31
Defect ID:
DEFECT000573719
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
VE Interface will become up if VE is disabled before IP address is assigned
Condition:
This issue can be seen when all interfaces in a VLAN is disabled and VE interface is assigned to
VLAN with disable on VE.
Defect ID:
DEFECT000574607
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
The SXL Active management module may unexpectedly reload.
Condition:
This issue can occur on flash update in management module through wr mem/SCP image update.
Defect ID:
DEFECT000574609
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Newly connected PDs do not power up.
Condition:
With PSE to PSE connected and PoE enabled, other PSE might get detected as PD and power gets
injected. This could cause the newly connected PDs to not power up.
Workaround:
User need to identify which port is being injected power and disable power from that PSE to this
port.
Recovery:
User need to identify which port is being injected power and disable power from that PSE to this port.
Defect ID:
DEFECT000574850
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
ACLs - Access Control Lists
Symptom:
When customer has the IPV6 TCP established ACL on the switch it still allows new TCP connections
for servers inside the network against dropping the connection.
Condition:
When port range is used while configuring the ACL, it is not applied on all the ports.
Defect ID:
DEFECT000576868
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VRP - VLAN Registration Protocol
Symptom:
With GVRP enabled on ICX6XXX devices and member ports from standby are not added to vlan as a
part of GVRP.
Condition:
When GVRP messages advertised to ports which are belongs to standby unit, FI ICX6XXX devices
do not process the control packets received on ports belongs to standby unit and standby unit ports
will not be included as member port to VLAN learnt through GVRP.
Defect ID:
DEFECT000577188
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.40
Technology:
VRP - VLAN Registration Protocol
Symptom:
After a Switch over, GARP Join timer is not started for sending advertisement messages when the
standby becomes active. This results in dynamic VLAN membership to be broken in FI devices.
Condition:
After Switch over in FI stacking setup, new active unit will not send GVRP advertisement messages.
FastIron Software Release 08.0.30g Release Notes 32
Defect ID:
DEFECT000577663
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VLAN - Virtual LAN
Symptom:
L2 control packets and ARP packets are getting flooded while receiving it on the route-only enabled
interface(route-only is configured on interface level).
Condition:
Flooding of L2 control packets and ARP packets is not prevented when the packets received on
interface which is configured as route-only interface using interface level command.
Defect ID:
DEFECT000578131
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
MCT - Multi-Chassis Trunking
Symptom:
ICX6650 running MCT may send traffic learnt via CCEP ports back to the same CCEP ports back to
the originating switch.
Condition:
ICX6650 running MCT may send traffic learnt via CCEP ports back to the same CCEP ports back to
the originating switch.
Defect ID:
DEFECT000578458
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
DOT1X authentication failed port, sends tagged frames when authenticated later.
Condition:
This issue is seen when DOT1x authentication is enabled and port is re-authenticated after
authentication failure.
Defect ID:
DEFECT000579231
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.40
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
The DHCP client is disabled automatically after write memory and reload.
Condition:
When the DHCP client is assigned only with dynamic domain-name and DNS server and not
statically, then the reload after write memory disables the DHCP client automatically.
Defect ID:
DEFECT000580689
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
User does not get authenticated after standby reloads
Condition:
When standby reloads and stops at boot prompt in a 2 unit stack
Defect ID:
DEFECT000580819
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Some specific vendor PDs gets to overload state
Condition:
Upon reload of the PD
FastIron Software Release 08.0.30g Release Notes 33
Defect ID:
DEFECT000581134
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
MAC Port-based Authentication
Symptom:
The device may unexpectedly reload when MAC authentication entry is removed due to aging.
Condition:
MAC-Authentication fails for client and the hardware entry removed due to aging.
Defect ID:
DEFECT000581303
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
New clients are unable to get authenticated by 802.1X authentication method.
Condition:
MAC-authentication and 802.1X authentications are enabled on an interface. First client fails with
MAC-authentication and authenticated successfully through 802.1X with dynamic VLAN. Further
clients are unable to authenticate using 802.1X.
Defect ID:
DEFECT000581476
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
MRP - Metro Ring Protocol
Symptom:
High CPU utilization seen when adding VLANs to MRP topology group causing OSPF flaps.
Condition:
This issue is seen when adding member VLAN to topology group
Defect ID:
DEFECT000581556
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
MRP - Metro Ring Protocol
Symptom:
MRP-failover after bringing up an interface in the MRP-ring, causing the MRP to temporary loop
Condition:
MRP-failover after bringing up an interface in the MRP-ring
Defect ID:
DEFECT000581643
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
Device may unexpectedly reload when a client moves from authentication enabled interface to
another interface.
Condition:
Client is authenticated by MAC-Authentication and 802.1X methods. The client moves to another
interface.
Defect ID:
DEFECT000582390
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
Cisco 2600 APs not working after upgrade to FI 08.0.30d
Condition:
Upgrade of devices to FI 08.0.30d connected with Cisco 2600 AP
Defect ID:
DEFECT000582397
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
The device may unexpectedly reload when 802.1X client tries authentication. .
Condition:
MAC-authentication and 802.1X are enabled on interface. A client tries to do 802.1X authentication.
FastIron Software Release 08.0.30g Release Notes 34
Defect ID:
DEFECT000582668
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
Device may unexpectedly reload when unplugging PC behind phone using flex authentication.
Condition:
A client is 802.1X authenticated and when the 802.1X client logs-off, this issue can be hit.
Defect ID:
DEFECT000582971
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.30
Technology:
Rate Limiting and Shaping
Symptom:
Rate limiting happens on unknown-unicast and multicast without broadcast rate limiting.
Condition:
In ICX6430-C12 device with broadcast rate limiting removed from configuration, rate limiting is
incorrectly being applied to unknown unicast, multicast and broadcast traffic.
Defect ID:
DEFECT000583153
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
802.1X session put in restricted VLAN with state "permit".
Condition:
MAC-Authentication and 802.1X are enabled on interface. For a client which is not capable of
sending 802.1X packet, MAC-Authentication fails and the client moves to restricted VLAN.
Defect ID:
DEFECT000583206
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
A client is authenticated by MAC-Authentication with T:<VLAN> and it gets 802.1X authenticated
with U:<VLAN> where <VLAN> is same VLAN-ID. The client's access is blocked. After the session
ages-out, the interface is not removed from the dynamic VLAN.
Condition:
MAC-Authentication and 802.1X are enabled on interface. MAC-authentication is successful with
T:VLAN and 802.1X fails.
Defect ID:
DEFECT000583502
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Software Installation & Upgrade
Symptom:
1G SX and LX SFP inserted ports will be down after upgrading to 8.0.30e on ICX7450.
Condition:
Upgrade of ICX7450 to 8.0.30e with 1G SX and LX SFP inserted.
Defect ID:
DEFECT000583812
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Software Installation & Upgrade
Symptom:
The device may unexpectedly reload while adding ports to a VLAN with "tagged or untagged"
command option and more number of interfaces added to CLI command.
Condition:
The issue will be seen while adding ports to a VLAN with "tagged or untagged" command option
and more number of interfaces added to CLI command.
FastIron Software Release 08.0.30g Release Notes 35
Defect ID:
DEFECT000584814
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Stack Management
Symptom:
Following error gets printed on the console. Doesn't have any functional impact.
Error: Module 256 is not a POE module
Condition:
Following error gets printed on the console. Doesn't have any functional impact.
Error: Module 256 is not a POE module
Defect ID:
DEFECT000584820
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
The VOIP phone will be detected as Non-PD device.
Condition:
When the POE interface is disabled and enabled, the phone will be detected as Non-PD device.
Defect ID:
DEFECT000584829
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
802.1X and MAC-Authentication are enabled on interface. If client sends traffic without sending
802.1X packet. The client fails MAC-Authentication and remains in blocked state. When client tries
802.1X authentication, the client is not authenticated and remains in blocked state forever.
Condition:
802.1X and MAC-Authentication are enabled on interface. When client fails MAC-authentication and
it tries 802.1X authentication.
Defect ID:
DEFECT000585493
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
Cisco 7960 phone connected to the standby unit is detected as Non-PD.
Condition:
When non-pd-detection is enabled in ICX7450, the Cisco phone connected to the standby unit is
detected as Non-PD device.
Defect ID:
DEFECT000585518
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
Power is allocated to the Non-PD device connected to the POE port.
Condition:
When non-pd-detection is enabled, failed to detect Non-PD device connected to the POE port.
Defect ID:
DEFECT000585578
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
PoE/PoE+ - Power over Ethernet
Symptom:
A valid PD device is detected as Non-PD when it is connected to the primary port of the LAG.
Condition:
When non-pd-detection is enabled, the valid PD device connected to the primary port is detected as
Non-PD.
FastIron Software Release 08.0.30g Release Notes 36
Defect ID:
DEFECT000585652
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
On ICX6450 and ICX6610 devices, secondary port of the LAG is not set to disabled state while
removing it from LAG and results in a loop.
Condition:
Removing secondary port from LAG in ICX6450 and ICX6610 devices.
Closed defects with code changes in Release 08.0.30e
This section lists defects closed with code changes in in the 08.0.30e release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000522975
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.10
Technology:
Configuration Fundamentals
Symptom:
"pscp scp Fatal: Received unexpected end-of-file from server" failure message during file transfer
using SCP.
Condition:
This issue may be seen when transferring a file over SCP using Putty version 0.63 on a slow
connection.
Defect ID:
DEFECT000536867
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
Increased Multicast and Broadcast traffic on active unit failover in the stack
Condition:
Failover in a ring topology.
Recovery:
The traffic surge settles after stack merge is complete
Defect ID:
DEFECT000545995
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Stack Failover/Switchover
Symptom:
During a failover on the Brocade ICX 7450-48 stack in ring topology, a transient loop is detected by
loop-detect protocol resulting in CCEP port on MCT going to Error Disabled state.
Condition:
MCT with loop-detect enabled and stack failover of the CCEP client
Recovery:
Clear loop detection in this state or configure auto error recovery
Defect ID:
DEFECT000554394
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.10
Technology:
Hardware Monitoring
Symptom:
An error message is displayed while configuring 100-fx without installing any optics.
Condition:
When configuring 100-fx command without installing an optics on the device.
FastIron Software Release 08.0.30g Release Notes 37
Defect ID:
DEFECT000555792
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.20
Technology:
SSH - Secure Shell
Symptom:
When performing SSH with X11 forwarding option, the connection gets disconnected immediately.
Condition:
Initiate SSH session with X11 forwarding option.
Defect ID:
DEFECT000555878
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.10
Technology:
BGP4+ - IPv6 Border Gateway Protocol
Symptom:
In ICX7750 device BGP hold timer expires and IPv6 BGP peer bounces regularly.
Condition:
BGP flap is observed when DOS attack with TCP source port 0 is received.
Defect ID:
DEFECT000563359
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.00
Technology:
System
Symptom:
he Brocade ICX 6610 device reloads unexpectedly with the following error message. "EXCEPTION
1200, Data TLB error".
Condition:
Some of the Brocade ICX 6610 switches reload due to data memory exception.
Defect ID:
DEFECT000563782
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.10
Technology:
Rate Limiting and Shaping
Symptom:
If the inbound rate limit defined for 10G port is greater than 1G, it is removed from the running
configuration after reload.
Condition:
If a 10G port has an inbound rate limit defined that is greater than 1G
Defect ID:
DEFECT000565933
Technical Severity:
Low
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.10
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
bgp4V2PeerAdminStatus ( .1.3.6.1.4.1.1991.3.5.1.1.2.1.12) reports as running (2) with BGP neighbor
administratively shutdown
Condition:
When BGP neighbor is administratively brought down and bgp4V2PeerAdminStatus is polled using
SNMP, the bgp4V2PeerAdminStatus ( .1.3.6.1.4.1.1991.3.5.1.1.2.1.12).
Defect ID:
DEFECT000571971
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.30
Technology:
System
Symptom:
In ICX7250 unit, even if the 1G copper port speed is configured as 100Mbps Full duplex using the
speed-duplex 100-full command, the port comes up in 100Mbps Half duplex mode after system
reload.
Condition:
This problem happens on ICX7250 unit with 1G copper port when it is configured in 100-Full mode
and system is reloaded after saving the configuration.
FastIron Software Release 08.0.30g Release Notes 38
Defect ID:
DEFECT000572395
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
SNMP walk on the management interface stops working and the CPU UDP traffic gets dropped.
Condition:
This issue is seen when adding a default route to the management VRF with SNMP walk on the
management interface.
Recovery:
The following CLI is added to allow SNMP walk on Management interface to respond out of the
Management interface instead of looking at the routing table available in FI 8.0.30e and later releases:
[no ] ip follow-ingress-vrf
By default, the CLI is not enabled. Once configured, it can be turned off by disabling.
Defect ID:
DEFECT000572496
Technical Severity:
Critical
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
ICMP- Internet Control Message
Protocol
Symptom:
IPv6 ping and IPv6 traffic not working/flowing.
Condition:
IPv6 routing is configured and IPv6 premium license is not installed.
Workaround:
Install IPv6 premium license on box.
Defect ID:
DEFECT000574413
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
VLAN - Virtual LAN
Symptom:
In FastIron device, MDNS traffic floods the VLAN even when uplink switch-port command is
enabled.
Condition:
When the uplink switch-port command is configured, all unregistered multicast traffic floods the
VLAN rather than sending only to the uplink ports.
Workaround:
Enabling ip multicast active at global level will result in sending traffic only to uplink ports.
Defect ID:
DEFECT000574663
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.40
Technology:
Traditional Stacking
Symptom:
The stack secure-setup command fails to discover stack units.
Condition:
Configure default-ports 1/2/1 1/2/3 without reload.
Defect ID:
DEFECT000575501
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
Traffic loops in network with ICX stack
Condition:
When active unit failover or any condition that causes stack link to flap in a Ring topology
FastIron Software Release 08.0.30g Release Notes 39
Defect ID:
DEFECT000575539
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.30
Technology:
QoS - Quality of Service
Symptom:
DSCP based QOS is not working after reload of FastIron Device
Condition:
Once the FastIron device is reloaded, the DSCP related QOS is not working.
Defect ID:
DEFECT000576356
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.30
Technology:
System
Symptom:
Non-standard PDs operating with alternate A configuration alone does not get powered on ICX7450
PoH ports (ports 1 to 8).
Condition:
Non-standard PDs operating with alternate A configuration alone does not get powered on ICX7450
PoH ports (ports 1 to 8).
Workaround:
Connect these kind of PDs from port 9 to 24/48
Defect ID:
DEFECT000577092
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
Device may unexpectedly reload.
Condition:
During authentication, RADIUS returns a tagged VLAN and ACL ID. Authentication fails as the
RADIUS-assigned ACL ID is non-existent on the device and subsequently the user is blocked. The
device attempts reauthentication of the client, which again fails due to non-existent ACL ID. After a
few reauthentication attempts, the device reloads unexpectedly.
Defect ID:
DEFECT000577830
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.30
Technology:
OpenFlow
Symptom:
Push VLAN (adding VLAN tag) and pop VLAN do not work on ARP packets although the packet
hits the openflow rule.
Condition:
For ARP Packet with Rule to push VLAN (adding VLAN tag) or pop VLAN.
Defect ID:
DEFECT000579284
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
LAG goes down on upgrade from FI 8.0.30b to FI 8.0.30d.
Condition:
This issue is seen on upgrade from FI 8.0.30b to FI 8.0.30d on device with LAG configured.
Defect ID:
DEFECT000579899
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
IP Multicast
Reported In Release:
FI 08.0.30
Technology:
PIM - Protocol-Independent Multicast
Symptom:
The FastIron device unexpectedly reloads while processing PIM PRUNE packet.
Condition:
This issue is seen with MCT & L3 Multicast configuration and processing for PIM PRUNE packet.
FastIron Software Release 08.0.30g Release Notes 40
Defect ID:
DEFECT000579918
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
A stack unit and the directly connected stack units reload unexpectedly.
Condition:
When a client which is not a dot1x-capable tries to authenticate using MAC authentication on a stack
where both 802.1X authentication and MAC authentication are configured, the stack unit and the
directly connected stack units reload unexpectedly.
Defect ID:
DEFECT000580196
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
The client which is not a dot1x-capable is not moved to the restricted VLAN upon MAC
authentication failure.
Condition:
When both MAC authentication and 802.1X authentication are enabled, the client which is not a
dot1x-capable is not moved to the restricted VLAN upon MAC authentication failure.
Closed defects with code changes in Release 08.0.30d
This section lists defects closed with code changes in in the 08.0.30d release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000543961
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.20
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
In ICX7750 devices, the DHCP client does not refresh the dynamically obtained DNS server and
domain names from DHCP server after reboot.
Condition:
The issue happens in ICX7750 DHCP client when moved to another DHCP server which provides
different DNS server and domain names.
Defect ID:
DEFECT000545454
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Hardware Monitoring
Symptom:
While configuring ipv6 address for the first time, we get the following error message:
sil_sp_eth_program_mac_address: Unable to program multicast MAC errno 1
And after this, the error messag appears during every reload.
Condition:
When the IPv6 address is configured for the first time
Workaround:
There is no workaround for this problem
FastIron Software Release 08.0.30g Release Notes 41
Defect ID:
DEFECT000546727
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.20
Technology:
LAG - Link Aggregation Group
Symptom:
The FastIron device, does not provide a warning or any graceful solution during dynamic LAG
misconfiguration or mis-cabling scenarios instead the links go into blocking state in one of the
partner.
Condition:
This issue happens only when there is a mis-configuration in dynamic LAG or any mis-cabling.
Defect ID:
DEFECT000557757
Technical Severity:
High
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.20
Technology:
Stack Failover/Switchover
Symptom:
MAC hardware entry mismatch in standby or member unit with active unit, when stack active device
was powered-off.
Condition:
With continuous traffic to a stack device, the active unit is powered off or reloads.
Recovery:
'clear mac-address' on the current active unit resolves the MAC entry mismatch issue.
Defect ID:
DEFECT000558557
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
MRP - Metro Ring Protocol
Symptom:
CPU utilization goes to 99% during MRP failover. Telnet/console session freezes on all the member
nodes.
Condition:
The issue will be seen when configuring topology group with more number of VLANs and MRP is
enabled on topology group.
Defect ID:
DEFECT000559207
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.10
Technology:
sFlow
Symptom:
SFlow samples are not received from FI device which has BGP routing feature enabled.
Condition:
SFlow and BGP and enabled on an FI device.
Defect ID:
DEFECT000560120
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.10
Technology:
QoS - Quality of Service
Symptom:
The device may unexpectedly reload when receiving continuous PAUSE frames.
Condition:
This issue can be encountered when continuous PAUSE frames are received by the device and flow
control is enabled in RX.
Defect ID:
DEFECT000560145
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IP Addressing
Symptom:
Customer will notice traffic drop and ARP is not resolved
Condition:
Two steps
1. delete the default ve inteface (the underlying vlan has the lag ports)
2. config ip address on the lag
FastIron Software Release 08.0.30g Release Notes 42
Defect ID:
DEFECT000560805
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IP Addressing
Symptom:
Route debug command prints only first few lines and repeats the same output until the operation is
aborted.
Condition:
Inappropriate output upon execution of the route debug command.
Defect ID:
DEFECT000561233
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
Static Routing (IPv4)
Symptom:
While performing Traceroute to IP-address in non-default VRF, ICMP-Error response is received
from an IP-address in default VRF.
Condition:
Ingress port is tagged to multiple VLANs and few of the VLANs are in non-default VRF.
Defect ID:
DEFECT000562036
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 07.4.00
Technology:
Traditional Stacking
Symptom:
Standby Unit [2] freezes after two weeks running successfully.
Condition:
This issue can be seen with a two unit ICX6610 stack running 7.4.00j code and DHCP snooping
enabled.
Defect ID:
DEFECT000562558
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Other
Reported In Release:
FI 08.0.30
Technology:
Other
Symptom:
When the ICX7450-48F connected to edge switches (Cisco SF-102) then the link does not come up.
Cisco switch sees the link but Brocade does not see the link
Condition:
When the ICX7450-48F connected to edge switches (Cisco SF-102) then the link does not come up.
Cisco switch sees the link but Brocade does not see the link
Defect ID:
DEFECT000562730
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.10
Technology:
BGP4 - IPv4 Border Gateway Protocol
Symptom:
BGP connections in down state with TCP send buffer leak.
Condition:
When BGP neighbors flap over a period of time like 90 to 180 days leading to TCP send buffer leak.
Defect ID:
DEFECT000562755
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
Trunk deploy fails during boot up.
Condition:
This issue is seen on system boot with LAG configured on 10G/1G dual-speed port where the port is
configured as 1G.
FastIron Software Release 08.0.30g Release Notes 43
Defect ID:
DEFECT000563550
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 07.3.00
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
Device may unexpectedly reload when polling IPv6IfEntry MIB, which has null value.
Condition:
SNMP polling of IPv6IfEntry MIB on a device configured as switch.
Workaround:
Disable SNMP IPv6 MIB polling.
Defect ID:
DEFECT000564096
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Following POE warning message displayed in the session
"M:poe S:status L:0 - Illegal PoE power request of 0 mW in CDP/LLDP message on port. Request
ignored."
Condition:
This issue is seen on power negotiation with the POE device after reload.
Defect ID:
DEFECT000564256
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Plugging a 7450 switch port (mdix) into another 7450 switch port (mdix) (same switch) with a
straight through cable their link keeps up
Condition:
Plugging a 7450 switch port (mdix) into another 7450 switch port (mdix) (same switch) with a
straight through cable
Defect ID:
DEFECT000564301
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.20
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
On SNMP-GET request or SNMP-GETNEXT request, device fails to respond for the MIB objects
under the snVrrp.
Condition:
This issue is seen when polling for SnVrrp MIB objects using SNMP.
Defect ID:
DEFECT000564379
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.10
Technology:
System
Symptom:
CPU utilization spikes to 99% when speed-duplex 1000-full-master is configured on ports ICX6450
ports 1/2/1 to 1/2/4 with copper SFP connected there
Condition:
When speed-duplex 1000-full-master is configured on ports ICX6450 ports 1/2/1 to 1/2/4 with copper
SFP connected there
FastIron Software Release 08.0.30g Release Notes 44
Defect ID:
DEFECT000564431
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 07.3.00
Technology:
System
Symptom:
On ICX6610 device the couple of 1G copper port connected to device is goes down.
Condition:
In one of the ICX6610 device the couple of 1G copper ports were connected to device suddenly went
into DHCP discover mode.
Defect ID:
DEFECT000564553
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Hardware Monitoring
Symptom:
On ICX7750-48C when the "dm diagnostics" test is run then the Packet Line Rate test in the test suite
fails for port no 1/1/1 to 1/1/48.
Condition:
When the "dm diagnostics" test is run on ICX7750-48C unit then the Packet Line Rate test in the test
suite fails for port no 1/1/1 to 1/1/48
Defect ID:
DEFECT000564583
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.30
Technology:
System
Symptom:
On ICX7250-48P unit during reload the error message "Skipping bad block error" is observed. On
reload the following message appears on console:
NAND read: device 0 offset 0x4000000, size 0x2000000
....................................................Skipping bad block 0x05a0000
0
Skipping bad block 0x05b00000
............ 33554432 bytes read: OK
Condition:
The skipping bad block error message appear during unit reload for ICX7250-48P
Recovery:
There is no functional impact due to these error
Defect ID:
DEFECT000565380
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Hardware Monitoring
Symptom:
Continuous scrolling of error messages "I2C_ioctl failed: bus 1, dev 0x51, errno 121" when entering
config mode on ICX7450 stack.
Condition:
This issue is seen when non-Brocade SFPs with Serial number eTBFP343-FSL10 is used in FI
devices.
Defect ID:
DEFECT000565422
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.01
Technology:
System
Symptom:
The ‘link-config gig’ command does not get applied to non-primary ports of a LAG after reload in the
ICX6430 device.
Condition:
This issue is observed on ICX6430 switch on the non primary LAG ports. When the ‘link-config gig’
command is provided for LAG ports and system is reloaded then after reload this command does not
get applied to non-primary ports of a LAG
FastIron Software Release 08.0.30g Release Notes 45
Defect ID:
DEFECT000565551
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
MAC Port-based Authentication
Symptom:
Even though a MAC address is already authenticated through MAC-authentication, traffic from the
MAC address is rejected on new VLANs with reason 'Maximum Limit reached'.
Condition:
Mac-authentication is enabled on an interface and the interface has clients sending traffic in multiple
VLANs.
