SEIKAKU TECHNICAL GROUP UPUR-8DR-81DR Wireless Mircophone Receiver User Manual UR 81DR
SEIKAKU TECHNICAL GROUP LIMITED Wireless Mircophone Receiver UR 81DR
Contents
- 1. User Manual I
- 2. User Manual II
- 3. User Manual III
User Manual III
NF02500-1.0 All rights reserved to SEIKAKU. All features and content might be changed without prior notice. Any photocopy, translation, or reproduction of part of this manual without written permission is forbidden. Copyright c 2006 SEIKAKU GROUP No.1, Lane 17, Sec. 2, Han Shi West Road, Taichung, 401 TAIWAN Tel:886-4-22313737 Fax:886-4-22346757 http://www.show-pa.com e-mail: sekaku@sekaku.com UR-81DR UP-8H/8P SERIES All rights reserved to SHOW. All features and content might be changed without prior notice. Any photocopy, translation, or reproduction of part of this manual without written permission is forbidden. Please read this manual carefully before operating this unit for the first time. IMPORTANT! Unplug this apparatus during lightning storms or when unused for long periods of time. Power Supply Ensure the source voltage matches the voltage of the power supply before turning ON the apparatus. WARNING CAUTION: Describes precautions that should be observed to prevent danger of the apparatus. Disposing of this product should not be placed in municipal waste and should be separate collection. OFF: Denotes the apparatus turns off, because of using the single pole switch, be sure to unplug the AC power to prevent any electric shock before you proceed your service. WARNING: Describes precautions that should be observed to prevent the danger of injury or death to the user. ON: Denotes the apparatus turns on. Hazardous live terminal . Alternating current /voltage. Protective grounding terminal. The symbol is used in the service documentation to indicate that specific component shall be only replaced by the component specified in that documentation for safety reasons. The symbol is used to indicate that some hazardous live terminals are involved within this apparatus, even under the normal operating conditions. RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION SAFETY RELATED SYMBOLS Do not use this apparatus near water. Install in accordance with the manufacturer's Operating Conditions This apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on this apparatus. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Never cut off the internal or external protective grounding wire or disconnect the wiring of protective grounding terminal. Make sure to connect the protective grounding to prevent any electric shock before turning ON the apparatus. Protective Grounding Fuse To prevent a fire, make sure to use fuses with specified standard (current, voltage, type). Do not use a different fuse or short circuit the fuse holder. Before replacing the fuse, turn OFF the apparatus and disconnected the power source. The cover should be removed by the qualified personnel only. No user serviceable parts inside. There are maybe some areas with high voltages inside, to reduce the risk of electric shock, do not remove any cover if the power supply is connected. Do not Remove any Cover External Connection The external wiring connected to the output hazardous live terminals requires installation by an instructed person, or the use of ready-made leads or cords. Don't use solvents such as benzol, alcohol, or other fluids with very strong volatility and flammability for cleaning the apparatus body. Clean only with dry cloth. When the apparatus needs a cleaning, you can blow off dust from the apparatus with a blower or clean with rag etc. Cleaning Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Do not defeat the safety purpose of the polarized or grounding type plug. Power Cord and Plug Follow all instructions. Keep these instructions. Heed all warnings. Only use attachments/accessories specified by the manufacturer. Read these instructions. IMPORTANT SAFETY INSTRUCTIONS instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not block any ventilation openings. No naked flame sources, such as lighted candles, should be placed on the apparatus. WARNING: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Servicing Refer all servicing to qualified personnel. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so . Servicing is required when the apparatus has been damaged in any way ,such as power supply cord or plug is damaged , liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Group 2-1: 798.325 Group 2-5: 807.925 Group 5-1: 798.925 Group 7-1: 799.325 Group 12-2: 802.725 20 12 876.525 876.725 876.925 877.125 877.325 877.525 877.725 877.925 878.125 878.325 878.525 878.725 11 874.125 874.325 874.525 874.725 874.925 875.125 875.325 875.525 875.725 875.925 876.125 876.325 10 871.725 871.925 872.125 872.325 872.525 872.725 872.925 873.125 873.325 873.525 873.725 873.925 9 869.325 869.525 869.725 869.925 870.125 870.325 870.525 870.725 870.925 871.125 871.325 871.525 8 866.925 867.125 867.325 867.525 867.725 867.925 868.125 868.325 868.525 868.725 868.925 869.125 7 864.525 864.725 864.925 865.125 865.325 865.525 865.725 865.925 866.125 866.325 866.525 866.725 6 862.125 862.325 862.525 862.725 862.925 863.125 863.325 863.525 863.725 863.925 864.125 864.325 5 859.725 859.925 860.125 860.325 860.525 860.725 860.925 861.125 861.325 861.525 861.725 861.925 4 857.325 857.525 857.725 857.925 858.125 858.325 858.525 858.725 858.925 859.125 859.325 859.525 3 854.925 855.125 855.325 855.525 855.725 855.925 856.125 856.325 856.525 856.725 856.925 857.125 2 852.525 852.725 852.925 853.125 853.325 853.525 853.725 853.925 854.125 854.325 854.525 854.725 1 850.125 850.325 850.525 850.725 850.925 851.125 851.325 851.525 851.725 851.925 852.125 852.325 Group1 Group2 Group3 Group4 Group5 Group6 Group7 Group8 Group9 Group10 Group11 Group12 F8: 850.000-874.000(850-879)MHz Group 1-1: 798.125 Group 2-2: 800.725 Group 3-4: 805.725 Group 5-8: 815.725 Group 8-6: 811.525 Remark: 1. The values with underlines should be scanned manually by adjusting UP/DOWN key. 2. The following channels can be used simultaneously without any interference. 19 12 824.525 824.725 824.925 825.125 825.325 825.525 825.725 825.925 826.125 826.325 826.525 826.725 11 822.125 822.325 822.525 822.725 822.925 823.125 823.325 823.525 823.725 823.925 824.125 824.325 10 819.725 819.925 820.125 820.325 820.525 820.725 820.925 821.125 821.325 821.525 821.725 821.925 9 817.325 817.525 817.725 817.925 818.125 818.325 818.525 818.725 818.925 819.125 819.325 819.525 8 814.925 815.125 815.325 815.525 815.725 815.925 816.125 816.325 816.525 816.725 816.925 817.125 7 812.525 812.725 812.925 813.125 813.325 813.525 813.725 813.925 814.125 814.325 814.525 814.725 6 810.125 810.325 810.525 810.725 810.925 811.125 811.325 811.525 811.725 811.925 812.125 812.325 5 807.725 807.925 808.125 808.325 808.525 808.725 808.925 809.125 809.325 809.525 809.725 809.925 4 805.325 805.525 805.725 805.925 806.125 806.325 806.525 806.725 806.925 807.125 807.325 807.525 3 802.925 803.125 803.325 803.525 803.725 803.925 804.125 804.325 804.525 804.725 804.925 805.125 2 800.525 800.725 800.925 801.125 801.325 801.525 801.725 801.925 802.125 802.325 802.525 802.725 1 798.125 798.325 798.525 798.725 798.925 799.125 799.325 799.525 799.725 799.925 800.125 800.325 Group1 Group2 Group3 Group4 Group5 Group6 Group7 Group8 Group9 Group10 Group11 Group12 F7: 798.000-822.000(798-827)MHz 12 766.525 766.725 766.925 767.125 767.325 767.525 767.725 767.925 768.125 768.325 768.525 768.725 11 764.125 764.325 764.525 764.725 764.925 765.125 765.325 765.525 765.725 765.925 766.125 766.325 10 761.725 761.925 762.125 762.325 762.525 762.725 762.925 763.125 763.325 763.525 763.725 763.925 9 759.325 759.525 759.725 759.925 760.125 760.325 760.525 760.725 760.925 761.125 761.325 761.525 8 756.925 757.125 757.325 757.525 757.725 757.925 758.125 758.325 758.525 758.725 758.925 759.125 7 754.525 754.725 754.925 755.125 755.325 755.525 755.725 755.925 756.125 756.325 