SAF Tehnika AS ARANETTRH Hybrid Digital Transmission System User Manual Aranet TRH sensor datasheet fcc

SAF Tehnika A/S Hybrid Digital Transmission System Aranet TRH sensor datasheet fcc

User Manual

Download: SAF Tehnika AS ARANETTRH Hybrid Digital Transmission System User Manual Aranet TRH sensor datasheet fcc
Mirror Download [FCC.gov]SAF Tehnika AS ARANETTRH Hybrid Digital Transmission System User Manual Aranet TRH sensor datasheet fcc
Document ID3748197
Application IDiNmznPWdfyKXxmOPSrCmcA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize75.2kB (940057 bits)
Date Submitted2018-02-09 00:00:00
Date Available2018-03-26 00:00:00
Creation Date2018-02-07 12:06:18
Producing SoftwareAdobe PDF library 10.01
Document Lastmod2018-02-07 12:06:19
Document TitleAranet TRH sensor datasheet fcc
Document CreatorAdobe Illustrator CS6 (Windows)

T/RH
Aranet T/RH SENSOR
Aranet SENSOR Datasheet
Measurements
Temperature
Relative Humidity
Line of Sight Range
3 km/ 1.9mi
Operating environment
Indoor and Outdoor use
Transmitter power
14 dBm
Frequency
Depends on gateway instructions
Temperature
-40°C to 60°C/
-40°F to 140 °F
Relative Humidity
0% to 100%
-10°C to 60°C/ 14°F to 140°F
0.4°C / 0.72°F
-20°C to -10°C/ -4°F to 14°F
0.6°C / 1.08°F
-40°C to -20°C/ -40°F to 14°F
0.9°C/ 1.62°F
Relative Humidity measurement
accuracy
0 to 80% @ 30°C/ 86 °F
4%
80% to 95% @ 30°C/ 86°F
6%
Data Transmission
Every 10 minutes
Data Protection
Data encryption
Measurement range
Temperature measurement
accuracy
Power options
Battery life @20°C / 68°F
Operating temperature
2 AAA Alkaline batteries (Zn/Mn02)
2 AAA Lithium batteries (Li/FeS2)
Up to 7 years with Alkaline batteries
Up to 10 years with Lithium batteries
-20°C to 55°C / -4°F to 131°F with Alkaline batteries
-40°C to 60°C / -40°F to 140°F with Lithium batteries
Operating humidity
0% to 100% non-condensing*
Dimensions
115x44x25 mm / 4.5x1.7x1 in
Weight
65g / 2.3 oz with Alkaline batteries
57g / 2 oz with Lithium batteries
Construction
ASA Plastic
Protection class
IP42
CE Marking
Yes
Included
2 AAA Alkaline batteries, string
* Recommended humidity operating range is 20% to 80% .RH (non-condensing) over –10 °C to 60 °C/ 14°F to 140°F.
Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.
Terms of use The Customer is obliged to guarantee the usage, maintenance and preservation of the Equipment at their own expense in a way that
excludes the Equipment’s theft, loss, destruction, harming and/or damaging (including as a result of mechanical damages, moisture, liquid related
damages, lightning and/or other similar events). Sensors are made to be placed vertically (with the ventilation opening facing down) thus being
resistive to humidity.
FCC Compliance statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
•Reorient or relocate the device.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from the one the receiver is connected to.
•Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Importatnt Exposure to Radio Frequency Radiation.
20 cm distance has to be maintained between the antenna and user. Under such configuration, the FCC radiation
exposure limits set forth for an population/uncontrolled environment can be satisfied.
Changes or modifications not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
Aranet devices do not contain serviceable parts. Warranty will not be applicable in the event Aranet
devices have been opened.
The information presented in this guide is the property of SAF Tehnika, JSC. No part of this document may be
reproduced or transmitted without proper permission from SAF Tehnika, JSC.
The specifications or information contained in this document are subject to change without notice due to continuing
introduction of design improvements. If there is any conflict between this document and compliance statements, the
latter will supersede this document.
SAF Tehnika, JSC has no liability for typing errors in this document or damages of any kind that result from the use of
this document.
To get up to date information about accessories and their availability, please contact sales representative.
Copyright Notice
Copyright © 2017 SAF Tehnika, JSC. All rights reserved.
Industry Canada Regulatory Statement
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
How to: Pair sensors to Aranet
1. Pair sensors with Aranet PRO
Aranet PRO supports several types of sensors. In order to connect them to the system the same steps apply for all
types of sensors.
(1) You should physically be located within around 20 meters of Aranet PRO.
(2) In order to open the sensor follow the individual sensor’s instructions (see image above). Once it is opened the
battery compartment will be exposed.
(3) Go to Aranet PRO Settings screen.
(4) Choose “Sensors” menu.
(5) Click “Add sensor” button.
(6) Insert sensor’s battery/-ies.
(7) Red LED light will flash on the sensor. Three short flashes followed by a long flash will signal a connection failure,