Defect ID:
DEFECT000565780
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
BPDU Guard - Bridge Protocol Data
Unit
Symptom:
RSTP convergence takes more than 1 second
Condition:
This issue is seen on a device with RSTP configured and device not updating the agreement flag in
the BPDU on the alternate role.
Defect ID:
DEFECT000565808
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
Security Vulnerability
Symptom:
The Fastiron devices will reload when running NMAP scan.
Condition:
When NMAP scan is run continuously, then the Fastiron devices will reload unexpectedly.
Defect ID:
DEFECT000565922
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
SSH - Secure Shell
Symptom:
Customer is not able to establish new SSH/TELNET session after couple of days.
Condition:
The issue is because of port scanning or BNA polling. During port scanning process, the established
child task is not closed and it cause the problem in new child task creation.
Defect ID:
DEFECT000566336
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
ICX7450 4x10G Copper Port LED goes OFF when the link is UP.
Condition:
When the port-speed is set to 1000-full, ICX7450 4x10G Copper Port LED goes OFF even though the
link is UP.
Defect ID:
DEFECT000567010
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.10
Technology:
OSPF - IPv4 Open Shortest Path First
Symptom:
FI device will be reloaded when OSPF is enabled with ACL deny rule.
Condition:
When OSPF is enabled with ACL rule to hit its own OSPF interface IP addresse, FI device will be
reloaded.
Workaround:
ACL rule can be modified to permit its own OSPF interface IP addresses and deny others.
FastIron Software Release 08.0.30g Release Notes 46
Defect ID:
DEFECT000567117
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 07.4.00
Technology:
IP Addressing
Symptom:
The device may unexpectedly reload with DHCP snooping enabled.
Condition:
This issue may be seen when the device has many pending ARP entries with DHCP snooping enabled
on the device.
Workaround:
Turn off DHCP snooping.
Defect ID:
DEFECT000567173
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.30
Technology:
Rate Limiting and Shaping
Symptom:
In ICX7250, the traffic loss is observed with rate-shaping configuration after the switch reload.
Condition:
The rate-shaping is configured on a ICX7250 switch and 6-queue traffic is running clean. After
switch is reloaded and traffic is restarted, observed 50% traffic loss for queue-0 traffic which is close
to 10% of interface bandwidth.
Defect ID:
DEFECT000568464
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
ACLs - Access Control Lists
Symptom:
Configuration of MAC filter on dual-mode port interface fails.
Condition:
MAC filter configuration on a dual-mode port.
Defect ID:
DEFECT000568642
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
MRP - Metro Ring Protocol
Symptom:
High CPU utilization seen when adding VLANs to MRP topology group causing OSPF flaps.
Condition:
This issue is seen when adding member VLAN to topology group
Defect ID:
DEFECT000569609
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
SSH - Secure Shell
Symptom:
Sometime the user is unable to establish a SSH session with the device.
Condition:
This issue can be seen on login/logout of SSH with one or more NMAP port scanning on the device.
Recovery:
Reboot the device
Defect ID:
DEFECT000569613
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
MAC Port-based Authentication
Symptom:
LLDP med policy shows default information after RADIUS server assigns LLDP med dynamically
Condition:
This issue is seen when radius server assigns LLDP med dynamically to the connected phone.
FastIron Software Release 08.0.30g Release Notes 47
Defect ID:
DEFECT000569749
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.30
Technology:
OpenFlow
Symptom:
FI Device reboots spontaneously while removing a rule from flow table using openflow controller.
Condition:
Openflow controller sends command to FI device for removing a rule from flow table.
Defect ID:
DEFECT000570318
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.20
Technology:
802.1x Port-based Authentication
Symptom:
Statically authenticated dot1x-client is authorized on VLAN 4092.
Condition:
First DOT1X client is authenticated on a VLAN assigned by RADIUS. Second DOT1X client is
statically authenticated on VOICE-VLAN.
Defect ID:
DEFECT000570454
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.10
Technology:
System
Symptom:
Brocade 6430-C12 devices stop offering power to connected Meru AP320/AP320i devices.
Condition:
This issue may occur when Brocade 6430-C12 is connected to Meru AP320/AP320i devices.
Defect ID:
DEFECT000570822
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VRP - VLAN Registration Protocol
(GVRP, MMRP, MVRP)
Symptom:
Intermittent network connectivity observed after core device is reloaded.
Condition:
This issue can be seen on ICX7450/7250/7750 connected to multiple edge stacks with 2 port LAG
and GVRP configured.
Defect ID:
DEFECT000571029
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
No warning message is displayed when a flexauth configuration is expected to overwrite existing
configuration
Condition:
When "dot1x auth-filter x x" is given when an existing config of "dot1x auth-filter 1" is already
present
Defect ID:
DEFECT000571045
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
Authenticated clients are wrongly placed into global auth-def-vlan
Condition:
This issue is seen when dot1x auth-filter is configured to bypass dot1x authentication and classify the
Clients into local auth-def-vlan.
And there is auth-default-vlan configured at interface level. But when dot1x client is authorized by
dot1x auth-filter, it is wrongly authorized in the global auth-default-vlan.
FastIron Software Release 08.0.30g Release Notes 48
Defect ID:
DEFECT000571767
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
In switch image, mac-auth is not working properly for Dot1xNotCapable Clients.
Condition:
This issue is seen with switch image and mac-authentication is enabled.
Defect ID:
DEFECT000571832
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
Ports default spanning tree state is incorrect.
Condition:
when we un-configure a peer-info on a dynamic lag.
Defect ID:
DEFECT000571848
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
When port receives LACP PDU with information that does not match with the configured peer info,
sometime system does not bring this port into mis-match error state.
Condition:
When the configured peer information's system priority is different from the peer information
contains in the LACP PDU while the system mac and LACP key are both match.
Defect ID:
DEFECT000572014
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
Standby unit may unexpectedly reload when configuring peer-info on a dynamic LAG.
Condition:
This issue can be seen when configuring peer-info on a dynamic LAG
Defect ID:
DEFECT000572119
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
Switch may unexpectedly reload when trying to authenticate the dot1x client behind the phone.
Condition:
Switch tries to authenticate the dot1x client behind the phone.
Defect ID:
DEFECT000572534
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
All lag ports are moving to forwarding state even if some of the lag member ports should be blocking.
Condition:
After dynamic lag is deployed, all lag ports are moving to forwarding state even though some of the
ports are at mis-cabling error condition.
Defect ID:
DEFECT000572952
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
SNMP walk on ISO MIB stops in snRIP table.
Condition:
This issue is seen on SNMP walk of ISO MIB or snRIP table.
FastIron Software Release 08.0.30g Release Notes 49
Defect ID:
DEFECT000572992
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
AAA - Authentication, Authorization,
and Accounting
Symptom:
Console will be locked during reload when Accounting is turned on for radsec.
Condition:
Console will get blocked with radsec when Accounting is turned on
Defect ID:
DEFECT000573164
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Licensing
Symptom:
Licence validity is displayed as "compliant" even after the expiry of the trial the license.
Condition:
Even when trial license is expired, the validity of the NNLL license is shown as "complaint"
Defect ID:
DEFECT000573249
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
DHCP OFFER being sent to incorrect MAC address
Condition:
When the unicast bootp flag is set, the relay agent forwards the offer packet based on the entry in the
ARP table.
This issue is seen when host B sends a DISCOVER packet after host A has acquired an IP address
and releases the IP address.
Workaround:
Clear ARP on the relay agent.
Defect ID:
DEFECT000573308
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
Dot1x authenticated port loses connectivity when configuration changes made on another dot1x port
Condition:
When dot1x is enabled on two ports then VLAN membership for these ports in hardware should be
untagged. But if dot1x is disabled on any one of the port then the VLAN membership of the other port
changed to tagged from untagged. This causes the switch to send tagged frame when ping comes from
outside the switch to the PC and hence connectivity loss issue is reported.
Defect ID:
DEFECT000574066
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VRP - VLAN Registration Protocol
(GVRP, MMRP, MVRP)
Symptom:
Unable to deploy LAG on un-deploy and deploy, with GVRP enabled and VLAN entries are
dynamically learnt.
Condition:
This issue is seen when GVRP is enabled in LAG interface and LAG is un-deployed and deployed
with VLAN entries dynamically learnt.
FastIron Software Release 08.0.30g Release Notes 50
Defect ID:
DEFECT000574131
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VRP - VLAN Registration Protocol
(GVRP, MMRP, MVRP)
Symptom:
When receiving LeaveAll message on STP blocked port, it does not transmit Empty message to peer
applicant for sending re-declaration of the registered attributes. So STP blocked port is getting
removed/added to GVRP VLAN continuously and error messages printed in console.
Condition:
The VLAN addition/deletion error message will be seen in console when the VLAN is learnt through
only STP blocked port as tagged member port. When the GVRP VLAN has other ports also member
ports, STP blocked port add or removal only happen and no logs will be printed.
Defect ID:
DEFECT000574769
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
MAC Port-based Authentication
Symptom:
"voice-vlan <VLAN-ID>" command is configured on the switch. After "write memory" and reload,
the "voice-vlan" command is not available in the running configuration.
Condition:
Reload after saving "voice-vlan <VLAN-ID>" command to startup configuration.
Defect ID:
DEFECT000575275
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
MAC Port-based Authentication
Symptom:
'stp-bpdu-guard' does not take effect when mac-auth is enabled
Condition:
This issue is seen in ICX6610, ICX6650, ICX6450 and FCX devices with MAC authentication
enabled and applying 'stp-bpdu-guard'.
Defect ID:
DEFECT000575664
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.40
Technology:
System
Symptom:
The mdi-mdix setting does not work correctly on ICX7450 when the "mdi-mdix mdi" command is
followed by "speed-duplex 1000-full-master" command
Condition:
When the "mdi-mdix mdi" command is issued followed by "speed-duplex 1000-full-master"
command
Defect ID:
DEFECT000558557
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
MRP - Metro Ring Protocol
Symptom:
CPU utilization goes to 99% during MRP failover. Telnet/console session freezes on all the member
nodes.
Condition:
The issue will be seen when configuring topology group with more number of VLANs and MRP is
enabled on topology group.
Defect ID:
DEFECT000559207
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.10
Technology:
sFlow
Symptom:
SFlow samples are not received from FI device which has BGP routing feature enabled.
Condition:
SFlow and BGP and enabled on an FI device.
FastIron Software Release 08.0.30g Release Notes 51
Defect ID:
DEFECT000560145
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IP Addressing
Symptom:
Customer will notice traffic drop and ARP is not resolved
Condition:
Two steps
1. delete the default ve inteface (the underlying vlan has the lag ports)
2. config ip address on the lag
Defect ID:
DEFECT000560805
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
IP Addressing
Symptom:
Route debug command prints only first few lines and repeats the same output until the operation is
aborted.
Condition:
Inappropriate output upon execution of the route debug command.
Defect ID:
DEFECT000561233
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
Static Routing (IPv4)
Symptom:
While performing Traceroute to IP-address in non-default VRF, ICMP-Error response is received
from an IP-address in default VRF.
Condition:
Ingress port is tagged to multiple VLANs and few of the VLANs are in non-default VRF.
Defect ID:
DEFECT000562036
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 07.4.00
Technology:
Traditional Stacking
Symptom:
Standby Unit [2] freezes after two weeks running successfully.
Condition:
This issue can be seen with a two unit ICX6610 stack running 7.4.00j code and DHCP snooping
enabled.
Defect ID:
DEFECT000562558
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Other
Reported In Release:
FI 08.0.30
Technology:
Other
Symptom:
When the ICX7450-48F connected to edge switches (Cisco SF-102) then the link does not come up.
Cisco switch sees the link but Brocade does not see the link
Condition:
When the ICX7450-48F connected to edge switches (Cisco SF-102) then the link does not come up.
Cisco switch sees the link but Brocade does not see the link
Defect ID:
DEFECT000562730
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.10
Technology:
BGP4 - IPv4 Border Gateway Protocol
Symptom:
BGP connections in down state with TCP buffer leak.
Condition:
This issue can seen on EBGP and IBGP connections with device being up for more than 90 - 180
days.
FastIron Software Release 08.0.30g Release Notes 52
Defect ID:
DEFECT000562755
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
Trunk deploy fails during boot up.
Condition:
This issue is seen on system boot with LAG configured on 10G/1G dual-speed port where the port is
configured as 1G.
Defect ID:
DEFECT000563550
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 07.3.00
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
Device may unexpectedly reload when polling IPv6IfEntry MIB, which has null value.
Condition:
SNMP polling of IPv6IfEntry MIB on a device configured as switch.
Workaround:
Disable SNMP IPv6 MIB polling.
Defect ID:
DEFECT000564096
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Following POE warning message displayed in the session
"M:poe S:status L:0 - Illegal PoE power request of 0 mW in CDP/LLDP message on port. Request
ignored."
Condition:
This issue is seen on power negotiation with the POE device after reload.
Defect ID:
DEFECT000564256
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
Plugging a 7450 switch port (mdix) into another 7450 switch port (mdix) (same switch) with a
straight through cable their link keeps up
Condition:
Plugging a 7450 switch port (mdix) into another 7450 switch port (mdix) (same switch) with a
straight through cable
Defect ID:
DEFECT000564301
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.20
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
On SNMP-GET request or SNMP-GETNEXT request, device fails to respond for the MIB objects
under the snVrrp.
Condition:
This issue is seen when polling for SnVrrp MIB objects using SNMP.
FastIron Software Release 08.0.30g Release Notes 53
Defect ID:
DEFECT000564379
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.10
Technology:
System
Symptom:
CPU utilization spikes to 99% when speed-duplex 1000-full-master is configured on ports ICX6450
ports 1/2/1 to 1/2/4 with copper SFP connected there
Condition:
When speed-duplex 1000-full-master is configured on ports ICX6450 ports 1/2/1 to 1/2/4 with copper
SFP connected there
Defect ID:
DEFECT000564431
Technical Severity:
Medium
Probability:
Low
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 07.3.00
Technology:
System
Symptom:
On ICX6610 device the couple of 1G copper port connected to device is goes down.
Condition:
In one of the ICX6610 device the couple of 1G copper ports were connected to device suddenly went
into DHCP discover mode.
Defect ID:
DEFECT000564553
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Hardware Monitoring
Symptom:
On ICX7750-48C when the "dm diagnostics" test is run then the Packet Line Rate test in the test suite
fails for port no 1/1/1 to 1/1/48.
Condition:
When the "dm diagnostics" test is run on ICX7750-48C unit then the Packet Line Rate test in the test
suite fails for port no 1/1/1 to 1/1/48
Defect ID:
DEFECT000564583
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.30
Technology:
System
Symptom:
On ICX7250-48P unit during reload the error message "Skipping bad block error" is observed. On
reload the following message appears on console:
NAND read: device 0 offset 0x4000000, size 0x2000000
....................................................Skipping bad block 0x05a0000
0
Skipping bad block 0x05b00000
............ 33554432 bytes read: OK
Condition:
The skipping bad block error message appear during unit reload for ICX7250-48P
Recovery:
There is no functional impact due to these error
Defect ID:
DEFECT000565380
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Monitoring
Reported In Release:
FI 08.0.30
Technology:
Hardware Monitoring
Symptom:
Continuous scrolling of error messages "I2C_ioctl failed: bus 1, dev 0x51, errno 121" when entering
config mode on ICX7450 stack.
Condition:
This issue is seen when non-Brocade SFPs with Serial number eTBFP343-FSL10 is used in FI
devices.
FastIron Software Release 08.0.30g Release Notes 54
Defect ID:
DEFECT000565422
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.01
Technology:
System
Symptom:
The ‘link-config gig’ command does not get applied to non-primary ports of a LAG after reload in the
ICX6430 device.
Condition:
This issue is observed on ICX6430 switch on the non primary LAG ports. When the ‘link-config gig’
command is provided for LAG ports and system is reloaded then after reload this command does not
get applied to non-primary ports of a LAG
Defect ID:
DEFECT000565551
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
MAC Port-based Authentication
Symptom:
Even though a MAC address is already authenticated through MAC-authentication, traffic from the
MAC address is rejected on new VLANs with reason 'Maximum Limit reached'.
Condition:
Mac-authentication is enabled on an interface and the interface has clients sending traffic in multiple
VLANs.
Defect ID:
DEFECT000565808
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
Security Vulnerability
Symptom:
The Fastiron devices will reload when running NMAP scan.
Condition:
When NMAP scan is run continuously, then the Fastiron devices will reload unexpectedly.
Defect ID:
DEFECT000565922
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
SSH - Secure Shell
Symptom:
Customer is not able to establish new SSH/TELNET session after couple of days.
Condition:
The issue is because of port scanning or BNA polling. During port scanning process, the established
child task is not closed and it cause the problem in new child task creation.
Defect ID:
DEFECT000566336
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Configuration Fundamentals
Symptom:
ICX7450 4x10G Copper Port LED goes OFF when the link is UP.
Condition:
When the port-speed is set to 1000-full, ICX7450 4x10G Copper Port LED goes OFF even though the
link is UP.
Defect ID:
DEFECT000567010
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.10
Technology:
OSPF - IPv4 Open Shortest Path First
Symptom:
FI device will be reloaded when OSPF is enabled with ACL deny rule.
Condition:
When OSPF is enabled with ACL rule to hit its own OSPF interface IP addresse, FI device will be
reloaded.
Workaround:
ACL rule can be modified to permit its own OSPF interface IP addresses and deny others.
FastIron Software Release 08.0.30g Release Notes 55
Defect ID:
DEFECT000567117
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 07.4.00
Technology:
IP Addressing
Symptom:
The device may unexpectedly reload with DHCP snooping enabled.
Condition:
This issue may be seen when the device has many pending ARP entries with DHCP snooping enabled
on the device.
Workaround:
Turn off DHCP snooping.
Defect ID:
DEFECT000567173
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Traffic Management
Reported In Release:
FI 08.0.30
Technology:
Rate Limiting and Shaping
Symptom:
In ICX7250, the traffic loss is observed with rate-shaping configuration after the switch reload.
Condition:
The rate-shaping is configured on a ICX7250 switch and 6-queue traffic is running clean. After
switch is reloaded and traffic is restarted, observed 50% traffic loss for queue-0 traffic which is close
to 10% of interface bandwidth.
Defect ID:
DEFECT000568464
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
ACLs - Access Control Lists
Symptom:
Configuration of MAC filter on dual-mode port interface fails.
Condition:
MAC filter configuration on a dual-mode port.
Defect ID:
DEFECT000568642
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.10
Technology:
MRP - Metro Ring Protocol
Symptom:
High CPU utilization seen when adding VLANs to MRP topology group causing OSPF flaps.
Condition:
This issue is seen when adding member VLAN to topology group
Defect ID:
DEFECT000569609
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
SSH - Secure Shell
Symptom:
Sometime the user is unable to establish a SSH session with the device.
Condition:
This issue can be seen on login/logout of SSH with one or more NMAP port scanning on the device.
Recovery:
Reboot the device
Defect ID:
DEFECT000569613
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
MAC Port-based Authentication
Symptom:
LLDP med policy shows default information after RADIUS server assigns LLDP med dynamically
Condition:
This issue is seen when radius server assigns LLDP med dynamically to the connected phone.
FastIron Software Release 08.0.30g Release Notes 56
Defect ID:
DEFECT000569749
Technical Severity:
Medium
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
SDN
Reported In Release:
FI 08.0.30
Technology:
OpenFlow
Symptom:
FI Device reboots spontaneously while removing a rule from flow table using openflow controller.
Condition:
Openflow controller sends command to FI device for removing a rule from flow table.
Defect ID:
DEFECT000570318
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.20
Technology:
802.1x Port-based Authentication
Symptom:
Statically authenticated dot1x-client is authorized on VLAN 4092.
Condition:
First DOT1X client is authenticated on a VLAN assigned by RADIUS. Second DOT1X client is
statically authenticated on VOICE-VLAN.
Defect ID:
DEFECT000570454
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.10
Technology:
System
Symptom:
Brocade 6430-C12 devices stop offering power to connected Meru AP320/AP320i devices.
Condition:
This issue may occur when Brocade 6430-C12 is connected to Meru AP320/AP320i devices.
Defect ID:
DEFECT000570822
Technical Severity:
High
Probability:
Medium
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VRP - VLAN Registration Protocol
(GVRP, MMRP, MVRP)
Symptom:
Intermittent network connectivity observed after core device is reloaded.
Condition:
This issue can be seen on ICX7450/7250/7750 connected to multiple edge stacks with 2 port LAG
and GVRP configured.
Defect ID:
DEFECT000571029
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
No warning message is displayed when a flexauth configuration is expected to overwrite existing
configuration
Condition:
When "dot1x auth-filter x x" is given when an existing config of "dot1x auth-filter 1" is already
present
Defect ID:
DEFECT000571045
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
Authenticated clients are wrongly placed into global auth-def-vlan
Condition:
This issue is seen when dot1x auth-filter is configured to bypass dot1x authentication and classify the
Clients into local auth-def-vlan.
And there is auth-default-vlan configured at interface level. But when dot1x client is authorized by
dot1x auth-filter, it is wrongly authorized in the global auth-default-vlan.
FastIron Software Release 08.0.30g Release Notes 57
Defect ID:
DEFECT000571767
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
In switch image, mac-auth is not working properly for Dot1xNotCapable Clients.
Condition:
This issue is seen with switch image and mac-authentication is enabled.
Defect ID:
DEFECT000571832
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
Ports default spanning tree state is incorrect.
Condition:
when we un-configure a peer-info on a dynamic lag.
Defect ID:
DEFECT000571848
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
When port receives LACP PDU with information that does not match with the configured peer info,
sometime system does not bring this port into mis-match error state.
Condition:
When the configured peer information's system priority is different from the peer information
contains in the LACP PDU while the system mac and LACP key are both match.
Defect ID:
DEFECT000572014
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Stacking
Reported In Release:
FI 08.0.30
Technology:
Traditional Stacking
Symptom:
Standby unit may unexpectedly reload when configuring peer-info on a dynamic LAG.
Condition:
This issue can be seen when configuring peer-info on a dynamic LAG
Defect ID:
DEFECT000572119
Technical Severity:
Critical
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
802.1x Port-based Authentication
Symptom:
Switch may unexpectedly reload when trying to authenticate the dot1x client behind the phone.
Condition:
Switch tries to authenticate the dot1x client behind the phone.
Defect ID:
DEFECT000572534
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
LAG - Link Aggregation Group
Symptom:
All lag ports are moving to forwarding state even if some of the lag member ports should be blocking.
Condition:
After dynamic lag is deployed, all lag ports are moving to forwarding state even though some of the
ports are at mis-cabling error condition.
Defect ID:
DEFECT000572952
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
SNMP - Simple Network Management
Protocol
Symptom:
SNMP walk on ISO MIB stops in snRIP table.
Condition:
This issue is seen on SNMP walk of ISO MIB or snRIP table.
FastIron Software Release 08.0.30g Release Notes 58
Defect ID:
DEFECT000572992
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
AAA - Authentication, Authorization,
and Accounting
Symptom:
Console will be locked during reload when Accounting is turned on for radsec.
Condition:
Console will get blocked with radsec when Accounting is turned on
Defect ID:
DEFECT000573164
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Management
Reported In Release:
FI 08.0.30
Technology:
Licensing
Symptom:
Licence validity is displayed as "compliant" even after the expiry of the trial the license.
Condition:
Even when trial license is expired, the validity of the NNLL license is shown as "complaint"
Defect ID:
DEFECT000573249
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 3 Routing/Network Layer
Reported In Release:
FI 08.0.30
Technology:
DHCP - Dynamic Host Configuration
Protocol
Symptom:
DHCP OFFER being sent to incorrect MAC address
Condition:
When the unicast bootp flag is set, the relay agent forwards the offer packet based on the entry in the
ARP table.
This issue is seen when host B sends a DISCOVER packet after host A has acquired an IP address
and releases the IP address.
Workaround:
Clear ARP on the relay agent.
Defect ID:
DEFECT000573308
Technical Severity:
Medium
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.30
Technology:
802.1x Port-based Authentication
Symptom:
Dot1x authenticated port loses connectivity when configuration changes made on another dot1x port
Condition:
When dot1x is enabled on two ports then VLAN membership for these ports in hardware should be
untagged. But if dot1x is disabled on any one of the port then the VLAN membership of the other port
changed to tagged from untagged. This causes the switch to send tagged frame when ping comes from
outside the switch to the PC and hence connectivity loss issue is reported.
