 Confidential & Proprietary                   61/87 5.2 ODU Installation ODU should be, in any case, put on the top of BIU. This unit gets required power and RF signals from BIU. The following table shows components of ODU:  No.  Unit  Description  Remark Shelf  Including Main Board, 19”,1U  1EA RF Cable  SMA(F) to SMA(F), 400mm  2EA Common Part Signal Cable  2Row(15P_F) to 2Row(15P_M),650mm  1EA Optional Part  DOU  Optical Module with 4 Optic Port  Up to 2EA to be inserted  5.2.1  ODU Shelf Installation ODU is a shelf in around 1U size. Its width is 19” and so this unit should be inserted into a 19” Standard Rack. ODU should be, in any case, put on the top of BIU. BIU should be distant around 1U when the unit is installed.  5.2.2  ODU Power Cabling ODU does not operate independently. The unit should get power from BIU. When you connect 2-column, 15-pin D-SUB Signal cable from BIU and install DOU, LED on the front panel is lit. Through this LED, you can check state values of LD and PD of DOU.  5.2.3  ODU Optic Cabling As optical module shelf, ODU makes electronic-optical conversion of TX signals and then makes optical-electronic conversion of RX signals. ODU can be equipped with up to two DOUs. One DOU supports four optical ports and one optical port can be connected with ROU. Optionally, only optical port 4 can be connected with OEU. As WDM is installed in DOU, the unit can concurrently send and receive two pieces of wavelength (TX:1310nm, RX:1550nm) through one optical core. DOU has SC/APC of optical adaptor type.
 Confidential & Proprietary                   62/87  Figure  5.4  –  Optical cable of SC/ACP Type For optical adaptor, SC/APC type should be used. To prevent the optical access part from being marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt.  5.2.4  Insert DOU to ODU   In an ODU Shelf, up to two DOUs can be installed. DOU module is in Plug in Play type. When you insert DOU in ODU, insert the unit into the left DOU1 slot first. You can be careful as the number is silk printed at the left.   The following figure shows installation diagram of ODU with one DOU inserted in it.   The following figure shows installation diagram of ODU with two DOUs inserted in it.      When you insert DOU into ODU, insert the unit into the left DOU1 slot first. Into unused slot, you need to insert BLANK UNIT in any case.
 Confidential & Proprietary                   63/87 5.2.5  Consumption Power of ODU   ODU gets power from BIU. One ODU can be equipped with up to two DOUs. Depending on how many DOUs are installed, power consumption varies. The table below shows power consumption of ODU:  Part  Unit  Consumption Power Remark ODU_4  DOU 1 EA  13W   ODU_8  DOU 2 EA  26W    5.3 ROU Installation 5.3.1  ROU Enclosure installation ROU is designed to be water- and dirt-proof. The unit has the structure of One-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of NEMA4. ROU can be mounted into either of a 19” Standard Rack or on a Wall.   Basically, ROU has both of a Wall Mount Bracket and a Rack Mount Bracket. Depending on the use of the Rack Mount Bracket, the bracket can be removed. The following shows dimension of the fixing point for the Wall Mount Bracket.  Figure 5.5 – How to install ROU
 Confidential & Proprietary                   64/87  Figure  5.6  –  Dimension used to install ROU on the WALL   ROU Wall Mount Installation Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it. For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure.   Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.
 Confidential & Proprietary                   65/87   Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 12 M5 Wrench Bolts in total except bolts used for the fixing groove.   ROU Rack Mount Installation Like other units, ROU is designed to be inserted into a rack. The unit occupies around 13U of space except cable connection.
