User Manual
SMDR-NH124(Remote Unit) User Manual Confidential & Proprietary 1/27 REVISION HISTORY Version Issue Date V 1.0 July. 14, 2015 No. of Pages Initials Details of Revision Changes Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.st.co.kr or send email at sjkim@st.co.kr This manual is produced by Global Business Division Business Team 1. Printed in Korea. Confidential & Proprietary 2/27 Contents Section1 Safety & Certification Notice................................................................... 5 Section2 System Overview ..................................................................................... 9 2.1 Purpose ......................................................................................................... 10 2.2 SMDR-NH124 ................................................................................................ 11 2.3 Dimension ..................................................................................................... 12 Section3 System Installation ................................................................................ 13 3.1 ROU Installation ........................................................................................... 13 3.1.1 ROU Enclosure installation ................................................................... 13 3.1.2 ROU Power Cabling ............................................................................... 17 3.1.3 Optical Cabling ...................................................................................... 18 3.1.4 GND Terminal Connection .................................................................... 19 3.1.5 Coaxial cable and Antenna Connection .............................................. 20 3.1.6 Insertion of RDU..................................................................................... 20 3.1.7 RDU Specifications Per band ............................................................... 21 Confidential & Proprietary 3/27 Contents of Figure Figure 3.1 – ROU Outer Look ........................................................................ 12 Figure 3.2 – How to install ROU ..................................................................... 14 Figure 3.3 – Dimension used to install ROU on the WALL ............................. 14 Confidential & Proprietary 4/27 Section1 Safety & Certification Notice Confidential & Proprietary 5/27 “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.” - Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters. - When working with units outdoors, make sure to securely fasten the door or cover in an open position to prevent the door from slamming shut in windy conditions.. - Use this unit only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. - Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 200cm minimum clearance from the antenna while the system is operating. - Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation. - Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors. - To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm. - Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure. - Allow sufficient fiber length to permit routing without severe bends. - For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible. - A readily accessible disconnect device shall be incorporated external to the equipment. Confidential & Proprietary 6/27 - This power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device - Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote. Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system. All components connected to this device must operate in the frequency range of this device. - Only 50 ohm rated antennas, cables and passive components operating from 150 - 3 GHz shall be used with this device. - The following notice: "The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device." - The head end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station. - Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and - Access is through the use of a TOOL or lock and key, or other means of security, and is on trolled by the authority responsible for the location. - Signal booster warning label message should include Confidential & Proprietary 7/27 - Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor-only restrictions is prohibited. - Certification FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24,27 and 90(Class B) UL/CUL: This equipment complies with UL and CUL 1950-1 Standard for safety for information technology equipment,including electrical business equipment FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040 Confidential & Proprietary 8/27 Section2 System Overview 2.1 Purpose 2.2 SMDR-NH124 Confidential & Proprietary 9/27 2.1 Purpose SMDR-NH124 is a coverage system for in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities. Shopping malls Hotels Campus areas Airports Clinics Subways Multi-use stadiums, convention centers, etc. The system helps improve in-building radio environments in poor condition and make better poor RSSI and Ec/Io. By providing communication services at every corner of buildings, the system enables users to make a call at any site of buildings. The system uses both analog (AMPS) and digital (TDMA, CDMA and WCDMA) methods. The SMDR-NH124 system supports communication standards and public interface protocols in worldwide use. Frequencies: VHF,UHF, 700MHz, 800MHz,850MHz 900MHz,1900MHz,2100MHz, etc. Voice protocols: AMPS,TDMA, CDMA,GSM,IDEN, etc. Data protocols: EDGE,GPRS,WCDMA,CDMA2000,Paging, etc. SMDR-NH124 is in modular structure per frequency. To provide desired frequency in a building, all you need to do is to insert a corresponding frequency module into each unit. As it delivers multiple signals with one optical cable, the system, in one-body type, does not require additional facilities whenever new frequency is added. The system is featured with the following: Flexibiltiy & Scalabiltiy Support fiber-optic ports up to 39 Clustering multiple-buildings (campus) as one coverage Modular structures Modular frequency upgrade Plug-in type module Multi-Band, Multi Operator Confidential & Proprietary 10/27 2.2 Signals with a plurality of service provider transmit simultaneously Support multi-operator in a band Low OPEX / CAPEX Compact design Upgradable design Easy installation and maintenance Web Based SNMP or GSM Modem or UDP support (Optional) SMDR-NH124 ROU receives TX optical signals from ODU or OEU and converts them into RF signals. The converted RF signals are amplified through High Power Amp in a corresponding RDU, combined with Multiplexer module and then radiated to the antenna port. When receiving RX signals through the antenna port, this unit filters out-of-band signals in a corresponding RDU and sends the results to Remote Optic Module to make electronic-optical conversion of them. After converted, the signals are sent to a upper device of ODU or OEU. ROU can be equipped with up to three RDUs (Remote Drive Unit) and the module is composed of maximal Dual Band. Confidential & Proprietary 11/27 2.3 Dimension Figure 3.1 – ROU Outer Look ROU is designed in a cabinet, and provides the following functions and features. Item Spec. Remark Size(mm) 482.6(19“) x 258 x560, Including Bracket Weight 35.45 Kg Power consumption 265 W Operating Temperature ‐10 to +50°C Confidential & Proprietary 12/27 Full Load Ambient Temperature Section3 System Installation 3.1 3.1.1 ROU Installation ROU Enclosure installation ROU is designed to be water- and dirt-proof. The unit has the structure of One-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of NEMA4. ROU can be mounted into either of a 19” Standard Rack or on a Wall. Basically, ROU has both of a Wall Mount Bracket and a Rack Mount Bracket. Depending on the use of the Rack Mount Bracket, the bracket can be removed. The following shows dimension of the fixing point for the Wall Mount Bracket. Confidential & Proprietary 13/27 Figure 3.2 – How to install ROU Figure 3.3 – Dimension used to install ROU on the WALL Confidential & Proprietary 14/27 ROU Wall Mount Installation Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it. For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure. Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure. Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 12 M5 Wrench Bolts in total except bolts used for the fixing groove. Confidential & Proprietary 15/27 ROU Rack Mount Installation Like other units, ROU is designed to be inserted into a rack. The unit occupies around 13U of space except cable connection. ROU component ROU has the following components: No. Common Part Unit Remark Enclosure Including Rack & Wall cradle 1EA RCPU 1EA R_OPTIC With SC/ACP adaptor 1EA RPSU Alternative DC-48V or AC 120V 1EA Multi-Plexer 1EA Power Cable Optional Part Description RDU+BPF Confidential & Proprietary - MS Connector with 3 hole to AC 120 plug(AC) - MS Connector with 2 lug termination(DC) 800PS,800PS+900I+Paging,850C,850C+700PS, Up to 3EA to 1900P+ AWS-1 RDU, VHF+UHF(NO BPF), be inserted 16/27 850C+700LTEC, 700LTEF+850C 700LTEF SISO RDU, 700LTEF SISO RDU Basically, the common part of ROU should have an enclosure and it is equipped with RCPU to inquire and control state of each module, R_OPTIC to make both of electronic-optical and optical-electronic conversions, RPSU to supply power for ROU and a Multi-Plexer to help share multiple TX/RX signals through one antenna. It should have Power Cable for external rectifier or to supply required power. In addition, RDU can be inserted and removed to provide service for desired band (Optional). 