SIGEYI Technology PM0630 DLS Cycling Power Meter User Manual

SIGEYI Technology(Shenzhen) Co.,LTD DLS Cycling Power Meter Users Manual

Users Manual

Download: SIGEYI Technology PM0630 DLS Cycling Power Meter User Manual
Mirror Download [FCC.gov]SIGEYI Technology PM0630 DLS Cycling Power Meter User Manual
Document ID4086754
Application IDlmID904QoXYiN8XcDniewg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize30.43kB (380381 bits)
Date Submitted2018-11-28 00:00:00
Date Available2018-11-28 00:00:00
Creation Date2018-11-19 08:52:53
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2018-11-19 08:52:53
Document TitleUsers Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: admin

DLS Power Meter User Guide
Version 1.2
Brief introduction:
DLS is a pair of power meter module installed on bicycle crank. It can measure the power and
cadence of the left and right side. DLS has dual protocol of ANT+ and Bluetooth, which can easily
link various bike computers and mobile phone APPs. DLS is powered by built-in lithium-ion
battery, which are charged using a dedicated charging cable.
Specifications:
Data: power, cadence , left/right balance
Power measurement accuracy: + / - 2%
Power measurement range: 0~1800W
Cadence measurement range: 30~180RPM
Operational Temperature: - 10 ℃ to 50 ℃
Battery life: 120h
Standby time: More than 1 year
Waterproof Level: IP67
Data protocols: ANT+, BlueTooth4.0
Weight: 50 g
ANT ID
The ANT ID is marked on the power meter modules. Each side has an ANT ID.
Connection
Rotate the crank 1 to 2 cycles to make sure the power meter is waked-up while LED flashes once.
Turn on bike computer, search and connect power meter directly, or input one of the two ANT ID.
Working mode:
The DLS consists of power measurement modules on the left and right, which are connected via
wireless communication. The two modules can work together (Dual side mode) or independently
(Single side mode).
Working mode
LED status
occurrence
The left and right modules are
Dual side mode
Both LED off
awake and connected to each
other.
The two modules are not
Single side mode
One side LED on
Power data
Power = L_Power +
R_Power
Power = L_Power*2
connected to each other, or not
Or
a pair.
Power = R_Power*2
Reversely rotate the crank for more than 5 cycles to switch from single side mode to dual side mode.
Sleep/wake up:
When DLS standing still for more than 4 minutes, the power meter enters sleep state. Rotate the
crank to wake it up.
Zeroing
Method 1: Use bike computer
When the power meter is awakened, make the crank vertical to the ground, hands and feet leave
the pedal, and press the zero button of the bike computer to make the power meter zeroing.
Method 2: Reverse rotate
DLS provide a special and easy method for zeroing. Reverse rotate the crank by hand (while the
crank is in no payload status) more than 6 cycles. Then the zeroing operation is finished.
Charging:
Please use the standard 5V USB power supply and the dedicated magnetic charge cable to charge
the DLS.
When charging, the LED is on. LED turns off when fully charged which may cost about 2~3 hours.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Language                        : zh-CN
Tagged PDF                      : Yes
Author                          : admin
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2018:11:19 08:52:53+08:00
Modify Date                     : 2018:11:19 08:52:53+08:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2APOZ-PM0630

Navigation menu