SAFRAN Identity and Security MPHAC001B Control Access Terminal User Manual MA Lite Installation Guide V3
SAFRAN MORPHO Control Access Terminal MA Lite Installation Guide V3
User Manual - MA-Lite - Installation Guide V3.pdf
MorphoAccess® SIGMA Lite Series Installation Guide COPYRIGHT© 2015 Morpho Osny, France MorphoAccess® SIGMA Lite Series – Installation Guide 2015_2000007248-V1 - Draft June 2015 MorphoAccess® SIGMA Lite Series – Installation Guide Warning Warning COPYRIGHT© 2015 Morpho. All rights reserved. Information in this document is subject to change without notice and do not represent a commitment on the part of Morpho. This document contains information of a proprietary nature to Morpho and is submitted in confidence for a specific purpose. The recipient assumes custody and control and agrees that this document will not be copied or reproduced in whole or in part, nor its contents revealed in any manner or to any person except to meet the purpose for which it was delivered. This caveat is applicable to all the pages of this document. This manual makes reference to names and products that are trademarks of their respective owners. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Revision History Revision History The table below contains the history of changes made to the present document. Version Date Reference 01 June 2015 2015_0000007248-V1 - Draft 2015_2000007248-V1 - Draft June 2015 Description Document creation This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Table of Content Table of Content Warning ........................................................................................................................................ 2 Revision History ............................................................................................................................ 3 Section 1 : Introduction ................................................................................................................ 8 MorphoAccess® SIGMA Lite Series terminals ............................................................................ 9 Scope of the document............................................................................................................ 10 Safety Instructions ................................................................................................................... 11 Wiring Recommendations ................................................................................................... 11 Europe information ............................................................................................................. 12 USA information .................................................................................................................. 12 Canada information............................................................................................................. 13 Eco-design...................................................................................... Erreur ! Signet non défini. Recommendations for terminal implementation.................................................................... 14 Section 2 : General Description .................................................................................................. 17 Box opening ............................................................................................................................. 18 Components of the initial package ......................................................................................... 19 Terminal's front view description ............................................................................................ 20 Terminal's rear view description ............................................................................................. 21 MorphoAccess® SIGMA Lite Series Technical Characteristics ................................................. 22 Section 3 : Installation Procedure ............................................................................................... 24 Before proceeding to the installation ..................................................................................... 25 Installation .............................................................................................................................. 26 Required tools (not supplied)............................................................................................... 26 Equipment from the initial package to use ......................................................................... 26 Step by step procedure ........................................................................................................ 27 Section 4 : Electrical Interface .................................................................................................... 29 Wiring overview ...................................................................................................................... 30 Power Supply ........................................................................................................................... 31 External Power supply ......................................................................................................... 31 POE (Power Over Ethernet) ................................................................................................. 31 Output Relay ........................................................................................................................... 32 Nominal characteristics of relay .......................................................................................... 32 Example of connection for electrical door locks .................................................................. 33 Tamper Switch......................................................................................................................... 34 Operating principle for the switch ....................................................................................... 34 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Table of Content Nominal characteristics of switch block .............................................................................. 34 Wiegand port wiring ............................................................................................................... 35 Wiegand input wiring .......................................................................................................... 35 Wiegand output wiring ....................................................................................................... 36 The controller supports neither LED1 nor LED2 signals ....................................................... 37 The controller supports only LED1 signal ............................................................................ 37 The controller supports LED1 and LED2 signals .................................................................. 37 Data Clock Input .................................................................................................................. 38 Data Clock Output ............................................................................................................... 39 RS-485 port wiring................................................................................................................... 40 GPIO wiring ............................................................................................................................. 41 Single Door Access Control (SDAC) implementation ............................................................... 42 Ethernet connection ................................................................................................................ 43 Default Ethernet configuration ........................................................................................... 43 Recommendations for RJ45 wiring ...................................................................................... 43 External USB connection ......................................................................................................... 44 Wi-Fi™ dongle installation ...................................................................................................... 45 Section 5 : User Interface ........................................................................................................... 46 Modes for controlling access rights ........................................................................................ 47 Introduction ......................................................................................................................... 47 Identification mode ............................................................................................................. 47 Authentication (verification) mode ..................................................................................... 47 Multi-factor mode ............................................................................................................... 48 Proxy mode .......................................................................................................................... 48 External database mode (also called polling mode) ........................................................... 48 Configuring the terminal ......................................................................................................... 50 MorphoAccess® 500 or J Series legacy mode ...................................................................... 50 Bioscrypt 4G Series legacy mode ......................................................................................... 