756.525 756.725 6 752.125 752.325 752.525 752.725 752.925 753.125 753.325 753.525 753.725 753.925 754.125 754.325 5 749.725 749.925 750.125 750.325 750.525 750.725 750.925 751.125 751.325 751.525 751.725 751.925 4 747.325 747.525 747.725 747.925 748.125 748.325 748.525 748.725 748.925 749.125 749.325 749.525 3 744.925 745.125 745.325 745.525 745.725 745.925 746.125 746.325 746.525 746.725 746.925 747.125 2 742.525 742.725 742.925 743.125 743.325 743.525 743.725 743.925 744.125 744.325 744.525 744.725 1 740.125 740.325 740.525 740.725 740.925 741.125 741.325 741.525 741.725 741.925 742.125 742.325 Group1 Group2 Group3 Group4 Group5 Group6 Group7 Group8 Group9 Group10 Group11 Group12 F6: 740.000-764.000(740-769)MHz 6. ANNEX...................................................................................................16 5. TECHNICAL SPECIFICATIONS............................................................14 4. OPERATION............................................................................................9 3. CONTROL ELEMENTS...........................................................................5 2. FEATURES..............................................................................................5 1. INTRODUCTION......................................................................................1 TABLE OF CONTENTS Dynamic(S-100) Dynamic(S-600) Dynamic(S-500) Condenser(C-100) Condenser(C-200) Model No. UP-81H UP-83H UP-86H UP-87CH UP-88CH Capsule UP-8H series Handheld Transmitter To well satisfy the different applications , there are 5 models in total are included in this product range, please make sure that the proper microphone has been selected for your typical sound reinforcement system before installation. UP-8H, Handheld transmitter UR-81DR, PLL UHF Diversity Receiver Generally, the UR-81DR and UP-8H/8P series consists of -UR-81DR, PLL UHF Diversity Receiver -UP-8H, Handheld transmitter -UP-8P series, Body Pack transmitter By the Auto Scan function provided by the UR-81DR, PLL UHF Diversity Receiver, the operating frequency of the transmitter may be automatically searched out and locked by the system. Or, you can manually adjust the channel of the transmitter to match the receiver in case you know about the operating frequency of it. Thanks for purchasing the SHOW wireless microphone system. The UR-81DR and UP-8H/8Pseries is the delicately designed UHF, PLL synthesized system, with two antennas builtinside the receiver for smart switching diversity control, the higher level RF signals Maybe fed into the system for greater reliability and coverage, therefore, the risks of Breakdown and interference are to be effectively reduced. 1. INTRODUCTION 639.525 640.725 641.925 643.125 644.325 645.525 646.725 647.925 649.125 650.325 651.525 638.125 639.325 640.525 641.725 642.925 644.125 645.325 646.525 9 647.725 10 648.925 11 650.125 12 651.325 650.525 651.725 648.125 649.325 646.925 645.725 642.125 643.325 644.525 639.725 640.925 638.525 Group3 650.725 651.925 648.325 649.525 647.125 645.925 642.325 643.525 644.725 639.925 641.125 638.725 Group4 650.925 652.125 648.525 649.725 647.325 646.125 642.525 643.725 644.925 640.125 641.325 638.925 Group5 651.125 652.325 648.725 649.925 647.525 646.325 642.725 643.925 645.125 640.325 641.525 Group6 639.125 18 12 728.525 728.725 728.925 729.125 729.325 729.525 729.725 729.925 730.125 730.325 730.525 730.725 11 726.125 726.325 726.525 726.725 726.925 727.125 727.325 727.525 727.725 727.925 728.125 728.325 10 723.725 723.925 724.125 724.325 724.525 724.725 724.925 725.125 725.325 725.525 725.725 725.925 9 721.325 721.525 721.725 721.925 722.125 722.325 722.525 722.725 722.925 723.125 723.325 723.525 8 718.925 719.125 719.325 719.525 719.725 719.925 720.125 720.325 720.525 720.725 720.925 721.125 7 716.525 716.725 716.925 717.125 717.325 717.525 717.725 717.925 718.125 718.325 718.525 718.725 6 714.125 714.325 714.525 714.725 714.925 715.125 715.325 715.525 715.725 715.925 716.125 716.325 