 Confidential & Proprietary                   66/87   ROU component ROU has the following components: No.  Unit  Description  Remark Enclosure  Including Rack & Wall cradle  1EA RCPU -  1EA R_OPTIC  With SC/ACP adaptor 1EA RPSU  Alternative DC-48V or AC 120V    1EA Multi-Plexer -  1EA Common Part Power Cable  - MS Connector with 3 hole to AC 120 plug(AC) - MS Connector with 2 lug termination(DC)   Optional Part  RDU+BPF  800PS,800PS+900I+Paging,850C,850C+700PS, 1900P+ AWS-1 RDU Up to 3EA to be inserted  Basically, the common part of ROU should have an enclosure and it is equipped with RCPU to inquire and control state of each module, R_OPTIC to make both of electronic-optical and optical-electronic conversions, RPSU to supply power for ROU and a Multi-Plexer to help share multiple TX/RX signals through one antenna. It should have Power Cable for external rectifier or to supply required power.
 Confidential & Proprietary                   67/87 In addition, RDU can be inserted and removed to provide service for desired band (Optional).  5.3.2  ROU Power Cabling ROU supports both of DC-48V and AC120V of input power. As RPSU for DC-48 and RPSU for AC120V are separated from each other, you need to select one of them in case of purchase order. RPSU for DC -48V and RSPU for AC 120V have the same configuration and capacity while each of the units uses different input voltage from each other.  The following figure shows configuration of RPSUs for DC -48V and AC 120V.
 Confidential & Proprietary                   68/87  Lug Naming  RPSU Terminal naming MC Connector numbering  AC  DC  AC  DC Remark A AC_H -48V AC-H  -48V   B AC_N GND AC-N  IN_GND   C GND DC NC FG  FG    Check if the connection is the same as one seen in the table above and make sure to turn the power ON.  5.3.3 Optical Cabling ROU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes electronic- optical conversion of RX signals. ROU has one optical module in it. As WDM is installed in the R_OPTIC module, two pieces of wavelength (TX:1310nm, RX:1550nm) can be sent/received with one optical core at the same time. ROU has SC/APC of optical adaptor type. For optical adaptor, SC/APC type can be used. To prevent the optical access part from being marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt.
 Confidential & Proprietary                   69/87 Optical cables should be inserted into Optic Port outside of ROU. Using an optical slack devices in ROU, you need to coil around one or two roll of cables to be connected with the optical adaptor of ROPTIC. At this time, curvature of the optical cable should be at least 10Ø to prevent insertion loss from being increased. Through GUI, check if PD value of ROPTIC is in a tolerable range (+4~-1dBm).  5.3.4  Insertion of RDU ROU has slots to enable up to three RDU modules to be inserted into the unit. You can insert a RDU into any slot. It is not possible to provide services with a RDU module alone; you need to connect the module with Cavity BPF in any case. The table below shows types of RDU and CAVITY BPF: Multiplexer Interface No  Unit naming  Cavity BPF  RF CABLE  TX  RX 1  RDU 800PS  800PS BPF  TX CABLE 1EA RX CABLE 1EA  BPF OUT  RDM RX IN 2  RDU 850C  850C BPF  TX CABLE 1EA RX CABLE 1EA BPF TX OUT  BPF RX IN 3  RDU 1900P+AWS-1  1900P DUP  TX/RX CABLE 1EA  RDM AWS+1900P 5  RDU 800PS+900I+PA 800PS+900I+PA BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT  RDM RX IN 6  RDU 850C+700PS 850C+700PS BPF TX CABLE 1EA RX CABLE 1EA RDM TX OUT  RDM RX IN The following describes how to install RDU in ROU.  