Defect ID:
DEFECT000574066
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VRP - VLAN Registration Protocol
(GVRP, MMRP, MVRP)
Symptom:
Unable to deploy LAG on un-deploy and deploy, with GVRP enabled and VLAN entries are
dynamically learnt.
Condition:
This issue is seen when GVRP is enabled in LAG interface and LAG is un-deployed and deployed
with VLAN entries dynamically learnt.
FastIron Software Release 08.0.30g Release Notes 59
Defect ID:
DEFECT000574131
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Layer 2 Switching
Reported In Release:
FI 08.0.30
Technology:
VRP - VLAN Registration Protocol
(GVRP, MMRP, MVRP)
Symptom:
When receiving LeaveAll message on STP blocked port, it does not transmit Empty message to peer
applicant for sending re-declaration of the registered attributes. So STP blocked port is getting
removed/added to GVRP VLAN continuously and error messages printed in console.
Condition:
The VLAN addition/deletion error message will be seen in console when the VLAN is learnt through
only STP blocked port as tagged member port. When the GVRP VLAN has other ports also member
ports, STP blocked port add or removal only happen and no logs will be printed.
Defect ID:
DEFECT000574769
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
Security
Reported In Release:
FI 08.0.40
Technology:
MAC Port-based Authentication
Symptom:
"voice-vlan <VLAN-ID>" command is configured on the switch. After "write memory" and reload,
the "voice-vlan" command is not available in the running configuration.
Condition:
Reload after saving "voice-vlan <VLAN-ID>" command to startup configuration.
Defect ID:
DEFECT000575664
Technical Severity:
High
Probability:
High
Product:
Brocade FastIron OS
Technology Group:
System
Reported In Release:
FI 08.0.40
Technology:
System
Symptom:
The mdi-mdix setting does not work correctly on ICX7450 when the "mdi-mdix mdi" command is
followed by "speed-duplex 1000-full-master" command
Condition:
When the "mdi-mdix mdi" command is issued followed by "speed-duplex 1000-full-master"
command
Closed defects with code changes in Release 08.0.30c
This section lists defects closed with code changes in in the 08.0.30c release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID: DEFECT000552672
Technical Severity: Medium
Probability: Medium
Product: IronWare
Technology: System
Reported In Release: FI 08.0.30
Technology Area: CLI
Symptom: The speed-duplex 100-full config is not getting saved after reload.
Condition: The speed-duplex config for 100M full is not getting saved after reload.
Workaround: Reconfigure the speed 100-full command again for those ports after reload.
FastIron Software Release 08.0.30g Release Notes 60
Defect ID: DEFECT000563942
Technical Severity: Medium
Probability: High
Product: IronWare
Technology: Stacking
Reported In Release: FI 08.0.30
Technology Area: Traditional Stacking
Symptom: On a 4-unit ICX7750 stack, the operational lags cannot be created from unit-3 or unit-4.
Condition: On a 4-unit ICX7750 stack, if unit-3 and unit-4 are added at later time then the user will not be able to
create an operational lags from unit-3 or unit-4.
Recovery: Reloading the stack.
Defect ID: DEFECT000564145
Technical Severity: High
Probability: High
Product: IronWare
Technology: Stacking
Reported In Release: FI 08.0.30
Technology Area: Traditional Stacking
Symptom: Stack unit 3 to 8 may unexpectedly reload
Condition: This issue is seen in stack having more than 2 units with SFLOW enabled
Workaround: Disable SFLOW
Defect ID: DEFECT000564427
Technical Severity: High
Probability: Medium
Product: IronWare
Technology: Layer 2
Reported In Release: FI 08.0.30
Technology Area: VLAN
Symptom: The standby unit in ICX7250 will be reloaded unexpectedly.
Condition: When changing the default VLAN to management VLAN, standby unit in ICX7250 will be reloaded
unexpectedly.
Defect ID: DEFECT000564500
Technical Severity: High
Probability: Low
Product: IronWare
Technology: Stacking
Reported In Release: FI 08.0.30
Technology Area: Traditional Stacking
Symptom: In ICX7450 stack, the stack port will start flapping.
Condition: In ICX7450 stack, when the unit joins the stack after a crash, the stack port flapping will be seen even
without any traffic.
Defect ID: DEFECT000565380
Technical Severity: High
Probability: High
Product: IronWare
Technology: System
Reported In Release: FI 08.0.30
Technology Area: CLI
Symptom: Continuous scrolling of error messages "I2C_ioctl failed: bus 1, dev 0x51, errno 121" when entering
config mode on ICX7450 stack.
Condition: This issue is seen when non-Brocade SFPs with Serial number eTBFP343-FSL10 is used in FI devices.
Defect ID: DEFECT000565808
Technical Severity: High
Probability: Medium
Product: IronWare
Technology: Security
Reported In Release: FI 08.0.30
Technology Area: Security Vulnerability
Symptom: The Fastiron devices will reload when running NMAP scan.
Condition: When NMAP scan is run continuously, then the Fastiron devices will reload unexpectedly.
FastIron Software Release 08.0.30g Release Notes 61
Defect ID: DEFECT000566336
Technical Severity: Medium
Probability: High
Product: IronWare
Technology: System
Reported In Release: FI 08.0.30
Technology Area: Component
Symptom: ICX7450 4x10G Copper Port LED goes OFF when the link is UP.
Condition: When the port-speed is set to 1000-full, ICX7450 4x10G Copper Port LED goes OFF even though the
link is UP.
Closed defects with code changes in Release 08.0.30b
This section lists defects closed with code changes in in the 08.0.30b release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000507710
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.01
Technology Area:
NTP - Network Time Protocol
Symptom:
The syslog "The system clock is not synchronized to any time source" will be printed.
Condition:
When a FastIron device is running continuously for more than 24-hrs, the syslog will be printed.
Defect ID:
DEFECT000528034
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.4.00
Technology Area:
MAC ACLs
Symptom:
Layer 2 unicast traffic is flooding on certain ports
Condition:
The issue will be observed when there is a 10G loop in the network without any spanning tree
configured.
Workaround:
Configure spanning tree before enabling the 10G ports
Recovery:
Reload the setup.
Defect ID:
DEFECT000532589
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
Customer running the port scan utility nmap tool to scan the ICX switch saw that after few days,
SSHv2 stopped spawning new sessions.
Condition:
Run the nmap tool to scan the ICX switch for long hours. After few days, attempt to SSH to the ICX
switch
Defect ID:
DEFECT000537321
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.10
Technology Area:
VLAN
Symptom:
Hosts that are directly connected to a FastIron stacking device through VLAN bridging interface are
not reachable.
Condition:
In a FastIron stacking device, the hosts that are directly connected through the VLAN bridging
interfaces are not reachable.
FastIron Software Release 08.0.30g Release Notes 62
Defect ID:
DEFECT000537621
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Clients moved to restricted vlan.
Condition:
Radius server not reachable due to network issues.
Workaround:
Clear the session using the CLI command 'clear dot1x session'
Defect ID:
DEFECT000537902
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 07.3.00
Technology Area:
Traditional Stacking
Symptom:
ICX6610 stack unit is segmented or deleted itself from the stack.
Condition:
During operation, ICX6610 stack unit got segmented or deleted itself from the stack.
Recovery:
The affected unit can be reloaded which will re-establish its communication with rest of the stacking
units.
Defect ID:
DEFECT000538959
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 07.4.00
Technology Area:
Component
Symptom:
Rapid increment of CRC errors seen in 10GB cards in SX devices.
Condition:
CRC errors are seen only on 10GB uplinks between core switches (MCT links) or edge switch
uplinks to core switches
Workaround:
Reboot the switch connected to the port on which CRC errors are seen.
Defect ID:
DEFECT000543822
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
In ICX6610 device having dual power supply units, fatal PSU mismatch error may be thrown.
Condition:
When dual DC Power supply units are connected to ICX6610 device, the fatal PSU mismatch error
may be reported.
Defect ID:
DEFECT000544295
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
GRE
Symptom:
In ICX6610 device, "show statistics tunnel’ output displays always zero in the hardware counters'
parameters.
Condition:
The output of "show statistics tunnel" command in ICX6610 displays empty hardware counter
parameters.
Defect ID:
DEFECT000545958
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.20
Technology Area:
IPv4 Multicast Switching
Symptom:
FastIron device may reset unexpectedly when it receives more than 5000 IGMPv2 joins for the
registered mutlicast groups.
Condition:
When the FastIron device receives more than 5000 IGMPv2 joins for a multiple multicast group, the
device may reset unexpectedly.
FastIron Software Release 08.0.30g Release Notes 63
Defect ID:
DEFECT000545997
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
Customer running the port scan utility nmap tool to scan the ICX switch saw that after few days,
SSHv2 stopped spawning new sessions.
Condition:
Run the nmap tool to scan the ICX switch for long hours. After few days, attempt to SSH to the ICX
switch.
Defect ID:
DEFECT000547384
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.10
Technology Area:
Other IPv4
Symptom:
Executing "clear arp" in a stack can cause some stack members to continuously drop packets
addressed to some destinations. Customer can see this issue in a production environment when trying
to perform Layer3 routing via LAGs that span multiple stack members. Packets from different source
IP addresses are passed across different LAG links by neighboring switches, entering through
different stack members. Routing to the same destination from some source hosts succeeds while
routing from other source hosts fails depending on which stack member handles the traffic.
Condition:
This can be observed after executing "clear arp". Executing "show stack connection" and then after
the complete display of the output executing "clear arp" appears to expose this issue more easily than
"clear arp" alone. Executing "clear arp" repeatedly with a short interval exposes this issue more often.
Recovery:
After this issue happens, the most reliable method of clearing it up is executing "clear ip route".
Defect ID:
DEFECT000547593
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
In FastIron device, when "no snmp-server enable traps link-change" command is configured on a
primary port of the LAG interface, the command gets applied only to the primary port and fails to get
applied to the member ports and hence traps are sent for member ports.
Condition:
When "no snmp-server enable traps link-change" command is enabled on primary port of a LAG, the
command does not take effect in the member ports of the LAG.
Defect ID:
DEFECT000547840
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
TFTP
Symptom:
DHCP client does not correctly set TFTP server name, hostname, or bootfile as stated in the
configuration guide, this results in auto-config and auto-update not to work.
Condition:
The issue is seen in DHCP auto-configuration and auto-update
Defect ID:
DEFECT000548213
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv6 Multicast Routing
Symptom:
On enabling PIMv6 over virtual Ethernet interface, the associated IPv6 neighbor discovery fails.
Condition:
The issue is observed during IPv6 neighbor discovery with PIMv6 enabled on Virtual Ethernet
interface.
FastIron Software Release 08.0.30g Release Notes 64
Defect ID:
DEFECT000548252
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
DoS - Denial of Service
Symptom:
Stale TCAM entry left behind after a port is deleted from the VLAN. See on ICX 7750, 7450 and
7250.
Condition:
Observed when DoS attack prevention is configured on VE and a port is removed from the VLAN
when a DoS attack is detected
Issue is Fixed
Defect ID:
DEFECT000548377
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.10
Technology Area:
Security Vulnerability
Symptom:
Idle time out is not working as expected for SSHv2 sessions.
Condition:
Configure idle timeout for SSHv2 session. SSH to the ICX switch. Wait till the idle time elapses.
Workaround:
Disable and enable idle time out configuration.
Defect ID:
DEFECT000549344
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
DoS - Denial of Service
Symptom:
DoS attack stops working.
Condition:
Issue is seen after a fail-over and ICMP/TCP Syn packets are coming on ports of Standby unit. It is
seen on ICX 7250, 7450 and 7750 platforms.
Defect ID:
DEFECT000549566
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
With Dos attack enabled on a flexauth interface, after a stack switchover that interface goes down
Condition:
Re-authentication is attempted after switchover but authentication does not succeed due to the dos
protection limit being reached.
Workaround:
Configure the dos-protection mac-limit to twice the auth max-sessions allowed on the port.
If issue still persists, then manually enable the interface when the port goes down. This will trigger
authentication.
Defect ID:
DEFECT000549656
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.10
Technology Area:
IPv4 Multicast Switching
Symptom:
When we have less than 100 multicast flows in VLAN, entries may age out faster than expected after
the traffic is stopped.
Condition:
Traffic is paused for a period less than the aging time, traffic loss is still seen when "ip multicast
disable-flooding" is enabled.
Workaround:
Disable "ip multicast disable-flooding"
FastIron Software Release 08.0.30g Release Notes 65
Defect ID:
DEFECT000549721
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
BGP4 (IPv4)
Symptom:
When more than 10 BGP Communities set from route-map then additional community value
“65535:65280” gets added automatically along with “no advertise” and “no export” communities.
Even the community values are changed under the configuration
Condition:
The issue is observed when more than 10 BGP communities were set from route-map
Defect ID:
DEFECT000549957
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
Stack enable command on ICX 7450 with 10G stacking takes few seconds to complete
Condition:
Stacking with 10G and using trunks and on doing a stack enable
Recovery:
The command completes in a few seconds. No recovery required.
Defect ID:
DEFECT000549976
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
CCEP LAG on the MCT cluster stays in blocked state.
Condition:
After configuring "enable egress-acl-on-cpu-traffic" on ICX7750 MCT
Defect ID:
DEFECT000550289
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
MAC authentication fails and phones and printers go to offline.
Condition:
When two Radius-servers are configured and AAA 802.1x Accounting feature is enabled in global
configuration, the Access-Request packet with wrong station-id causes MAC authentication to fail.
Defect ID:
DEFECT000551058
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
1. Used ICX7250 4 unit stack
2. Active unit is crashing when run "stack secure-setup" and changing unit IDs
Condition:
Switch may crash due to timing issue in LLDP.
Workaround:
Avoid changing the stack ID when using the secure setup.
Recovery:
Reload will recover.
Defect ID:
DEFECT000551203
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
"show dot1x session all" command shows the session as authorized on 4092 VLAN.
Condition:
802.1x clients are authenticated without dynamic vlan attribute.
FastIron Software Release 08.0.30g Release Notes 66
Defect ID:
DEFECT000551754
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.10
Technology Area:
OSPFv3 (IPv6)
Symptom:
Router will reboot when an incorrect LS ID of self originated Network LSA received from
neighboring router
Condition:
OSPFv3 neighbor sends an Network LSA originated by local router with incorrect LS_ID such that
LS_ID is more than the max interface number supported on local router
Workaround:
No Workaround
Defect ID:
DEFECT000552094
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
The ICX7750 may get automatically reloaded after system boot up with the following error messages,
FATAL MISMATCH: FRU fans do not have same air-flow direction!!!
System will shutdown in 301 seconds!!!
Condition:
The FAN direction is detected incorrectly which triggered the fatal mismatch condition, hence system
was reloaded automatically.
Defect ID:
DEFECT000552096
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
An User is authenticated using 802.1X. User has re-authentication enabled. During re-authentication
if wrong credential is provided User is not blocked even though re-authentication fails
Condition:
When wrong credentials are provided during reauthentication
Defect ID:
DEFECT000552408
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
The output of "show interfaces management 1" could display a different bia every time the command
is issued.
Condition:
The output of "show interfaces management 1" could display a different bia every time the command
is issued.
Workaround:
No functional impact, hence no workaround required.
Defect ID:
DEFECT000552554
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
Port Loop Detection
Symptom:
The "sh loop-detection no-shutdown" command always displays the ports are in loop after clearing
loop in the setup.
Condition:
This issue is seen when loop is detected and on execution of "sh loop-detection no-shutdown"
command after recovery of loop.
FastIron Software Release 08.0.30g Release Notes 67
Defect ID:
DEFECT000552811
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.10
Technology Area:
Mixed Stacking
Symptom:
"port init success" messages appear repeatedly on ICX6610.
Condition:
When calibration of stacking ports is enabled by default, "port init success" messages are generated
when recalibration occurs.
Defect ID:
DEFECT000553444
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.20
Technology Area:
Traditional Stacking
Symptom:
In ICX7450 or 7750 stack, outgoing IP packets from standby/member unit are updated with the
source MAC of the unit's mac-address instead of stack MAC
Condition:
This issue is seen with 7450 or 7750 stack units after a reload, with stack mac not synchronized to
standby and member unit.
Workaround:
Disable standby stack unit
Defect ID:
DEFECT000553554
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Web Management
Symptom:
ICX7750 running 8020c resets when clock is changed in web GUI using HTTPS
Condition:
when clock is configured through web GUI using HTTPS on ICX7750 running 8020c causes reset.
Workaround:
HTTP would work fine.
Defect ID:
DEFECT000553556
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The CPU goes high when clients are authorized with same VLAN and different ACL for mac-
authentication and 802.1x authentication methods.
Condition:
When the ports are enabled with mac-authentication and 802.1x authentication methods, the clients
on these ports are authorized with same VLAN but different ACL.
Defect ID:
DEFECT000553639
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
Valid Range for timeout is not displayed in help string in the flash-timeout command
Condition:
flash-timeout command usage
Defect ID:
DEFECT000553747
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
Web Management
Symptom:
web-man vlan command is allowed in FIPS operative state
Condition:
Web-man enable vlan configuration is allowed in FIPS mode
FastIron Software Release 08.0.30g Release Notes 68
Defect ID:
DEFECT000553767
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 07.4.00
Technology Area:
Web Management
Symptom:
In ICX6450, dual-mode and router-ve configurations cannot be removed using Web GUI.
Condition:
When removing dual-mode and router-ve configurations in ICX6450 using Web GUI, the
configurations are not removed.
Defect ID:
DEFECT000553801
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
CLI
Symptom:
FI device may unexpectedly reload while 802.1x client are re-authenticated.
Condition:
802.1x authentication method and re-authentication is configured in FI device.
Defect ID:
DEFECT000554162
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.10
Technology Area:
Traditional Stacking
Symptom:
Syslog is generated for 40G passive copper optics as "Optic is not Brocade qualified".
Condition:
This issue is observed when 40GE passive copper optics is used for stacking.
Defect ID:
DEFECT000554196
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
No syslog or SNMP trap notification, when the stack device is changed to Standalone mode.
Condition:
This scenario is seen when the stack device is changed to Standalone mode.
Defect ID:
DEFECT000554233
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Monitoring/RAS
Reported In Release:
FI 08.0.20
Technology Area:
Syslog
Symptom:
In ICX7450, SYSLOG/TRAP is not generated during power supply failures.
Condition:
In ICX7450, when there is a power supply failure no SYSLOG/TRAP message is generated.
Defect ID:
DEFECT000554399
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
ICX7450 1G port with auto speed will not come up when connected to a peer of fixed speed setting
Condition:
Connect 1G copper of port of ICX7450 with speed as auto to a peer with 10M/100M fixed
configuration.
Defect ID:
DEFECT000554471
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 07.4.00
Technology Area:
Component
Symptom:
Error message "cpssDxChHwPpStartInit() failed (4)" is seen when ICX6610 is reloaded.
Condition:
Reload of ICX6610 with B3 chip support
FastIron Software Release 08.0.30g Release Notes 69
Defect ID:
DEFECT000554901
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
Multi-Chassis Trunking
Symptom:
MAC movement in MCT clients, with IPv6 packets being looped. MCT Egress ACL rules not
programmed to block, IPv6 packets on ICL port to CCEP port.
Condition:
MCT environment with IPv6 traffic.
Defect ID:
DEFECT000555200
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.40
Technology Area:
SSH - Secure Shell
Symptom:
when nmap port scanning is running, telnet server stops responding
Condition:
when nmap port scanning is running, telnet server stops responding
Defect ID:
DEFECT000555382
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
DHCP (IPv4)
Symptom:
The high CPU will be observed which causes the CLI to be unresponsive for couple of minutes.
Condition:
When a DHCP client is requesting for an IP address which is unavailable in the address pool of the
DHCP server running with switch image, then the CPU will hang for couple of minutes.
Defect ID:
DEFECT000555431
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
The port transitions and incrementing InErrors are seen on 10G ports of ICX6450-24.
Condition:
When Jumbo frames is enabled in ICX6450-24, the port transitions and incrementing InErrors are
seen on 10G ports of ICX6450-24.
Defect ID:
DEFECT000555486
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Link Aggregation
Symptom:
DO NOT DISCLOSE New feature in 8.3b
Condition:
DO NOT DISCLOSE New feature in 8.3b
Defect ID:
DEFECT000555571
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Traffic forwarding stops between a MAC Authenticated and a 802.1x authenticated port after
upgrading to 8030b
Condition:
One port having multiple (30) mac-authenticated Users and another port having 30 802.1X Users.
Traffic is being forwarded between these two ports in 8020a, but stops on upgrade to 8030b.
Defect ID:
DEFECT000555603
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The multi-untagged mode disabled on an interface is removed from configuration after reload.
FastIron Software Release 08.0.30g Release Notes 70
Condition:
The multi-untagged mode is enabled in global configuration and it is disabled in interface level.
Defect ID:
DEFECT000555611
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
An error message "drv_cpss_dx_pp_clear_na_storm_if_found_core XXXX.XXXX.XXXX vlan
<VLAN_ID> Invalid hash" is displayed on the console.
Condition:
Port configured with 802.1x authentication method is disabled with active 802.1x clients.
Defect ID:
DEFECT000555689
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.10
Technology Area:
RIP (IPv4)
Symptom:
System may unexpectedly reload when executing 'dm pp-dev 0 tcam show-route' debug CLI
command.
Condition:
Execution of 'dm pp-dev 0 tcam show-route' debug CLI command.
Defect ID:
DEFECT000555771
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
"Show mac-authentication session all" command displays more than one VLAN whereas "show dot1x
session all" command displays only one VLAN.
Condition:
Interfaces have clients that are authorized in multiple Tagged VLANs using mac-authentication and
802.1x authentication methods.
Defect ID:
DEFECT000555774
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Help string for reauth-period command does not indicate that it is not applicable for mac-
authentication
Condition:
When using reauth-period option for MAC Authentication
Defect ID:
DEFECT000555779
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Reauthentication and reauth-period are displayed while executing "show mac-auth config" command.
Condition:
show mac-auth config command should not display these values as mac-authentication does not
support CLI-based re-authentication
Defect ID:
DEFECT000555872
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
"show dot1x sessions brief" command displays error when executed
Condition:
Execution of "show dot1x sessions brief" CLI command.
FastIron Software Release 08.0.30g Release Notes 71
Defect ID:
DEFECT000556048
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
sh mem command output shows DRAM memory as 0 bytes
Condition:
Issue a show mem command on CLI
Defect ID:
DEFECT000556055
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
MRP - Metro Ring Protocol
Symptom:
Packet loss is observed in a 3 unit metro ring topology.
Condition:
When there is a change in the 3 unit MRP topology, packet loss is experienced
Workaround:
Clear the MAC table in the master node.
Defect ID:
DEFECT000556085
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
After Radius timeout during 802.1X authentication, user is placed in vlan id 4092 instead of restricted
VLAN
Condition:
The Authentication time out action ("auth timeout action") is configured as authentication fail. This is
to put the user to restricted vlan upon Radius timeout during authentication.
Defect ID:
DEFECT000556118
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
IEEE 802.1w RSTP
Symptom:
High CPU observed and protocols flaps in other vlans in the system.
Condition:
Protocols flaps on other vlans when a more than 4000 arp entries are present on a port and network
events (like Protocol enabling that causes mac/arp flush on the port) occurs.
Defect ID:
DEFECT000556122
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.10
Technology Area:
IPv4 Multicast Switching
Symptom:
The multicast IPv4/IPv6 traffic destined to MDNS is trapped to CPU, instead of getting VLAN
flooded in the hardware.
Condition:
IPv4/IPv6 multicast traffic to MDNS addresses are not flooded in the VLAN when VE has IPMv4/v6
routing enabled.
Defect ID:
DEFECT000556177
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
If Radius returns different vlan during re-authentication, User is moved to restricted VLAN or
sometimes even blocked
Condition:
User is authenticated with 802.1X with dynamic untagged VLAN from Radius and re-authentication
is enabled.
FastIron Software Release 08.0.30g Release Notes 72
Defect ID:
DEFECT000556232
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The following CLI command is not saved during reload.
Mixed-STK(config-if-e1000-2/1/11)#auth timeout-action failure
Condition:
The above CLI command is configured and the device is reloaded. Upon reload, Radius server is not
reachable and authentication is attempted. However, User will not be blocked if even authentication
attempt times out.
Defect ID:
DEFECT000556328
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Memory leak observed on a Brocade ICX/FCX device
Condition:
Seen when Flexauth sessions are cleared
Defect ID:
DEFECT000556345
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Increase in memory usage, when clients authenticate and age out using mac-authentication
Condition:
MAC authentication enabled on an interface with clients authenticated and age-out frequently.
Defect ID:
DEFECT000556390
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
FI device authenticates more than configured number of allowed MAC addresses.
Condition:
MAC authentication is enabled on interface and maximum authentication session is configured.
Defect ID:
DEFECT000556444
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Multi-Chassis Trunking
Symptom:
In MCT deployment,total number of static mac address may not match between the mct cluster
devices.This defect is applicable for all MCT supported platforms
Condition:
The total number of static mac address configured does not match between the mct cluster nodes. One
of the mct cluster device shows a higher number than the mct peer.
Workaround:
No workaround available.This doesn’t have any functional impact & just a count mismatch
between the two mct peers.
Recovery:
No workaround available. This doesn’t have any functional impact & just a count mismatch between
the two mct peers.
Defect ID:
DEFECT000556643
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The mac-authentication auth-filter configuration does not authenticate clients in tagged VLAN.
Condition:
When a MAC auth client is configured to be authenticated on a tagged VLAN, auth-filter does not
work.
FastIron Software Release 08.0.30g Release Notes 73
Defect ID:
DEFECT000556666
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.10
Technology Area:
IPv6 Multicast Routing
Symptom:
IPV6 DHCP may not work when IPv6 PIM routing is enabled on the VLAN/VE.
Condition:
When IPV6 PIM routing is enabled on VLAN/VE., IPv6 DHCP mutlicast traffic (sent to multicast
address FF02::1:2) is not getting flooded in VLAN.
Defect ID:
DEFECT000556738
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
ACLs (IPv4)
Symptom:
The preserve vlan option is not applicable for set ip next-hop in FastIron products
Condition:
The set ip next-hop command that contains the "preserve-vlan" option is not supported for fastiron
products.
Defect ID:
DEFECT000556779
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Re-authetication does not happen after switchover with 256 or more authenticated 802.1x User
Condition:
Initially 256 8021.x users are authenticated. Then stack switch-over is triggered. After Switchover,
the previously authenticated users are not re-authenticated.
Defect ID:
DEFECT000556931
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
VE deletion with flex authentication is fails.
Condition:
Deletion of VE with a flex authentication configuration does not delete VE and shows up in running
configuration. Further deletion of VE not possible.
Defect ID:
DEFECT000556942
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The keyword enable gets displayed on autocompletion of use-radius-server command in the interface
mode which is invalid.
Condition:
An invalid keyword "enable" may be encountered while executing the use radius-server command.
Defect ID:
DEFECT000556960
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The clients configured with "authen timeout-action success" are not authenticated
Condition:
When clients are doing reauthentication and radius-server is not available/reachable.
FastIron Software Release 08.0.30g Release Notes 74
Defect ID:
DEFECT000556980
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
LED on ICX7450-4x10GC module is Green at 1000-full speed
Condition:
After changing port speed to 1000-full, the LED color will be still green.
Workaround:
No workaround available
Recovery:
Software upgrade required
Defect ID:
DEFECT000556985
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
After manual stack switchover, some users are not authenticated
Condition:
On Switchover after 1500 Users are mac-authenticated.
Defect ID:
DEFECT000556991
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
When the client MAC authentication session in tagged VLAN is cleared, the client is not
authenticated again.
Condition:
A client is authenticated in a Tagged VLAN through MAC authentication. The session is cleared with
CLI command 'clear mac-authentication session'.
Defect ID:
DEFECT000556995
Technical Severity:
Low
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
IPv4/IPv6 Host Management
Symptom:
web interface shows a different temperature than CLI
Condition:
web interface shows a different temperature than CLI
Defect ID:
DEFECT000557016
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Data forwarding stops when Max Auth session is changed
Condition:
Flexauth is enabled and 1500 sessions are authenticated. When the maximum auth session is changed
multiple times, traffic from authenticated users are not forwarded,
Defect ID:
DEFECT000557105
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
Traffic drops on lag member.
Condition:
Traffic drops on user defined VRF upon new standby election with LAG ports present across all units
of a stack.
FastIron Software Release 08.0.30g Release Notes 75
Defect ID:
DEFECT000557116
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
The traffic in untagged VLAN is not forwarded by FI device, if the client is authorized with attribute
U:VLAN1;T:VLAN2 when authenticated by MAC authentication.
Condition:
MAC authentication is enabled on the interface. Client triggers authentication by sending tagged
frames. Radius assigns U:<VLAN1>;<T;VLAN2> for the client.
Defect ID:
DEFECT000557117
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
"mac-authentication enable-dynamic-vlan" command is not available in running-confgiuration after
FI device is upgraded to FI 08.030b release.
Condition:
FI device is upgraded from FI 08.0.20 or FI 08.0.30a release to FI 08.0.30b release.
Defect ID:
DEFECT000557120
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
The traffic from 802.1x authenticated client is not forwarded on the port's dynamic Untagged VLAN.
Condition:
802.1x client authenticated with attributes U:VLAN1;T:VLAN2;T:VLAN3. 802.1x client session
expires for VLAN1 and the client tries to send traffic on VLAN1.
Defect ID:
DEFECT000557121
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
After failover on ICX 6xxx and FCX platforms, users are not authenitcated.
Condition:
Flexauth is enabled and there are 32 users that are mac-authenticated. A failover happens (forced).
Once the stack recovers, none of these 32 Users are authenticated again.
Defect ID:
DEFECT000557237
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
PoE/PoE+
Symptom:
ICX 7250 has lower power budget than HW capability
Condition:
ICX 7250 with full utilization of PoE power
Defect ID:
DEFECT000557267
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
If a 802.1x capable client is authorized with attribute T:<vlan-id>, the client gets authorized on
VLAN 4092 and Tagged VLAN <vlan-id>
Condition:
802.1x is enabled on a port and Radius authenticates 802.1x client with attribute T:<vlan-id>.
FastIron Software Release 08.0.30g Release Notes 76
Defect ID:
DEFECT000557310
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
The traffic from clients authenticated on a tagged-VLAN port are forwarded without subjecting it to
mac-authentication.
Condition:
After switchover of ICX stack device the the tagged clients are not authenticated when with device
has one tagged and untagged MAC authentication clients,
Defect ID:
DEFECT000557358
Technical Severity:
Critical
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
Web Management
Symptom:
When web login is attempted using Mozilla browser the device may reset
Condition:
when web login happens via Mozilla browser the device may reset
Workaround:
Web connection from IE or chrome
Defect ID:
DEFECT000557448
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
Web Management
Symptom:
ICX6610 running 8030a reset when it is discovered by BNA.
Condition:
when BNA discovers ICX6610 which is running 8030a causes a reset.
Workaround:
Downgrade to previous version.
Defect ID:
DEFECT000557526
Technical Severity:
Critical
Probability:
Medium
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
'disable multicast-to-cpu' is not supported in ICX7xxx series of products, so must be removed from
configuration.
Condition:
'disable multicast-to-cpu' is configured in ICX7xxx series of products, where the command is not
supported.
Defect ID:
DEFECT000557561
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
Disabling DHCP client on one interface removes the IP address assigned to another interface
Condition:
Disabling DHCP client on one interface removes the IP address assigned to another interface
Defect ID:
DEFECT000557639
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Multi-VRF (IPv4)
Symptom:
Debug command will take long duration to execute and Watchdog timer will kick system restart.
Condition:
During execution of debug command to print IPv4 routes.
FastIron Software Release 08.0.30g Release Notes 77
Defect ID:
DEFECT000557661
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
After switch-over, the new standby unit freezes
Condition:
There are 1500 802.1x User which are authenticated successfully and then a switchover is done
Defect ID:
DEFECT000557684
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Subnet/protocol VLANs
Symptom:
Error messages printed on console:
hal_sw_pp_set_mac_learning(port=1/1/1,enable=1)(T=303) Error - this port is a locked port
stack: 103c7eec 1083da24 105cbb88 10857ec4 1007f054 10856e58 1007ba64 10520414 10518a90
1051ac08 105f9604 105225b4 103c12d4 108d65b4 103c9198 10b7f618 10256778 108d686c
10a1e210 11d57bf8 11d9dd10
hal_sw_pp_set_mac_learning(port=1/1/2,enable=1)(T=303) Error - this port is a locked port
Condition:
If any of these unsupported features were configured by mistake:
ip-proto
ipv6-proto
ip-subnet
ipx-proto
ipx-network
atalk-proto
appletalk-cable-vlan
decnet-proto
netbios-proto
other-proto
Workaround:
Remove the unsupported features via CLI
Recovery:
Remove the unsupported features via CLI and reboot the box.
Defect ID:
DEFECT000557700
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
Stack MAC not sync in standby unit
Condition:
The stack MAC sync issue is seen during hitless-failover in a stack.
Defect ID:
DEFECT000557731
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
Multiple bindings are created on DHCP server database when LAG ports are connected
Condition:
Multiple bindings are created on DHCP server database when LAG ports are connected
Defect ID:
DEFECT000557736
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
Static arp configuration lost when the primary port of the lag is changed and the box reloaded.
Condition:
Primary port of a lag with static arp changed and the box reloaded.
FastIron Software Release 08.0.30g Release Notes 78
Defect ID:
DEFECT000557811
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Port Loop Detection
Symptom:
A loop detection shutdown disable syslog does not appear when a loop is detected in the network and
shutdown disable of loop detection is configured
Condition:
Loop detection shutdown feature enabled and loop caused in a network.
Defect ID:
DEFECT000557852
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
VE creation with flex authentication is fails.
Condition:
Creation and VE after deletion with a flex authentication configuration is not possible.
Defect ID:
DEFECT000557871
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Tagged Client MAC Addresses are removed from MAC Table
Condition:
When an untagged client authenticates on a port after an authenticated tagged client, MAC addresses
of both the clients on that port are removed from MAC-address table. So aging starts for those clients.
Defect ID:
DEFECT000557903
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Misleading syslog message is printed indicating a user authentication failure has occured.
Condition:
The 'auth-timeout' action is configured as failure and failure action is restricted VLAN. When Radius
timeout happens during 802.1X authentication, user is moved to restricted VLAN as expected but
syslog message is misleading.
Defect ID:
DEFECT000557912
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Flexauth Debug logs does not show up in console even after executing the relavant commands
Condition:
Console logs for flexauth transactions does not shows up on console even after executing the
following commands
Mixed-STK#debug dot1x
events Authentication Events
filters Authentication filters
hitless Authentication hitless failover sync messages
misc Authentication Misc
packets Authentication Packets
timers Authentication Timers
vlan Authentication VLANs
FastIron Software Release 08.0.30g Release Notes 79
Defect ID:
DEFECT000557913
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Debug logs does not come in console when named ACL or VLAN-name is send from RADIUS
Condition:
Debug log does not shows up in console after executing the following command
"debug dot1x filter" and "debug dot1x vlan"
Defect ID:
DEFECT000557942
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
IP Source Guard
Symptom:
DHCP snooping entries which are learnt by the switch are cleared upon reloading a stack unit.
Condition:
DHCP snooping entries are learnt on a LAG port and one of the LAG member ports is on the
reloaded stack unit
Defect ID:
DEFECT000558022
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Fitrace for flexauth does not work
Condition:
Fitrace for flexauth does not work even after executing the relevant fitrace commands
After 'debug dot1x port <port-num>' is executed, then fitrace logs shows up console which is not
correct.
Defect ID:
DEFECT000558039
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
At some instanses, snmp walk will fail and Fastiron device may reset
Condition:
During snmp walk Fastiron device may reset
Defect ID:
DEFECT000558226
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
Link Aggregation
Symptom:
The DHCP client is unable to get an IP address from DHCP server.
Condition:
The issue is observed when a DHCP client is connected to the last unit of multi-unit ICX7450 stack
which is in turn connected to the DHCP server through LAG with ports from different units in stack.
Workaround:
Configure LAG with ports from same unit
Defect ID:
DEFECT000558324
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Link Aggregation
Symptom:
The ICX switch reloads at an undetermined scale when keep alive lag is scaled
Condition:
Scaling of the keepalive LAG along one step at a time
FastIron Software Release 08.0.30g Release Notes 80
Defect ID:
DEFECT000558386
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.10
Technology Area:
OSPF (IPv4)
Symptom:
In FastIron device, the OSPF summary LSA's are updated in LSDB with infinite metric.
Condition:
After the reload, OSPF summary LSA's are updated with infinite metric in FastIron device.
Workaround:
Configure static route instead of summary LSA route.
Defect ID:
DEFECT000558545
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
Multicast snooping cache entries does not remove LAG output interface when all the member ports of
trunk move to down state. This is issue with software and does not have any impact on the customer
traffic as this path will not be used as ports are already down.
Condition:
LAG ports present in multicast snooping cache entries are not deleted when all ports of a LAG are
down.
Defect ID:
DEFECT000558546
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
Multicast snooping cache entries does not remove router output interface that are LAG when all the
member ports of trunk move to down state. This is issue with software and does not have any impact
on the customer traffic as this path will not be used as ports are already down.
Condition:
Router ports learnt over LAG that are present in multicast snooping cache entries are not deleted
when all ports of a LAG are down.
Defect ID:
DEFECT000558656
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Component
Symptom:
Port stays down when unplug/plug back the cable b/w Cisco 3850 and ICX-7450 module 2 port (
4X10G copper module)
Steps to reproduce:
1) Unplug the cable either on ICX7450(it is 10G port) or Cisco 3850(it is 1G port) wait for 30 secs
and plug back in and observe port stays down.
This issue can be reproduced in the following conditions;
1) speed auto configured on both sides
2) speed 1000-full configured on brocade device and auto on cisco
3) Speed 1000 configured on cisco side and auto on brocade side
4) Speed configured manually on both the devices.
Condition:
This issue can be reproduced when it is in either of the situation
1) auto negotiation on both sides
2) speed 1000-full configured on brocade device and auto on cisco
3) Speed 1000 configured on cisco side and auto on brocade side
4) Speed configured manually on both the devices
Workaround:
Work around:
1) configure shut/no shut on cisco side
2) configure speed on cisco side or brocade side
FastIron Software Release 08.0.30g Release Notes 81
Defect ID:
DEFECT000558658
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Component
Symptom:
On ICX7450 units, when 4x10T copper module ports are connected back to back, LED's do not stay
lit
Condition:
ICX7450 with 4x10T copper module in slot 2 and cable connected back to back b/w ports on 4X10G
slot 2
Defect ID:
DEFECT000558693
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
"dhcpc: download a specific configuration file. disable PNP" seen on the console after the config file
gets downloaded through auto-config
Condition:
there is no functionality problem for this issue. It should not display this message.
Defect ID:
DEFECT000558701
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Link Aggregation
Symptom:
DO NOT PUBLISH
Condition:
DO NOT PUBLISH
Defect ID:
DEFECT000558710
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
IP Source Guard
Symptom:
Switch unexpectedly reloads when changing the roles of the stack units.
Condition:
Switch has learnt more than 1000 DHCP snooping entries
Workaround:
Clear the learnt DHCP snooping entries before changing stack roles.
Defect ID:
DEFECT000558769
Technical Severity:
Critical
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv6)
Symptom:
DHCPv6 prefix not getting delegated in relay when the state is 'bound' in CPE
Condition:
When DHCP relay is configured on FCX and DHCPv6 server and client are connected to two
different ports
Defect ID:
DEFECT000558846
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
Other IPv4
Symptom:
Traffic drop on for lag ports after lag undeploy.
Condition:
A lag port part of VE is undeployed, the ARP response packets does not reach the CPU.
FastIron Software Release 08.0.30g Release Notes 82
Defect ID:
DEFECT000558890
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Link Aggregation
Symptom:
The ICX switch reloads at an undetermined scale when keep alive lag is scaled
Condition:
Scaling of the keepalive LAG along one step at a time
Defect ID:
DEFECT000558899
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
SSH - Secure Shell
Symptom:
When SSH is done to VRRP-E, it shows in show who even afafter disconnection
Condition:
When SSH is done to VRRP-E, it shows in show who even afafter disconnection
Defect ID:
DEFECT000559035
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 07.3.00
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
Device may unexpectedly reload when interface statistics is fetched through SNMP polling.
Condition:
This issue is observed when IPv6 interface information is fetched for invalid port through SNMP
polling.
Workaround:
Avoid SNMP polling of IPv6 interface statistics with invalid port number.
Defect ID:
DEFECT000559050
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
IP Source Guard
Symptom:
Hardware TCAM entries for IP Source-guard gets corrupted upon clearing learnt DHCP snooping
entries using 'clear dhcp' CLI command
Condition:
DHCP snooping is enabled on vlan and IP Source-guard is enabled on multiple ports
Recovery:
Reload of the switch
Defect ID:
DEFECT000559077
Technical Severity:
Critical
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
when dhcp client enabled with auto-config, system resets
Condition:
Enabling the DHCP client with auto-connfiguration
Defect ID:
DEFECT000559094
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Link Aggregation
Symptom:
L3 unicast traffic doesn't resume for 120sec, when traffic carrying secondary lag port is disabled on
ICX7450 stack
Condition:
On a ICX7450 stack when a traffic carrying secondary lag port which belongs to standby or member
unit is disabled.
FastIron Software Release 08.0.30g Release Notes 83
Defect ID:
DEFECT000559197
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
Flash access locks for 12 minutes
Condition:
When trying to copy non-existent image from disk0 to secondary flash
Defect ID:
DEFECT000559256
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
On ICX stack, if flex authentication is enabled and there are traffic to clients on member units, then
after stack switchover, traffic to some clients on members will be software forwarded by CPU instead
of hardware forwarding. If traffic speed is high, CPU usage will be high and traffic will be dropped.
Condition:
1: On ICX 3(or more than 3) units stack
2: Flex authentication is enabled
3: There are clients connecting through member units
4: It is triggered by stack switchover.
Recovery:
Do "clean arp" on new master after switchover
Defect ID:
DEFECT000559290
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Mac-authentication cannot be configured on a port which has mirroring enabled.
Condition:
If port mirroring is enabled on a port and then MAC Authentication is attempted, this issue is
observed.
Defect ID:
DEFECT000559323
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
802.1x clients are not authorized and stuck in AUTHENTICATING state.
Condition:
802.1x authentication enabled, the configuration is changed from single-untagged-mode to multi-
untagged-mode.
Defect ID:
DEFECT000559403
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
DHCP (IPv4)
Symptom:
In ICX6450, DHCP server locks up when offering IP addresses.
Condition:
When the client requested IP address is excluded in the DHCP Server' address pool, DHCP server
will hit high CPU and locks up for couple of minutes.
FastIron Software Release 08.0.30g Release Notes 84
Defect ID:
DEFECT000559418
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
PoE/PoE+
Symptom:
PoE capable ICX7250's connected to an EPS are getting 360W allocated per EPS channel. Expected
is 370W.
Condition:
ICX7250-48P, ICX7250-24P connected to EPS
Workaround:
PoE is functional. Missing 10W per EPS channel. No workaround for a minimum of a 10-20W
deficit.
Defect ID:
DEFECT000559446
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
Other IPv6
Symptom:
ICX6450 will not respond to externally originated IPv6 pings.
Condition:
ICX6450 will not respond to externally originated IPv6 pings through management port.
Defect ID:
DEFECT000559484
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
VE configuration does not take effect and VE is not created.
Condition:
A VE in a system without ports and a flex auth feature is expected to add ports to the VE.
Recovery:
once you run into this situation, remove router interface configuration and re apply it. it will solve the
issue.
Defect ID:
DEFECT000559618
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
IEEE 802.1w RSTP
Symptom:
On enabling span/802.1W protocol on authentication default vlan, switch can un-expectedly reload on
issuing any span/802.1W commands at VLAN level (or) at interface level.
Condition:
With Flex authentication feature enabled the device reload with certain spanning tree /rapid spanning
tree configuration.
Defect ID:
DEFECT000559663
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
Web Management
Symptom:
Web interface allows to change stack MAC address from even if if SNMPv3 users a present
Condition:
Web interface allows to change stack MAC address from even if if SNMPv3 users a present
FastIron Software Release 08.0.30g Release Notes 85
Defect ID:
DEFECT000559686
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
Sensitive Protocols like UDLD, VRRP state changes (flaps) occur when supportsave CLI command is
executed to collect debugging information from the Switch.
The problem occurs when supportsave CLI command is used with the "all" option.
Condition:
Issue is usually observed in time sensitive protocols like UDLD/VRRP with the number of
UDLD/VRRP instances being 10 or more.
Workaround:
There are two work arounds for this:
1. supportsave command used for collecting debugging information needs to be executed only in
maintenance window.
2. Execute supportsave with specific sub-options pertaining to the issue being debugged rather
than giving "all" option.
Defect ID:
DEFECT000559758
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
After switch-over few users are not authenticated again when the number of users are scaled to 1536
Condition:
1536 Users are mac-authenticated in a stacking system. Then switch-over is triggered by changing the
priority of the stack units.
Defect ID:
DEFECT000559795
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
SSH output slows down noticeably
Condition:
When skip-page-display is enabled or a command is run that does not paginate, SSH output slows
down.
Defect ID:
DEFECT000559826
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
Web Management
Symptom:
when pressing the modify button on WEB lag page without changing any parameters, LAG ports go
down.
Condition:
when pressing the modify button on WEB lag page without changing any parameters, LAG ports go
down.
Defect ID:
DEFECT000560016
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Multi-Chassis Trunking
Symptom:
In MCT deployment, a configured static mac address is allowed to move to a new port as a secure
mac address when the same mac address is received on a PMS enabled port but the peer mct device
still shows the static mac address on the old port on which it was initially configured.
Condition:
A configured static mac address moves as a secure mac address to a PMS enabled port & this mac
address move does not take effect on the mct peer. This is fixed in 8.0.30b
FastIron Software Release 08.0.30g Release Notes 86
Defect ID:
DEFECT000560078
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The 802.1x capable clients are not implicitly authenticated when there is no response from Radius-
servers and "aaa authentication dot1x default radius none" command is configured.
Condition:
The FI device has "aaa authentication dot1x default radius none" configuration and 802.1x is enabled
on the interface.
Defect ID:
DEFECT000560108
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
On reload, many of the configured users are not authenticated when the number of users are scaled to
1524
Condition:
1524 Users are configured to be authenticated using both mac-authentication & 802.1X on the device.
Defect ID:
DEFECT000560139
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
QnQ
Symptom:
PVST PDUs are not SW forwarded, when spanning tree is disabled on the ICX7450 resulting in
PVST/spanning tree not converging.
Condition:
ICX7450 configured to perform QinQ double tagged PVST, with spanning tree disabled globally.
Defect ID:
DEFECT000560155
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
SSH - Secure Shell
Symptom:
If multiple SSH sessions are attempted at the same time to a ICX 7450 Stack, the stack may reset
Condition:
If multiple SSH sessions are attempted at the same time to a ICX 7450 Stack, the stack may reset
Defect ID:
DEFECT000560190
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
Security Vulnerability
Symptom:
ACL's deny rule is not honored for ingress packets.
Condition:
In ICX7750 stacking, when the packet's ingress and egress ports are in different units, the ACL rule to
deny ingress packets is not honored.
Defect ID:
DEFECT000560313
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
The CLI of DHCP server goes unresponsive for couple of minutes.
Condition:
When DHCP client is renewing a lease of IP address which was excluded in the DHCP server'
address pool, then the CPU usage goes high and causes CLI to be unresponsive.
FastIron Software Release 08.0.30g Release Notes 87
Defect ID:
DEFECT000560320
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
Customer may observe that "ip multicast age-interval" configuration is getting applied across
reboots.
Condition:
The "ip multicast age-interval" configuration may not get reapplied when system is rebooted if
parameters such as query interval, robustness are also configured.
Defect ID:
DEFECT000560358
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
"ERROR: Insufficient hardware resource for binding the ACL to interface <port>" message is
displayed while adding ACL rules.
Condition:
Adding new ACL rule even when the number of rules in ACL is less than ip-port-filter parameter.
Defect ID:
DEFECT000560395
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
entering interface level mode for 10 g displays the interface mode twice
Condition:
entering interface level mode for 10 g displays the interface mode twice
Defect ID:
DEFECT000560410
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Unexpected reload during switchover
Condition:
When users are authenticating during a switchover this could be seen
Workaround:
Fixed
Recovery:
Fixed
Defect ID:
DEFECT000560443
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
DAI - Dynamic ARP Inspection
Symptom:
Switch unexpectedly reloads after a stack switch-over
Condition:
DHCPv6 snooping is enabled and the switch has learnt more than 1000 DHCPv6 snoop entries.