5 711.725 711.925 712.125 712.325 712.525 712.725 712.925 713.125 713.325 713.525 713.725 713.925 4 709.325 709.525 709.725 709.925 710.125 710.325 710.525 710.725 710.925 711.125 711.325 711.525 3 706.925 707.125 707.325 707.525 707.725 707.925 708.125 708.325 708.525 708.725 708.925 709.125 2 704.525 704.725 704.925 705.125 705.325 705.525 705.725 705.925 706.125 706.325 706.525 706.725 1 702.125 702.325 702.525 702.725 702.925 703.125 703.325 703.525 703.725 703.925 704.125 704.325 Group1 Group2 Group3 Group4 Group5 Group6 Group7 Group8 Group9 Group10 Group11 Group12 F5: 702.000-726.000(702-731)MHz Group2 638.325 Group1 F4: 638.000-662.000(638-664)MHz 518.325 519.525 520.725 521.925 525.525 526.725 527.925 529.125 530.325 531.525 518.125 519.325 520.525 521.725 522.925 524.125 525.325 526.525 527.725 10 528.925 11 530.125 12 531.325 529.325 530.525 531.725 525.725 526.925 528.125 523.325 524.525 519.725 520.925 522.125 518.525 Group3 579.725 580.925 582.125 578.325 579.525 580.725 581.925 583.125 584.325 585.525 578.125 579.325 580.525 581.725 10 582.925 11 584.125 12 585.325 17 583.325 584.525 585.725 578.525 572.525 573.725 574.925 576.125 577.325 572.325 573.525 574.725 575.925 577.125 572.125 573.325 574.525 575.725 576.925 Group3 Group2 Group1 F3: 572.000-596.000(572-598)MHz 523.125 524.325 Group2 Group1 F2: 518.000-542.000(518-544)MHz 583.525 584.725 585.925 582.325 579.925 581.125 578.725 572.725 573.925 575.125 576.325 577.525 Group4 529.525 530.725 531.925 525.925 527.125 528.325 523.525 524.725 519.925 521.125 522.325 518.725 Group4 583.725 584.925 586.125 582.525 580.125 581.325 578.925 572.925 574.125 575.325 576.525 577.725 Group5 529.725 530.925 532.125 526.125 527.325 528.525 523.725 524.925 520.125 521.325 522.525 518.925 Group5 583.925 585.125 586.325 582.725 580.325 581.525 579.125 Group6 573.125 574.325 575.525 576.725 577.925 529.925 531.125 532.325 526.325 527.525 528.725 523.925 525.125 520.325 521.525 522.725 Group6 519.125 S-600 Type: Dynamic Mic. Frequency response: 50Hz~16kHz( 3dB) Impedance: 300 20% at 1kHz Sensitivity: -71dB 3dB Direction: Omni-directional S-100 Type: Dynamic Mic. Frequency response: 50Hz~15kHz( 3dB) Impedance: 270 20% at 1kHz Sensitivity: 0.005% Direction: Omni-directional Generally, each model is equipped with the typical type of capsule for specific sound characteristic, and the RF design keeps the same, please refer to the following specification of the capsules for more information on the microphone selection to your system. C-100 Type: Condenser Mic. Frequency response: 50Hz~15kHz( 3dB) Impedance: 270 20% at 1kHz Sensitivity: -71dB 3dB Direction: Omni-directional S-500 Type: Dynamic Mic. Frequency response: 90Hz~12kHz( 3dB) Impedance: 680 20% at 1kHz Sensitivity: -52dB 3dB Direction: Uni-directional Group2 470.325 471.525 472.725 473.925 475.125 476.325 477.525 478.725 479.925 481.125 482.325 483.525 Group1 470.125 471.325 472.525 473.725 474.925 476.125 477.325 478.525 479.725 480.925 482.125 483.325 10 11 12 16 483.725 481.325 482.525 477.725 478.925 480.125 475.325 476.525 472.925 474.125 470.525 471.725 Group3 F1: 470.000-494.000(470-496)MHz 6.2 Frequency Ranges F1:470.000-494.000(470-496)MHz F3:572.000-596.000(572-598)MHz F5:702.000-726.000(702-731)MHz F7:798.000-822.000(798-827)MHz 483.925 481.525 482.725 477.925 479.125 480.325 475.525 476.725 473.125 474.325 470.725 471.925 Group4 484.125 481.725 482.925 478.125 479.325 480.525 475.725 476.925 473.325 474.525 470.925 472.125 Group5 484.325 481.925 483.125 478.325 479.525 480.725 475.925 477.125 473.525 474.725 Group6 471.125 472.325 F2:518.000-542.000(518-544)MHz F4:638.000-662.000(638-664)MHz F6:740.000-764.000(740-769)MHz F8:850.000-874.000(850-879)MHz Most countries closely regulate the radio frequencies used in the transmission of wireless information. These regulations state which devices can use which frequencies, and help to limit the amount of RF(radio frequency)interference in all wireless communications.To be flexible