3.1.2 ROU Power Cabling ROU supports both of DC-48V and AC120V of input power. As RPSU for DC-48 and RPSU for AC120V are separated from each other, you need to select one of them in case of purchase order. RPSU for DC -48V and RSPU for AC 120V have the same configuration and capacity while each of the units uses different input voltage from each other. The following figure shows configuration of RPSUs for DC -48V and AC 120V. Confidential & Proprietary 17/27 MC Connector Lug Naming RPSU Terminal naming Remark numbering AC DC AC DC AC_H -48V AC-H -48V AC_N GND AC-N IN_GND GND DC NC FG FG Check if the connection is the same as one seen in the table above and make sure to turn the power ON. 3.1.3 Optical Cabling ROU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes electronic- optical conversion of RX signals. ROU has one optical module in it. As WDM is installed in the R_OPTIC module, two pieces of wavelength (TX:1310nm, RX:1550nm) can be sent/received with one optical core at the same time. ROU has SC/APC of optical adaptor type. For optical adaptor, SC/APC type can be used. To prevent the optical access part from being marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt. Confidential & Proprietary 18/27 Optical cables should be inserted into Optic Port outside of ROU. Using an optical slack devices in ROU, you need to coil around one or two roll of cables to be connected with the optical adaptor of ROPTIC. At this time, curvature of the optical cable should be at least 10Ø to prevent insertion loss from being increased. Through GUI, check if PD value of ROPTIC is in a tolerable range (+4~-1dBm). 3.1.4 GND Terminal Connection ROU has one GND terminal port where is on bottom side, like below GND LUG Take off the GND terminal port from enclosure and connect to ground cable, then fix it the position of enclosure again The opposite end of the ground cable should connect to the communication GND of building Confidential & Proprietary 19/27 3.1.5 Coaxial cable and Antenna Connection The coaxial cables which are connected to antenna distribued network connect to antenna port of ROU. Before connection, check the VSWR value of coaxial cable whether it is within specification using SITEMASTER . At this time, check if the Return loss have above 15Db or VSWR have below 1.5 The part of antenna connection fasten to port not to be loosed and not to be injected the dusty and insects 3.1.6 The antenna connected to ROU is only serviced in inbuilding Insertion of RDU ROU has slots to enable up to three RDU modules to be inserted into the unit. You can insert a RDU into any slot. It is not possible to provide services with a RDU module alone; you need to connect the module with Cavity BPF in any case. The table below shows types of RDU and CAVITY BPF: Multiplexer Interface No Unit naming Cavity BPF RF CABLE TX RDU 800PS 800PS BPF RDU 850C 850C BPF RDU TX CABLE 1EA RX CABLE 1EA BPF OUT TX CABLE 1EA BPF TX RX CABLE 1EA OUT 1900P DUP TX/RX CABLE 1EA RDU 800PS+900I+PA TX CABLE 1EA RDM TX 800PS+900I+PA BPF RX CABLE 1EA OUT RDU 850C+700PS TX CABLE 1EA RDM TX 850C+700PS BPF RX CABLE 1EA OUT RDU 850C+700PS TX CABLE 1EA RDM TX 850C+700PS(D) BPF RX CABLE 1EA OUT 1900P+AWS-1 RDU VHF+UHF RDU E-VHF+UHF TX CABLE 1EA RX CABLE 1EA TX CABLE 1EA RX CABLE 1EA BPF RX IN RDM RX IN RDM RX IN RDM RX IN 850C+700LTEC TX CABLE 1EA RDM TX 850C+700LTEC BPF RX CABLE 1EA OUT 20/27 RDM RX IN RDM AWS+1900P RDU Confidential & Proprietary RX RDM RX IN 10 RDU 700LTEF+850C TX CABLE 1EA RDM TX 700LTEF+850C BPF RX CABLE 1EA OUT RDU 700LTEF SISO TX CABLE 1EA RDM TX 700LTEF SISO BPF RX CABLE 1EA OUT RDU 700LTEF SISO TX CABLE 2EA RDM TX 700LTEF MIMO BPF RX CABLE 1EA OUT 1900P DUP TX/RX CABLE 1EA 11 12 13 1900P(MIMO)+ RDM RX IN RDM RX IN RDM RX IN RDM AWS+1900P AWS-1(MIMO) 3.1.7 RDU Specifications Per band Frequency range Standard Unit naming Description TX(MHz) RX(MHz) 700P Public safety 758 to 775 793 to 805 700PS(D) Public safety 763 to 775 788 to 805 iDEN 800P Public safety 851 to 869 806 to 824 Cellular 850C Cellular 869 to 894 824 to 849 Iden 900I SMR 929 to 940 896 to 902 Paging 900 PA Paging 929 to 930 896 to 902 PCS 1900P PCS 1930 to 1995 1850 to 1915 AWS-1 AWS-1 AWS-1 2110 to 2155 1710 to 1755 TDD LTE 2.5TDD TDD 2497.8~2687.4 2497.8~2687.4 VHF Public safety 136 to 174 136 to 174 396 to 450 396 to 450 450 to 512 450 to 512 380 to 434 380 to 434 434 to 496 434 to 496 iDEN Public safety(Band1) UHF Public safety(Band2) 699 to 716 LTE 700LTE Long Term Evolution 728 to 757 777 to 787 Confidential & Proprietary 21/27 700MHz Long Term Evolution Typical Remarks Parameters TX RX Bandwidth 29MHz 28MHz Output power +23dBm +0dBm System Gain 43dB 50dB 50 ohm input and output impedances Total 50 ohm 700MHz Long Term Evolution (MIMO) Typical Remarks Parameters TX RX Bandwidth 29MHz 28MHz Output power +25dBm +0dBm System Gain 45dB 50dB input and output impedances 50 ohm Total 50 ohm 700MHz Public safety Typical Remarks Parameters TX RX Bandwidth 12MHz 12MHz Output power +23dBm +0dBm System Gain 43dB 50dB input and output impedances 50 ohm Total 50 ohm 700MHz Public safety (D Block) Typical Remarks Parameters TX RX Bandwidth 17MHz 17MHz Output power +23dBm +0dBm System Gain 43dB 50dB input and output impedances 50 ohm Confidential & Proprietary 22/27 50 ohm Total 800MHz Public safety Typical Remarks Parameters TX RX Bandwidth 18MHz 18MHz Output power +23dBm +0dBm System Gain 43dB 50dB input and output impedances 50 ohm Total 50 ohm 850MHz Cellular Typical Remarks Parameters TX RX Bandwidth 25MHz 25MHz Output power +23dBm +0dBm System Gain 43dB 50dB input and output impedances 50 ohm Total 50 ohm 900MHz iDEN & Paging Typical Remarks Parameters TX RX Bandwidth 12MHz 6MHz Output power +23dBm +0dBm System Gain 43dB 50dB input and output impedances 50 ohm Total 50 ohm 1900MHz PCS Typical Remarks Parameters TX RX Bandwidth 65MHz 65MHz Output power +26dBm +0dBm System Gain 46dB 50dB Confidential & Proprietary 23/27 Total input and output impedances 50 ohm 50 ohm 1900MHz PCS(MIMO) Typical Remarks Parameters TX RX Bandwidth 65MHz 65MHz Output power +30dBm +0dBm System Gain 50dB 50dB input and output impedances 50 ohm Total 50 ohm 1700MHz&2100MHz AWS-1 Typical Remarks Parameters TX RX Bandwidth 45MHz 45MHz Output power +26dBm +0dBm System Gain 46dB 50dB input and output impedances 50 ohm Total 50 ohm 1700MHz&2100MHz AWS-1(MIMO) Typical Remarks Parameters TX RX Bandwidth 45MHz 45MHz Output power +30dBm +0dBm System Gain 50dB 50dB input and output impedances 50 ohm Total 50 ohm 150MHz VHF Public safety Typical Remarks Parameters TX RX Bandwidth 38MHz 38MHz 136~174MHz Output power +24dBm -4dBm Total System Gain 39dB 50dB Confidential & Proprietary 24/27 input and output impedances 50 ohm 50 ohm 450MHz UHF Public safety Typical Remarks Parameters TX RX 396~450MHz(54MHz) Bandwidth(Band1) 116MHz 116MHz 450~512MHz(62MHz) Band selection 380~434MHz(54MHz) Bandwidth(Band2) 116MHz 116MHz 434~496MHz(62MHz) Band selection Output power +24dBm -4dBm System Gain 39dB 50dB input and output impedances 50 ohm Total 50 ohm 2.5TDD Typical Remarks Parameters TX RX Bandwidth 189.6MHz 189.6MHz Output power +30dBm -20dBm System Gain 50dB 30dB input and output impedances 50 ohm Confidential & Proprietary 25/27 50 ohm Total RSS-GEN, Sec. 7.1.2 – (transmitters) Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée quivalente (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante. RSS-GEN, Sec. 7.1.2 – (detachable antennas) This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur. RF Radiation Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 200 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. Confidential & Proprietary 26/27 RSS-102 RF Exposure L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 200 cm entre la source de radiation (l’antenne) et toute personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur. Warning Statement Antennas must be installed in accordance with FCC 27.50 and SRSP-517. The height of the antenna above average terrain (HAAT) is permitted over 1372m. For different gain antennas refer to the relevant rules. Confidential & Proprietary 27/27
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : shkim Create Date : 2015:07:23 10:35:47+09:00 Modify Date : 2015:07:23 10:35:47+09:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Title : Microsoft Word - 8. SMDR-NH124 User's manual_20150723-HCT Creator : shkim Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:4b0958ce-00b1-43da-8faa-9a7d80aabbbf Instance ID : uuid:e971ed5d-e67a-4e4d-8359-2d62975e5131 Page Count : 27EXIF Metadata provided by EXIF.tools