Defect ID:
DEFECT000560446
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
SSH - Secure Shell
Symptom:
The ip ssh source-interface command was not available on Fastiron devices.
Condition:
The ip ssh source-interface command was not available on Fastiron devices.
FastIron Software Release 08.0.30g Release Notes 88
Defect ID:
DEFECT000560472
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
xwindow-manager support is not available in system
Condition:
Option 49 support available for DHCP-server in FastIron devices
Defect ID:
DEFECT000560566
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Monitoring/RAS
Reported In Release:
FI 08.0.30
Technology Area:
Port Mirroring and Monitoring
Symptom:
When Port Mirroring is enabled on the primary port of a LAG, it automatically enables it on all LAG
ports. When the LAG is undeployed, the mirroring will be removed. It is expected that mirroring will
not be enabled automatically when the LAG is deployed again. However, in this defect, we were
observing that when the LAG is deployed again, mirroring was getting enabled.
Condition:
This issue will be seen when LAG configuration is being updeployed and deployed consecutively.
Defect ID:
DEFECT000560605
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
Member stack unit gets stuck at synchronization forever when trying to add it back to the stack by
"stack enable".
Condition:
"stack unconfigure me" on member unit followed by stack enable on it.
Recovery:
Reload the entire stack.
Defect ID:
DEFECT000560650
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
1G-Copper SFP ports on ICX7750 will always show linked up but no traffic will pass on this port.
Condition:
1G-Copper SFP ports on ICX7750 will show up even the the peer port unit ICX7750 is reloaded
Defect ID:
DEFECT000560660
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
Flash access locks console for 12 minutes
Condition:
When trying to copy SSL-Trust-Certificate from Disk0
Defect ID:
DEFECT000560665
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Authentication of 802.1x capable clients fails when interface is in single-untagged mode.
Condition:
When the auth-mode of 802.1x authentication enabled interface is changed from multiple untagged
mode to single untagged mode, dot1x authentication fails.
FastIron Software Release 08.0.30g Release Notes 89
Defect ID:
DEFECT000560756
Technical Severity:
Critical
Probability:
Low
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
MAC ACLs
Symptom:
Switch unexpectedly reloaded while applying MAC filter-group on a port
Condition:
MAC filter-group had multiple filters
Defect ID:
DEFECT000560758
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
Sometime when the SXL is loaded with 8.0.30 image then the system reloads unexpectedbly with
following trace on console:
stack: 10b068b8 00100350 10b06854 104a4db0 10d10540 10d118d4 10d0b2b8 10d0b0f4 10bcba74
10497568 1056e110 10579cf0 10c26ce4 10dc02a4 11dcad28 11e0f404
Condition:
Sometime when the SXL is loaded with 8.0.30 image then the system reloads
Defect ID:
DEFECT000560817
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Unexpected reload observed on ICX7xxx series devices
Condition:
Active & standby module is changed due to priority changes of stack units and there are 1500
Flexauth sessions on the system
Defect ID:
DEFECT000560955
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
"mac-authentication password-format xxxxxxxxxxxx upper-case" command is not removed even after
all global authentication configuration is removed
Condition:
Admin configured the following command for flexauth
'mac-authentication password-format xxxxxxxxxxxx upper-case'
However, the same command cannot be removed even after doing 'no authentication' at global level
Defect ID:
DEFECT000560971
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
AAA Accounting start and stop packets are not sent to IPv6 Radius-server.
Condition:
FI device has IPv6 Radius-server configuration..
Defect ID:
DEFECT000560994
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
After multiple switchovers users are not mac-authenticated.
Condition:
'auth-vlan-mode multiple-untagged' is configured globally. Auth-order is 802.1X followed by Mac-
authentication. 1536 Users are authenticated using mac-authentication since Users are 802.1X
incapable. After multiple switch-over these users are not mac-authenticated
FastIron Software Release 08.0.30g Release Notes 90
Defect ID:
DEFECT000561089
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Routing
Symptom:
After changing default VLAN on fly in ICX7450, forwarding of IPv4/IPv6 multicast traffic received
on physical IP interfaces may fail.
Condition:
This happens only if IPv4/IPv6 multicast routing is enabled on Physical IP interfaces prior to the
change of default VLAN.
Defect ID:
DEFECT000561139
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
1G LAG between MLX bow card and ICX7450 does not come up.
Condition:
Create a 1G LAG between MLX bow card and ICX7460 unit. Deploy the LAG.
Recovery:
Save the configuration and reload the units.
Defect ID:
DEFECT000561270
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
ICX7250 1G Copper port with Auto speed is not linking up with a peer of 10/10M Half
Condition:
Connect the ICX7250 1G Copper port of auto speed to a peer of 10/100M Half
Defect ID:
DEFECT000561289
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Upon reload the flexauth enabled port becomes member of both global & local auth--default-vlan
Condition:
Both global and local auth-default-vlan is configured and then device is reloaded.
Defect ID:
DEFECT000561326
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
SSH - Secure Shell
Symptom:
SSH Client not getting connected for the first time when Radius Authentication is used.
Condition:
SSH login failure
Defect ID:
DEFECT000561555
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
When Radius authentication times out, 802.1x client is not authorized based on auth-timeout-action
configuration.
Condition:
802.1x is enabled on the port and auth-timeout-action is configured. The Authentication request for
802.1x client gets timed out due to network reachability.
FastIron Software Release 08.0.30g Release Notes 91
Defect ID:
DEFECT000561683
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
On ICX7250 ,when a 1G Copper SFP is plugged in to a 10G port ,the link does not come up .
Condition:
Reload a fresh ICX7250
Configure the speed 1G full on a 10G port
Hot plug a 1G Copper SFP
Recovery:
Reload of ICX7250
Defect ID:
DEFECT000561695
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Unexpected reload on port enable/disable after MAC Auth
Condition:
256 User are mac-authenticated on a port. Port is disabled & enabled.
Defect ID:
DEFECT000561701
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
FI device may unexpectedly reload with different stack traces, when 802.1x authentication and 802.1x
accounting are enabled.
Condition:
802.1x authentication and accounting are enabled, with many 802.1x capable clients authorized on the
FI device.
Defect ID:
DEFECT000561828
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
The clients are not reachable after authenticated through mac-authentication or 802.1x authentication
methods.
Condition:
When auth-default-vlan is configured at interface level, the 802.1x client becomes unreachable after
authentication.
Defect ID:
DEFECT000561830
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
The LEDs of port x/2/5 to x/2/8 of ICX7250-48 and ICX7250-48P could get lit, even when the ports
are down.
Condition:
The LEDs of port x/2/5 to x/2/8 are incorrectly mapped to x/1/35 to x/1/38 in case of ICX7250-48 and
ICX7250-48P. If the ports x/1/35 to 38 is up, this could light the LEDs of port x/2/5 to x/2/8
Workaround:
No workaround.
Recovery:
This is fixed in 8.0.30b patch.
FastIron Software Release 08.0.30g Release Notes 92
Defect ID:
DEFECT000561838
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Unexpected reload on clear dot1x session command
Condition:
256 User are authenticated using 802.1X. If those authenticated sessions are cleared by using
command 'clear dot1x session, this reload is observed.
Defect ID:
DEFECT000561940
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 07.3.00
Technology Area:
Component
Symptom:
The port transitions and incrementing InErrors are seen on 10G ports of ICX6450-24.
Condition:
When Jumbo frames is enabled in ICX6450-24, the port transitions and incrementing InErrors are
seen on 10G ports of ICX6450-24.
Defect ID:
DEFECT000562024
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
On a ICX-7450 stacking setup user will not able to configure the speed on a ICX7450-48F member
unit port with copper SFP .
Condition:
If the ICX7450-48F unit is a standby or member unit and speed setting is changed for the ports with
SFP
Workaround:
On stacking environment configure the ICX7450-48F unit as active to change the speed of a port
with copper SFP.
Recovery:
Change the role of ICX7450-48F as active if its a standby or member unit
Defect ID:
DEFECT000562179
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
IP Source Guard
Symptom:
Software TCAM entries for stack active and standby units are not in sync after a DHCP snoop entry is
learnt or a static IP Source guard binding is configured
Condition:
DHCP snooping is enabled on vlan, IP Source-guard is configured on the port and the switch is
reloaded with these settings.
Issue is seen on Layer 2 software image
Recovery:
Write mem and reload
Defect ID:
DEFECT000562187
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
In support save when hardware routes are getting displayed, the device may reset
Condition:
In support save when hardware routes are getting displayed, the device may reset
FastIron Software Release 08.0.30g Release Notes 93
Defect ID:
DEFECT000562360
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
On a ICX7250/ICX7750 with copper SFP optic, port will show up even if the peer port is disabled.
Condition:
Connect the port of ICX7250/ICX7750 with copper SFP to a peer port with copper SFP. Disable the
peer port.
Defect ID:
DEFECT000562364
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
The IF-MIB reports less number of interfaces than actual interfaces present in the system.
Condition:
The IF-MIB does not report management interface.
Defect ID:
DEFECT000562372
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
Port down on x/2/1 - x/2/4 with copper SFP and configured to 1000-full
Condition:
Configuring the speed to 1000-full, the ports link up with 1G speed. After the config is saved do a
reload
Workaround:
Do not reload the setup.
Recovery:
Configure the port speed again to "1000-full" after a reload.
Defect ID:
DEFECT000562452
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
IP Source Guard
Symptom:
Software TCAM entries for stack active and standby units are not in sync after the stack is reloaded.
Condition:
DHCP snooping is enabled on vlan and the switch has learnt some DHCP snoop entries, IP Source-
guard is configured on the port and the switch is reloaded with these settings.
Defect ID:
DEFECT000562585
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Syslog is not observed when 802.1X re-authentication is being done for ports on stacking member
units
Condition:
When member ports are being authenticated using 802.1x
Defect ID:
DEFECT000562678
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
SSH - Secure Shell
Symptom:
SSH server stop responding at times
Condition:
Fastiron Device does not allow user to login using SSH some times
FastIron Software Release 08.0.30g Release Notes 94
Defect ID:
DEFECT000562679
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
"no 100-fx" command execution throws "Error: 100-fx command not applicable for port"
Condition:
Upgrade from 7.x to 8.x versions with 100-fx command configured in 7.x. Execution of "no 100-fx"
command.
Defect ID:
DEFECT000562714
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Two disabled-ageing commands executed from CLI shows up in running config incorrectly
Condition:
Configure disable-aging at global or interface level, cli takes the command as "disable-aging denied-
mac-only" but in show run it displays as "disable-aging denied-mac" .
same applicable for permitted-mac.
SWDR_STACK(config-authen)#disable-aging
denied-mac-only Disable aging of Denied MAC sessions only
permitted-mac-only Disable aging of Permitted MAC sessions only
After the fix, 'disable-aging denied-mac-only' is shown in running config. Same is true for permitted
MACs
Defect ID:
DEFECT000562899
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
Unexpected reload of ICX7450 after a configuration file erase followed by a reload
Condition:
1. Do a Config file erase from CLI
2. Reload ICX7450
Defect ID:
DEFECT000562908
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
On ICX 7250 stack when the speed is forced to 10/100 M full , the duplex is getting wrongly
displayed as 10/100M half
Condition:
1, Force the ICX7250 to 10/100M full
2. Check the Duplex settings
Defect ID:
DEFECT000563013
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
ICX7250 1G Copper port with Auto speed settings will not link up when connected to a Laptop port
Condition:
Connect the ICX7250 1G copper port with auto speed settings to a Laptop ethernet interface
FastIron Software Release 08.0.30g Release Notes 95
Defect ID:
DEFECT000563083
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
The ICX7450 1G copper port with auto speed settings will link up as 10-half when connected to a
10-full peer
Condition:
Connect the IC7450 1G port with auto speed to a peer with 10-full configuration
Defect ID:
DEFECT000563103
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
ICX7450 port will not link up after a reload, when it is connected to a fixed speed peer
Condition:
1. Connect the ICX7450 1G copper port with auto speed to a peer port which has fixed speed
2. Reload the ICX7450 , the port connected to the fixed peer will not come up.
Defect ID:
DEFECT000563198
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
Unexpected Reload of ICX7450, when all the interfaces are disabled by the disable command
Condition:
Reload ICX7450 and then Issue Disable on all the Ports
Defect ID:
DEFECT000563259
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
1G Copper ports of ICX7250 connected to 1G copper ports of ICX6610 does not link up after reload
Condition:
Connect the 1G ports of ICX7250 to the 1G ports of ICX6610.
Reload ICX6610, link is down after the reload
Defect ID:
DEFECT000563283
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
DAI - Dynamic ARP Inspection
Symptom:
The stack unit might see an unexpected reboot when the config has vlan 4095 configured as default
VLAN and config includes DHCP Snooping/ARP inspection on this vlan.
Condition:
The user needs to have config which has vlan 4095, which is configured as default VLAN. Also,
DHCP Snooping/ARP Inspection needs to be enabled.
Defect ID:
DEFECT000563313
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
After "speed-duplex 1000-full-slave/master" configuration is applied to 10G copper ports on ICX-
7750 and a reload is done, the ports get configured to default speed "10g-full".
Condition:
"speed-duplex 1000-full-slave/master" configuration applied to 10G copper ports on ICX-7750.
Workaround:
Do not reload the setup if you want to run the port on speed "speed-duplex 1000-full-
slave/master" .
Recovery:
Configure the port speed "speed-duplex 1000-full-slave/master" every time after a reload.
FastIron Software Release 08.0.30g Release Notes 96
Defect ID:
DEFECT000563325
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
If authentication [either 802.1X or mac-authentication] process starts during reload, traffic loss is
observed from the authenticated users after all users are authenticated
Condition:
When 32x4 Users are authenticated during reload on 4 different ports on 4 Unit-stack where each port
is having 32 Users. Each port is from different stack Unit. Each User has dynamic ACL.
Defect ID:
DEFECT000563394
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
ICX7450 1G port will not link up when configured as 1000-FULL-MASTER , when connected to a
peer with 1000-FULL-SLAVE
Condition:
Configure ICX7450 port as 1000-full-master
connect this to a peer port with setting 1000-full-slave
the port will not link up
Defect ID:
DEFECT000563397
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
ICX7450 1G Copper port does not display correct speed, when connected to a peer whose speed is
changed dynamically
Condition:
Connect ICX7450 1G Copper port to a peer
Change the peer port speed
Check if the ICX7450 displays proper speed
Defect ID:
DEFECT000563399
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
In ICX7450 stack device, error messages are printed in the console when stacking is enabled.
Condition:
When stacking is enabled in ICX7450 device, the error messages are printed in the console.
Defect ID:
DEFECT000563540
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
On re-authentication of MAC authenticated clients, the port membership is removed from
dynamically assigned Tagged VLAN.
Condition:
Clients are authenticated using MAC authentication. While authenticating the clients Radius-server
sends T:VLAN-ID, Session-timeout and termination-action attributes. Termination-action is set as
Radius-Request.
FastIron Software Release 08.0.30g Release Notes 97
Defect ID:
DEFECT000563699
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
On ICX7250, the 10G ports with 1G SFP/copper SFP will be down after a reload.
Condition:
If user configures the 10G port with 1G SFP/copper SFP to 1000-full speed, the config file does not
get updated. Hence after a reload the ports will get configured to default sped 10G
Workaround:
Do not reload the setup after speed change.
Recovery:
Do speed configuration every time the setup is reloaded.
Defect ID:
DEFECT000563806
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
IP address is not shown for an authenticated user in the "show dot1x session all" command
Condition:
In a 3 Unit-stack, one of the unit did not come up and it is down. Seen when an user is being
authenticated with Dynamic ACL with either 802.1x or mac-authentication.
Defect ID:
DEFECT000563809
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
ICX-7750: On a 10G fiber port configured with "Speed-duplex 1000-full" and configuration saved,
the configuration is lost on Reload.
Condition:
ICX-7750: Configure "Speed-duplex 1000-full" on a 10G fiber port and the configuration does not
get updated in configuration
Workaround:
Don't reload the setup after setting the speed to "Speed-duplex 1000-full".
Recovery:
User has to apply the command "Speed-duplex 1000-full" every time after reload if he wants to use
the port at 1G speed. Or Software upgrade is required to resolve the issue.
Defect ID:
DEFECT000564048
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
The ICX6450-48F 1G fiber port connected with 100FX optics does not link up with another device
after switch reload.
Condition:
The ICX6450-48F 1G fiber port connected with 100FX optics does not link up with other device after
switch reload.
Defect ID:
DEFECT000564277
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Device unexpectedly reloads
Condition:
When the following hidden command is used to configure max-session for a group of mac-
authentication enabled ports, device reloads unexpectedly
ICX6610(config-mif-1/1/15,2/1/15)#mac-auth max-accepted-session 10
FastIron Software Release 08.0.30g Release Notes 98
Defect ID:
DEFECT000564366
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
Enabling DHCP auto-config may cause system-reset
Condition:
Enabling DHCP auto-config may cause system-reset
Closed defects with code changes in Release 08.0.30aa
This section lists defects closed with code changes in in the 08.0.30aa release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000553444
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.20
Technology Area:
Traditional Stacking
Symptom:
In ICX7450 or 7750 stack, outgoing IP packets from standby/member unit are updated with the
source MAC of the unit's mac-address instead of stack MAC
Condition:
This issue is seen with 7450 or 7750 stack units after a reload, with stack mac not synchronized to
standby and member unit.
Workaround:
Disable standby stack unit
Closed defects with code changes in Release 08.0.30a
This section lists defects closed with code changes in in the 08.0.30a release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000533964
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Web Management
Symptom:
In the ICX device, establishing an HTTPs session using Firefox browser with TACACS+
authentication may result in unexpected reload of the device.
Condition:
This issue happens when establishing an HTTPS session using Firefox browser with TACACS+
authentication.
FastIron Software Release 08.0.30g Release Notes 99
Defect ID:
DEFECT000552094
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
The ICX7750 may get automatically reloaded after system boot up with the following error messages,
FATAL MISMATCH: FRU fans do not have same air-flow direction!!!
System will shutdown in 301 seconds!!!
Condition:
The FAN direction is detected incorrectly which triggered the fatal mismatch condition hence system
was reloaded automatically.
Defect ID:
DEFECT000552097
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
EPS2 LED could bleed into Master LED in some of the ICX7250 models
Condition:
Some of the ICX7250 models do not support second EPS. But the LED for EPS 2 could be lit and the
light could bleed into the nearby indicator
Defect ID:
DEFECT000552672
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
The speed-duplex 100-full config is not getting saved after reload.
Condition:
The speed-duplex config for 100M full is not getting saved after reload.
Workaround:
Reconfigure the speed 100-full command again for those ports after reload.
Defect ID:
DEFECT000553362
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
The ICX7750 module 2 ports remains down when it is connected with 40GE QSFP+ LR4 optics.
Condition:
When LR4 optics are inserted in port 1/2/5 and 1/2/6, it is not getting configured properly hence the
port remains down.
Defect ID:
DEFECT000553449
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Customer experienced automatic reset of ICX6450 in some corner case scenario with the flexauth
configuration.
Condition:
Customer experienced automatic reset of ICX6450 with the flexauth configuration including 802.1x
authentication. In some corner case scenarios MAC session got cleared which triggered this automatic
reload.
FastIron Software Release 08.0.30g Release Notes 100
Closed defects with code changes in Release 08.0.30
This section lists defects closed with code changes in in the 08.0.30 release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000473881
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 07.4.00
Technology Area:
IPv4/IPv6 Host Management
Symptom:
FastIron ICX64xx treats 09:09:09 as 00:00:00 in the "reload after" command.
Condition:
When the command " reload after 08:08:08 or 09:09:09 " is triggered, the device takes it as "reload
after 00:00:00"
Workaround:
use anything other than 08:08:08 or 09:09:09 for the reload after command.
Defect ID:
DEFECT000491696
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.4.00
Technology Area:
Link Aggregation
Symptom:
New DHCP client does not obtain IP address, if it is connected after the active unit of the ICX stack
device powers down.
Condition:
After the ICX stack's active unit power down and with no stack MAC configured, the newly
connected DHCP client would not obtain IP from the device.
Workaround:
Configure stack MAC or have hitless enable by default on.
Defect ID:
DEFECT000495058
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.10
Technology Area:
Hitless Switchover, Failover,
Hotswap, OS U/G
Symptom:
Keepalive LAG on new active of ICX stack flaps, when standby unit (old active) joins the stack after
stack failover.
Condition:
When the keepalive LAG is created between ICX6610 and MLX, it flaps the LAG on the active unit
of the ICX device when standby unit (old active) joins the stack after stack failover.
Defect ID:
DEFECT000496205
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.00
Technology Area:
Multi-Chassis Trunking
Symptom:
Ping latency and high CPU were observed in MCT setup using two FI devices.
Condition:
When a MCT cluster is configured on a two device MCT setup, more number of nexthop router
movement messages was observed leading to high CPU.
Defect ID:
DEFECT000497211
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.01
Technology Area:
DHCP (IPv4)
Symptom:
ICX device will stall for couple of minutes with console freeze and high CPU when a Windows 7
based DHCP client is moved across VLANs.
Condition:
Windows 7 based DHCP client moving across VLANs on a ICX6450
FastIron Software Release 08.0.30g Release Notes 101
Defect ID:
DEFECT000512781
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.01
Technology Area:
Link Aggregation
Symptom:
When the active of ICX6450 stack device powers down, actor system ID changes in LACPDUs
causing links flap
Condition:
With "use-local-mgmt-mac" configured, link flaps will happen when active ICX6450 stack device
powers down and actor system ID changes in LACPDUs.
Workaround:
Configure a random stack mac not associated with the physical units in the stack
Defect ID:
DEFECT000514766
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.5.00
Technology Area:
MRP - Metro Ring Protocol
Symptom:
In ICX6650 device, CPU goes high and console freezes when VLANs are added to topology group
of the MRP ring-switches.
Condition:
This issue occurs only when the user tries to add 4000 VLANs as member of a topology group.
Workaround:
Avoid using large vlan range in the member-vlan CLI especially on the MRP ring interfaces.
Defect ID:
DEFECT000519552
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
DHCP (IPv4)
Symptom:
CPU shoots to 99% when laptop running windows7 is directly connected to ICX6450 to get dynamic
IP address
Condition:
When the laptop running Windows7 is directly connected to ICX6450 to get dynamic IP, CPU shoots
to 99% and the console is hung for few minutes and then back to normal.
Defect ID:
DEFECT000522537
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.00
Technology Area:
SSH - Secure Shell
Symptom:
Memory usage increases by 1% in for every 10 days in FastIron devices while using openNMS tool
which polls the device in regular intervals resulting in insufficient memory for other applications.
Condition:
Memory leak in FastIron devices can be observed only when the device is polled with openNMS tool
that uses SSH for every 5 mins.
Defect ID:
DEFECT000522650
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
Security
Reported In Release:
FI 07.3.00
Technology Area:
802.1x Port Security
Symptom:
IP phones unexpectedly losing connection when 802.1x is enabled after about 10 minutes in FastIron
devices.
Condition:
The connectivity loss happens only in dual-mode vlan, where the phone is tagged to voice-vlan, while
the dot1x mac-session is associated with the data-vlan.
Workaround:
Enable dot1x multicast mode on the phone.
FastIron Software Release 08.0.30g Release Notes 102
Defect ID:
DEFECT000522949
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 07.4.00
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
Brocade ICX6450 stack members may not be updated correctly if Firmware Download is done
through Brocade Network Advisor.
Condition:
Firmware Download using Brocade Network Advisor may fails to upgrade stack members for
Brocade ICX6450
Workaround:
The workaround is to wait for 5 minutes before issuing a reload after the image copy is completed.
Defect ID:
DEFECT000523046
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
SFLOW
Symptom:
"show sflow" display module sampling rates as "slot x ....." even for stacking devices.
Condition:
No specific pre-conditions , display will always show as "slot" instead of unit and module number.
Workaround:
No Workaround this is just a display change required.
Recovery:
Not applicable - Display change required.
Defect ID:
DEFECT000523352
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
SX800-SX1600 10Gbps links randomly drop casuing STP/RSTP TCNS with Jumbo enabled
Condition:
Customer has large Layer 2 Network with 4 SX800 devices running MCT.