enough to operate worldwide, UR-81DR Wireless receivers are available in a number of models, each with a unique frequency range. Each frequency range, or band, spans up to 24MHz of the wireless broadcast spectrum. Available bands are: 6.1 Frequency Band Selection 6. ANNEX ) 35KHz Max. Deviation Weight Dimensions Mic. Capsule(optional) Optional 0.246Kg 15 0.009Kg Condenser or Dynamic Capsule Condenser or Dynamic Capsule 277 36.5mm (10.9" 1.44") 97mm 68mm 22mm(3.82" 2.68" 0.87") "AA" type 2 Nickel hydrogen battery +charger 100mA Current drain Battery 30-33 KHz Tone frequency Dynamic 100dB FM (F3E) 5-50mW(adjustable 3 bands) ~ 50 1KHz<0.8% 0.005% (-10 Modulation mode RF output power UP-8P Dependent on applicable country regulations 50 Hz-15KHz ( 3dB) T.H.D. Frequency stability Frequency response MODEL UP-8H SPECIFICATION Oscillation mode PLL UHF SYNTHESIZED Carrier frequency band UHF 470-900 MHz HM-38, Condenser microphone Preset impedance: 600ohm; Freq. response: 80-12KHz; Sensitivity: -68dB+/-3dB at 1KHz; Directional: Uni-directional; Weight: 52g (0.12Ib) HM-58, Condenser microphone Preset impedance: 700ohm; Freq. response: 200-8KHz; Sensitivity: -65dB at 1KHz; Directional: Uni-directional; Weight: 54g (0.12Ib) For the UP-8P series, there are several types of clip microphone are included in this product range, please make sure that the proper microphone has been selected for your typical sound reinforcement system before installation. UP-8P series, Body Pack transmitter C-200 Type: Condenser Mic. Frequency response: 100Hz~15kHz( 3dB) Impedance: 700 30% at 1kHz Sensitivity: -44dB 3dB Direction: Uni-directional 3 1 Power Switch It switches on/off UR-81DR main power. THE FRONT PANEL 3.1 UR-81DR, PLL UHF Diversity Receiver 3. CONTROL ELEMENTS -Common features, -PLL synthesized design; -Consistent operating frequencies to comply with the EMC regulations; -Up to 12x12, total 144 channel frequency presets; -Manufactured under ISO9000:2000, ISO/TS16949:2002 quality management system; -Soft touch painting for comfortable use; -Rechargeable battery design; -Three RF output power versions; -Mute function; -Lock function to avoid the misaction during the live applications; -UP-8H/8P transmitters, -Friendly interface of front panel LCD status display; -Auto Scan function for easy and convenient operation; -Switching diversity control to receive the RF signal; -Three output level versions; -Squelch control; -UR-81DR, PLL UHF Diversity Receiver, 2. FEATURES Last but not the least, the operating frequency of this wireless system may be varied from 470MHz to 900MHz, please refer to your national EMC regulations to pick out the authorized frequency band (F1 ~ F8, detail please see Annex hereafter) for your end application. Receiver type Weight Dimensions Balance output Power supply Audio output 14 1.042Kg 210(W) 165 (D) 50(H)mm; (8.3" 6.5" 1.9) DC 12V/ 500mA (AC 115V/230V 50/60Hz adaptor) 1V , 35KHz deviation 35KHz deviation Unbalanced 6.3mm phone jack 750mV ; 100dB -100 dBm/30dB SINAD -50 Dynamic RF sensitivity T.H.D. Modulation mode S/N Ratio 0.005% (-10 PLL UHF SYNTHESIZED 50 Hz-15KHz ( 3dB) 1KHZ 0.8% FM (F3E) 90dB Frequency stability Frequency response UHF 470-900 MHz Dependent on applicable country regulations Multi-channels, up to 144 frequency presets for each frequency bands Channel Frequency band UR-81DR MODEL 5. TECHNICAL SPECIFICATIONS 1) Check the preset frequency (preset group, and preset channel) displayed on the receiver in MHz. 2) Switch on the transmitter. 3) Touch the CH/ON key slightly to select the parameters to be edited. 4) Use the Select key to set the proper channel / group. - Adjust from the transmitter, 2) Manually Selecting Frequency Turn on the receiver . After touch the MENU key, the 'Group' indicated on the LCD display flashes, and use the UP/DOWN key to select the right group, after it is done, press 'Mem' to store the settings. To edit the preset channel or other parameters, please press again the MENU key, and so on. 13 Remark: some frequencies should be scanned manually by adjusting UP/DOWN Key, please refer to use's manual of UR-81DR for details! 