the pause between flashes will be the same. In a successful pairing the long flash will follow immeadiately after a short
flash. Looking at the LED light can save time while pairing sensors, however, Aranet PRO will also display a notification
about a successful or unsuccessful pairing.
(8) Close the sensor following respective sensor instructions.
(9) Now you can rename the sensor, set thresholds for alarms, add it to favorites. After completing your tasks click save
button.
2. Pair sensors with Aranet MINI
(1) Tap , then choose Sensors menu and tap the Setup button.
(2) Set up a sensor by following the instructions on the screen. After successfully setting up a sensor, the sensor ID and
the name of the sensor will appear on the left side of the screen. Sensors are given name “SENS ”
automatically. Tap the name of the sensor to give it a new name with length up to 8 symbols. In
order to remove a sensor just press the sign next to it.
(3) Set up other sensors in the same manner.
• To add more than 6 sensors, press the page button on top.
• To change the order of the sensors, press and . Then press on the sensors you want to move and
then – where you want to move it to.
• Tap the home button to return to the main menu.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Producer                        : Adobe PDF library 10.01
Format                          : application/pdf
Title                           : Aranet TRH sensor datasheet fcc
Creator Tool                    : Adobe Illustrator CS6 (Windows)
Create Date                     : 2018:02:07 12:06:18+03:00
Metadata Date                   : 2018:02:07 12:06:19+02:00
Modify Date                     : 2018:02:07 12:06:19+02:00
Thumbnail Width                 : 256
Thumbnail Height                : 120
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 12951 bytes, use -b option to extract)
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : False
Max Page Size W                 : 595.276367
Max Page Size H                 : 841.890137
Max Page Size Unit              : Points
Font Name                       : OpenSans-Light, OpenSans, OpenSans-Bold, OpenSans-Extrabold, OpenSans-Regular
Font Family                     : Open Sans, Open Sans, Open Sans, Open Sans, OpenSans Regular
Font Face                       : Light, Regular, Bold, Extrabold, Regular
Font Type                       : Open Type, Open Type, Open Type, Open Type, Unknown
Font Version                    : Version 1.10, Version 1.10, Version 1.10, Version 1.10, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168
Font Composite                  : False, False, False, False, False
Font File Name                  : OpenSans-Light.ttf, OpenSans-Regular.ttf, OpenSans-Bold.ttf, OpenSans-ExtraBold.ttf, MyriadPro-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE 320 C, PANTONE 186 C
Swatch Group Name               : Default Swatch Group
Swatch Group Type               : 0
Swatch Colorant Swatch Name     : PANTONE 186 C, PANTONE 320 C
Swatch Colorant Type            : SPOT, SPOT
Swatch Colorant Tint            : 100.000000, 100.000000
Swatch Colorant Mode            : CMYK, CMYK
Swatch Colorant Cyan            : 12.000000, 80.000000
Swatch Colorant Magenta         : 100.000000, 22.000000
Swatch Colorant Yellow          : 91.000000, 32.000000
Swatch Colorant Black           : 3.000000, 0.000000
Document ID                     : xmp.did:F3AE8F33EE0BE811B4EAE33AD6D06795
Instance ID                     : uuid:9ce2dd9d-e5c6-4502-8aa8-2d303b4ecb0f
Original Document ID            : xmp.did:F54E16E47192E7118ABBA3B220E4C004
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:5e92bf13-3787-47d0-9aab-82ca943b5b6a
Derived From Document ID        : xmp.did:51D470385CFFE711992EF850E11B2DCB
Derived From Original Document ID: xmp.did:F54E16E47192E7118ABBA3B220E4C004
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:F54E16E47192E7118ABBA3B220E4C004, xmp.iid:F3AE8F33EE0BE811B4EAE33AD6D06795
History When                    : 2017:09:05 22:39:11+03:00, 2018:02:07 12:06:16+02:00
History Software Agent          : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows)
History Changed                 : /, /
Manifest Link Form              : EmbedByReference
Manifest Reference File Path    : C:\Users\vizmab\Desktop\vizma temporary\Leaflets, datasheets\fcc datasheets\exclamation-warning-png-image-97509.png
Page Count                      : 3
Creator                         : Adobe Illustrator(R) 16.0
For                             : Vizma Bramane,
Bounding Box                    : 0 0 1824 842
Container Version               : 11
Creator Version                 : 16
Image Height                    : 842
Image Width                     : 1824
Image Size                      : 1824x842
Megapixels                      : 1.5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: W9Z-ARANETTRH

Navigation menu