Defect ID:
DEFECT000524142
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
Customer seeing InErrors on 10Gbps links which is causing logical link flaps
Condition:
In some cases the 10Gbps logical link flap was observed in a connection between ICX6610 and
ICX7750
Workaround:
The issue has been resolved in the current release. There is no workaround without this fix
Recovery:
There is no recovery procedure for this issue but this issue has been resolved in this release
Defect ID:
DEFECT000524238
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Monitoring/RAS
Reported In Release:
FI 08.0.20
Technology Area:
Port Mirroring and Monitoring
Symptom:
CPU generated packets such as LLDP and EAP when transmitted out of ICX7450 and ICX7750
ports that are enabled for egress mirroring to another port do not mirror packets to that port.
Condition:
A port is configured as a mirror port for egress mirroring. Another port is configured as a monitor
port for mirroring egress traffic to the mirror port. The monitor port is enabled for 802.1x and/or
LLDP.
FastIron Software Release 08.0.30g Release Notes 103
Defect ID:
DEFECT000524488
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
Other IPv6
Symptom:
In a default vlan flooding shall happen if a IPV6 reserved multicast address packets are received on a
layer 3 physical interface
Condition:
IPv6 reserved multicast packets received on a default vlan on a physical l3 port.
Defect ID:
DEFECT000524539
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 07.4.00
Technology Area:
IPv4 Multicast Switching
Symptom:
There is an intermittent loss of multicast traffic when traffic is forwarded through the stacking link of
a Stack.
Condition:
This issue is seen when multiple operations are done on an entry, such as addition and removal of port
from forwarding entry.
Defect ID:
DEFECT000524869
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
ACLs (IPv4)
Symptom:
When a large ACL is applied on a member and standby ports of ICX7750 or ICX7450 stack and then
stack is reloaded, error messages similar to following are seen on the member or standby unit:
UNIT1:M:acl S:stacking L:0 - acl_stacking_member_acldevAddFeature: Failed to program IPv4
filter296 [ACL-ID: 0] in member
The ACL may not be properly programmed on the member or standby unit.
Condition:
When the stack is reloaded after applying large ACL on members and standby ports of ICX7750 or
ICX7450, error messages related to 'IPV4 filter' will be seen.
Workaround:
If the ACL is not properly working In the above scenario, un-configuring and configuring again
will solve the issue.
Defect ID:
DEFECT000525122
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
When returning a MAC filter from Radius for a client, the syslog message is incorrect as it states that
the MAC filter was added for a user in console session, even if the user is not logged in through
console session.
Condition:
1) Enable syslog and for a 802.1x client, return a MAC filter from Radius.
Defect ID:
DEFECT000526416
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
Other IPv4
Symptom:
Mutticast traffic drops for a group that has 2 or more receivers when one of the receivers leaves that
group that belongs to the same vlan.
Condition:
This scenario comes in to play only on a port that is connected to shared lan segment. This issue is
NOT seen on P2P full duplex links
Workaround:
However if there is such a deployment then we could enable "igmp host-tracking" feature to
cicumvent this.
FastIron Software Release 08.0.30g Release Notes 104
Defect ID:
DEFECT000526465
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.01
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
Brocade ICX6430 switch may boot with corrupted flash image when the boot image is pushed
through Brocade Network Advisor.
Condition:
Brocade ICX6430 switch may have problem in booting. Where switch was running Fi7.4 and upgrade
to FI80.0.1 boot image through Brocade Network Advisor
Workaround:
Workaround solution is that the user may wait 5-10 minutes to make sure BNA reports the copy
operation successfully, then reload the system.
Defect ID:
DEFECT000526521
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
On ICX6450, when there is a conflict involving having a dynamic ACL and dynamic MAC filter on
the port returned for multiple clients, the error message printed is incomplete. There is no functional
impact.
Condition:
1) If there are two dot1x clients on the port and a dynamic ACL is returned for one client, and a MAC
filter for another client from Radius during authentication.
Defect will be seen during authentication for both clients.
Defect ID:
DEFECT000526605
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.20
Technology Area:
Secure Setup, Autoconfig, Manifest
files, Autocopy
Symptom:
- Form a stack in ring topology.
- Covert the ring topology in to a linear by removing one of the stack-port on a unit.
- Now run secure-setup and convert the topology back to ring.
- After that, a stack-trunk may not be configured even if secondary stack-ports are connected.
- Only if secure-setup is run again (2nd time), the correct stack-trunks are discovered.
Condition:
- Form a stack in ring topology.
- Covert the ring topology in to a linear by removing one of the stack-port on a unit.
- Now run secure-setup and convert the topology back to ring.
- After that, a stack-trunk may not be configured even if secondary stack-ports are connected.
- Only if secure-setup is run again (2nd time), the correct stack-trunks are discovered.
Workaround:
Create the stack from scratch using secure-setup or manual-stack-formation.
Recovery:
multi-stack-trunk or stack-trunk commands can be used to update the configuration.
Defect ID:
DEFECT000526857
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
On ICX7750, after authenticating a 802.1x client with a Radius dynamic VLAN and dynamic ACL,
after a switchover, EAP requests may not be sent to the client and 802.1x may not be performed.
Condition:
On ICX7750, after authenticating a 802.1x client with a Radius dynamic VLAN and dynamic ACL,
after a switchover, EAP requests may not be sent to the client and 802.1x may not be performed.
Workaround:
After the initial switchover and the stack is stable, perform another switchover and notice that
EAP request is sent out again and 802.1x is performed.
FastIron Software Release 08.0.30g Release Notes 105
Defect ID:
DEFECT000526892
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.4.00
Technology Area:
UDLD - Uni-Directional Link
Detection
Symptom:
In a Switch/Router configured with UDLD, if a flap is seen, the debug counter can be used to isolate
the cause of flap.
Condition:
The UDLD flap could be caused due to either UDLD packet is not received, or it was not sent out.
Defect ID:
DEFECT000526954
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
In a stacking environment with 3+ units and MDPA and 802.1x ports across active,standby, and
member units, upon a stack priority change where the member units have higher priority than the
current active and standby, traffic will not be forwarded for ports in member units.
Condition:
In a stacking environment with 3+ units and MDPA and 802.1x ports across active,standby, and
member units, upon a stack priority change where the member units have higher priority than the
current active and standby, traffic will not be forwarded for ports in member units.
Defect ID:
DEFECT000527210
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
In a stacking environment with 3+ units, and MDPA enabled ports across all units, after a failover
where the failed unit recovers and becomes a member unit, the MDPA clients on the new member
unit will not be authenticated.
Condition:
In a stacking environment with 3+ units, and MDPA enabled ports across all units, after a failover
where the failed unit recovers and becomes a member unit, the MDPA clients on the new member
unit will not be authenticated.
Defect ID:
DEFECT000527447
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.10
Technology Area:
Receive ACLs
Symptom:
ACL may not block the request from a non-established TCP conversation to an internal IP.
Condition:
ACL that matches all TCP packets after the session has established is not working as expected.
Workaround:
More specfic ACL can be configured to work in all cases.
Defect ID:
DEFECT000527867
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.20
Technology Area:
IPv6 Multicast Switching
Symptom:
Multicast Layer 2 IPv6 entries may not age out after flow stops.
Condition:
When Multicast Layer 2 IPv6 flow stops, the corresponding entry should be deleted in matter of time.
However, if MLDv1 reports keep arriving for the same group then entry may not age out.
Workaround:
Keeping Query Interval value higher than Entry Age Time should solve this problem.
Stopping MLDv1 reports for corresponding group in that vlan should also solve the problem.
FastIron Software Release 08.0.30g Release Notes 106
Defect ID:
DEFECT000528346
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Optics
Symptom:
In FI stack devices, Optical monitoring configuration done on the ports of the member units are lost
after switchover or reload.
Condition:
Optical-monitor configuration is lost after switchover or reload only on the ports of the member units
of FI stack devices.
Defect ID:
DEFECT000528354
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
CLI
Symptom:
Optical monitoring configured on member/standby ports of FastIron stack devices gets lost after
reload.
Condition:
When global optical monitoring configuration is enabled on the FastIron stack devices, the optical
monitoring configuration done on member/standby ports gets lost after reload.
Defect ID:
DEFECT000528509
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Licensing
Symptom:
Expected Output:
-----------------------
ICX7450 unit is enabled with Non-Node locked premium feature sends "non-compliant message"
after 45+ days(46th day).
Current Behavior:
-----------------------
1. But it is observed that the non-compliant message is sent on 47th day instead of 46th day.
2. This delay in sending non-compliant syslog mesage and traps by 1 day and followed by every 24
hr's until a valid license installed.
Condition:
Scenario:
1.ICX7450 unit is enabled with Non-node locked premium feature with out a valid license file.
2. If the feature is active and running after 45+ days of completion, the non-compliant syslog and
trap messages are sent on 46th day followed by every 24 hr message.
Defect ID:
DEFECT000528599
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
Optical monitoring is not displaying any OM values on a 4 unit ICX6430 stack.
When the optical monitoring is enabled on ICX6430 unit in stacking setup using command "optical-
monitor" and then subsequently user tries to see the configured values on the port then it does not
appear to be there.
Condition:
This happens in ICX6430 4 unit stack setup
FastIron Software Release 08.0.30g Release Notes 107
Defect ID:
DEFECT000528600
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
The Optical monitoring configuration is not getting saved in ICX6430 stacking member and standby
units.
Condition:
This happens in ICX6430 stacking member and standby units.
Workaround:
Reapply the configuration after reboot.
Defect ID:
DEFECT000528741
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
SDN
Reported In Release:
FI 08.0.20
Technology Area:
OpenFlow
Symptom:
LLDP packets will not be sent to Controller
Condition:
When Controller adds a generic or a specific flow matching LLDP packet with action send to
controller then LDDP packets won't be sent to Controller
Defect ID:
DEFECT000528969
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 07.4.00
Technology Area:
Traditional Stacking
Symptom:
In ICX 6610 device the 40G port incurs a microflap for a very short duration that can lead to packet
loss
Condition:
Sometimes, a sensitive 40G receiver in presence of noise can cause a microflap.
Defect ID:
DEFECT000529101
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
IPv4/IPv6 Host Management
Symptom:
In FastIron devices running switch image, ping using management IPv6 address fails.
Condition:
Pinging management IPv6 address in a FastIron switch device would fail.
Defect ID:
DEFECT000529138
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.00
Technology Area:
Link Aggregation
Symptom:
In ICX device, ARP table may get deleted and recreated when one of the member port in LAG is
disabled.
Condition:
When a member port in a LAG is disabled, the entire ARP table is cleared in ICX device
Defect ID:
DEFECT000529241
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
On ICX7750 26Q platform when SR4 media is hotswapped back to back sometimes "show media"
CLI does not show media information as its unable to read the media.
Condition:
This happens only when SR4 media is removed and inserted (quick hotswap) back to back.
Workaround:
Reseat the SR4 media by waiting for 3 seconds between removal and insertion operation.
FastIron Software Release 08.0.30g Release Notes 108
Defect ID:
DEFECT000529496
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 07.3.00
Technology Area:
Optics
Symptom:
In very few 100-FX optics, when an interface configured as 100-fx, the interface status in "show
interface" shows as UP when 100-fx SR optics is plugged without a link up.
Condition:
The link is physically down, and the 100-FX optics is plugged-in.
Defect ID:
DEFECT000529895
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SFLOW
Symptom:
sFlow collector cannot decode the sFlow packets from sFlow agent running in a FastIron device.
Condition:
The issue will be observed when sFlow forwarding is configured on a BGP enabled port
Defect ID:
DEFECT000530169
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
ICX6610 does not generate Syslog and SNMP trap messages when the redundant Power Supply Unit
in standby device of ICX6610 stack is removed or powered off.
Condition:
Power-off/removal of redundant Power Supply Unit in standby device of ICX6610 stack.
Defect ID:
DEFECT000530352
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
When an outbound telnet or ssh session is closed from the inbound ssh session, after some time the
switch hosting the inbound SSH may get rebooted
Condition:
If an outbound telnet or ssh session is established from inbound ssh session this issue may occur.
Defect ID:
DEFECT000530407
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.10
Technology Area:
IPv4 Multicast Routing
Symptom:
In FastIron ICX 6610 and FCX 648S, the “ip multicast-routing" command gets displayed twice in the
show running configuration output.
Condition:
In FastIron ICX 6610 and FCX 648S , configuring the “ip multicast-routing” command once will
display the command twice in the running configuration.
Defect ID:
DEFECT000530462
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.01
Technology Area:
BGP4 (IPv4)
Symptom:
BGP route reflector does not discard a route whose Cluster list contains the route reflector's own
cluster ID.
Condition:
The issue occurs whenever a route reflector receives a route with the Cluster list having its own
cluster ID.
FastIron Software Release 08.0.30g Release Notes 109
Defect ID:
DEFECT000530684
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
NTP - Network Time Protocol
Symptom:
With windows server 2000 R2 as NTP server and when executing "show ntp associations detail" in
ICX6450, the device unexpectedly reboots.
Condition:
ICX6450 unexpectedly reboots while executing "show ntp associations detail" when windows server
2000 R2 is used as NTP server.
Defect ID:
DEFECT000530854
Technical Severity:
Critical
Probability:
Low
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Web Management
Symptom:
Standby ICX7750 unit crashed intermittently.
Condition:
Connecting to the ICX7750 switch using HTTPS, an unexpected reload may be seen intermittently.
Defect ID:
DEFECT000530861
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
MAC ACLs
Symptom:
Static MAC entry forwards packets to multiple ports instead of a single port.
Condition:
A static Multi-MAC entry is converted to a regular static MAC entry using the "no static-mac-address
<mac-address> ethe <ports>" CLI command. This command does not remove the static Multi-MAC
entry first, but modifies it to convert it to regular static MAC entry.
Workaround:
Remove the static multi-MAC entry, then configures a regular static MAC entry.
Defect ID:
DEFECT000531131
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
FIPS
Symptom:
Performing switch over on Fast Iron devices thrice, which deletes the trusted certifcate from ICX
switch. Connectivity to encrypted syslog server is lost.
Condition:
Configure encrypted syslog server host on ICX switch.
Perform switch over on ICX switch for three times.
Defect ID:
DEFECT000531299
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
CLI
Symptom:
Upon issuing "show media" command, on FastIron stack devices, the command prompt would not
return to the new line.
Condition:
This issue is observed only on the member units when rconsole is enabled on stack member units of
FI stack devices.
Defect ID:
DEFECT000531538
Technical Severity:
Low
Probability:
High
Product:
IronWare
Technology:
Monitoring/RAS
Reported In Release:
FI 08.0.20
Technology Area:
OAM - Operations, Admin &
Maintenance
Symptom:
show cable-diagnostics tdr command does not work for ICX6430 and ICX6450 platforms.
Condition:
The show command “show cable-diagnostics tdr STACKID/SLOT/PORT” when issued in
ICX6430 and ICX6450 platforms, reports unrecognized command.
FastIron Software Release 08.0.30g Release Notes 110
Defect ID:
DEFECT000531662
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
Telnet
Symptom:
SSH/TELNET to the FastIron device would fail after some days of device boot up.
Condition:
When the FastIron device is managed by NMS tool which does the periodic polling of the device
using SSH/TELNET, the SSH/TELNET connectivity would fail after some days of device boot up.
Defect ID:
DEFECT000531714
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Other
Reported In Release:
FI 08.0.10
Technology Area:
Other
Symptom:
Command Line Interface (CLI) history output shows partial informational commands when question
mark "?" or TAB is pressed for help, during configuration.
Condition:
Whenever the question mark "?" or TAB is pressed for help during configuration, the Command Line
Interface (CLI) history output shows these partial informational commands.
Defect ID:
DEFECT000532029
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 07.4.00
Technology Area:
Traditional Stacking
Symptom:
High CPU is observed on all ICX6450 unites when three or more ICX6450 stack devices are linked to
a hub or a VCX device.
Condition:
When ICX6450 stack devices are connected in a “star” topology through a non-stacking VDX device,
high CPU is seen in all the ICX units.
Workaround:
Apply ACL on the ingress interface of the hub where the ICX stacks are connected so that the
stacking packets leaking into other stacking units through the hub are dropped.
Defect ID:
DEFECT000532318
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Multi-Chassis Trunking
Symptom:
LAG and other Control protocols do not work with Multi Chassis Trunking (MCT).
Condition:
Control plane failures and packet drops with MCT
Fixed in 8.0.30
Defect ID:
DEFECT000532473
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.10
Technology Area:
Link Aggregation
Symptom:
In ICX6610 device, the LAG configuration is not synchronized after stack standby unit is powered off
and powered on.
Condition:
The problem will be observed only when the sFlow is enabled and LAG configurations are applied
in the ICX6610 stacking environment.
FastIron Software Release 08.0.30g Release Notes 111
Defect ID:
DEFECT000532499
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Optics
Symptom:
In ICX6430 device, the optical monitoring for a port does not work when the port is disabled and
enabled.
Condition:
When a port is disable and enabled in ICX6430 the optical monitoring stops working.
Defect ID:
DEFECT000532670
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
MAC ACLs
Symptom:
When customer type in "show mac" command from the console, it is no longer accept it as "show
mac-address" since new command "show mac-authentication" command was introduced on 8.30
release.
Condition:
when using the "show mac" command CLI, it could get resolved as show mac-address command
Workaround:
Added special condition in the parser to recognize "show mac" command as "show mac-address"
Defect ID:
DEFECT000532807
Technical Severity:
Low
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
In ICX64xx device, the information about the optics is not displayed after bouncing the interface.
Condition:
When the 1G/10G interface port is bounced in ICX64xx , the show optics command displays blank
output.
Recovery:
Device reboot is required to get the output again
Defect ID:
DEFECT000533153
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Other
Reported In Release:
FI 08.0.20
Technology Area:
Other
Symptom:
Interface port mayn't transmit or transmit duplicate packets.
Condition:
The following three conditions have to be met:
- specific to ICX 7750 only. Does not impact any other platfrom.
- cut-through forwarding (default mode) is enabled. Does not happen in store and forward mode.
- interface port flow control is enabled.
Workaround:
Use the store and forward mode or disable the flow control.
Defect ID:
DEFECT000533167
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
FIPS
Symptom:
Copy trusted SSL certificate from Linux server to ICX switch. The time and date on the certificates
displays on ICX device doesn't match with the linux server time and date.
Condition:
Copy trusted certificate from Linux machine/server to ICX devices. Display certificate information.
FastIron Software Release 08.0.30g Release Notes 112
Defect ID:
DEFECT000533339
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Component
Symptom:
With performing Disable/enable on MACsec enabled 1G link between MLX-ICX, there is a
fluctuation in link for some time
Condition:
When disable/enable is performed on MACsec enabled 1G link between MLX-ICX, there is a
fluctuation in link for some time
Workaround:
There is no workaround for this issue, it has been fixed in this release
Recovery:
The system recovers automatically after few link flaps. The issue has been fixed in this release
Defect ID:
DEFECT000533352
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.10
Technology Area:
VSRP - Virtual Switch
Redundancy Protocol
Symptom:
FastIron Device will unexpectedbly reloads when the "vsrp-aware vrid 1 tc-vlan-flush" command is
configured and unconfigured.
Condition:
This issue occurs when the command "vsrp-aware vrid 1 tc-vlan-flush" is issued in a vlan and tried to
remove the same configuration.
Defect ID:
DEFECT000533353
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.10
Technology Area:
Traditional Stacking
Symptom:
In a homogeneous or family stack of ICX 6610 and ICX 6450 with IGMP/MLD snooping or VSRP
configuration, some packets generated from CPU can cause an internal loop on the stacking port,
saturating the link bandwidth.
Condition:
This condition is seen when IGMP/MLD snooping or VSRP is configured.
Defect ID:
DEFECT000533481
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
Link Aggregation
Symptom:
TCP and UDP traffic would only hash to one port of the LAG.
Condition:
The issue will be observed when TCP/UDP affic is going out over a LAG.
Defect ID:
DEFECT000533714
Technical Severity:
Low
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
CLI
Symptom:
Not able to configure RADIUS server per port.
Condition:
The option "port-only" is missing for “radius-server host” command.
Defect ID:
DEFECT000533964
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Web Management
Symptom:
In the ICX device, establishing an HTTPs session using Firefox browser with TACACS+
authentication may result in unexpected reload of the device.
Condition:
This issue happens when establishing an HTTPS session using Firefox browser with TACACS+
authentication.
FastIron Software Release 08.0.30g Release Notes 113
Defect ID:
DEFECT000534166
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
DoS - Denial of Service
Symptom:
ICMP and TCP SYN DoS attack prevention does not work as expected on secondary ports of a trunk.
Seen when the port is a 10G or 40G port and not part of stack Active unit.
This issue is seen on ICX7450 and ICX7750 devices.
Condition:
ICMP and TCP SYN DoS Attack on secondary ports of a trunk for 10G or 40G ports
Fixed in 8.0.30
Defect ID:
DEFECT000534182
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.10
Technology Area:
Other IPv6
Symptom:
In FastIron swtich device, the IPv6 Neighbor Discovery packets are not sent out when the device is
configured with IPv6 address for its management port.
Condition:
In FastIron switch device having IPv6 management address configuration, fails to send the IPv6
neighbor discovery packets.
Defect ID:
DEFECT000534475
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
The SNMP walk for ipCidrRoute tables (RFC 2096) doesn't work.
Condition:
RFC 2096 OID's seems to be missing
Defect ID:
DEFECT000535190
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
MAC Authentication
Symptom:
Some RADIUS servers may accept only uppercase user names. To allow this, the Brocade switches
should send the MAC-Addresses in upper case or lower through configurable command.
Condition:
When Brocade switches are connected to RADIUS servers which accept only uppercase user names.
Defect ID:
DEFECT000535213
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
Other IPv4
Symptom:
When a standby unit is powered off or removed from the stack, ICX stack prints "*** Warning! u4
standby sends packet" on new standby unit console.
Condition:
A three or more units stack with sFlow configured and with IPv6 traffic.
FastIron Software Release 08.0.30g Release Notes 114
Defect ID:
DEFECT000535322
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
Other IPv6
Symptom:
Periodically lost IPv6 traffic every 5-10 minutes
Condition:
Sending IPv6 traffic
Workaround:
Disable IPv6 cache aging by the following command:
"ipv6 cache-lifetime 0"
Defect ID:
DEFECT000535520
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
With MACSec feature, data traffic is not getting blocked when MKA protocol is enabled on the port
hence line protocol remains down.
Condition:
When MKA protocol is enabled on a port without configuring the key.
Workaround:
Configure the keys before enabling the MKA protocol on the ICX link
Defect ID:
DEFECT000535591
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
802.1x Port Security
Symptom:
ICX devices does not support standard ACL. So, if Radius server returns standard ACL, then ICX
devices fails the client. But the syslog wrongly says Radius server has rejected the client.
Condition:
Actually the issue was wrong configuration at the Radius side.
Defect ID:
DEFECT000535659
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Multi-Chassis Trunking
Symptom:
With MCT configuration present in the system and static mac configured with priority option, the
priority assigned is not taken effect in the MCT peer.
Condition:
MAC priority does on take effect in MCT peer. This issue is fixed in 8.0.30.
Defect ID:
DEFECT000535781
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
After enable and disable global route-only, L2 traffic dropped.
Condition:
Global route-only is enabled and disabled.
Defect ID:
DEFECT000535997
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
snmpwalk times out while walking dot1dBridge MIBS table where user is authenticated with version
V3.
Condition:
snmp V3 user with AES/DES encryption and SHA/MD5 authentication should be enabled. Attempt
to walk the dot1dBridge MIBS table.
FastIron Software Release 08.0.30g Release Notes 115
Defect ID:
DEFECT000536169
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
PIM-Snooping running switch will not forward the packets on (*,G) forwarding tree. This will
prevent the SPT convergence and will disrupt Multicast traffic.
Condition:
Multicast traffic not does not take shortest path tree. This is fixed in 8.0.30 and exists in 8.0.20 only.
Defect ID:
DEFECT000536197
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
Protocols stop working after a LAG with egress ACL is undeployed.
Condition:
Undeploying LAG with Egress ACL configured
Fixed in 8.0.30.
Defect ID:
DEFECT000536200
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
Applying Egress ACL a second time on a LAG after it is applied and then removed fails.
Condition:
Reapplying Egress ACL on a LAG
Fixed in 8.30.
Defect ID:
DEFECT000536464
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
MAC Authentication
Symptom:
Memory exhausts over long period of up time with Flexauth feature. More likely seen when Radius
server is unreachable.
Condition:
Occurs when Radius server is unreachable for authentication
Fixed in 8.0.30
Defect ID:
DEFECT000536531
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
SDN
Reported In Release:
FI 08.0.30
Technology Area:
OpenFlow 1.0
Symptom:
Openflow 1.0 accepts out of range queue number from a controller when a en-queue action is
received from it. Valid queue range is 0-7, anything outside should rejected by the switch..