How to install RDU 800PS Ass’y The following components are required: No.  Unit  Description  Remark 1  RDU 800PS  RF Module   2 800PS BPF  BPF   3  800PS TX RF CABLE  SMA(M) to SMA(M), 360mm   4  800PS RX RF CABLE  SMA(M) to SMA(M), 410mm
 Confidential & Proprietary                   70/87   Combine ①RDU 800PS with 800PS BPF (As it is a plug type, push the unit to combine with BPF.)  In②sert the combined 800PS+850C BPF Ass’y into any slot of ROU.  Combination point of 800PS+800PS BPF Ass’y of the multiplexer③  Interface Point Multiplexer Port naming  800PS RDU  800PS BPF  Remark 800PS+900I+PA TX  -  TX OUT   800PS+900I+PA RX  RX IN  -
 Confidential & Proprietary                   71/87 How to RDU install 850C Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 850C  RF Module   2 850C BPF  BPF   3  850C TX RF CABLE  SMA(M) to SMA(M), 310mm   4  850C RX RF CABLE  SMA(M) to SMA(M), 310mm    ① Combine 850C RDU with 850C BPF (As it is a plug type, push the unit to combine with BPF.)  Insert the combined 850C+850C BPF Ass’y into any slot of ROU.②  Combination point of 850C+850C BPF Ass’y of the multiplexer③   Interface Point Multiplexer Port naming  850C RDU  850C BPF  Remark 850C TX  -  TX OUT   850C RX  -  RX IN
 Confidential & Proprietary                   72/87  How to install RDU 800PS+900I+PA Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 800PS+900I+PA  RF Module   2 800PS+900I+PA BPF  BPF   3  800PS+900I+PA TX RF CABLE  SMA(M) to SMA(M), 460mm   4  800PS+900I+PA RX RF CABLE  SMA(M) to SMA(M), 380mm     Combine ①RDU 800PS+900I+PA with 800PS+900I+PA BPF (As it is a plug type, push the unit to combine with BPF.)  Insert the combined ②800PS+900I+PA BPF Ass’y into any slot of ROU.  Combination point of ③800PS+900I+PA BPF Ass’y of the multiplexer
 Confidential & Proprietary                   73/87  Interface Point Multiplexer Port naming  800PS+900I+PA RDU  800PS+900I+PA BPF Remark 800PS+900I+PA TX  TX OUT  -   800PS+900I+PA RX  RX IN  -    How to install RDU 850C+700PS Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 850C+700PS  RF Module   2 850C+700PS BPF  BPF   3  850C+700PS TX RF CABLE  SMA(M) to SMA(M), 470mm   4  850C+700PS RX RF CABLE  SMA(M) to SMA(M), 400mm     Combine ①RDU 850C+700PS with 850C+700PS BPF (As it is a plug type, push the unit to combine with BPF.)  Insert the combined ②850C+700PS BPF Ass’y into any slot of ROU.  Combination point of ③850C+700PS BPF Ass’y of the multiplexer
 Confidential & Proprietary                   74/87  Interface Point Multiplexer Port naming  850C+700PS RDU 850C+700PS BPF  Remark 850C+700PS TX  TX OUT  -   850C+700PS RX  RX IN  -    How to install RDU 1900P+AWS-1 Ass’y   The following components are required: No.  Unit  Description  Remark 1  RDU 1900P+AWS-1  RF Module   2 1900P+AWS-1 BPF  BPF   3  1900P+AWS-1 RF CABLE  SMA(M) to SMA(M), 390mm   4  1900P+AWS-1 RF-01  SMA(M) to SMA(M)  Semirigid   Combine ①RDU 1900P+AWS-1 with 1900P  BPF (As it is a plug type, push the unit to combine with BPF.)