1) Auto Scan Turn on the receiver, press the MEM key for a few seconds to enter into the auto scan mode. You can see"SCAN" flashes on the top left of the LCD, it means the auto scan function has been activated. under the auto scan mode, the scan function automatically searches the receiver's entire frequency band from start to stop. During the search, these presets of GROUP, CHANNEL and frequency keep flashing as they are scanned. As soon as the stop frequency is reached, the scan will be stopped automatically, the value of frequency is keeping flashing channel preset, press the MEM key, you can save the information. - Controlled from the receiver, there are two options, To make the operating frequency matched between the transmitter and the receiver, 4.3 Operating frequency matches between the receiver and the transmitter Fig 13 Remaining battery life display Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. If the rechargeable batteries are used, - Please keep the batteries inside, and use the charger (optional accessory, provided by the manufacturer) to recover the batteries. - During the charging process, the "Remaining battery life display" flashes. - Normally, the battery should be recharged within 6-hour. Please be advised to use only UM3 size AA 1.5V, one pair batteries for power supply. 4.2.3 Battery Replacing And Charging Fig 12 Note: when the transmitter is muted, the microphone couldn't send out any AF signal, that means, no sound has been sent out from the microphone. 3.2 UP-8H, Handheld Transmitter 1 Antenna Input Socket Allow you to connect plug-in antennas, remote antennas, or even a complex antenna network. 2 XLR Audio Output This is a professional balanced XLR output connector. 3 Audio Output Jack This is a professional unbalanced output jack. 4 DC Input It is used to connect an attached adapter. THE REAR PANEL 5 MEM key It is equipped with two functions, memo function, and auto scan function. 4 Menu key Via this key, you can choose the right function you want. 3 Display The LCD shows RF/AF signal, remaining battery life of the transmitter, group value, channel value and the selected frequency. 2 UP/DOWN key In the menu mode, you can choose the right value via these two keys. 3 3.3 UP-8P series, Body Pack Transmitter 7 Antenna The antenna is integrated into the transmitter body; to get effective RF transmission, never cover the antenna with hand, etc. Connect the optional recharger(see fig) with this mini jack for battery recharging. Please make sure that it is the rechargeable batteries inside before plug the recharger with the mini charge jack. 6 Charge Jack The unit may be powered from a dry or rechargeable battery. 5 Battery Compartment 4 SELECT Key Use this key to edit the parameters in operation mode. Keep pressing this key for a few seconds, the unit will enter into the mute mode, repeat for unmute. 3 CH/ON Key Keep pressing this key for a few seconds, the unit will be powered on or off. After it is switched on, touch this key slightly to select the parameter which you want to edit, such as the preset channel, preset group, PL (RF power level), and Lock/unlock; In this mode, if there is no further operation in the next few seconds, it will return to the main menu, and the LCD displays again the current preset frequency in MHz, as well as the battery status. Generally, the LCD displays the current operation status. 2 LCD Display Extremely rugged spring steel mesh grill to protect the capsule underneath in tough stage or live performance. 1 Massive Front Grill Fig 11: UNLOCK 12 Keep pressing the SELECT key for a few seconds, the unit will enter into the mute mode (see the fig 12), repeat for unmute. 