Condition:
When switch receives en-queue action with queue > 7 from controller.
Defect ID:
DEFECT000536608
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
MRP - Metro Ring Protocol
Symptom:
When a vlan with MRP configured is completely removed, the port goes to default vlan (ie no vlan
command) and now when the same vlan is created back, ports added and MRP is enabled, MRP does
not converge.
Condition:
MRP convergence failures during removal of port from a VLAN. This issue is fixed in 8.0.30
FastIron Software Release 08.0.30g Release Notes 116
Defect ID:
DEFECT000536748
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
After failover, traffic on MACsec enabled ports will no longer be MACsec protected due to missing
configuration. Traffic will be blocked if the link partner has MACsec configured.
Condition:
Unexpected reload of active unit
Workaround:
Reconfigure the MACSec configuration
Defect ID:
DEFECT000536989
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.10
Technology Area:
FIPS
Symptom:
SSL poodle attack vulnerability
Condition:
When HTTPS is connected using SSL 3.0, there is chance for poodle attack.
Defect ID:
DEFECT000537299
Technical Severity:
Medium
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
“show tech” command output does not have sysmon counter information for ICX6610 devices.
Condition:
When show tech command is issued, in FastIron devices, the sysmon counter information would not
be displayed.
Defect ID:
DEFECT000537353
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
When the skip page mode was enabled and when a huge show command output is displayed on the
SSH terminal, the SSH session is terminated.
Condition:
Enable the skip page mode. Run the show CLI commands such as "show tech" or “show interface" to
generate a huge output.
Defect ID:
DEFECT000537452
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
In FastIron ICX7750, ICX7250 and ICX7450 devices CPU may hog when support save command is
executed.
Condition:
This issue happens in ICX devices when supportsave command is executed.
Defect ID:
DEFECT000537849
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
Packet loss for Multicast Data Traffic is seen when the stack topology changes from Linear to Ring.
Condition:
When the stack topology changes from Linear to Ring, The new stack ports were not added to the
IPMC replication resources. This would affect functional areas like IGMP snooping, V4/V6 multicast
Routing and also Openflow.
FastIron Software Release 08.0.30g Release Notes 117
Defect ID:
DEFECT000537998
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.4.00
Technology Area:
VSRP - Virtual Switch
Redundancy Protocol
Symptom:
The "restart-vsrp-port 1" command does not persist across reload.
Condition:
When the "restart-vsrp-port 1" command is issued with the default value timer value which is "1", the
command is not saved in the configuration.
Workaround:
Configuring VSRP fast restart feature with non-default timer value will not cause this issue.
Defect ID:
DEFECT000538367
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
OSPF (IPv4)
Symptom:
Traffic drop is observed in a system with routes learned over IPv6 tunnel after fail over is performed.
An error message is seen only if a neighbor on the tunnel.
Condition:
Traffic drops over IPv6 tunnel after failover This is fixed in 8.0.30 and is present in 8.0.20.
Defect ID:
DEFECT000538720
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
OSPF (IPv4)
Symptom:
OSPF adjacency is not formed on a VE interface on a default VLAN after switchover
Condition:
VE interface created over default VLAN and OSPF is running over the VE interface followed by
switch over.
Defect ID:
DEFECT000538792
Technical Severity:
Low
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
CLI
Symptom:
Spelling error found in CLI command 'show arp resource' where resoruce should have been resource.
Condition:
Spelling error found in CLI command 'show arp resource' where resoruce should have been resource.
Defect ID:
DEFECT000538812
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.10
Technology Area:
ACLs (IPv4)
Symptom:
ICX6610 device drops packets from directly connected hosts in the virtual Ethernet interface that is
configured with outbound ACL.
Condition:
ICX6610 device having a virtual Ethernet interface with outbound ACL configured, would drop all
the routing packets received from the directly connected hosts.
Defect ID:
DEFECT000538827
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
Port Loop Detection
Symptom:
In a FastIron device, when "loop-detection shutdown-disable" command is configured on interfaces,
and the device detects a Layer 2 loop, the “show loop-detection no-shutdown-status" command output
displays the ports are in loop even after the port is shut down.
Condition:
When "loop-detection shutdown-disable" command is configured on interfaces, and the device detects
a Layer 2 loop, the "show loop-detection no-shutdown-status" command output shows that the ports
are in loop.
FastIron Software Release 08.0.30g Release Notes 118
Defect ID:
DEFECT000538997
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Optics
Symptom:
On the ICX6610 unit when the speed is changed on a disabled 10G port, remote end comes up.
Condition:
This happens on the ICX6610 10G port. When the port is in Disabled state and the user changes its
speed then remote link partner comes up.
Workaround:
No, there is no workaround for this issue, this has been fixed in this release
Recovery:
No.
The fix has been provided in this release
Defect ID:
DEFECT000539003
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
VLAN
Symptom:
The "show mac-address" CLI output does not display any MAC addresses learned.
Condition:
Problem is seen on a 2-unit stack after hitless failover.
Recovery:
Reload the stack.
Defect ID:
DEFECT000539027
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
Port Loop Detection
Symptom:
In a FastIron device, Syslog gets generated when loop is detected only for the first time while the
"loop-detection shutdown-disable" command is configured on the interfaces.
Condition:
When "loop-detection shutdown-disable" command is configured on interfaces,the syslog gets
generated when loop is detected but only for the first time.
Defect ID:
DEFECT000539060
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
NTP - Network Time Protocol
Symptom:
System clock is configured. Reloading the device after specific time is not allowed. Displays error
message"clock is not set, request aborted!".
Condition:
System clock is configured. Reloading the device after specific time is not allowed.
Defect ID:
DEFECT000539302
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
Receive ACLs
Symptom:
In a FastIron stack device, the output of the "show access-list account" command may be incorrect.
Condition:
This issue happens only on an ICX stack device when extended access-list with more than 10 rules
are applied on a virtual Ethernet interface that has members on active and member units.
FastIron Software Release 08.0.30g Release Notes 119
Defect ID:
DEFECT000539414
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv6
Symptom:
After removing a route-only IP port, the broadcast packets(for example, arp request) cannot be sent
out from the default vlan.
Condition:
Configure one physical IP port as route-only port, then save configuration and reload. After reload,
remove all configuration of this route-only port, then issue will happen.
Defect ID:
DEFECT000539549
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
VLAN
Symptom:
In a system with a private VLAN configuration, reload and stack switchover results in complete
traffic drop when the promiscuous port is present in the standby unit.
Condition:
The issue is seen in a system with private VLAN configuration upon reload and switchover.
Defect ID:
DEFECT000539613
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
VLAN
Symptom:
Deleting one of the secondary vlan removes all dynamically learnt mac addresses on promiscuous
port & secondary vlan ports.
Condition:
Deleting secondary private vlans clears some mac addresses. This issue is fixed in 8.0.30
Defect ID:
DEFECT000539880
Technical Severity:
Critical
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
CLI
Symptom:
Configuration is not getting saved when doing a "write memory" and then power cycling the device.
Configuration will be saved if a reload is issued or if the power cycle is performed after a minute or
so.
Condition:
Configuration is not getting saved when doing a "wr mem" and then power cycling the device.
Configuration will be saved if a reload is issued or if the power cycle is performed after a minute or
so.
Workaround:
Configuration will be saved if a reload is issued instead or if the power cycle is performed after a
minute or so
Recovery:
If the modified config is lost after power cycle then there is no way to recover the modification
Defect ID:
DEFECT000539925
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
VSRP - Virtual Switch
Redundancy Protocol
Symptom:
VSRP commands does not appear when one enters into vlan group mode and come back.
Condition:
VSRP commands does not appear when vlan group is exited. This is fixed in 8.0.30
FastIron Software Release 08.0.30g Release Notes 120
Defect ID:
DEFECT000540064
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
SDN
Reported In Release:
FI 08.0.30
Technology Area:
OpenFlow 1.3
Symptom:
Flow with Match ARP Ether Type with action Send to controller.
Condition:
Flow with match ARP ether type with action send to controller is not getting forwarded to controller
and getting dropped in the switch.
Defect ID:
DEFECT000540212
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
When the multicast snooping group hash information for a VLAN is displayed using the command
"show ip multicast vlan <vlan-id> hash" and the display pagination is aborted, it causes unexpected
reload of the system.
Condition:
Issue will be seen, if the customer uses the command "show ip multicast vlan <vlan-id> hash"
command and aborts the display pagination. Issue is fixed in FI 8.0.30 release.
Workaround:
Do not use the hash option for this command. Instead use the "show ip multicast vlan <vlan-id>"
command to display the multicast snooping group information for a VLAN.
Defect ID:
DEFECT000540242
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.10
Technology Area:
Multi-Chassis Trunking
Symptom:
In the ICX6650 device, the SSTP or MSTP topology may not converge in MCT setup as expected
when CCEP and CEP ports are configured as untagged member to different VLANs.
Condition:
The issue will be seen only when the CCEP and CEP ports of the MCT setup are configured as
untagged member to different VLANs and the “bpdu-flood-enable” command is configured on cluster
devices.
Defect ID:
DEFECT000540576
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Licensing
Symptom:
The ICX7450 switch reloads continuously because of the software license issue.
Condition:
Brocade licensing portal has generated invalid Non-Node Locked License and the user loaded the
License on to the ICX device.
Defect ID:
DEFECT000540707
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
CLI
Symptom:
When the ICX6650 and MLX devices are connected over 10G links and when configured to operate
on 1G mode then then link does not come up.
Condition:
The 10G port of ICX6650 fails to come up when configured to operate in 1G mode.
FastIron Software Release 08.0.30g Release Notes 121
Defect ID:
DEFECT000540749
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.20
Technology Area:
Other IPv6
Symptom:
The IPv6 traffic coming from authenticated client was dropped by the ICX devices with flexible
authenticated ports.
Condition:
Observed only with flexible authenticated ports.
Defect ID:
DEFECT000540774
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Component
Symptom:
IPv6 Ping over Management VLAN succeeds only after few minutes
Condition:
IPv6 ping on management port after a switchover
Issue is fixed.
Defect ID:
DEFECT000541072
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
SSH - Secure Shell
Symptom:
In JITC mode, SSH connection through an ipv6 address fails.
Condition:
Enable JITC mode. Attempt to establish a SSH connection to ICX switch using Ipv6 address
Defect ID:
DEFECT000541173
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.10
Technology Area:
IPv4 Multicast Routing
Symptom:
The multicast PIM table entries of ICX devices are not updated during link failures resulting in
connectivity loss.
Condition:
When a multicast source with NIC teaming enabled and dual home to
two Brocade PIM-dense/ sparse routers, and if one of the links fail, the
Brocade routers fail to upate their mcache table to point to the current active link resulting in
connectivity loss.
Defect ID:
DEFECT000541206
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
SFLOW
Symptom:
In ICX7750 device, the configured sflow sample-rate on the LAG out of the breakout ports gets lost
and takes the default sample rate after reload
when the sflow forwarding is first enabled on secondary ports and on the primary port later.
Condition:
This issue happens only when the sflow forwarding is enabled on the secondary ports of the LAG
created out of break out ports first and then on the primary port later.
Defect ID:
DEFECT000541262
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.20
Technology Area:
IPv4 Multicast Routing
Symptom:
FastIron ICX device unexpectedly reloads upon configuring more than 512 PIM neighbors.
Condition:
When configuring more than 512 PIM neighbors the FastIron ICX device reloads unexpectedly.
FastIron Software Release 08.0.30g Release Notes 122
Defect ID:
DEFECT000541263
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.00
Technology Area:
NTP - Network Time Protocol
Symptom:
NTP vulnerability VU#852879 ( CVE-2014-9293, 9294, 9295 and 9296).
Condition:
NTP vulnerability VU#852879.
Defect ID:
DEFECT000541278
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
In the ICX6610 device, the port link does not come up when a 100M device is connected using a 1G
copper SFP.
Condition:
When 100M device is connected to ICX6610 device using a 1G copper SFP, the link would not come
up.
Workaround:
Configuring "speed 100-full" would resolve.
Defect ID:
DEFECT000541350
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv6
Symptom:
Switch does not send "ICMPv6 Parameter Problem Error Message" for unrecognized IPv6 Next
Header.
Condition:
When IPv6 packet with unrecognized Next Header is received.
Defect ID:
DEFECT000541452
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
CLI
Symptom:
The 1G Link of ICX7750-48F when configured as "speed-duplex 1000-full" would not come up
when connected to a non Brocade switch.
Condition:
When the link partner does not support auto-negotiation the 1G optic link of ICX7750-48F does not
come up when "speed-duplex 1000-full" is configured
Defect ID:
DEFECT000541533
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Traffic leak seen for clients though IP Address for the Client is not validated using ARP Inspection
Condition:
When Source-Guard is enabled with MAC Authentication.
Fixed in 8.0.30
Defect ID:
DEFECT000541567
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
On an interface replacing a large egress ACL with another egress ACL may fail.
Condition:
Changing a large ACL applied on a LAG
Fixed in 8.0.30.
FastIron Software Release 08.0.30g Release Notes 123
Defect ID:
DEFECT000541977
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
The 10G ports of FastIron SX/ICX devices reports CRC errors after some days of device boot up.
Condition:
After some of days of device boot up, the FastIron SX/ICX devices reports CRC errors.
Defect ID:
DEFECT000541999
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
Stack port link change of stack trunk could impact stack communication.
Condition:
When a stack link of a stack trunk is removed and added, stack communication is impacted.
Fixed in 8.0.30
Defect ID:
DEFECT000542320
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Hitless Switchover, Failover,
Hotswap, OS U/G
Symptom:
L3 multicast failure on failover of active unit
Condition:
Failover of active unit
Issue is Fixed in 8.0.30
Defect ID:
DEFECT000542450
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
Ping to IPv6 hosts on a VLAN through a port previously configured for Flexauth fails
Condition:
After Flexauth is removed from a port and added to another vlan as untag member this issue is seen.
Fixed in 8.0.30
Defect ID:
DEFECT000542668
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
VLAN
Symptom:
After removal of the association of a secondary VLAN with the primary VLAN, the affic from the
secondary VLAN leaks to the primary VLAN.
Condition:
Traffic leaks into secondary VLAN from the primary VLAN when configuration is removed.
Defect ID:
DEFECT000543317
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
DHCP (IPv4)
Symptom:
During DHCP client auto configuration update process, after the image is downloaded, system starts
printing error messages continuously.
Condition:
The issue is observed on downloading the image through TFTP, when the DHCP client and auto
configuration are enabled.
FastIron Software Release 08.0.30g Release Notes 124
Defect ID:
DEFECT000543585
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Routing
Symptom:
PIM-SM RP(Rendezvous Point) router may stop originate SAs for the multicast flows whose sources
are in local domain.
Condition:
This may happen only if the RP was not in the SPT (shortest path tree) path. The issue is fixed in FI
8.0.30 release.
Defect ID:
DEFECT000543773
Technical Severity:
Medium
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
Config changes are not saved when flash is out of space
Condition:
Due to large core files, flash runs out of space. Issue is resolved. Config changes will be saved.
However there could be scenarios where a large core file corresponding to the most recent crash may
not be saved when flash is out of space.
Defect ID:
DEFECT000543815
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
CLI
Symptom:
The command mdi-mdix is throwing error and stack trace on ICX 7450 1G copper port
Condition:
When the command "mdi-mdix" was issues from CLI for the ICX7450 1G copper port then the error
and stack trace messages were seen on console
Workaround:
There is no workaround for this issue, the fix has been provided in this release
Recovery:
There is no recovery required here. The command "mdi-mdix" does not work. The fix has been
provided in this release
Defect ID:
DEFECT000543848
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
DAI - Dynamic ARP Inspection
Symptom:
Unexpected Reload when ARP inspection or DHCP snooping is applied on a VLAN which does not
have a VE configured.
Condition:
Applying ARP Inspection or DHCP Snooping on a VLAN which does not have a VE configured.
Fixed in 8.30.
Defect ID:
DEFECT000544051
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SFLOW
Symptom:
In a FastIron stack switch, when IPv6 sFlow collector is configured, the sFlow packets are seen with
zero samples at the sFlow collector from standby ports.
Condition:
This issue happens only on IPv6 sFlow collector configured on a FastIron stack switch where zero
samples are received from the standby ports.
Workaround:
Configuring the “no sflow enable" command followed by the "sflow enable" command solves the
issue.
FastIron Software Release 08.0.30g Release Notes 125
Defect ID:
DEFECT000544059
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
CLI
Symptom:
Port with Copper GBIC goes down when speed is set to 1000-full-master or 1000-full-slave
Condition:
Setting speed change on port with Copper GBIC
Issue is Fixed in 8.0.30
Defect ID:
DEFECT000544408
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.10
Technology Area:
Receive ACLs
Symptom:
When MCT client connecting to the ICX7750-MCT-cluster, MAC movement is observed on the
MCT client.
Condition:
In an MCT setup created with the ICX7750 cluster device, the multicast traffic would get leaked into
the CCEP ports resulting in MAC movement in the MCT client device
Defect ID:
DEFECT000544446
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
RA Guard (IPv6)
Symptom:
In the ICX6610 device, when IPv6 RA guard is configured "Error:Insufficient hardware resources to
apply the RAGuard" is reported.
Condition:
When IPv6 RA guard policy is configured on VLANs tagged with many ports then error will be
reported.
Defect ID:
DEFECT000544504
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Security Vulnerability
Symptom:
ACL stops working and unexpected reload may be observed.
Condition:
In case of large ACL applied on VE along with Dos Attack configuration, adding or removing
logging causes this issue.
Fixed in 8.0.30
Defect ID:
DEFECT000544655
Technical Severity:
High
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.01
Technology Area:
Component
Symptom:
A PoE port that is Admin Enabled for inline power does not supply power to a PD event though PD is
valid and there is enough PoE power capacity available in the system.
Condition:
The port is Admin Enabled, there is PD connected to the port and detected, and the PD gets power
from the port with the Oper Enabled state. Beyond that there is no specific known condition that
triggers the problem symptoms.
Recovery:
Disable the inline power on the port and re-enable it.
FastIron Software Release 08.0.30g Release Notes 126
Defect ID:
DEFECT000544725
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
On switchover, the clients already authenticated either through Dot1x or Mac-Auth earlier fails to re-
autheticate
Condition:
Switchover with already authenticated clients
Fixed in 8.0.30
Defect ID:
DEFECT000544949
Technical Severity:
Low
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Web Management
Symptom:
Through the following web management page "Config->Port->Ethernet->Modify: " user cannot edit
the interface port name with spaces. Displays an error message.
Condition:
Open the web page "Config->Port->Ethernet", select the interface port, attempt to modify the
interface port name.
Defect ID:
DEFECT000544977
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
The link status shows as "Err_LFS" on one end of link and "Up" on the other end
Condition:
If LFS feature is enabled on a port and user inserts a 10G twinax cable,this issue may be observed.
Defect ID:
DEFECT000545122
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
In ICX6610 stack device, while executing a support save command over an SSH terminal, CPU goes
high and dynamic LAG links go down.
Condition:
When an eight unit ICX6610 stack device has a dynamic LAG, issuing support save over a SSH
session, makes the links of the dynamic LAG go down even with no traffic.
Defect ID:
DEFECT000545212
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
DAI - Dynamic ARP Inspection
Symptom:
DHCP snooping stops working after deletion and reconfiguration of the same vlan.
Condition:
Deleting the vlan on which DHCP snooping is configured and then creating it back causes this issue.
Workaround:
This issue is fixed 8.0.30 release. If this issue is encountered in 8.0.20 or older releases,please
remove DHCP snooping configuration from vlan before deleting and doing other operations on
that vlan.
FastIron Software Release 08.0.30g Release Notes 127
Defect ID:
DEFECT000545366
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 07.3.00
Technology Area:
Other IPv4
Symptom:
In FastIron FCX stack device, IP reachability issue is observed on ports connected to the active unit
when it is elected through stack priority change.
Condition:
When stack MAC address is configured in the FastIron stack device, and if the active unit gets elected
through stack priority change, IP reachability issues are observed on the active units' ports.
Defect ID:
DEFECT000545457
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
PoE/PoE+
Symptom:
POH ports do not reliably provide POE+ power to AP devices
Condition:
PoE devices connected to POH ports (Ports 1 to 8) on ICX 7450.
Recovery:
Issue is fixed with a firmware upgrade on the PoE controller on ICX 7450.
Defect ID:
DEFECT000545520
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
OSPFv3 (IPv6)
Symptom:
OSPFv3 peer on IPv6 over IPv4 tunnel will be down after switchover or failover.
Condition:
OSPF V3 tunnel down after swtichover. This is fixed in 8.0.30.This issue exist in the previous
release, if we come across this defect we can publish this defect as fixed in 8.0.30
Workaround:
After switchover/failover un-configure the tunnel configuration and re-configure again.
Defect ID:
DEFECT000545548
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
One of the cluster device keep rebooting when snooping is enabled on only one of cluster device and
igmp/mld querier or pim is enabled on the CCEP client.
Condition:
MCT clusters keeps rebooting when snooping is enabled on only one cluster. This is fixed in 8.0.30.
If there is customer defect in previous version we can publish this defect.
Workaround:
Ensure multicast snooping is enabled on both the cluster device before enabling igmp/mld querier
or pim is enabled on the CCEP client.
Defect ID:
DEFECT000546052
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv6 Multicast Routing
Symptom:
IPv6 multicast data traffic is not getting forwarded to the receiver and this data traffic is hitting the
CPU causing high CPU. In this case FCX is not able receive all the PIM register packet sent to it
resulting in failure to create S,G flow.
Condition:
High CPU due to IPv6 traffic hitting CPU. This issue is already fixed in 8.0.30.
This issue is existing previous release from 8.0.0.
FastIron Software Release 08.0.30g Release Notes 128
Defect ID:
DEFECT000546080
Technical Severity:
Critical
Probability:
Medium
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv4 Multicast Switching
Symptom:
Unexpected system reset.
Condition:
Issue seen only when L2 table is full. Will be seen only in MLD snooping scenario.
Workaround:
1) MAC entries + MLD snooping entries should not exhaust L2 table.
or
2) Do not enable mld snooping.
Defect ID:
DEFECT000546148
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Component
Symptom:
The command "show int e 1/2/X" is not working and is throwing an error message on ICX7450-48 for
the ICX7400-4X1GF module ports
Condition:
When ICX7400-4x1GF module port is connected to ICX7450 and the "show int e 1/2/x" command is
issued, then the error message appears on console and this command does not work.
Defect ID:
DEFECT000546345
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
IPv6 ACL application fails on a VE where an Ingress ACL with accounting is enabled earlier for
multiple VEs
Condition:
Configuring IPv6 ACL on VE when Ingress ACL with Accounting is enabled already
Fixed in 8.0.30
Defect ID:
DEFECT000546533
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
User was unable to successfully download the SSHv2 public key on to the ICX switch using TFTP
from an established SSH session.
Condition:
Establish SSH session. Execute the “ip SSH public key” command to download the SSHv2 public key
on to the ICX switch.
Defect ID:
DEFECT000546694
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
Unable to remove Egress ACL after re-deploying LAG
Condition:
This issue is seen on LAG port when IPV4 Ingress ACL and Egress ACL along with IPV6 Ingress
ACL and Egress ACL are configured.
Fixed in FI 8.0.30
FastIron Software Release 08.0.30g Release Notes 129
Defect ID:
DEFECT000546960
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
If a CLI user configures the command "ip ssh source-interface" with valid arguments as per FI8.0.10
and 8.0.20 L3 guide, the command is accepted by the CLI. However, it does not appear in the
running configuration. It is also missing from context sensitive help.
Condition:
"ip ssh source interface" commands are not supported on FastIron platforms now.
Defect ID:
DEFECT000547088
Technical Severity:
Critical
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.30
Technology Area:
Component
Symptom:
Unexpected reload when rebooting from either partition under rare circumstances after displaying
version information
Condition:
Rebooting after displaying version information from either partition.
Rarely observed.
Fixed in 8.0.30
Defect ID:
DEFECT000547193
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
IP Multicast
Reported In Release:
FI 08.0.30
Technology Area:
IPv6 Multicast Switching
Symptom:
This issue is seen in system having MCT configuration. Is seen when one of the MCT cluster is
coming up and other MCT cluster has PIM-SMSnooping members learnt. When MCT CCP comes up
the PIM-SM snooping trigger baseline sync to newly up cluster the OIF are not getting added to
multicast cache on baseline sync.
Condition:
Multicast traffic loss in a MCT setup when one of the cluster is booting up. This is fixed 8.0.30
Workaround:
clear ip/ipv6 multicast mcache
Defect ID:
DEFECT000547267
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
Receive ACLs
Symptom:
IPv6 ACL stops working to deny traffic after switchover.
Condition:
When IPv4 ACL and IPv6 ACL are configured on a virtual interface and switch-over is performed,
this issue was observed.
Defect ID:
DEFECT000547631
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
VRRP & VRRP-E (IPv4)
Symptom:
With VRRP configuration present in the system, the parser malfunctions resulting in system reset.
Condition:
This issue is fixed in 8.0.30 release. Could exist in previous release.
FastIron Software Release 08.0.30g Release Notes 130
Defect ID:
DEFECT000547670
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
MAC Authentication
Symptom:
Switch or router does not get authenticated through IPv6 RADIUS server when management VRF is
configured.
Condition:
If management VRF is configured, switch or router does not get authenticated through IPv6 RADIUS
server.
Defect ID:
DEFECT000547884
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.10
Technology Area:
802.1x Port Security
Symptom:
Dot1x authentication was not happening with FastIron for 802.1x supplicant using EAPOLv2 packets.
Condition:
With the 802.1x supplicant that has the ability to request for authentication using EAPOLv2 packet
typel the FastIron device is unable to honour the EAPOLv2 packet type, and the transaction could not
be completed.
Defect ID:
DEFECT000547896
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
PBR does not work on member unit ports of 3 or more unit stack on ICX 7750 and ICX 7450.
Condition:
When configuring Global PBR and IPV6 ACL on interface of a stack with 3 or more units, this issue
was observed.
Fixed in FI 8.0.30
Defect ID:
DEFECT000547900
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv4
Symptom:
PBR does not work on member unit ports of 3 or more unit stack on ICX 7750 and ICX 7450.
Condition:
When configuring Global PBR and IPV6 ACL on interface of a stack with 3 or more units, this issue
was observed.
Fixed in FI 8.0.30
Defect ID:
DEFECT000548000
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
UDLD - Uni-Directional Link
Detection
Symptom:
UDLD link stays down
Condition:
Observed when a stack unit on ICX 7450 has one stack port and the other stack port is made a data
port.
Issue is Fixed in 8.0.30
FastIron Software Release 08.0.30g Release Notes 131
Defect ID:
DEFECT000548129
Technical Severity:
High
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
CLI
Symptom:
The ICX switches unexpectedly reloads on running the SSHv2 login and logout script and performing
file upload download using the SCP command.
Condition:
Enable the SSHv2 on ICX switch. Run the SSHv2 login and logout script from the Linux server
continuously for few days. Perform boot image upload and download from the ICX switch using the
SCP command.
Defect ID:
DEFECT000548397
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Static Routing (IPv6)
Symptom:
Scaling beyond default IPV6 route will not be possible even thought the maximum IPV6 routes is far
more than default values. This is applicaple of ICX6450, ICX6450-C12 and ICX7250
Condition:
Scaling beyond default IPv6 route issues errors. This is fixed in 8.0.30.
Defect ID:
DEFECT000548618
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.20
Technology Area:
DAI - Dynamic ARP Inspection
Symptom:
When ARP inspection or DHCP snooping is applied on a VLAN which does not have a VE
configured or a port is added in this vlan, unexpected reload may happen
Condition:
Reload seen when ARP inspection or DHCP snooping configuration with out a VE configuration.
This is fixed in 08.0.30.
Defect ID:
DEFECT000548686
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
Other IPv6
Symptom:
IPv6 static route missing in the new active unit after a failover and this results in unicast traffic not
being forwarded for this route.
Condition:
In a active-standby-member stack, powering down the active results IPv6 static route missing in new
active.
Recovery:
Disabling/Enabling the interface over which the static route needs to be learned results in the route
being added to the table.
Defect ID:
DEFECT000548748
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.20
Technology Area:
MAC ACLs
Symptom:
In ICX64xx, the MAC re-authentication fails once the session gets timed out. This is more evident
when max-session value is 1.
Condition:
The issue is observed when the mac-authentication is successful on a port that is configured with a
max-session value of 1 and when the RADIUS session gets timed out
Workaround:
Set a value of more than 1 for max-session.
FastIron Software Release 08.0.30g Release Notes 132
Defect ID:
DEFECT000548935
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 08.0.30
Technology Area:
802.1x Port Security
Symptom:
VOIP clients authenticated before switch-over will fail to autheticate
Condition:
Switchover with authenticated VOIP Clients.
Fixed in 8.0.30
Defect ID:
DEFECT000548942
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
Telnet
Symptom:
Configure "no telnet server" and save the configuration. Reload the ICX switch, "no telnet server"
command disappears each time.
Condition:
Configure “ip telnet source-interface management 1” and "no telnet server".
Save the configuration. Reload the ICX switch. Execute "show run".
Defect ID:
DEFECT000548949
Technical Severity:
Critical
Probability:
Low
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
The number of default IPv6 entries may wrongly show up as 208 where as the actual value should be
212 IPv6 entries when a startup config file is present at bootup. This is applicable to ICX6450 and
ICX6450-C12
Condition:
ICX645X with incorrect IPv6 entries causes box reload. This is fixed in 8.0.30
Defect ID:
DEFECT000549668
Technical Severity:
Critical
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.30
Technology Area:
Traditional Stacking
Symptom:
While forming a fresh stack using a switch image, unit goes for unexpected reload.
Condition:
Stack formation for Switch with Secure setup Utility
Fixed in 8.0.30
Defect ID:
DEFECT000549672
Technical Severity:
Medium
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SFLOW
Symptom:
In FI stack devices, the "sFlow forwarding" configuration gets lost after failover.
Condition:
When "sFlow forwarding" is enabled on the interfaces of both active and standby units, after
switchover and powering off the new active unit, the sFlow configuration gets removed from the new
standby unit.
FastIron Software Release 08.0.30g Release Notes 133
Defect ID:
DEFECT000549675
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
Management VRF
Symptom:
In FastIron devices, after execution of support save command, few of the show commands reports
error.
Condition:
In FastIron devices, when support save command is executed, few of the show commands reports
error.
Defect ID:
DEFECT000549751
Technical Severity:
High
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.30
Technology Area:
GRE
Symptom:
In FastIron stack devices, ARP entries remains in pending state for directly connected interface over
8-port LAG.
Condition:
This issue happens only when the stack mac is configured in the FastIron stack devices
FastIron Software Release 08.0.30g Release Notes 134
Closed defects without code changes in Release 08.0.30
This section lists defects closed without code changes in the 08.0.30 release.
Reported release indicates the product and release where the defect was first identified. If the problem
also appeared in other Brocade IP products, the issue was addressed using the same defect ID.
Defect ID:
DEFECT000486444
Technical Severity:
Medium
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.01
Technology Area:
Multi-Chassis Trunking
Symptom:
When a ping from external network is issued to a Multi Chassis Trunk (MCT ) cluster client,
continuous syslog messages indicating ARP station movement are printed on the console. This
happens only after executing “clear mac” and then trying to ping.
Condition:
Ping from external network to MCT Client results in continuous syslog messages on VRRP-E Master.
Workaround:
Don’t do the clear mac before ping. The messages stop printing right after ping stops and doesn't
affect any functionality impact.
Defect ID:
DEFECT000488923
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
Wrong interface is being shown as management interface in snIfIndexLookupTable.
Condition:
Wrong interface is being shown as management interface in snIfIndexLookupTable.
Defect ID:
DEFECT000496303
Technical Severity:
High
Reason Code:
Not Reproducible
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.11
Technology Area:
Secure Setup, Autoconfig, Manifest
files, Autocopy
Symptom:
When the active unit with highest priority fails and reboot as standby, the LAG got undeployed with
error message.
Condition:
LAG could not be deployed on the ports after the active unit with highest priority fails and reboots as
standby unit.
Defect ID:
DEFECT000498541
Technical Severity:
Medium
Reason Code:
Will Not Fix
Probability:
Low
Product:
IronWare
Technology:
Management
Reported In Release:
FI 07.4.00
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
Response to SNMP get or walk queries will show the community "public" even though other read-
only communities are configured in the running config and "public" is not.
Condition:
Pasting an encrypted SNMP community can fail to remove "public" as the default read-only
community
Defect ID:
DEFECT000521087
Technical Severity:
Medium
Reason Code:
Will Not Fix
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
When attempting SSH connection into the ICX6650 device, it takes long time to get the login prompt.
Condition:
Connecting to ICX6650 using SSH takes longer time.
FastIron Software Release 08.0.30g Release Notes 135
Defect ID:
DEFECT000522416
Technical Severity:
Medium
Reason Code:
Will Not Fix
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
Standalone unit of ICX7750 throws error "M:9 L:0 - icx7750_media_read, port 1/2/2, error in reading
sfpp addr=50 offset=80 status=-1" , on booting up
Condition:
On bootup the standalone ICX7750 unit throws following error for port 1/2/2 sometime:
------------------------------------------------------------------
M:9 L:0 - icx7750_media_read, port 1/2/2, error in reading sfpp addr=50 offset=80 status=-1
------------------------------------------------------------------
Workaround:
Should not occur under normal maintenance operation; represents an unlikely user scenario
Defect ID:
DEFECT000522459
Technical Severity:
High
Reason Code:
Design Limitation
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
When try to configure speed 10G for port 3/3/2 which is not part of any lag, then logical link for port
3/3/1 is flapping.
Condition:
Changing the speed of a 10G port 3/3/2 in ICX6610 causes port 3/3/1 to flap
Recovery:
It recovers automatically
Defect ID:
DEFECT000524837
Technical Severity:
Medium
Reason Code:
Design Limitation
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
Telnet
Symptom:
Customer running the port scan utility nmap tool to scan the ICX switch. After few days, telnet
stopped spawning new sessions
Condition:
Run the nmap tool to scan the ICX switch for long hours. After few days, attempt to telnet to the ICX
switch
Defect ID:
DEFECT000526403
Technical Severity:
High
Reason Code:
Design Limitation
Probability:
Medium
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
In ICX64xx-C12 device, reports error as "No space left on device" while booting.
Condition:
This issue happens only in the ICX64xx-C12 device, when the device tries to store the core files in
the flash where it report out of space, as another core file is present already.
Workaround:
Delete the core files in OS mode.
Defect ID:
DEFECT000529552
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
Low
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
PoE/PoE+
Symptom:
Continuous logs are observed in the console of the FastIron SX1600 device, not allowing the user to
configure any commands.
Condition:
The issue will be observed in a FastIron SX 1600 device port where LLDP and inline power are
enabled, if the port status goes to PD detection fault, the LLDP polls the faulty port
FastIron Software Release 08.0.30g Release Notes 136
Defect ID:
DEFECT000530578
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
Medium
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 07.4.00
Technology Area:
Other IPv4
Symptom:
IP reachability issues are observed between hosts in specific subnets connected in different VLANs
during event of a switch fabric hotswap.
Condition:
None
Defect ID:
DEFECT000532589
Technical Severity:
Medium
Reason Code:
Design Limitation
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
Customer running the port scan utility nmap tool to scan the ICX switch. After few days, SSHv2
stopped spawning new sessions
Condition:
Run the nmap tool to scan the ICX switch for long hours. After few days, attempt to SSH to the ICX
switch
Defect ID:
DEFECT000533281
Technical Severity:
Medium
Reason Code:
Will Not Fix
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
In order to disable Optical-Monitor, "No Optical-Monitor xxx" accepts any value. No Optical-
Monitor should reject any values.
Condition:
Bring up Interface ethernet 1/2/1 (for e.g.)
Configure Optical-monitor 10 on Interface 1/2/1 of ICX6450.
Then, execute No optical-monitor 100
Workaround:
N/A
There is no workaround, this does not have any functionality impact.
Recovery:
N/A
Defect ID:
DEFECT000533382
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
Low
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 07.2.00
Technology Area:
Hitless Switchover, Failover,
Hotswap, OS U/G
Symptom:
The active management module of SX800 device unexpectedly reloads without stack trace.
Condition:
If the SX800 device is up for more than 1325 days, the active management module resets
unexpectedly.
Defect ID:
DEFECT000533770
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 07.4.00
Technology Area:
DHCP (IPv4)
Symptom:
Upon DHCP renewal of clients, ARP is resolved to the non-primary port of trunk instead of primary
port in the ICX 6610 device.
Condition:
This issue is observed only when DHCP snooping is configured over a LAG interface.
FastIron Software Release 08.0.30g Release Notes 137
Defect ID:
DEFECT000533795
Technical Severity:
High
Reason Code:
Will Not Fix
Probability:
Medium
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.4.00
Technology Area:
ARP
Symptom:
In ICX6610 device, CPU goes high after ARP age out even with continuous traffic
Condition:
After ARP ages out, the packets are trapped to CPU resulting in loading the CPU of the ICX6610
device
Defect ID:
DEFECT000533913
Technical Severity:
Critical
Reason Code:
Will Not Fix
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
Component
Symptom:
System unexpectedly reloads after few minutes.
Condition:
This issue is observed during a downgrade from 8020 to 8010f
Workaround:
Consider avoiding the downgrade from a major release (8020) to a lower patch release (8010f)
Defect ID:
DEFECT000535464
Technical Severity:
Medium
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 05.1.00
Technology Area:
MAC ACLs
Symptom:
IPv6 packets are denied when MAC filter is configured in FESX device.
Condition:
On FESX, upon configuring MAC filter on the interface, IPv6 packets are dropped.
Defect ID:
DEFECT000535565
Technical Severity:
Medium
Reason Code:
Already Fixed in Release
Probability:
High
Product:
IronWare
Technology:
Traffic Management
Reported In Release:
FI 07.2.02
Technology Area:
Buffer Queue Management
Symptom:
Protocol flaps or re-convergence fails due to system's inability to transmit packets (packet loss) from
any management card/module or line card/module port into the network.
Condition:
Unrecoverable internal PCI error.
Recovery:
Hotswap the affected module or reload the management module to clear the problem.
Defect ID:
DEFECT000535762
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 07.4.00
Technology Area:
Web Authentication
Symptom:
After customer upgraded to 7.4x webauth stop working for users
Condition:
Customer upgraded multiple switches from 07.0.01 to 07.4.00d. "After the upgrade, webauth would
no longer work
Recovery:
Customer tried downgrading back to 07.0.01 to recovery with no success.
Defect ID:
DEFECT000536398
Technical Severity:
High
Reason Code:
Already Fixed in Release
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SFLOW
Symptom:
In FastIron stack devices, the sflow configuration on link aggregated member ports are lost after
powering off the standby unit followed by stack switch over.
Condition:
This issue would occur only when the standby unit is powered off followed by a stack switch over on
FI stack devices that has sflow configured on LAG member ports.
FastIron Software Release 08.0.30g Release Notes 138
Defect ID:
DEFECT000536448
Technical Severity:
High
Reason Code:
Already Fixed in Release
Probability:
Medium
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.10
Technology Area:
Link Aggregation
Symptom:
ICX7750 device with LAG/Trunk configured, unexpectedly reboots when the traffic is stopped and
restarted.
Condition:
With LAG/Trunk configured in ICX7750, when the traffic is stopped and restarted the device
unexpectedly goes for reload.
Defect ID:
DEFECT000536874
Technical Severity:
High
Reason Code:
Already Fixed in Release
Probability:
Low
Product:
IronWare
Technology:
Management
Reported In Release:
FI 07.4.00
Technology Area:
DHCP (IPv4)
Symptom:
DHCP release messages from DHCP clients are not processed in ICX6610 device.
Condition:
When the ARP ages out for the DHCP client, the DHCP release messages are not processed by
ICX6610 device
Defect ID:
DEFECT000537583
Technical Severity:
High
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.10
Technology Area:
MAC ACLs
Symptom:
In FastIron SX800 device, when member VLAN is added under topology group for MRP, high CPU
along with OSPF and VRRP disruption may be noticed that lasts around 30 secs.
Condition:
This issue happens while adding new member VLANs to existing topology group, high CPU may be
observed in the SX800 device.
Recovery:
The device recovers on itself after 30 to 40 secs of high CPU or OSPF/VRRP disruption
Defect ID:
DEFECT000537620
Technical Severity:
Medium
Reason Code:
Already Fixed in Release
Probability:
High
Product:
IronWare
Technology:
Stacking
Reported In Release:
FI 08.0.10
Technology Area:
Hitless Switchover, Failover,
Hotswap, OS U/G
Symptom:
Stack MAC address configuration is missing causing dynamic LAG does not form
Condition:
Failover or switchover of stack unit.
Recovery:
Manually configure the stack mac address
Defect ID:
DEFECT000538474
Technical Severity:
Critical
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 08.0.30
Technology Area:
Link Aggregation
Symptom:
While downgrading the software in FastIron device where the configuration has 10 member ports in
LAG from 8.0.20, the device may reload unexpectedly.
Condition:
FastIron device while downgrading from 8.0.20 to lower versions with maximum number of LAG
member ports, the device would reload unexpectedly.
FastIron Software Release 08.0.30g Release Notes 139
Defect ID:
DEFECT000539843
Technical Severity:
Critical
Reason Code:
Already Fixed in Release
Probability:
Low
Product:
IronWare
Technology:
System
Reported In Release:
FI 07.4.00
Technology Area:
Component
Symptom:
The ICX6610 device starts getting InErrors / CRC errors due to SFI link down events detected in
PHY after certain period.
Condition:
After running error free for certain period of time (1/2 hour to 3 hours), the ICX6610 device starts
getting InErrors / CRC errors due to SFI link down events detected in PHY
Defect ID:
DEFECT000540905
Technical Severity:
Critical
Reason Code:
Feature/Function Not Supported
Probability:
Low
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.3.00
Technology Area:
Link Aggregation
Symptom:
SX device running FI 7300 image with LAG configuration, may reload spontaneously while booting
up.
Condition:
This issue happens with LAG configuration on SX device loaded with 7300 image, resutling in
device reset spontaneously.
Defect ID:
DEFECT000541002
Technical Severity:
Medium
Reason Code:
Design Limitation
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
SSH - Secure Shell
Symptom:
Customer running the port scan utility nmap tool to scan the ICX switch. After few days, SSHv2
stopped spawning new sessions.
Condition:
Run the nmap tool to scan the ICX switch for long hours. After few days, attempt to SSH to the ICX
switch.
Defect ID:
DEFECT000541190
Technical Severity:
Low
Reason Code:
Already Fixed in Release
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
NTP - Network Time Protocol
Symptom:
Time stamp in Syslog message changes each time when the "show log" command is executed in
frequent interval such as 1 second.
Condition:
Execute the "show log" command on the ICX switch every 1 second interval.
Defect ID:
DEFECT000541620
Technical Severity:
High
Reason Code:
Will Not Fix
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 07.4.00
Technology Area:
Component
Symptom:
In FastIron SX800 device, the SX-FI-48GPP line cards does not boot/initialize properly at certain
instances.
Condition:
When SX-FI-48GPP modules with serial numbers ending in JXXX (fourth from the last character is a
"J"), is used on SX800/1600 device, the line cards are not recognised after throwing an error.
Workaround:
None known.
Recovery:
After reloading the chassis on one of the affected code versions, enter "enable module <module-id>"
for the affected module. The module will initialize and run until the chassis is again reloaded.
FastIron Software Release 08.0.30g Release Notes 140
Defect ID:
DEFECT000542408
Technical Severity:
Medium
Reason Code:
Feature/Function Not Supported
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.10
Technology Area:
CLI
Symptom:
In ICX 6650 deivce, "dm pp-dev 0 read-buff ch5" command to dump the CPU registers throws error.
Condition:
In ICX6650 device, when the dm pp-dev 0 read-buff ch5" command is issued error is thrown.
Defect ID:
DEFECT000542523
Technical Severity:
High
Reason Code:
Design Limitation
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.3.00
Technology Area:
VLAN
Symptom:
When ICX6610 device, receives 10,000 streams of traffic with different MAC, VLAN pair, the
device could able to learn only 9500 MAC address.
Condition:
This issue happens only when 10,000 streams of traffic with different MAC, VLAN is sent to
ICX6610 device where the device could not learn all of them.
Defect ID:
DEFECT000543236
Technical Severity:
Medium
Reason Code:
Already Fixed in Release
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SFLOW
Symptom:
In FastIron stack devices, the "sflow forwarding" configuration gets lost after failover.
Condition:
When "sflow forwarding" is enabled on the interfaces of both active and standby units, after
switchover and powering off the new active unit, the sFlow configuration gets removed from the new
standby unit.
Defect ID:
DEFECT000543334
Technical Severity:
High
Reason Code:
Already Fixed in Release
Probability:
High
Product:
IronWare
Technology:
Layer 2
Reported In Release:
FI 07.4.00
Technology Area:
Link Aggregation
Symptom:
LACP stuck in ‘Init’ state after ICX6610 stack reloaded
Condition:
When LAG is configured on top of SSTP and ICX6610 stack is reloaded.
Defect ID:
DEFECT000544763
Technical Severity:
High
Reason Code:
Will Not Fix
Probability:
Low
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 07.4.00
Technology Area:
Other IPv4
Symptom:
The standby unit of ICX6610 stack device is not accessible after DHCP release/ renew.
Condition:
After DHCP release / renew test, the standby unit of ICX6610 device becomes non-responsive.
Defect ID:
DEFECT000545028
Technical Severity:
Medium
Reason Code:
Not Reproducible
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.20
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
The ICX switch was configured with the CLI command "no snmp-server ap authentication", but the
SNMP authentication APs were still generated and sent out to AP host.
Condition:
Configure the ICX switch with the CLI command "no snmp-server ap authentication". Connect
SNMP ap receiver to the ICX switch and observe the SNMP aps for authentication messages.
FastIron Software Release 08.0.30g Release Notes 141
Defect ID:
DEFECT000545499
Technical Severity:
Medium
Reason Code:
Will Not Fix
Probability:
High
Product:
IronWare
Technology:
System
Reported In Release:
FI 08.0.20
Technology Area:
Optics
Symptom:
When the 1G optic link of the ICX6650 is connected to other vendor’s switch and configured as
"speed-duplex 1000-full", the link would not come up.
Condition:
When a 1G optic from the ICX6650 is connected to a link partner which does not support auto-
negotiation, the link would not come up.
Defect ID:
DEFECT000545987
Technical Severity:
Medium
Reason Code:
Not Reproducible
Probability:
High
Product:
IronWare
Technology:
Security
Reported In Release:
FI 07.2.02
Technology Area:
FIPS
Symptom:
Establish https connection through SSL3.0 version is vulnerable.
Reference: CVE-2014-3566 (POODLE): http://www.cve.mitre.org/cgi-
bin/cvename.cgi?name=CVE-2014-3566
Condition:
Establish https connection through SSL3.0 version is vulnerable.
Defect ID:
DEFECT000545997
Technical Severity:
High
Reason Code:
Design Limitation
Probability:
High
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.10
Technology Area:
SSH - Secure Shell
Symptom:
Customer running the port scan utility nmap tool to scan the ICX switch. After few days, SSHv2
stopped spawning new sessions.
Condition:
Run the nmap tool to scan the ICX switch for long hours. After few days, attempt to SSH to the ICX
switch.
Defect ID:
DEFECT000550244
Technical Severity:
High
Reason Code:
Design Limitation
Probability:
Medium
Product:
IronWare
Technology:
Management
Reported In Release:
FI 08.0.30
Technology Area:
PoE/PoE+
Symptom:
Some Access Points that have two PD ports, but with a single controller get detected as legacy device
by a Switch (PSE).
Condition:
PD devices with two PD ports could draw power from either or one of the ports. This is not
deterministic.
Workaround:
Enable PoE on only one of the PD ports of the two ports connected to the AP
Recovery:
Enable PoE on only one of the PD ports of the two ports connected to the AP
Defect ID:
DEFECT000550818
Technical Severity:
Critical
Reason Code:
Not Reproducible
Probability:
High
Product:
IronWare
Technology:
Layer 3
Reported In Release:
FI 08.0.10
Technology Area:
VRRP & VRRP-E (IPv4)
Symptom:
The ICX7750 device unexpectedly reloads, when show running config is issued.
Condition:
This issue happens when the ICX7750 has the VRRP configuration stored in the flash and show
running config is issued after boot up. This is not always seen but is dependent on configuration that
precedes the VRRP configuration in the running configuration.