50 MorphoAccess® SIGMA Lite Series native mode ................................................................. 51 Anti-tamper / anti-pulling switches ........................................................................................ 52 Section 6 : Accessories, Software Licenses and PC Applications ................................................ 53 Compatible Accessories, Licenses and Software ..................................................................... 54 Compatible PC applications .................................................................................................... 55 Section 7 : Recommendations .................................................................................................... 56 Notice................................................................................................................................... 57 General precautions ............................................................................................................ 57 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Table of Content Areas containing combustibles............................................................................................ 57 Specific precautions for terminals equipped with a contactless smartcard reader ............ 57 Ethernet connection ............................................................................................................ 57 Date / Time synchronization ............................................................................................... 57 Cleaning precautions ........................................................................................................... 58 Legacy mode ........................................................................................................................ 58 Main principles ........................................................................................................................ 62 Most useful areas for biometric data...................................................................................... 63 Position of finger ..................................................................................................................... 64 Finger height ........................................................................................................................ 64 Finger angle ......................................................................................................................... 64 Finger inclination ................................................................................................................. 65 Finger rotation ..................................................................................................................... 65 Troubleshooting ...................................................................................................................... 66 How to get the latest versions of documents ......................................................................... 68 Documents concerning the MorphoAccess® terminal ............................................................ 69 Documents about installing the terminal ............................................................................ 69 Documents about administrating / using the terminal ....................................................... 69 Documents for the developer .............................................................................................. 69 Release note ........................................................................................................................ 70 Troubleshooting ...................................................................................................................... 72 The terminal IP address is unknown or it is not possible to connect to the terminal.......... 72 The sensor is switched off .................................................................................................... 72 The terminal returns erratic responses to Ping commands ................................................ 72 Technical Support and Hotline ................................................................................................ 73 North America ..................................................................................................................... 73 South America ..................................................................................................................... 73 South Africa ......................................................................................................................... 73 India: .................................................................................................................................... 73 Europe and rest of the world: .............................................................................................. 73 Web site ............................................................................................................................... 73 Annex 1 : Finger Placement Recommendations ...................................................................... 61 Annex 2 : Bibliography ............................................................................................................. 67 Annex 3 : Support .................................................................................................................... 71 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Table of Figures Table of Figures Figure 1: Implementation Recommendations .............................................................................15 Figure 2: Box Opening..................................................................................................................18 Figure 3: Box Content ..................................................................................................................19 Figure 4: MorphoAccess® SIGMA Lite Series terminal front view...............................................20 Figure 5: MorphoAccess® SIGMA Lite Series terminal rear view ................................................21 Figure 6: Removing wall frame ....................................................................................................25 Figure 7: Drilling template ...........................................................................................................27 Figure 8: Wall plate fixing ............................................................................................................28 Figure 9: Cabling layout ...............................................................................................................30 Figure 10: Power supply wiring ...................................................................................................31 Figure 11: Output relay wiring .....................................................................................................32 Figure 12: Example of electric latch connection .........................................................................33 Figure 13: Tamper switch wiring .................................................................................................34 Figure 14: Wiegand input wiring .................................................................................................35 Figure 15: Wiegand output wiring ...............................................................................................36 Figure 16: Wiegand port wiring – DataClock ...............................................................................38 Figure 17: Wiegand port wiring – Data Clock ..............................................................................39 Figure 18: RS-485 port wiring – RS485 ........................................................................................40 Figure 19: GPIO wiring .................................................................................................................41 Figure 20: SDAC wiring.................................................................................................................42 Figure 21: RJ45 wiring ..................................................................................................................43 Figure 22: External USB connection ............................................................................................44 Figure 23: Wi-Fi™ dongle installation ..........................................................................................45 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Section 1 : Introduction 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction MorphoAccess® SIGMA Lite Series terminals Congratulations for choosing a MorphoAccess® SIGMA Lite Series Automatic Fingerprint Recognition Terminal. MorphoAccess® SIGMA Lite Series provides an innovative and effective solution for access control applications using Fingerprint Verification or/and Identification. Among a range of alternative biometric technologies, the use of finger imaging has significant advantages: each finger constitutes an unalterable physical signature, developed before birth and preserved until death. Unlike DNA, a finger image is unique to each individual - even identical twins. MorphoAccess® SIGMA Lite Series integrates Morpho image processing and feature matching algorithms. This technology is based on lessons learned during 25 years of experience in the field of biometric identification and the creation of literally millions of individual fingerprint identification records. We believe you will find the MorphoAccess® SIGMA Lite Series fast, accurate, easy to use and suitable for physical access control. The MorphoAccess® SIGMA Lite Series offers the following advantages: high quality optical sensor (IQS quality sensor), supports multiple input/output interfaces used in the physical access control industry, Local Area Network interface for easy interaction with other host systems ; LAN and WLAN possibilities (Wi-Fi™ as an option), compact size for easy installation and integration into your available office space, intuitive man machine interface with touch panel and display, that is easy to use in both setup and operational modes, To ensure the most effective use of your MorphoAccess® SIGMA Lite Series terminal, we recommend that you read this Installation Guide completely. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Scope of the document This guide deals with the installation of MorphoAccess® SIGMA Lite Series, which is made up of following list of products: MA SIGMA Lite Series Contactless smartcard reader Biometrics Marketing Name iCLASS MA SIGMA Lite MA SIGMA Lite iClass MA SIGMA Lite Multi MA SIGMA Lite Prox MA SIGMA Lite+ MA SIGMA Lite+ iClass MA SIGMA Lite+ Multi MA SIGMA Lite+ Prox ® Water Resistant Regulatory Model Number (*) MPH-AC001A MPH-AC001B MPH-AC001B MPH-AC001A MPH-AC001A MPH-AC001B MPH-AC001B MPH-AC001A Touch ® MIFARE screen ® ® DESFire Prox NFC (*) The Regulatory Model Number is the main product identifier in the regulatory documentation and test reports associated to the product NOTA : MA stands for MorphoAccess® 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 10 MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Safety Instructions means Direct Current (DC) The installation of this product should be made by a qualified service Person and should comply with all local regulations. It is strongly recommended to use a class II power supply at 12VDC-24VDC and 1A minimum (at 12VDC) in conformity with Safety Electrical Low Voltage (SELV). The power supply cable length should not exceed 10 meters. This product is intended to be installed with a power supply complying with IEC60950-1, in accordance with the NEC Class 2 requirements; or supplied by a listed IEC60950-1 external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 1A minimum or 24VDC, 0,5A minimum. In case of building-to-building connection (power source in a building, and terminal in another building), it is recommended to connect the 0V of the power supply to the earthing system of the building. And the terminal block Power Ground must be connected with the earthing system of the other building. Note that all connections of the MorphoAccess® SIGMA Lite Series terminal described hereafter are of SELV (Safety Electrical Low Voltage) type. Wiring Recommendations Morpho recommends using a gauge AWG20 for 12VDC power supply (when the terminal is not powered using POE feature). The voltage must be measured on the product block connector and must be equal to 12VDC-24VDC (-15% / +10%) For information, this table shows the maximum drop voltage observed on the terminal MorphoAccess® SIGMA Lite Series, depending on the length of the cable: Gauge AWG Diameter (mm) Maximum drop voltage @ 1m (V) Maximum drop voltage @ 5m (V) Maximum drop voltage @ 10m (V) 20 0.81 0.03 0.17 0.33 22 0.64 0.05 0.26 0.53 24 0.51 0.08 0.42 0.84 V2 V1 Drop voltage = loss of power due to wire resistance and its length: V2 = V1 – Drop voltage 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 11 MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Regulations Europe information MorphoAccess® SIGMA Lite Series are intended to be used for professional application only (buildings, airport...). Residential usage isn’t on application domain of these products. Morpho hereby declares that the MorphoAccess® SIGMA Lite Series terminal has been tested and it complies with following listed standards: EMC Directive 2004/108/CE – Class A R&TTE Directive (1999/5/CE). ROHS Directive 2011/65. Note: European Directive ErP isn’t applicable USA information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Responsible Party: Morpho 11, boulevard Gallieni 92130 Issy-les-Moulineaux – France NOTA : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 12 MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Consult the dealer or an experienced radio/TV technician for help. Shielded cables must be used with this unit to ensure compliance with category B FCC restrictions. Canada information WARNING TO USERS IN THE CANADA / ATTENTION POUR LES UTILISATEURS AU CANADA This device complies with Industry Canada license-exempt RSS standard(s), and with ICES 003 standard for version(s) without RFID reader. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 13 MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Recommendations for terminal implementation Every installation is unique. Sometimes the issues are well defined and can be handled in a standard fashion; sometimes the issues are very specific and may not be immediately recognizable. Morpho recommends following these steps for a successful installation: Plan the installation - Choose the type of hardware required, decide if a network is required, and decide on the location and number of required terminals. Unpack all items - Unpack all items and check against the packing list. Install network hardware components - Install the cabling and components needed to run the system. Install software - Install the software needed to set up the terminals. Pre-configure device - Connect the terminals to the Ethernet, supply power to the terminals, and pre-configure the terminals. Mount devices - Mount the terminals in their final locations Power distribution and device hook up - Connect the terminals wiring via the back panel. Power-up procedure - Check the power connections, and then start the system safely. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 14 MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction To secure properly an access, Morpho recommends installing the MorphoAccess® SIGMA Lite Series terminal as a part of the typical Access Control environment, as the one described in the figure below. NON SECURED AREA SECURED AREA Dry Contact TCP/IP, Wiegand, Dataclock or RS485 ACCESS CONTROLLER ALARM ACCESS CONTROL SYSTEM ELECTRIC LATCH (*) MorphoAccess® SIGMA Lite Terminal Dry Contact (*) OR EQUIVALENT Figure 1: Implementation Recommendations This environment comprises: The MorphoAccess® SIGMA Lite Series terminal itself Its role is to perform one-to-many biometric identification or one-to-one biometric verification, i.e. to identify the individual who is presenting his finger on the terminal sensor by comparing his biometric data with the references previously stored in the terminal database (in the form of biometric templates) or to verify his identity using the reference stored in a contactless card presented to the terminal. An Access Controller (3rd party product) The Controller is the element which controls the access rights of the individuals to the secured area. For that reason, it must be located in the secured area. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 15 MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction The individuals who are authorized to access the secured area have their User ID listed in a so-called "White List" (in contrast with a black list). The MorphoAccess® SIGMA Lite Series terminal and the Controller are communicating using one of the available protocol (TCP/IP, Wiegand or Dataclock, or RS485). The typical process is described below: After access request, and local checks, the MorphoAccess® SIGMA Lite Series terminal sends the User ID, and the result of local checks, to the Controller The Controller performs additional checks, and sends its decision to the MorphoAccess® SIGMA Lite Series terminal (which displays access granted or access denied depending on the answer), and to the electric latch of the door (though a door controller) if access is granted to the user The MorphoAccess® SIGMA Lite Series terminal sends an alarm signal to the Controller as soon as a malicious operation is detected (terminal pulled out from the wall or opened); please refer to the paragraph dealing with anti-pulling and anti-tamper switches for more explanations. The Controller is part of the global Access Control System of the secured area, which can provide useful features such as manage: white lists (i.e. for VIP), black lists (i.e. for lost user cards), an access request log (who and when, access granted or denied,..), an event log (i.e. tamper detection, access control for evacuation of the building,...). The MorphoAccess® terminal is able to work alone, without Controller, but the protection level of the secured area is lower. An Alarm (3rd party product) This element is connected to the MorphoAccess® SIGMA Lite Series terminal through a dry contact. The MorphoAccess® SIGMA Lite Series terminal sends the command to activate the Alarm as soon as a malicious operation (terminal pulled out from the wall or having its bottom cover opened out of maintenance operations) is detected; please refer to the paragraph dealing with anti-pulling and anti-tamper switches for more explanations. A Door Electric Latch or equivalent (3rd party product) The activation of this element, open the door or the gate, to provide the physical access to the protected area. The Controller is the one which sends the command to activate the latch if access is granted (i.e. if the individual's User ID is listed in the Controller White List). Connection between these two elements is done through a dry contact. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 16 MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Section 2 : General Description 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 17 MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Box opening At the box opening, components shall be extracted from the protection casing as depicted in the pictures below. Extract the wall plate (which is not screwed to the terminal) and keep it separate until the installation of the terminal is completed. The screwing of the product to the wall plate is the last stage of the installation. The protection accessory provided is optional: it is recommended in case of outdoor installation (to protect biometric module against dust, rain and direct sun rays). Figure 2: Box Opening 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 18 MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Components of the initial package Figure 3: Box Content 1. One (1) Terminal’s body 2. One (1) Wall frame 3. One (1) Pre-wired back door 4. One (1) Protection accessory (optional) to insert over the biometric sensor 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 19 MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Terminal's front view description USB port (for configuration and settings with a USB mass storage) Buzzer 2.8" WVGA touchscreen (Lite+ model) Sensor protection cap (optional) Contactless card area Logo on cover when available Optical biometrical sensor Figure 4: MorphoAccess® SIGMA Lite Series terminal front view 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 20 MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Terminal's rear view description USB port (for installation of an optional Wi-Fi™ USB dongle) RJ-45 female connector Internal Relay Terminal blocks Anti-tamper / Antipulling switches Wiegand or Data & Clock RS485 & GPIO Power supply & Tamper Switch Figure 5: MorphoAccess® SIGMA Lite Series terminal rear view 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 21 MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description MorphoAccess® SIGMA Lite Series Technical Characteristics Item Description Access control modes Identification (search for fingerprint in a local database) Authentication with contactless smartcard, with or without fingerprint check (only if terminal is equipped with a contactless smartcard reader) Multi-factor: identification or authentication (only if terminal is equipped with a contactless smartcard reader) Proxy: the access control check is fully driven by a remote system Man Machine Interface 2,8” WVGA color touchscreen LCD (Lite+ model only) Buzzer Biometrics Morpho Compact Biometric Module inside: 500dpi, 256 gray levels optical sensor. FBI PIV IQS quality sensor. False Acceptance Rate (FAR) adjustable from 1% down to 10-7% Database capacity: 3,000 users (standard) and up to 10 000 users (with specific license). Log capacity 100 000 records (standard) and up to 1 000 000 (with specific license) LAN/WLAN connection For terminal configuration and data transfer: Ethernet 10/100 Base T (MDI, MDI-X) Or Wi-Fi™ Wireless LAN (option), WEP, WPA (PSK) and WPA2 (PSK) encryption available Either TCP, TLS or SSL protocol RFID cards (depending on product version) MIFARE® 1k, 4k MIFARE® PLUS S (SL1, SL3) 2k, 4k DESFire® 2k, 4k, 8k HID iCLASS® 16kb, 32kb HID Prox 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 22 MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Serial port The serial port supports WIEGAND, DATACLOCK (ISO2) and RS485 protocols Output relay switches Access granted: 1 switch two outputs (normally “open” and normally “closed”) (30V – 2A max) USB host port External port for terminal configuration through a USB mass storage key Internal port to connect an external Wi-Fi™ USB dongle using an adapter cable. Input signals LED1/LED2 to activate the access granted relay Power supply 12 to 24 V DC power supply (1A min @12V) Or by Power Over Ethernet through RJ-45 connector Power consumption TBD Security of the terminal Anti-tamper-pulling switches. Tamper-pulling detection: one relay switch. Size and weight W x H x D: 68mm x 156mm x 62mm (2.68” x 6,14” x 2,44”) Weight : 280g Environmental conditions Operating temperature -10 °C to + 55 °C (14°F to 131°F) Operating humidity 10 % < RH < 80 % (non condensing) Storage temperature -25 °C to + 70 °C (-13°F to 158°F) Storage humidity 5% < RH < 95 % IP65 (once back door attached with the 4 screws) The terminal should be installed in controlled lighting conditions. Avoid direct exposure to sunlight or to UV lights. Certifications 2015_2000007248-V1 - Draft June 2015 CE, IEC6095-1, FCC Part 15, RSS210, Issue8 : 2010, RoHS, REACh, WEEE This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 23 MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Section 3 : Installation Procedure 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 24 MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Before proceeding to the installation Make sure that you have all the components described in “Components of the initial package” section at your disposal. Remove the wall plate. Keep this element at hand. Figure 6: Removing wall frame It is then possible to fix wall plate on the wall. The recommended height for fixing of the terminal is 1.40m (top of the product). For an optimal use the terminal must be installed in an area where the lighting conditions are controlled. Avoid direct exposure of the sensor to the sun light. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 25 MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Installation Required tools (not supplied) Two (2) raw plugs + Two (2) ø 4mm max and length 30mm screws. One (1) screwdriver adapted to screws above. One (1) Drill (with a drill bit diameter adapted to raw plugs above). One (1) hole saw (depending on installation case). A (1) Torx T10 screwdriver Deadbolt/door strike Snubber diode required to protect regulated DC power supply from inductive kickback (1N4007 diode or equivalent recommended) Separate power supply for the deadbolt/door strike based on supplier's recommendations. External relay (if required) Networking cable For UL-294 compliance, an earthed screen in the wire or around all wires to/from product is only required when the wires share space/compartment/tube with high voltage cables. Equipment from the initial package to use One (1) Terminal’s body, One (1) pre-wired back door, One (1) wall plate, One (1) Protection accessory (optional) to insert over the biometric sensor 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 26 MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Step by step procedure The recommended height for fixing of the terminal is 1.40m (top of the product). For an optimal use the terminal must be installed in an area where the lighting conditions are controlled. Avoid direct exposure of the sensor to the sun light. Power supply from electrical source shall be switched off before starting the installation. The strength of the attachment depends on the solidity of the wall on which the terminal is mounted. To ensure water tightness, the pre-wired back door has to be attached to the product with the 4 screws (refer to corresponding picture for process). 60,1mm 83,3mm 40mm min 1400mm 7,45mm Drilling the mounting holes Φ = 4mm Ø46mm max Scale 1.0 Figure 7: Drilling template 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 27 MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure If not present, drill in the wall a hole with a diameter adapted to the width of the terminal and the cable to be hosted in (see Figure 7: Drilling template. This template at scale 1:1 can be found in the Quick Installation Guide). Confirm the presence inside the hole of all the cables needed for the electrical installation (see Electrical Interface) Drill in the wall 2 holes with a diameter adapted to screws and fit them with the raw plugs (see Figure 7: Drilling template). Fixing Be sure that a sufficient space is reserved in the wall for the passage of cables, in particular for Ethernet cable and plug, and also for the Wi-Fi dongle (if applicable). Figure 8: Wall plate fixing Place the wall plate against the wall, opposite the four holes pierced in the wall (see Figure 8: Wall plate fixing). Cabling Cable for wiring shall be AWG 20 to 24, length shall be adapted to the size of the hole in the wall, to terminal connections, and to the distant between the electric source and the terminal itself. Closing Power has to be set up just after closing it. If product has to be stored for a long time (more than 48 hours), don’t forget to restore its configuration before use. Finally, lock the product with the screw at the bottom of the terminal. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 28 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Section 4 : Electrical Interface 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 29 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wiring overview Before proceeding, make sure that the person in charge of installation and connections is properly connected to earth, in order to prevent Electrostatic Discharges (ESD). Power supply ground shall not be used for peripheral ground. All other grounds can be used indifferently. Note that all connections of the MorphoAccess® SIGMA Lite Series terminal described hereafter are of SELV (Safety Electrical Low Voltage) type. Figure 9: Cabling layout 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 30 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Power Supply POE and external power supply can be used simultaneously, but when both power supplies are available, priority is given to external power supply. If the external power supply fails or is shut down, the terminal will go off and then restart using POE. External Power supply Figure 10: Power supply wiring Red Power Supply 12-24V DC In Positive 12-24 Volts, power supply Black Power ground In Ground power supply External power supply Must comply with IEC 60950-1 standard. 12V to 24V Dc (regulated and filtered) 1 Amp min at 12V. Could be provided by a 12 Volts Wiegand power supply, which complies with the Security Industry Association's Wiegand standard March 1995. If sharing power between devices, each unit must receive 1A (e.g. two units would require a 12vDC, 2A supply) POE (Power Over Ethernet) MorphoAccess® SIGMA Lite Series terminal's power supply can also be provided by the Ethernet using RJ45 connection (Power Over Ethernet mode - IEEE802.3af or IEEE802.3at type 1 compliant). 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 31 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Output Relay Figure 11: Output relay wiring 19 Yellow Relay NO Contact relay (normally open) 22 Grey Relay COM Contact relay common 21 Orange Relay NC Contact relay (normally closed) Nominal characteristics of relay Load characteristics: 1 A max @ 30 VDC (according to the safety extra low voltage requirements independently of the power supply), Resistive load or inductive load; see warning information hereafter for inductive load. The internal relay is designed for at least 100 000 cycles. Inductive load management requires a parallel diode for a better contact lifetime. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 32 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Example of connection for electrical door locks + VCC <30V Imax < 2A Overswing diode MorphoAccess® SIGMA Terminal Electric door lock Relay Pin 1 Relay Pin 2 Button on other side of the door Figure 12: Example of electric latch connection 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 33 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Tamper Switch Figure 13: Tamper switch wiring Light Blue Switch 1 Tamper switch contact Pink Switch 2 Strip on tamper switch Operating principle for the switch Product installed on the wall plate: switch enabled (contact closed). Product opened (rear connectors accessible): switch disabled (contact open). Nominal characteristics of switch block Electrical characteristics: 100 mA at 30 VDC max (Resistive load) according to the safety extra low voltage standard. This MorphoAccess® SIGMA Lite Series terminal is part of security system; it is customer’s responsibility to connect the tamper switch (contact) to physical access controller, in order to detect unauthorized access to the connector blocks. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 34 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wiegand port wiring Wiegand input wiring The following figure shows how to cable the wires of the “Wiegand In” port of the terminal for Wiegand protocol. This is used, for instance, to connect an external card stripe reader to the MorphoAccess® SIGMA Lite terminal. Figure 14: Wiegand input wiring 13 Green / Red WIEGAND_IN0 In Wiegand IN D0 (Output type required: Open drain or 5V+/-5%) 15 White / Red WIEGAND_IN1 In Wiegand IN D1 (Output type required: Open drain or 5V+/-5%) 11 Yellow GPO0 (WIEGAND_LEDIN) Out Wiegand LEDIN (typical = 5VDC) (option) 20 Black / Red WIEGAND_GND Ground for Wiegand If pull-up’s to 12V have been added on D0_IN and D1_IN inputs on a previous installation with a MorphoAccess® 500 Series terminal, these resistors must be removed to avoid any damage to the MorphoAccess® SIGMA Lite Series terminal. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 35 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wiegand output wiring The following figure shows how to cable the wires of the Wiegand OUT port of the terminal for Wiegand protocol. This is used, for instance, to connect the MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP). Figure 15: Wiegand output wiring 14 Green WIEGAND _OUT0 Out Wiegand OUT D0 (5V TTL) 16 White WIEGAND _OUT1 Out Wiegand OUT D1 (5V TTL) In Wiegand LED IN 1 (option): panel feedback (Output type required: Open drain or 5V+/-5%) In Wiegand LED IN 2 (option): panel feedback (Output type required: Open drain or 5V+/-5%) 17 Blue WIEGAND_LEDOUT1 18 Blue / Red WIEGAND_LEDOUT2 20 Black / Red WIEGAND_GND Ground for Wiegand The use of LED IN 1 and LED IN 2 wires is described in the paragraphs below. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 36 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface The controller supports neither LED1 nor LED2 signals When the access controller has no relay contact to provide an answer to the MorphoAccess® terminal, then the decision to emit either the “access granted” signal or the “access denied” signal is taken by another way. It is either the MorphoAccess® terminal itself that decide, or it waits for the access controller answer through the local area network (TCP), or on the RS-485 serial port. It is strongly recommended to disable the LED IN feature, to avoid any interference on MorphoAccess terminal behavior. The controller supports only LED1 signal When the access controller has only one relay contact which is dedicated to the “access granted” answer, this one must be connected between the LED1 and GND wires. The LED1 wire is set to the low level by closing the contact between the LED1 and the GND wires, and it means “access granted”. The MorphoAccess® terminal uses the timeout of the wait for a low level on the on LED1 wire or LED2 wire as “access denied” answer. To minimize at most the waiting time of the user, the MorphoAccess® SIGMA Lite Series terminal timeout value, must be adjusted to a value a little bit higher than the maximal value of the controller response time. Warning: if the LED2 wire is connected, it must be constantly maintained in the high state. The controller supports LED1 and LED2 signals When the controller supports one relay contact for each of the possible answers then: The « access granted » contact must be connected between the LED1 and the GND wires of the terminal The « access denied » contact must be connected between the LED2 and the GND wires of the terminal. The MorphoAccess® terminal considers that: The answer of the controller is "access granted", when the controller puts the LED1 wire to the low state (by closing a contact between the LED1 and the GND wires), and leaves the LED2 wire to the high state. The answer of the controller is "access denied", when the controller puts the LED2 wire to the low state (by closing a contact between the LED2 and the GND wires), whatever is the state of the LED1 wire. The MorphoAccess® terminal also considers that the answer of the controller is "access denied" in case of time-out while expecting for a closure between LED1 and GND wires, or between LED2 and GND wires. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 37 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Data Clock Input The following figure shows how to cable the wires of the “Wiegand In” port of the terminal for Data Clock protocol. This is used, for instance, to connect an external card stripe reader to the MorphoAccess® SIGMA Lite terminal. Figure 16: Wiegand port wiring – DataClock 13 Green / Red WIEGAND_IN0 In Data (Output type required: Open drain only) 15 White / Red WIEGAND_IN1 In Clock (Output type required: Open drain only) 17 Blue WIEGAND_LEDOUT1 Out Card present signal (if configured, only one selectable for Morpho Legacy) 18 Blue / Red WIEGAND_LEDOUT2 Out Card present signal (if configured) 20 Black / Red WIEGAND_GND 2015_2000007248-V1 - Draft June 2015 Ground for Wiegand This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 38 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Data Clock Output The following figure shows how to cable the wires of the Wiegand OUT port of the terminal for Data Clock protocol. This is used, for instance, to connect the MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP). Figure 17: Wiegand port wiring – Data Clock 17 Blue WIEGAND_LEDOUT1 Out Data ( 5V TTL ) 18 Blue / Red WIEGAND_LEDOUT2 Out Clock ( 5V TTL ) 20 Black / Red WIEGAND_GND 2015_2000007248-V1 - Draft June 2015 Ground for Wiegand This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 39 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface RS-485 port wiring The following figure shows how to cable the wires of the RS-485 OUT port of the terminal (RS-485 protocol). This is used, for instance, to connect the MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP). Figure 18: RS-485 port wiring – RS485 Blue RS485_A In/Out RS485 Rx/Tx non inverting signal Blue / Red RS485_B In/Out RS485 Rx/Tx inverting signal Black / Red RS485_GND Ground RS485 implementation is limited to half-duplex communication. So only Tx+, Tx- and ground reference signals are necessary. Depending on the RS485 network, an impedance adaptation may be required. For farthest terminal, a 120-Ohms resistor termination may be added outside the terminal between Tx+ and Tx-. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 40 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface GPIO wiring Figure 19: GPIO wiring Orange GPI_0 In Digital Input (1,8V to 5V) 10 Orange / Red GPI_1 In Digital Input (1,8V to 5 V) 11 Yellow GPO_0 Out Digital Output (5V – 5mA max) 12 Yellow / Red GPO_1 Out Digital Output (5V – 5mA max) Black / Red GPIO_GND 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 41 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Single Door Access Control (SDAC) implementation Push button / Motion sensor External Power supply RELAY_COM RELAY_NO/NC Door strike GPI_0 GPO_0 GPI_1 GPO_1 Door contact Figure 20: SDAC wiring If door contact is not used, GPI1 and GPO1 shall be connected together 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 42 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Ethernet connection Ethernet interface can be used to power the MorphoAccess® SIGMA Lite Series terminal through POE (Power Over Ethernet - IEEE802.3af or IEEE802.3at type 1 mode). According to the POE standard two modes are available: power on data pins and power on dedicated pins. Use either one of these modes depending on POE implementation on your local Ethernet network. Wi-Fi™ dongle must not be used with POE power supply. The POE doesn’t provide enough power for both the terminal and the Wi-Fi USB dongle. Ethernet cable shall be shielded Default Ethernet configuration By default, MorphoAccess® SIGMA Lite Series terminal is configured in DHCP mode Recommendations for RJ45 wiring Pin Signals Data pair Data pair Data pair NC/POE pin NC/POE pin dedicated (+) dedicated (+) Data pair 2 Ground/ pin dedicated (-) NC/POE pin dedicated (-) EIA / TIA T568B Colors White orange Orange White green Blue White blue Green White brown Brown EIA / TIA T568A Colors White green White green White green White green White green White green White green White green Corel L120 Colors Grey White Pink Orange Yellow Blue Purple Brown Figure 21: RJ45 wiring RJ45 plug pinout is compliant with 10/100 base T, IEEE802.3 Specification. Product is compliant also with MDI or MDI-X. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 43 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface External USB connection Figure 22: External USB connection The external Micro USB port can be used to connect a mass storage USB key for administration only. This requires a standard Micro USB-type A / USB-type A female adapter or cable (which can be found in Morpho catalogue with ref 293658551). Please report to MorphoAccess® SIGMA Lite Series Administration Guide for more information. USB connection is limited to USB mass storage key connection (power consumption shall not exceed 200mA) 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 44 MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wi-Fi™ dongle installation Wi-Fi™ dongle shall be preferably installed outside the product (separate area shall be reserved in the wall) and connected to the internal USB Mini B (at the rear of the terminal) using Morpho cable provided in the kit. Wi-Fi™ dongle shall not be exposed to temperature exceeding 50°C (don’t forget to count the thermal dissipation of the product and of the Wi-Fi™ dongle). Wi-Fi™ feature requires the product to be powered from an external DC 12V to 24V power supply (the POE doesn’t provides enough power for both the terminal and the Wi-Fi™ dongle) Only Wi-Fi™ dongle delivered by Morpho (kit reference XXX-TBD) may be installed with the terminal for WLAN (Wireless Local Area Network) operation. Cable has to be plugged on the upward USB connector of the rear panel, as on the following image: USB extension cord Wi-Fi™ USB dongle Figure 23: Wi-Fi™ dongle installation 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 45 MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Section 5 : User Interface 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 46 MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Modes for controlling access rights Introduction The MorphoAccess® SIGMA Lite Series terminal offers several methods for controlling access rights: it needs to be configured in one of the following four modes: Identification mode, Authentication mode (requires a contactless smartcard reader in the terminal), Multi-factor mode (requires a contactless smartcard reader in the terminal), Proxy mode Refer to MorphoAccess® SIGMA Lite Series Administration Guide for more information on Access Control. Identification mode The Identification process of the MorphoAccess® SIGMA Lite Series terminal proceeds by comparison of the biometric data of the finger placed on the biometric sensor, with all the biometric data stored in the database. It means that the biometric data of the allowed users must be stored in the internal database before they can request the access on the terminal. This biometric data is acquired either directly on the terminal (using the embedded webserver application and the biometric sensor of the terminal), or on an enrolment system using a biometric sensor compatible with the terminal (such as MorphoSmart™ sensors). The access control by identification process is started when a finger is detected on the biometric sensor When the user requests the access, his identity is unknown, and it is the terminal that searches for his identity. The terminal grants the access if a match is found (the user is identified); otherwise the access is denied (the user remains unknown). For further information, please see the "Identification mode" section in the MorphoAccess® SIGMA Lite Series Administration Guide. Authentication (verification) mode Unlike the "identification" mode, the user identity must be known in order to execute the authentication process. Indeed, authentication is an identity verification process: the user provides his identity and the terminal checks it with the relevant process. This mode doesn’t compare the user’s data to the data of several users: it compares the data provided by the user with the reference data provided by the same user during enrollment phase. The data can be on a card presented to the terminal or in a database and ID is provided by the user. Access is authorized if the terminal finds a correspondence. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 47 MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface For further information, please see the "Authentication mode" section in the MorphoAccess® SIGMA Lite Series Administration Guide. Multi-factor mode In this mode, the "identification" and "authentication" modes are available simultaneously; the user decides which control method will be used: by placing his finger on the sensor, thereby triggering the identification process, by placing his contactless card on the reader, thereby triggering the authentication process, This is the default mode for terminals fitted with a contactless smartcard reader. For further information, please see the "Multi-factors method" section in the MorphoAccess® SIGMA Lite Series Administration Guide. Proxy mode The Proxy mode is an operating mode where the access control main application is located in a distant system. This is not a standalone mode like Identification and Authentication modes. It means that the terminal becomes a slave of the host system application. The access control application is running on the host system and uses MorphoAccess® SIGMA Lite Series terminal high level functions: • Identification function • Authentication function • Read data on a contactless card • Access control result signal command The MorphoAccess® SIGMA Lite Series terminal is driven through an Ethernet (or WiFi™) link using TCP, SSL or TLS protocol. The MorphoAccess® SIGMA Lite Series terminal acts as a server: it is either waiting for a command or executing a command. The commands allowed by the MorphoAccess® SIGMA Lite Series terminal are described in the MorphoAccess® SIGMA Lite Series Host System Interface Specification document. For further details about SSL or TLS on the MorphoAccess® SIGMA Lite Series terminal, please refer to the MorphoAccess® SIGMA Lite Series Administration Guide. External database mode (also called polling mode) The reference biometric templates of the users are stored in external database, instead of terminal local database or user’s RF card. When authentication is initiated on the terminal, the terminal will poll the user ID to external controller. On polling out the ID, the corresponding template (if exists) is fetched from the external database and is authenticated against user’s biometric on 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 48 MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface the terminal. Once the template request is posted to the external database, the terminal shall wait for the finger template from the external database to start authentication. Further process shall be same as authentication. Polling Process using buffer: The user’s input ID will be queued in the terminal’s queue, which is polled by external application. External application waits for the User ID by polling the buffer. After getting an user ID, it will search the template in database and send template to terminal for further authentication. The user is authenticated by the external device and granted access accordingly. MorphoAccess® SIGMA Lite Series terminal also has distant commands to retrieve polling buffer status and polling buffer data. Refer to the MorphoAccess® SIGMA Lite Series Host System Interface Specification document. How to Activate? External database mode can be activated through Webserver > Complete Configuration, by setting “ucc.enable_external_database” parameter to 1. Only an admin user can activate polling mode. You can refer to the MorphoAccess® SIGMA Lite Series Host System Interface Specification document to know how to set this parameter. NOTA : When terminal is in L1 legacy mode, then polling mode can be configured using SecureAdmin application. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 49 MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Configuring the terminal MorphoAccess® SIGMA Lite Series terminals are standalone biometric systems which offers advance features for access control. MorphoAccess® SIGMA Lite Series terminals are equipped with a facility to support the MorphoAccess® and Bioscrypt legacy systems. When MorphoAccess® SIGMA Lite Series terminal is set in any of the legacy modes, it supports the database structures and configurations of the selected legacy system. When the terminal is booted for the first time, user can select any of the following modes: MorphoAccess® 500 or J Series legacy mode MorphoAccess® SIGMA Lite Series terminal can be operated in MorphoAccess® 500 or J series mode (also referred as Legacy Morpho). In this mode, the terminal will support configurations and operations of MorphoAccess® 500 series terminals. Terminal can authenticate users enrolled in the MorphoAccess® 500 series terminal, using biometric check as well as contactless card. New users can also be enrolled in MorphoAccess® 500 series mode. Once the product is configured in Legacy Morpho mode, the following methods can be used to configure the terminal: through the Ethernet interface (remote management) through a Wi-Fi™ connection (license and dongle required) Configuration procedures are described inside the MorphoAccess® SIGMA Lite Series Administration Guide as follows: Section 4: Terminal Configuration And Administration Bioscrypt 4G Series legacy mode MorphoAccess® SIGMA Lite Series can be operated in Bioscrypt 4G mode (also referred as Legacy L1). In this mode, the terminal will support limited operations and configurations that are done using Secure Admin application. The terminal in L1 mode is able to authenticate the users enrolled on 4G terminals and contactless cards. However it is not possible to enrol users in legacy L1 mode on MorphoAccess® SIGMA Lite Series terminal. In case, users are enrolled in MA5G mode, the user data cannot be exported when terminal is in L1 mode. Once the product is configured in Legacy L1 mode, the following methods can be used to configure the terminal: through the Ethernet interface (remote management) through a Wi-Fi™ connection (license and dongle required) 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 50 MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Configuration procedures are described inside the MorphoAccess® SIGMA Lite Series Administration Guide as follows: Section 4: Terminal Configuration And Administration MorphoAccess® SIGMA Lite Series native mode MorphoAccess® SIGMA Lite Series terminal is by default configured in native mode, also named MA5G. It will support the new features and configurations only in the native mode. The terminal can be configured using an internet browser connected to the embedded Webserver application. NOTA : When terminal mode is switched from MA5G to any of the legacy modes, the entire configuration (excepted communication links) and all databases are erased NOTA : The terminal is rebooted on mode change and factory settings are applicable. Once the product is configured in native mode, the following methods can be used to configure the terminal: through the Ethernet interface (remote management) through a Wi-Fi™ connection (license and dongle required) Configuration procedures are described inside the MorphoAccess® SIGMA Lite Series Administration Guide as follows: Section 4: Terminal Configuration And Administration 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 51 MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Anti-tamper / anti-pulling switches Please refer also to “Tamper Switch” section. These switches are activated as soon as there is enough pressure applied on the terminal against the wall. They are deactivated as soon as this pressure is not big enough, e.g. when the terminal is pulled out of the wall. When the switches are deactivated, the MorphoAccess® SIGMA Lite Series terminal acts as required by the related configuration key (see MorphoAccess® SIGMA Lite Series Administrator / User Guide for key configuration description): Ignore the event (default): useful during normal maintenance operations. Send an alarm message to the Central Access Controller, through the usual channel of the access control result messages (Wiegand, DataClock, RS485, Ethernet or Wi-Fi™). An alarm switch (relay contact) is directly available on block terminal «tamper switch pins». Please refer to “Wiring overview” and to “Tamper Switch” sections. Generate an audible alarm signal with the speaker and an alert message on the screen. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 52 MorphoAccess® SIGMA Lite Series – Installation Guide Section 6 : Accessories, Software Licenses and PC Applications Section 6 : Accessories, Software Licenses and PC Applications 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 53 MorphoAccess® SIGMA Lite Series – Installation Guide Section 6 : Accessories, Software Licenses and PC Applications Compatible Accessories, Licenses and Software The following items can be ordered directly to Morpho or to an official distributor, so as to enjoy all the features of your MorphoAccess® SIGMA Lite Series terminal: Power supply units, Contactless smartcards: MIFARE® 1k, 4k; DESFire® 2k, 4k, 8k, MA WI-FI PACK: containing a Wi-Fi™ USB dongle and a Wi-Fi™ license to activate Wi-Fi™ capability on your terminal, User database size license (MA_10K_USERS): enabling database size upgrade from 3,000 to 10,000 users capacity (max 3 fingers per record) at creation of the database. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 54 MorphoAccess® SIGMA Lite Series – Installation Guide Section 6 : Accessories, Software Licenses and PC Applications Compatible PC applications MorphoAccess® SIGMA Lite Series terminals are fully compatible with: Morpho Integrator’s Kit (MIK) software development kit (version 6 or later). MorphoBioToolBox (version 2 or later) Using Legacy Morpho mode, MorphoAccess® SIGMA Lite Series is also compatible with: MEMS (version 7.3.1 or later), MIK (version 5.4 or later), The limitations in Morpho Legacy mode are described in the following document: MorphoAccess® SIGMA Lite Series Release Note - Legacy Morpho limitations Using Legacy L1 mode, MorphoAccess® SIGMA Lite Series is also compatible with: SecureAdmin (version v4.1.20.0.0.0.0 or later), The limitations in L1 Legacy mode are described in the following document: MorphoAccess® SIGMA Lite Series Release Note - Legacy L1 limitations 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 55 MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations Section 7 : Recommendations 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 56 MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations Notice The manufacturer cannot be held responsible in case of non-compliance with the following recommendations or incorrect use of the terminal. General precautions Do not attempt to repair your terminal yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components. Any work carried out by non-authorized personnel will invalidate your warranty. Do not expose your terminal to extreme temperatures. Use your terminal with original accessories. Attempts to integrate unapproved accessories to the terminal will void your warranty. Due to electrostatic discharge, and depending on the environment, synthetic carpet should be avoided in areas where the terminal has been installed. Areas containing combustibles It is strongly recommended that you do not install your terminal in the vicinity of gas stations, petroleum processing facilities or any other facility containing flammable or combustible gasses or materials. Specific precautions for terminals equipped with a contactless smartcard reader It is recommended to install terminals equipped with a contactless smartcard reader at a certain distance (> 30cm) from metallic elements such as iron fixations or lift gates or radio product (such as contactless smartcard reader). Performances in terms of contactless badge reading distance will decrease when metallic elements are closer. Ethernet connection It is recommended to use a category 5 shielding cable (120 Ohms). It is also strongly recommended to insert a repeater unit every 90m. Extreme care must be taken while connecting Ethernet wire to the terminal block board since low quality connection may strongly impact Ethernet signal sensibility. It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do the same with Tx+/Tx- and the other twisted-pair wire). Date / Time synchronization The terminal clock has a +/-10 ppm typical time deviation at +25°C (roughly around +/- 6 sec per 48 hours). At lower and higher temperature (but within normal 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 57 MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations operating temperatures), deviation may be more important (worst case: - 14 seconds per 48 hours). If the terminal is used in an application requiring high time precision, we recommend synchronizing regularly your terminal time with an external clock (using NTP). Every 24 hours is usually enough for most applications. Please note that the date/time of the terminal is protected from power failure during at least 24 hours. If the duration