SALUS North America AKL08RF ZigBee Zone Wiring Center User Manual part 1

SALUS North America, Inc. ZigBee Zone Wiring Center part 1

Contents

User manual part 1

Download: SALUS North America AKL08RF ZigBee Zone Wiring Center User Manual part 1
Mirror Download [FCC.gov]SALUS North America AKL08RF ZigBee Zone Wiring Center User Manual part 1
Document ID3260292
Application ID3lo5NqDHj+id5gh0sVC/gQ==
Document DescriptionUser manual part 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize221.27kB (2765874 bits)
Date Submitted2017-01-16 00:00:00
Date Available2017-01-16 00:00:00
Creation Date2017-01-16 17:55:43
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-01-16 17:55:43
Document TitleUser manual part 1
Document CreatorAdobe InDesign CC 2017 (Macintosh)

silk print white
Transparent matt gray(same color and
surface finishing with old KL08 cover)
AKL08RF Zigbee Zone Wiring Center
Installation and Wiring Guide
Group 1 thermostats
AS20RF
AS20RF
AS20RF
Group 2 thermostats
AS20RF
AS20RF
Stand alone thermostats
AS20RF
AS20RF
AS20RF
gloss white(same color and
finishing with old KL08)
matt surface finishing, s
color with old KL08 bod
Remove the white plate in order to reach the
power cord terminals for 120VAC supply.
L N PG
G1
Remove the High Voltage
cover access to the Boiler
and Pump terminals.
G2
L N PG
Heat/ Cool changeover
(Open = heat, closed = cool)
Loosen the wire connectors and insert
wires for the power, boiler and pump.
Install wires in their respective locations.
Tighten the wire connectors to secure the
wires. See section 8 for more info.
Dew point sensor
24
VAC
11
4 Amp
DRY CONTACTS
ONLY
INFORMATION
INFORMATION
Electrical connections
Live connection
Hot
Neutral
PG
Fuse
Ground
4 Amp
G1
Group 1 Thermostats
G2
Group 2 Thermostats
CO
Change Over (Heat/Cool)
These instructions apply to the SALUS
model stated above.
13
120VAC TO UFH PUMP
Cables will be supplied
by the installer
L N PG
Warning
This product must be fitted by a competent person,
and installation must comply with the guidance,
standards and regulations applicable to the country
or state where the product is installed. Failure
to comply with the requirements of the relevant
guidance, standards and regulations could lead to
injury, death or prosecution.
Warning
Always isolate the AC main supply before installing
or working on any components that require 120 V
AC 60Hz supply.
The ground terminals on the AKL08RF are for ground
connections only. These terminals provide no earth
protection.
Optional boiler
Connection
UNDERFLOOR HEATING
MANIFOLD
For PDF Installation guide go to www.salusna.com
SALUS Project:
AKL08 - RF Wiring Center
(SW0012 / Rev 10)
N PG L
External Power Supply
www.salusna.com Technical Helpline 1-650-360-1725
The wire connectors used for
securing the wires are sold
separately.
If you are mounting the Zone Wiring
Center on a stud wall, extra support
may be required.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of
the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence.
L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2)
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm
from all persons.
Les antennes utilisées pour cet émetteur doivent être installées pour fournir une distance de séparation au
moins de 20 cm de toutes les personnes.
Maintaining a policy of continued product development SALUS Controls plc reserves the right to change
specification, design and materials of products listed on this installation guide without prior notice.
Issue Date: Dec 2016
logo&
gloss

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Modify Date                     : 2017:01:16 17:55:43+08:00
Create Date                     : 2017:01:16 17:55:43+08:00
Metadata Date                   : 2017:01:16 17:55:43+08:00
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Format                          : application/pdf
Document ID                     : uuid:62a9a038-1362-4700-a238-745e3cac0e19
Instance ID                     : uuid:e5f27f7a-c5d5-4092-9481-fce56e843bca
Producer                        : Adobe PDF Library 15.0
Page Count                      : 1
Creator                         : Adobe InDesign CC 2017 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AG86-AKL08RF

Navigation menu