4.2.2 Mute Mode Operation Fig 10: LOCK - Touch the CH/ON key slightly to select the edited parameter of Lock/Unlock (refer to Fig 10 & 11), then use the SELECT key to specify Lock or Unlock; - Several seconds later after that, the system stores the settings automatically, and LCD display comes back to the main menu which shows the current operation status. To enter into the Lock mode, please follow the below procedure, Since the CH/ON and SELECT keys may be easily activated by simple touch, to avoid any Mis-action during the live application, the Lock/Unlock is provided by this system for touch-proof under the Locked situation. In case the system is locked, you can still use the CH/ON key to select the edited parameters, but, except for the Lock/Unlock, others can't be edited. - LOCK Function Fig 9 Please follow the below procedure to select the proper RF output power, - Touch the CH/ON key slightly to select the edited parameter of PL (refer to Fig 9), then use the SELECT key to specify the proper RF output Power version; - Several seconds later after that, the system stores the settings automatically, and LCD display comes back to the main menu which shows the current operation status. - PL 0, the output power is 3dBm; - PL 1, the output power is 5dBm; - PL 2, the output power is 12dBm; But, It's a different from UP-8P, Three different RF output power versions are available of UP-8H, - PL 0, the output power is 5dBm; - PL 1, the output power is 10dBm; - PL 2, the output power is 15dBm; - RF Output Power Select Fig 6 Remaining battery life Fig 7 11 Fig 8 - Turn on the unit first. - Touch the CH/ON key slightly to select the edited parameter of Channel (refer to Fig 8), then use the SELECT key to specify the proper channel. - Touch the CH/ON key slightly again to select the edited parameter of Group (refer to Fig 7), then use the SELECT key to specify the proper Group. - Several seconds later after that, the system stores the settings automatically, and LCD display comes back to the main menu which shows the current operation status. For example, in F7 frequency band, if you want to select the frequency preset of 811.125MHz (Group 6, Channel 6), please follow the below procedure, The frequency range of this system is UHF, 470MHz ~ 900MHz, and it is divided into 8 frequency bands (F1 ~ F8) according to the country's EMC regulations; For each frequency band, to select the proper frequency preset, please first pickup the right Group, then specify the Channel; For details please refer to the Annex; It is the multi-channels PLL synthesized system. In practice, to effectively avoid the interference from any lighting equipment, computers, fax machines, etc nearby, it is usually advised to switch to another frequency to get best performance. - Frequency select After the transmitter is switched on, touch the CH/ON key slightly to select the parameter which you want to edit, such as the preset channel, preset group, PL (RF power level), and Lock/unlock. Preset frequency Press and hold the CH/ON key for a few seconds, then the transmitter is powered on. Now, the LCD displays the current operation status: 4.2.1 Edit The Parameter 4.2 For the UP-8H/8P series transmitters 4 3 Pin 1, for Guitar, bass and keyboards Pin 2, GND Pin 3, Phantom power supply for Condenser microphone Pin 4, for Dynamic or condenser microphone 8 Antenna It is the flexible antenna. To get effective transmission, never cover the antenna with hand, clothes, etc during the operation, and always position the transmitter nearby the receiver. 7 Belt clip It is the detachable belt clip for easy carry during the live applications. This unit may be powered from one pair dry or rechargeable batteries, UM3 size AA 1.5V. 6 Battery Compartment With the rechargeable batteries put inside, use the charger (optional accessory, provided by the manufacturer) to recharge the batteries. For detail operation, please refer to chapter 4.2.3, Battery replacing and charging. 5 Charge Jack 4 Mini 4P connector This connector is used to connect the unit with the clip microphones, for example, HM-38 or HM-58 condenser microphones. 3 SELECT Key Use this key to edit the parameters in operation mode. Keep pressing this key for a few seconds, the unit will enter into the mute mode, repeat for unmute. 2 CH/ON Key Keep pressing this key for a few seconds, the unit will be powered on or off. After it is switched on, touch this key slightly to select the parameter which you want to edit, such as the preset channel, preset group, PL(RF power level) and Lock/unlock. In this mode, if there is no further operation in the next few seconds, it will return to the main menu, and the LCD displays again the current preset frequency in MHz, as well as the battery status. Generally, the LCD displays the current operation status. 1 LCD Display B Fig 1 - Mute Function In mute mode, use UP/DOWN key to on/off the mute function.(fig 2: mute function off, fig 3: mute function on), press the MEM button to keep the information. Note: when the transmitter is muted, no audio signal will be send out from the receiver. Press the MENU button, "GROUP" is flashing, you can choose the right frequency group you need via the UP/ DOWN button, when the frequency group is set, please press MEN button to store the information. Press the MENU button two times, "CHANNEL" is flashing, you can choose the right subchannel you need via the UP/DOWN button, when the subchannel you need is set, please press the MEN button to save it. - Manual Selecting Frequency - Auto Scan When the receiver is powered on, press and hold the MEN key for one second, the receiver is in auto scanning. The scan function automatically searches the receiver's entire frequency band from start to stop. During the search, the audio output is muted and the display indicates the frequencies in MHz as they are scanned. As soon as the correct frequency is reached, the scan will be stopped automatically, the value of frequency will be flashing, press the MEM key, you can save the information. Remark: some frequencies should be scanned manually by adjusting UP/DOWN key, please refer to Annex for details! A: Frequency group B: Subchannel C: Mute(if the mute function is engaged, the mute label is shown, if not , the label disappears) D: The selected frequency E: Remaining battery life of transmitter F: Audio bar graph indicating the receiver audio level G: RF bar graph indicating the field strength of the received signal. 4.1 For the UR-81DR, PLL UHF Diversity Receiver 4. OPERATION Fig 3 mute function on 75.0dB 71.7dB 68.3dB 65.0dB 10 Table 81.7dB 78.3dB 88.3dB 85.0dB 91.7dB 95.0dB squelch threshold No. 10 Fig 5 The job of a squelch circuit is to reduce audible noise. It eliminates noise during pauses in the audio signal by muting the receiver every time the audio level drops below a defined threshold. The squelch control on the receiver sets this threshold. Use the squelch control with care! If the squelch threshold is too high, the squelch will not only cut out noise but mute quiet audio signals as well because the squelch responds to the detected voltage and cannot distinguish between wanted signal and noise. Besides that, a too high squelch threshold also decreases the usable range. In the squelch control mode(fig 5), use the UP/DOWN key to select squelch threshold. In order to achieve easy operation, the squelch threshold is divided into10 levels, please refer to table. - Squelch Control Fig 4 In output level adjusting mode(see fig 4), use the SELECT button to adjust the output level. The output level has 3 choices, 0 indicates the output level is 500mV, 1 indicates the output level is 300mV, 2 indicates the output level is 150mV. Note: the function is only applied to the level of Balanced output. - Output Level Adjusting Fig 2 mute function off
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2008:04:16 16:38:53+08:00 Modify Date : 2008:04:16 16:38:53+08:00 Page Count : 14 Creation Date : 2008:04:16 08:38:53Z Mod Date : 2008:04:16 08:38:53Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : pc47 Metadata Date : 2008:04:16 08:38:53Z Creator : pc47 Title : UR-81DR .pdfEXIF Metadata provided by EXIF.tools