of the power failure or power down is longer, the date/time of the terminal will be lost. Cleaning precautions The use of a dry cloth is recommended to clean the terminal, especially the biometric sensor. Acid liquids, alcohol or abrasive materials are prohibited. Legacy mode When terminal mode is switched from MA5G mode to any of the legacy modes, the entire configuration (except communication links) and all databases are erased. The terminal is rebooted on mode change and factory settings are applicable. Firmware legacy limitations are described in the MorphoAccess® SIGMA Lite Series Release Note. Hardware legacy differences are described below: Power supply 4G Lite Series MA-J Series MA SIGMA Lite Series 12V – 24V 12V 12V – 24V (-15% / +10%) (-15% / +30%) (-15% / +10%) DC power supply connection Wires Terminal block Wires Power supply by POE Only for CR Pass (IEEE802.3af compliant) IEEE802.3af compliant IEEE802.3at type 1 compliant POE power supply connection RJ45 connector or wires Block connector and RJ45 connector RJ45 connector or wires DC power supply 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 58 MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations Ethernet communication 4G Lite Series MA-J Series RJ45 connector or wires MA SIGMA Lite Series Block connector RJ45 connector RJ45 connector or wires Serial communications Wiegand 4G Lite Series MA-J Series MA SIGMA Lite Series Yes Interfaces multiplexed on the same lines. Yes Output ports Input ports No LED IN/OUT port Dataclock RS-485 No Half duplex (Slave only) Wiegand, Dataclock and RS-485 (Half duplex) protocols shall only be enabled at one time, else priority is given to Wiegand, then Dataclock, then RS485. Wiegand : Output port only + LED IN inputs Output port Input ports LED OUT port LED IN by GPO Yes Half duplex (Slave only) Dataclock: Output port GPI/GPO 4G Lite Series MA-J Series MA SIGMA Lite Series GPI 2 GPI No 2 GPI GPO 1 GPO GPO current limitation 2015_2000007248-V1 - Draft June 2015 (1 TTLOUT_H and 1 TTLOUT_L) No 5mA@5V for 4G 2GPO (≈ 2 TTLOUT_H only) 5mA@5V This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 59 MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations RELAY Relay pins available Driver capability 4G Lite Series MA-J Series MA SIGMA Lite Series NO / NC / COM* NO / COM NO / NC / COM 1 A @30V DC 1 A @30V DC 1 A @30V DC (Resistive load) (Resistive load) (Resistive load) *: NO: Normally open NC: Normally closed COM: Common RS232 communication 4G Lite Series MA-J Series MA SIGMA Lite Series Not available Not available Not available Anti theft/ Tamper switches 4G Lite Series MA-J Series MA SIGMA Lite Series Anti theft switch No Yes Yes Tamper switch Yes Yes Yes Warning to a host if the product isn’t supplied No Yes Yes 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 60 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Annex 1 : Finger Placement Recommendations 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 61 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Main principles Acquisition needs to be done with extreme care, in order to: get the best image quality increase recognition performance reduce recognition time Then, it is highly recommended to: Maximize the contact between the fingerprint and the sensor Exert firm, but not excessive, finger pressure on the surface of the sensor Do not press too hard Do not slide nor roll the finger across the sensor Do not move the finger during acquisition Wait for the extinction of sensor backlight before removing the finger 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 62 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Most useful areas for biometric data Fingerprint central area must be aligned with sensor center. Area containing the maximum information 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 63 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Position of finger Finger height Align center of 1st phalanx with sensor center Finger angle The finger must be parallel to sensor sides IDEAL POSITION 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 64 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Finger inclination Finger must be parallel to the sensor surface IDEAL POSITION Finger rotation Finger must be parallel to the sensor surface IDEAL POSITION 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 65 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Troubleshooting When finger biometric data recommendations listed below: acquisition is difficult, please follow the The finger is cold o Solution : warm up the finger The finger is wet o Solution : wipe the finger The finger is dry o Solution : warm up the finger and/or add a little bit of humidity The finger is dirty o Solution: wash hands Remove bandages or adhesive tapes from the fingerprint area, Do not press or tense finger to avoid blood vessels constriction 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 66 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography Annex 2 : 2015_2000007248-V1 - Draft June 2015 Bibliography This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 67 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography How to get the latest versions of documents The last version of the documents can be downloaded from our web site at the address below: www.biometric-terminals.com (Login and password required to allow access to the private part). To request a login, please contact your sales representative. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 68 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography Documents concerning the MorphoAccess® terminal Documents about installing the terminal MorphoAccess® SIGMA Lite Series Installation Guide, Ref. 2015_0000007248 This document describes terminal physical mounting procedure, electrical interfaces and connection procedures. This document is in English. Documents about administrating / using the terminal MorphoAccess® SIGMA Lite Series Quick User Guide, Ref. 2015_0000005700 This document gives a quick overview of the product and the basics of configuration and use. This document is in English. MorphoAccess® SIGMA Lite Series Administrator Guide, Ref. 2015_000000XXXX This document describes the different functions available on the terminal and procedures for configuring the terminal. It also contains the full description of all the configuration parameters for the terminal. This document is in English. MorphoAccess® SIGMA Lite Series Parameters Guide, Ref. 2015_000000XXXX This document contains the full description of all the terminal configuration parameters. This document is in English. Documents for the developer MorphoAccess® SIGMA Lite Series Host System Interface Specification, Ref. 2015_000000XXXX This document describes the commands supported by the MorphoAccess® terminal. This document is in English. MorphoAccess® SIGMA Lite Series Remote Message Specification, Ref. 2015_000000XXXX This document describes the format of messages sent by the terminal to a distant system. This document is in English. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 69 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography Release note For each firmware version, a release note is published describing the new features, the supported products, the potential known issues, the upgrade / downgrade limitations, the recommendations, the potential restrictions… 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 70 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 3 : Support Annex 3 : 2015_2000007248-V1 - Draft June 2015 Support This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 71 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 3 : Support Troubleshooting The terminal IP address is unknown or it is not possible to connect to the terminal Load a valid set of network parameters in your terminal. The sensor is switched off Check that the database contains at least one record. Check that the identification mode is enabled. The terminal returns erratic responses to Ping commands Check the subnet mask. Ask the network administrator for the correct value. Check that each device connected to the network has a different IP address. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 72 MorphoAccess® SIGMA Lite Series – Installation Guide Annex 3 : Support Technical Support and Hotline North America Mail: cscenter@morpho.com Tel: +1 888 940 7477 South America Mail: cscenter@morpho.com Tel: +1 714 575 2973 South Africa Mail: sec.san.bio.support@morpho.com Tel: + 27 11 286 5855 India: Mail: support.morphoindia@morpho.com Tel: 0120-4699900 Europe and rest of the world: Mail: hotline-biometrics@morpho.com Tel: +33 1 58 11 39 19 (9H00am to 5H30pm French Time, Monday to Friday) Web site For the latest firmware, software, document releases, and news, please check our website: www.biometric-terminals.com To get your log in and password please contact your sales representative. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho. They must not be copied or communicated to a third party without the prior written authorization of Morpho 73 COPYRIGHT© 2015 Morpho Registered office: Morpho 11, boulevard Gallieni 92130 Issy-les-Moulineaux – France www.morpho.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 74 Language : fr-FR Title : MorphoAccess® SIGMA Lite Series - Installation Guide Author : ROGER Luc (MORPHO) Creator : Microsoft® Word 2010 Create Date : 2015:07:30 14:15:04+02:00 Modify Date : 2015:07:30 14:15:04+02:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools