SOLT SOLTREPEATER AUXILIARY REPEATER User Manual

SOLT CO., LTD AUXILIARY REPEATER

User Manual

Download: SOLT SOLTREPEATER AUXILIARY REPEATER User Manual
Mirror Download [FCC.gov]SOLT SOLTREPEATER AUXILIARY REPEATER User Manual
Document ID2139281
Application IDP2FzCKXG7lbArhU1FWvg+Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize95.67kB (1195907 bits)
Date Submitted2013-12-11 00:00:00
Date Available2013-12-11 00:00:00
Creation Date2013-10-31 11:49:39
Producing SoftwareAcrobat Distiller 9.5.5 (Windows)
Document Lastmod2013-12-04 11:06:32
Document TitleUser_s Guide (Repeater)_ENG_인증용.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: in

Supplies Per Models
Repeater
Installation Deck (Screw 2pcs)
Repeater
User's Guide
SOLTREPEATER
Adaptor
Specification
Model
SOLTPEPEATER
Frequency(MHz)
433.0500 ~ 434.7900
Freq Stability
±5 ppm
Data Rate
1800 bps
Channel space
12.5 KHz
Modulation
FSK (±3KHz)
Output Power
10mW (Max) - Conducted Power
Sensitivity
-118dBm (at 12dB)
Power Supply
DC 12V/1A Adapter
Dimension(mm)
146W × 90L x 32H
Battery Life cycle
External Power
Antenna
Tilt base snap-in_dipole (External)
Repeater
Repeater
Name of each section
Front
① Retractable antenna
① Folding antenna : 180 degrees pivot
② Bell number indicator : activated led number varies by different models.
PWR
Red led indicates power is on
RX
Blinking Red led indicates bell model
TX
Blinking Green led indicates pager model
③ Wall mount holes :
Refer to item 4 of Installation Guide in page 53.
② Status indicator
[Wall mount bracket installation]
③ Holes for wall mount
MENU / ESC
Back
.&/6
&4$
ⶸ
ⶼ
ⶾ
ⶺ
4&5
183
·Menu button in setting mode
· alphabetic and numeric changing button
▲ ▼
·up /down
◀ ▶
·left / right buttons
SET / PWR
/P3FDFJWF
④ Setting buttons
④ Setting buttons
·Storing button for set value
·Dower button
⑤ Display
Missed call icon
/P3FDFJWF
⑤ Call number Display
⑥ Adapter input: DC12V 1A (Use the supplied adapter)
⑥ Adapter input
(DC 12V 1A)
Limited accessary warranty: malfunctioning of
supplied adapter during its use is not covered by
manufactures' warranty.
Purchasing an adapter with AC110~22OV input,
DC12V 1A output is recommended.
[Back cover]
Input : AC110~220V
Output : DC12V 1A
Repeater
Repeater
Installation guide
To assure the finest performance, please read this manual carefully.
② Bracket Installation
① Location
※ Transmitter must be installed with in 100% reception area.



