SOLEUS Air Conditioner Room (42) Manual L0702037

PE1 09R-30 L0702037

User Manual: SOLEUS SOLEUS Air Conditioner Room (42) Manual SOLEUS Air Conditioner Room (42) Owner's Manual, SOLEUS Air Conditioner Room (42) installation guides

Open the PDF directly: View PDF PDF.
Page Count: 14

DownloadSOLEUS  Air Conditioner Room (42) Manual L0702037
Open PDF In BrowserView PDF
9,000 BTU Portable Air Conditioner
PE1-09R-30
Operating

Instructions

Model No. PE I-O9R-30
®

© 2006 Soleus

Air International

Thank you for choosing

a Soleus Air PE1-09R-30

Portable

Air Conditioner.

This owner's

manual

will

provide you with valuable information necessary for the proper care and maintenance
of your new
product. Please take a few moments to thoroughly read the instructions and familiarize yourself with
all the operational aspects of your new Soleus Air Portable Air Conditioner.
For your own records, please attach a copy of your sales receipt to this manual.
name/location,
date purchased, and serial number below:

Also, write the store

Store Name:
Location:
Date Purchased:
Serial Number

(located

IMPORTANT

on back of unit):

INSTRUCTIONS

Before installing and using your portable air conditioner,
manual in a safe place for future reference.

please read this owner's manual carefully. Store this

1) Always place the unit on a level surface.
2)

Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this
manual.

3)

Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or
outlet grilles.

4)

The unit must be connected to a correctly grounded power supply.

5)

Do not start or stop the unit by inserting or pulling out the power plug.

6)

Do not use an adapter plug or extension cord.

7)

Do not use the unit in the immediate

8)

Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this

surroundings

of a bath, a shower or a swimming pool.

manual.
9)

Do not let children play near this unit.

10) Always inspect the cord for signs of damage before use. If the power cord is damaged,
by the manufacturer

it must be replaced

or a qualified service technician.

11) When cleaning the unit, always turn the unit offand

unplug the power cord.
2

PACKAGE CONTENTS
Portable

Air Conditioner

Exhaust Hoses
Hose Adapters

(2)
(2)

Window Kit Adapter
Remote Control
AAA Batteries

(2)

(2)

Window Kit - 3 Sliding Panels (1 dual hose panel, 2 extension
Air Intake and Outlet Covers (2)
Owner's Manual

panels)

WARNING:
This unit has a voltage rating of 115
volts. The cord has a plug as shown in A. An adapter
shown in C is available for connecting
three-blade
I;IT,_R fir G_Le4_D

as

grounding-type
plugs to two-slot receptacles.
The
grounding lug extending from the adapter must be connected to a permanent ground such as a properly
grounded outlet box. The adapter should not be used if
a three-slot grounded receptacle is available.
DO NOT DEFEAT
THE GROUNDED

THE SAFETY
PLUG.

PURPOSE

OF

SPECIFICATIONS
•

•

The cooling capacity is measured at an ambient temperature
of DB 86 °F, WB 78 °F.
Noise level is measured at a
distance of 3.28 ft away from
the front of the unit, when the
unit is in cooling mode.

•

Power consumption is measured when the fan runs at the

MODEL
COOLING CAPACITY
HEATING CAPACITY
DEHUMIDIFYING CAPACITY
POWER

COOLING
HEATING

AIR FLOW VOLUME
POWER SOURCE

highest speed setting.
•

•

These specifications are for
reference only. For actual data,
please refer to the rating label
on the back of the unit.
If the environment temperature
is higher than the max operating temperature or lower than
the minimum operating temperature, the air conditioner
may not work properly.

SOUND PRESSURE LEVEL
NET WEIGHT

PE1-09R-30
9,000 BTU/H
1200 Watts
50 pts/Day
980 W
1350W
177 CFM
115V~60 HZ
9/12 AMP
HEATING/COOLING
46 dB(A)
75 Lbs

OPERATING

COOLING

60.8°F-108°F

TEMPERATURE

HEATING

23T-89.6_F

DIMENSIONS

ASSEMBLED

17.75" W x 18.25" D x 32.5" H

PACKAGE

21" W x 18.5" D x 34.5" H

REFRIGERANT

R22

rn=

11 I

PRODUCT DIAGRAM

Control

Signal

Panel

Rece

• Back
Evaporator Air Intake
Filter Compartment
Air Ou

Air Intake

Drain

Hose

Port

4

PARTS & ASSEMBLY

PARTS

EXHAUSTHOSE

Exhaust Hose
Hose Adapter
Window Kit
Adaptor

WINDOW

KIT

ASSEMBLY

& INSTALLATION

INSTALLATION
When the unit is operating as an air conditioner

or dehumidifier,

the unit draws in fresh outdoor air and exhausts hot air

out of the room to complete the air exchange. When the unit is operating in fan or heater modes, no outdoor air exchange
takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan or heater.
NOTE: The supplied window kit can be installed
(approximate length).
MOUNTING THE EXHAUST

in sliding windows and sliding glass doors up to 8 ft. long

HOSES

•

Choose a suitable location, near a grounded electrical
packaging and locate components.

outlet and suitable window or door. Remove

•

Extend both ends of the exhaust hoses approximately

6 inches.

•

Screw the window kit adapter onto one end of the exhaust hose clockwise. Screw the hose adapter onto
the other end of the exhaust hose clockwise. Repeat on the other exhaust hose.

•

Remove outlet covers from the back of the unit by screwing them counter-clockwise,

•

Mount the exhaust hoses onto the back of the unit by locking the hose adapters into place.

then lifting up.

............................

DUAL HOSE WINDOW

KIT INSTALLATION

f

FOR DUAL HOSE PORTABLE

L....................

CONTROL

PANEL,

DISPLAY,

& OPERATING

INSTRUCTIONS

IIII

CONTROL

PANEL & MULTI-COLOR

DISPLAY

CONTROL PANEL

_BUTTON

MODEBUTTON
TIMER BUTTON_
OSCILLATION)

FAN SPEED BUTTON

MUL TI-COLOR DISPLA Y

NC
DEiUM"

FIN

i EAT
_

TIMER ON
/

Ill!

FAN

IlII

S,f P

ill

"" II

_Ull

IIII

'"'n

iiii

(_41

TIMER OFF

(_4o

"_ • 4' 11!i
iiiI""
i'll/"lJlll
_111
I_11lillll
r..................................................
_
=_# i"

""
'ill

Jill

i

Illl

""

It

iiili

;lll i
i

r

i

\
OSCILLATION ON/OFF

EMERGENCY
CONDENSATEBUCKETFULL


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 14
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Wed Aug 15 09:52:30 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu