!"#$%&'()((*'$+,--,+%&'./0%12(3+,#+(40%5"6(7"89"#,+0#"(3"'$&#(:33;<;=>?(Visit www.salusinc.com for the User Manual In#the#Box#####Tools#Needed##Note:#((((( (@55%+%&',-( "A0%98"'+( 8,B( C"( #"A0%#"5(50"(+&(C0%-5%'D(1&'$+#01+%&'(&#(8,+"#%,-$E(&#( &+F"#( #,5%&( %'+"#G"#"'1"( +F,+( 8,B(#"501"(+F"(#,5%&(#,'D"H(3"'$&#(I.(J,--(K-,+"(,'5(>,++"#B(:LM(NO)E(P!(Q%+F%08?((3+,'5(R&0'+%'D(S%+(*'$+,--,+%&'.(/0%12T$+,#+(40%5"((UL(KF%--%9$(31#"I5#%V"#((((((((((PAIRING#INSTRUCTIONS#• Follow your system’s instructions to prepare to add devices to the system. • Remove the face plate from the Sensor and pull the battery tab to start the pairing process. • When the Sensor is detected and added to the system, proceed to the Sensor installation. WALL#INSTALLATION#INSTRUCTION#• Identify the location for the Wall Plate, orienting the metal plate of the Sensor Wall Plate at the bottom if installing vertically. Horizontal installation is also supported. For best readings, the Sensor should be in an open area, away from the direct air flow of HVAC vents. • Position the Wall Plate at the desired location and screw into position using the screws provided.  • Place the Sensor over the latch and slide into position on the wall plate. #DESK/COUNTERTOP#PLACEMENT#• For desk or countertop placement, simply place the Sensor over the latch in the Stand and slide down into position. ((((LED#INDICATIONS#Solid at power up: Initializing, checking for Factory Reset 3 flashes then pause: Searching for network to join (REPLACING#THE#BATTERY#:W$"(&'-B(X0#,1"--(XQTNO)E(O,B&V,1(OQTNO)E(Y'"#D%Z"#(YQLNO)E(&#(4K(>,++"#%"$(4KNO)(C,++"#%"$? • Grasp the top of the Sensor face plate and lift it from the Sensor body.  • Press a finger on the positive end of the battery and lift to remove the battery from the Sensor. • Insert a new battery into the Sensor, observing the proper polarity.  • Position the Sensor face plate over the Sensor body and snap the face plate onto the body.  FACTORY#RESETTING#THE#SENSOR#• Remove the Sensor face plate from the Sensor body. • Remove the battery. • Press and hold the side button while re-inserting the battery. • Release the side button when the LED lights on the front of the Sensor. The Sensor is reset to factory defaults and will respond to pairing requests. • After pairing, position the Sensor over the Mounting Plate and snap the Sensor onto the Mounting Plate. (
!"#$%&'()(SPECIFICATIONSOperating Conditions 32–104°F / 0–40°C 10–90% humidity    (non-condensing) Storage -4–185 °F / -20–85°C 20–95% humidity    (non-condensing) Protocols Supported ZigBee 3.0 RF Freq. 2.4 GHz Battery 3V Lithium CR2 Size Sensor w/ Wall Plate: 2.91” x 0.98” x 0.79” /  74mm x 25mm x 20mm Sensor w/ Stand: 3.03” x 1.65” x 1.10” /  77mm x 42mm x 28mm FCC#STATEMENTS#WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any  interference  received,  including  interference  that  may cause undesired operation.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a residential  installation.  This  equipment  generates,  uses  and can  radiate  radio frequency  energy,  and  if  not  installed  and used in accordance with the instructions, may  cause harmful interference  to  radio  communications.  However,  there  is  no guarantee  that  interference  will  not  occur  in  a  particular installation. If this equipment does cause harmful interference to radio or television reception, which  can be  determined  by turning the equipment off and on, the user is encouraged to try to  correct  the  interference  by  one  or  more  of  the  following measures:•Reorient or relocate the receiving antenna.•Increase  the  separation  between  the  equipment  andreceiver.•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•Consult the dealer or an experienced radio/TV technicianfor help.FCC#AND#INDUSTRY#CANADA#RF Radiation Exposure statement: This equipment complies with FCC and Industry Canada RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be  installed  and  operated  with  a  minimum  distance  of  20 centimeters between the antenna and all persons. INDUSTRY#CANADA#This device complies with Industry Canada licence-exempt RSS standard(s).  Operation  is  subject  to  the  following  two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables  aux  appareils  radio  exempts  de  licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même  si  le  brouillage  est  susceptible  d'en  compromettre  le fonctionnement. SALUS#WARRANTY#SALUS North America, Inc. (“Salus”) warrants that for a period of five (5) years  (“Warranty  Period”)  from  the  date  of  purchase  by  the  consumer (“Customer”), this device, excluding batteries (“Product”), shall be free of defects in materials and workmanship under normal use and service in accordance  with  all  supplied  instructions.  During  the  warranty  period, Salus shall, at its option, repair or replace any defective Products, at no charge  for  the  device.  Any  replacement  and/or  repaired  devices  are warranted for the remainder of  the original Warranty Period or ninety (90) days, whichever is longer. This  warranty  does  not  cover  removal  or  reinstallation  costs.  This warranty  does  not  apply  to  any  Product  (i)  which  has  been  modified, repaired,  or  altered,  except  by  Salus  or  an  authorized  Salus representative, (ii) which has not been maintained in accordance with any handling  or  operating instructions  supplied  by  Salus,  or  (iii) which has been subjected to unusual physical or electrical stress, misuses, abuse, negligence or accidents. This warranty is the only express warranty Salus makes for the Product. Any implied warranties, including warranties of merchantability or fitness for  a  particular  purpose,  are  limited  to  the  Warranty  Period  or  the shortest period allowed by law.  SALUS SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY  SPECIAL,  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES RESULTING,  DIRECTLY  OR  INDIRECTLY,  FROM  ANY  BREACH  OF  ANY WARRANTY,  EXPRESS  OR  IMPLIED,  OR  ANY  OTHER  FAILURE  OF  THIS PRODUCT.  Some  states  and  provinces  do  not  allow  the  exclusion  or limitation  of  incidental  or  consequential  damages,  or  limitation  on  the duration  of  implied  warranties  of  merchantability  or  fitness,  so  these exclusions or limitations may not apply to you. No  oral  or  written  information  or  advice  given  by  Salus  or  a  Salus-authorized  representative  shall  modify  or  extend  this  warranty.  If  any term is held to be illegal or unenforceable, the legality or enforceability of the remaining terms shall not be affected or impaired. Customer’s  sole  and  exclusive  remedy  under  this  limited  warranty  is product  repair  or  replacement  as  provided  herein.  If  a  Product  under warranty is defective, the Customer may: •contact the party (“Seller”) from which the Customer purchased theProduct  to  obtain  an  equivalent  replacement  product  after  theSeller  has  determined  that  the  Product  is  defective  and  theCustomer is eligible for a replacement, or•contact  Salus  Service  at  support@salusinc.com,  to  determinewhether the device qualifies for a replacement. If a replacement iswarranted and is shipped prior to  the return of the  device  underwarranty, a credit card is required and a hold may be placed on theCustomer’s  credit card  for  the  value  of  the  replacement  until  thereturned device is verified as eligible for replacement, in which case,the Customer’s credit card will not be charged.This warranty gives you specific legal rights, and you may also have other rights that vary from jurisdiction to jurisdiction. If you have any questions regarding this warranty, please write Salus at: SALUS North America, Inc. 850 Main Street  Redwood City, CA  94063 The distance between user and products should be no less than 20cmla distance entre l'utilisateur et les produits devraient être au moins 20 cm

Navigation menu