Install at roof like picture above, it is better if antenna direction go downward.
In the case of cannot be installed to the roof install rear the roof.
Once decided where to install, fix the mount.
③ Power Cord (Use the adapter provided in the package.)
Transmitter (Main or Bell) Location.
100% Reception Area.
It is most appropriate to install A location which is located within 100% reception area.
(See map a picture above)
④ Wall Mounting (Pull down the unit until clicking sound is heard. )
※ This product is needed to avoid moisture and water (It can be cause of breakdown)
Recommend to install away from water. If needed to install outside of building, install
where does net get wet.
Repeater
Repeater
Repeater selection mode (Cbr / CPr)
·Sets the repeater as call bell repeater or pager repeater.
Repeater setting modes
⑴ Press and hold (MENU) button for 3 seconds.
Listed items below can be set by using user setting buttons.
MENU
ESC
E1
Repeater selection mode
Sets the repeater as call bell repeater or pager repeater.
E2
Download mode
Downloads registered call numbers from main transceiver.
▲
▼
◀
▶
SET
PWR
▶
SET
PWR
·Entering setting mode as [E1 Rsel] is displayed.
⑵ Press (SET) button.
[TBD]
MENU
ESC
E3
No receive call number setting mode
Selects call numbers that are not desired to receive.
E4
Call redundancy interval setting mode
Sets interval for redundant calls. (default value is 3 seconds)
▲
▼
◀
· [Cbr or CPr] is displayed.
⑶ Press (▲▼) buttons. (Cbr / CPr)
E5
Call number deleting mode
Deletes registered call numbers.
E6
Call number registering mode
Registers new call numbers.
MENU
ESC
▲
▼
◀
▶
SET
PWR
Cbr : Extends bell receiving range by relaying
bell's data to main transceiver.
CPr : Extends pager receiving range by relaying
main transceiver data to pager.
⑷ Press (SET) button.
MENU
ESC
E7
▲
▼
◀
▶
SET
PWR
·[E1 Rsel] is displayed and returns
to previous step.
TX delay time setting mode
Sets delay time for received call number from bell.
※ Press (▲▼) buttons to select different setting mode.
⑸ Press (MENU) button.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·[ST-r5] is displayed and ready for reception.
Repeater
·Selects call numbers that are not desired to receive.
·Downloads registered call numbers from main transceiver.
⑴ Press and hold (MENU) button for 3 seconds.
⑴ Press and hold (MENU) button for 3 seconds.
MENU
ESC
MENU
ESC
▲
▼
◀
▶
SET
PWR
Repeater
No receive call number setting mode
Download mode
▲
▼
◀
SET
PWR
▶
·Entering setting mode as [E1 Rsel] is displayed.
·Entering setting mode as [E1 Rsel] is displayed.
⑵ Press (▲) button twice.
⑵ Press (▲) button once.
MENU
ESC
▲
▼
◀
[TBD]
▶
SET
PWR
MENU
ESC
▲
▼
◀
SET
PWR
▶
·[E3 Daof] is displayed.
·[E2 Down] is displayed.
⑶ Press (SET) button.
MENU
ESC
▲
▼
◀
SET
PWR
▶
·Registered call number is displayed.
⑶ Press (SET) button.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·[---] is displayed.
⑷ Press (▲▼) buttons to select a Call number don't want to receive.
MENU
ESC
⑷ Press (SET) button.
MENU
ESC
▲
▼
◀
▲
▼
◀
SET
PWR
▶
·Selected call number is displayed.
⑸ Press (SET) button to select desired receiving mode.
▶
SET
PWR
·[---] is displayed during downloading is in progress.
·[E2 Down] is displayed when downloading is
completed and returns to previous step.
MENU
ESC
▲
▼
◀
SET
PWR
▶
·[No Receive] button toggles each time
SET button is pressed.
※ To set another receiving mode, repeat steps (4) to (5).
※ Press (▲▼) buttons to select different setting mode.
⑹ Press (MENU) button.
⑸ Press (MENU) button.
MENU
ESC
MENU
ESC
▲
▼
◀
▶
SET
PWR
▲
▼
▶
SET
PWR
·[ST-r5] is displayed and ready for reception.
·[ST-r5] is displayed and ready for reception.
/P3FDFJWF
10
◀
e.g.) Call number 200 is set to not receive when
[No Receive] icon is displayed.
11
Repeater
·Deletes registered call numbers.
·Sets interval for redundant calls.
⑴ Press and hold (MENU) button for 3 seconds.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Entering setting mode as
[E1 Rsel] is displayed.
▲
▼
◀
▶
SET
PWR
·[E4 Dupt] is displayed.
▲
▼
◀
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Entering setting mode as [E1 Rsel] is displayed.
MENU
ESC
▲
▼
◀
▶
SET
PWR
▶
SET
PWR
·[E5 Dele] is displayed.
⑶ Press (SET) button.