 Confidential & Proprietary                   75/87  Connect BPF 1900P port with 1900P port of 1900P RDU through ②1900P+AWS-1 RF-01 RF CABLE.   Insert the combined ③1900P+AWS-1 BPF Ass’y into any slot of ROU.  Combination point of ④1900P+AWS-1 BPF Ass’y of the multiplexer  Interface Point Multiplexer Port naming  1900P+AWS-1 RDU  1900P BPF  Remark AWS-1+1900P COM  1900P+AWS  -       You cannot insert the same module and band into MULTIPLEXER port at the same time. For example, you are not supposed to insert both of 800PS RDU and 800PS+900I+PA RDU into ROU at the same time. In the same way, you cannot concurrently insert both of 850C RDU and 850C+700PS RDU into ROU.   Information of LED at the front RDU  RDU has the structure of enabling a random RDU to be inserted into three slots.   ROU can be equipped with a total of three RDUs. If only one RDU is inserted into a slot and the other slots ramian reserved, you need to insert BLANK cards into the other slots. When RDU is inserted into ROU, LED of the front panel shows the following information:
 Confidential & Proprietary                   76/87      Up to three RDUs can be inserted. If one or two units are used, then you need to terminate the unused slot of RDU with a BLANK card.   5.3.5  Consumption of RDU The following table shows power consumption of RDU: Part  Unit  Consumption Power  Remark Enclosure RCPU ROPTIC RPSU Common Part Multiplexer 17W  RDU  RDU 800PS  39W   LED  Description   Power is not supplied ON   Power is supplied.  Normal Operation ALM  Abnormal Operation
 Confidential & Proprietary                   77/87 800PS  49W  900I+PA HPA OFF 900I+PA 72W 800PS HPA OFF RDU 800PS+900I+Paging FULL  79W  Both HPA ON RDU 850C  39W   850C 49W 700PS HPA OFF 700PS  58W  850C HPA OFF RDU 850C+700PS FULL  93W  Both HPA ON 1900P  46W  AWS-1 HPA OFF AWS-1  46W  1900P HPA OFF  RDU 1900P+AWS-1 FULL  68W  Both HPA ON For power consumption of ROU, the common part consumes 17W. Depending on the quantity of each RDU, you can add overall power consumption of ROU. Only, in case of Dual-Band signals, power consumption is calculated respectively when HPA of the other party is turned OFF and two HPA devices are turned ON. Note that when you calculate Power Budget.  5.4 OEU Installation OEU is used to expand ROU in Campus Site. OEU is located at a Remote Closet. As it can be equipped with up to two DOUs, you can expand a total of eight ROUs. 5.4.1  OEU Shelf installation OEU is a shelf in around 2U size. Its width is 19” and so this unit should be inserted into a 19” Standard Rack. OEU is in a Remote Closet, providing optical ports of ROU. The following table shows power consumption of OEU: No.  Unit  Description  Remark Shelf  Including EWDM,ERF,EPSU,ECPU,  19”,2U  1EA Common Part Power Cable  -48Vdc Input with two lug terminal    1EA
 Confidential & Proprietary                   78/87 Optional Part  DOU  Optical Module with 4 Optic Port  Up to 2EA to be inserted  5.4.2  OEU Power Cabling The input power of OEU is DC -48V. You need to connect DC cable with the Terminal Block seen at the rear of OEU. Terminal  Color of cable  Description  Remark -48V  Blue color  Input range: -42 ~ -56Vdc   NC Not Connected     GND Black color     Before connecting the power terminal, you need to connect "+" terminal of Multi Voltage Meter probe with the GND terminal and then connect "–" terminal with -48V to see if “-48Vdc” voltage is measured. After the check, connect the power terminal through the terminal seen below.      Note that OEU does not operate if the "+" terminal and the "–" terminal of the -48V power are not inserted into the accurate polarity.     5.4.3  OEU Optic Cabling OEU is connected with upper ODU. With DOU inserted in it, the unit is connected with ROU.
 Confidential & Proprietary                   79/87 As OEU has a shelf with EWDM in it, the unit makes electronic-optical conversion of TX signals from ODU and makes optical-electronic conversion of RX signals. In addition, OEU can be equipped with up to two DOUs. One DOU supports four optical ports and one optical port can be connected with ROU. With WDM in DOU, the unit can concurrently send/receive two pieces of wavelength (TX:1310nm, RX:1550nm) through one optical core. DOU has SC/APC of optical adaptor type.  Figure  5.7  –  Optical cable of SC/ACP Type For optical adaptor, SC/APC type should be used. To prevent the optical access part from being marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt.  5.4.4  Insert DOU to OEU Into OEU Shelf, up to two DOUs can be inserted. DOU module is in Plug in Play type. When you insert DOU in OEU, insert the unit into the top DOU1 slot first. You can be careful as the number is silk printed at the left.   The following figure shows installation diagram of OEU with one DOU inserted in it.  The following figure shows installation diagram of OEU with two DOUs inserted in it.
 Confidential & Proprietary                   80/87      When you insert DOU into OEU, insert the unit into the top DOU1 first. For unused slots, you nedd to install BLANK UNIT into them.  5.4.5  Consumption Power of OEU   OEU has -48V DC Power supply in it. ODU can be equipped with up to two DOUs. Depending on the quantity of DOU, power consumption is varied.   The following table shows power consumption of OEU: Part  Unit  Consumption Power Remark Shelf EWDM ERF Common Part EPSU 12W  OEU_4  DOU 1 EA  23W   OEU_8  DOU 2 EA  33W    5.5 System Operation and Alarm Status This section describes operation of SMDR-NH124. It deals with procedures and operations for normal system operation after installation. It also describes operations per unit and interworking methods.
 Confidential & Proprietary                   81/87 5.5.1  System setting and operation
 Confidential & Proprietary                   82/87 1.  Perform system setting shown in the above configuration 2.  For downlink performance test, using signal analyzer, provide -20dBm/composite power input to BIU, and set system gain to maximum level. 3.  Connect all the unit like above configuration and turn the power on for all units and make sure all the alarms in normal status by GUI monitoring. 4.  Using spectrum analyzer and optic power meter, check output power for each unit as described in the above configuration and check whether the output powers are in the normal range. 5.  For uplink performance test, using signal analyzer, provide -50dBm/band to remote unit 6.  Connect all the unit like above configuration and turn the power on for all units and make sure all the alarms in normal status by GUI monitoring. 7.  Using spectrum analyzer and optic power meter, check output power for each unit as described in the above configuration and check whether the output powers are in the normal range. 8.  Temporarily, turn the power off for all units. 9.  Using spectrum analyzer, measure the input range from BTS/BDA if the range is between -20dBm and +10dBm. 10. If the level exceeds the range, need to connect an attenuator with the front end of BIU input to adjust the level in the corresponding range. 11. turn the power on for all units and make sure all the alarms in normal status by GUI monitoring. 12. For system optimization, through GUI, adjust the all the parmaters such as ALC, AGC, Shut down level, and offset values.
 Confidential & Proprietary                   83/87  5.5.2 BIU Alarms Item  Description 1. MDBU LED  LED to show whether MDBU is installed and gets faulty 2. RF Monitor Port  20dB Coupling compared with TX Input Level 20dB Coupling compared with RX Output Level   3. Alarm LED & Reset  Communication state with devices, alarm status of the system and reset switch 4. NMS(RS-232C)  RS-232C port for communication and diagnosis of devices through PC/laptop 5. NMS(Ethernet)  Ethernet port for upper network 6. Pwr Test Port & ALM Output DC power test port and ALM LED to show abnormal state, if any 7. Power switch  Power ON/OFF switch  LED information Unit  LED  Indicates ON    Green: MDBU is normally power-supplied.   Green: MDBU is normal. MDBU ALM   Red: MDBU is abnormal; check the alarm through RS-232C. ON   Green: MCPU is normally power-supplied. TXD   Green flicker: TX signals are transmitted to communicate with ROU. RXD   Green flicker: RX signals are received from ROU.  Green: BIU system is normal. MCPU ALM  Red: BIU system is abnormal; check the alarm through RS-232C. ON    Green: BIU is connected with power and MPSU works normally.   Green: DC output is normal. MPSU ALM  Red: DC output is abnormal.
 Confidential & Proprietary                   84/87 5.5.3 ODU Alarms  Item  Description 1,2  LED indicator to check DOU module state to see if it is abnormal  LED information Unit  LED  Indicates  Green: Laser Diode is normal. LD  Red: Laser Diode is abnormal.  Green: Photo Diode of optical port 1 is normal. PD1  Red: Photo Diode of optical port 1 is abnormal; check optical cables. Green: Photo Diode of optical port 2 is normal. PD2  Red: Photo Diode of optical port 2 is abnormal; check optical cables. Green: Photo Diode of optical port 3 is normal. PD3  Red: Photo Diode of optical port 3 is abnormal; check optical cables. Green: Photo Diode of optical port 4 is normal. DOU1,2 PD4  Red: Photo Diode of optical port 4 is abnormal; check optical cables.
 Confidential & Proprietary                   85/87  5.5.4  OEU Alarms Item  Description 1.EWDM LED  LED indicator to check EWDM state to see if it is abnormal 2.DOU LED  LED indicator to check DOU module state to see if it is abnormal 3.System LED and Reset  Communication state with devices, alarm status of the system and reset switch 4. NMS(RS-232C port)  RS-232C port for communication and diagnosis of devices through PC/laptop  LED information Unit  LED  Indicates  Green: Laser Diode is normal. LD  Red: Laser Diode is abnormal.  Green: Photo Diode is normal. EWDM PD  Red: Photo Diode is abnormal; check optical cables.  Green: Laser Diode is normal. LD  Red: Laser Diode is abnormal.  Green: Photo Diode of optical port 1 is normal. PD1  Red: Photo Diode of optical port 1 is abnormal; check optical cables. Green: Photo Diode of optical port 2 is normal. PD2  Red: Photo Diode of optical port 2 is abnormal; check optical cables. Green: Photo Diode of optical port 3 is normal. PD3  Red: Photo Diode of optical port 3 is abnormal; check optical cables. Green: Photo Diode of optical port 4 is normal. DOU1,2 PD4  Red: Photo Diode of optical port 4 is abnormal; check optical cables.System  ON   Green: ECPU is normally power-supplied.
 Confidential & Proprietary                   86/87 TXD1   Green flicker: TX signals are sent to communicate with BIU. RXD1   Green flicker: RX signals are received from BIU. TXD2   Green flicker: TX signals are sent to communicate with ROU. RXD2   Green flicker: RX signals are received from ROU.  Green: OEU system is normal.  ALM  Red: OEU system is abnormal; check the alarm through RS-232C.  5.5.5  ROU Alarms No.  Unit  Description  Remark1 RDU+BPF Remote Drive Unit Filter and high amplify TX signals; Filter and amplify RX signals; Remove other signals through BPF  2 RPSU Remote Power Supply Unit Input power: DC -48V, Output power: 27V,9V, 6V For 120V input of AC/DC; For -48V input of DC/DC  3 R-OPTIC Remote Optic Make RF conversion of TX optical signals; Convert RX RF signals into optical signals; Compensates optical loss Communicates with BIU/OEU though the FSK modem  4 RCPU Remote Central Processor Unit Controls signal of each unit Monitors BIU/ODU/OEU status through FSK modem communication  5 Multiplexer Multiplexer Combine TX signals from 3 RDUs; Distribute RX signals to 3 RDUs; Enable you to use a single antenna port
 Confidential & Proprietary                   87/87 6 Enclosure Enclosure to satisfy NEMA4;   Enable Wall/Rack Mount; Check if the system is normal, through the front panel LED  7 SIU  System Interface Unit Distribute power and signals of each module    LED information Unit  LED  Indicates ON   Green: ECPU is normally power-supplied.  Green: Laser Diode is normal. LD  Red: Laser Diode is abnormal.  Green: Photo Diode is normal. PD  Red: Photo Diode is abnormal; check optical cable. TXD  Green flicker: TX signals are transmitted to communicate with BIU/OEU RXD   Green flicker: RX signals are received from BIU/OEU.  Green: OEU system is normal. System ALM  Red: OEU system is abnormal; check the alarm through RS-232C.