⑶ Press (SET) button.
MENU
ESC
⑴ Press and hold (MENU) button for 3 seconds.
⑵ Press (▲) button 4 times.
⑵ Press (▲) button 3 times.
MENU
ESC
Repeater
Call number deleting mode
Repetition call setting mode
▶
SET
PWR
·[3] is displayed.
MENU
ESC
▲
▼
◀
·Registered call number is displayed.
※ 3 is set for default. (Unit : second)
⑷ Press (▲▼) buttons. Sets the desired number.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Selected number is displayed.
⑸ Press (SET) button.
MENU
ESC
▲
▼
◀
⑷ Press (▲▼) button. Select the call number you want to delete.
MENU
ESC
▲
▼
◀
▶
SET
PWR
▶
SET
PWR
·Selected call number is displayed.
⑸ Press (SET) button.
▶
SET
PWR
·[E1 Rsel] is displayed and returns to
previous step.
MENU
ESC
▲
▼
◀
·" It has been deleted." is played.
·To delete another call number,
repeat the processes from (4) to (5).
※ Press (▲▼) buttons to select different setting mode.
⑹ Press (MENU) button.
⑹ Press (MENU) button.
MENU
ESC
12
▲
▼
◀
▶
SET
PWR
·[ST-r5] is displayed and ready for reception.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·[ST-r5] is displayed and ready for reception.
13
Repeater
Repeater
Call number registering mode
·Registers new call numbers.
⑴ Press and hold (MENU) button for 3 seconds.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Entering setting mode as [E1 Rsel] is displayed.
⑵ Press (▲) button 5 times.
MENU
ESC
▲
▼
◀
▶
SET
PWR
⑸ Press (SET) button.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Selected-number from (4)section is displayed
on the screen and the number stop blinking.
⑹ Press the button to register.
·[E6 Breg] is displayed.
·Registration for selected call number is completed.
·The number of screen is again blinking.
䌫䌬䌅䌚䌍
⑶ Press (SET) button.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Blinking [0] is displayed.
·To register another Bell, repeat the processes from (4) to (6).
⑷ Press (▲▼◀▶) buttons. sets desired to call number.
MENU
ESC
▲
▼
◀
▶
SET
PWR
· Press (◀▶) buttons to move to different digits.
· Press (MENU) button to toggle input mode from
/ to numeric and English modes.
⑺ Press and hold (SET) button for 3 seconds when registration is finished.
MENU
ESC
Number
mode
▲
▼
◀
▶
SET
PWR
·[ST-r5] is displayed and ready for reception.
%ODQN
English
mode
%ODQN
14
15
Repeater
TX delay time setting mode
·Sets delay time for received call number from bell.
⑴ Press and hold (MENU) button for 3 seconds.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Entering setting mode as [E1 Rsel] is displayed.
⑵ Press (▲) button 6 times.
MENU
ESC
▲
▼
◀
▶
SET
PWR
▶
SET
PWR
·[E7 Txdt] is displayed.
⑶ Press (SET) button.
MENU
ESC
▲
▼
◀
·[0] is displayed.
·10(1Second), 20(2Second) ... 100(10Second)
※ '0' is default value :
transmits as soon as receiving a call.
⑷ Press (▲▼) buttons. Sets the desired number.
MENU
ESC
▲
▼
◀
▶
SET
PWR
·Selected number is displayed.
⑸ Press (SET) button.
MENU
ESC
▲
▼
◀
▶
SET
PWR
· [E1 Rsel] is displayed and returns to
previous step.
※ Press (▲▼) buttons to select different setting mode.
⑹ Press (MENU) button.
MENU
ESC
16
▲
▼
◀
▶
SET
PWR
·[ST-r5] is displayed and ready for reception.
FCC compliance Information
When used the This device complies with part 15 of FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference. and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
Cautions
Modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense
17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Format                          : application/pdf
Title                           : User_s Guide (Repeater)_ENG_인증용.indd
Creator                         : in
Create Date                     : 2013:10:31 11:49:39+09:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2013:12:04 11:06:32+09:00
Metadata Date                   : 2013:12:04 11:06:32+09:00
Producer                        : Acrobat Distiller 9.5.5 (Windows)
Document ID                     : uuid:6c0c538d-b91a-4816-b92e-95d8d0b5ad0b
Instance ID                     : uuid:5ea12c0a-1e11-4f40-9049-b6d38c0603dc
Has XFA                         : No
Page Count                      : 8
Author                          : in
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ABE3SOLTREPEATER

Navigation menu