Class B_SOLiD Responder_User Manual_Rev.1
User Manual of SRDR-33-7080-A-FN SOLiD Responder Public Safety 700/800 MHz Digital Repeater SRDR-33-7080-A-FN User Manual Version 1.0 8/8/2017 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 1 / 70 User Manual of SRDR-33-7080-A-FN Preface The user documentation set of SOLiD Responder consists of following main statements: • SOLiD Responder SRDR-33-7080-A-FN User Manual: Precautions and instructions for installing and setting up SRDR-33-7080-A-FN. Copyright All rights are reserved ©2017 SOLiD. Confidential and proprietary. Information contained in this document is company private to SOLiD and should not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of SOLiD. Trademark Information No right, license, or interest to SOLiD Responder trademarks is granted here. By using this document, you agree not to assert any right, license, or interest with respect to such trademark. Other product names mentioned in this manual are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Disclaimer of Liability The contents of this document, including graphics and screenshots, are current as of the date of publication. SOLiD reserves the right to change the contents without prior notice. In no event shall SOLiD be liable for any damages resulting from loss of data, loss of use or loss of profits. SOLiD further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Getting Support and Providing Feedback To authorize technical support or to establish a return authorization for defective units, make sure you have the SOLiD serial numbers available. Serial numbers are located on the bottom of the product, as well as on the box in which it was delivered. Contact SOLiD for additional support information: ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 2 / 70 User Manual of SRDR-33-7080-A-FN Contact Information SOLiD Gear, Inc. Headquarters Address: 800 Klein Road, Suite 200, Plano, TX 75074 Phone: 888.409.9997 Email for support issues: support@solid.com Web site: www.solid.com Revision History Revision Number Issue Date Changes 1.0 Aug 8th, 2017 Initial Release ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 3 / 70 User Manual of SRDR-33-7080-A-FN Contents General Information .............................................................................................. 10 1.1 Safety Notices ............................................................................................................................. 10 1.2 FCC Notices ................................................................................................................................ 12 1.3 Industry Canada(IC) Notices ....................................................................................................... 14 1.4 Antenna Installation Notices ........................................................................................................ 16 1.4.1 Antenna Requirements .................................................................................................. 16 1.4.2 Donor Antenna Requirements ....................................................................................... 16 1.4.3 Service Antenna Requirements ..................................................................................... 16 Product Overview .................................................................................................. 17 2.1 Introduction .................................................................................................................................. 17 2.2 Main Features ............................................................................................................................. 17 2.3 Ordering Information ................................................................................................................... 18 2.4 Signal Flow .................................................................................................................................. 19 2.5 Description of Modules ................................................................................................................ 20 2.5.1 Integrated PSU .............................................................................................................. 20 2.5.2 Power Amplifier Unit (PAU) ........................................................................................... 20 2.5.3 Digital Unit (DU) ............................................................................................................. 20 2.5.4 Radio Frequency Unit (RFU) ......................................................................................... 20 2.5.5 CPU ............................................................................................................................... 20 2.5.6 Multiplexer...................................................................................................................... 21 2.5.7 Signal Analysis Module (SAM) ...................................................................................... 21 2.6 External Interface ........................................................................................................................ 22 2.7 Operation ..................................................................................................................................... 23 2.7.1 Classes and Passbands Types ..................................................................................... 23 2.7.2 Procedure to Choose Passband .................................................................................... 26 2.7.3 Automatic Shutdown of Amplifiers ................................................................................. 30 Installing the SOLiD RESPONDER ....................................................................... 32 3.1 Overview of the Installation Procedure ....................................................................................... 32 3.2 Location Installation Site ............................................................................................................. 33 3.3 3.2.1 Product Dimension ........................................................................................................ 33 3.2.2 Installation Environment ................................................................................................ 34 Unpacking and Package Contents .............................................................................................. 34 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 4 / 70 User Manual of SRDR-33-7080-A-FN 3.4 3.4.1 Mounting Method ........................................................................................................... 35 3.4.2 Installation the Wall Mount Bracket ............................................................................... 36 3.4.3 Rack Mount Installation ................................................................................................. 36 3.5 Grounding .................................................................................................................................... 36 3.6 Antenna Connections and Guidelines ......................................................................................... 38 3.7 3.8 Mounting the Product .................................................................................................................. 35 3.6.1 Donor Antenna Installation Guidelines .......................................................................... 38 3.6.2 Indoor Antenna Installation Guidelines .......................................................................... 38 3.6.3 RF Cable Installation Guidelines ................................................................................... 38 3.6.4 Connecting Antennas .................................................................................................... 38 Connecting Power Cables and Power-up ................................................................................... 39 3.7.1 Integrated PSU .............................................................................................................. 39 3.7.2 Power Redundancy ....................................................................................................... 39 3.7.3 AC Power Cabling ......................................................................................................... 40 3.7.4 DC Power Cabling ......................................................................................................... 41 3.7.5 Power Up ....................................................................................................................... 41 Connecting NFPA Alarms ........................................................................................................... 42 3.8.1 Choose the alarms to be monitored .............................................................................. 42 3.8.2 Select the type of external alarms ................................................................................. 42 3.8.3 Connect cable to the alarm box ..................................................................................... 43 3.8.4 Verify the state of connection ........................................................................................ 43 Setup and Commissioning ................................................................................... 44 4.1 Overview of the Commissioning Procedure ................................................................................ 44 4.2 Connecting the GUI to the Product ............................................................................................. 45 4.3 4.2.1 Network Information of GUI ........................................................................................... 45 4.2.2 Log in GUI ...................................................................................................................... 46 4.2.3 GUI Main Screen ........................................................................................................... 46 Configuring Operation Mode of the Product ............................................................................... 48 4.3.1 Operation Mode Window ............................................................................................... 48 4.3.2 Changing Operation Mode............................................................................................. 49 4.3.3 Filter Mode ..................................................................................................................... 49 4.3.4 Echo Cancellation .......................................................................................................... 49 4.3.5 Power Supply Configuration .......................................................................................... 49 4.3.6 AMP Shutdown function ................................................................................................ 50 4.3.7 Summary........................................................................................................................ 50 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 5 / 70 User Manual of SRDR-33-7080-A-FN 4.4 Setup Channel Configuration & RF parameters ......................................................................... 51 4.4.1 Input the information of service channels ...................................................................... 51 4.4.2 Setup Parameters of Digital Filter .................................................................................. 51 4.4.2.1 Pre-Configured Filter Mode ............................................................................................... 51 4.4.2.2 36 Channelized Filters ....................................................................................................... 53 4.5 4.6 4.5.1 Monitor Downlink Input Power ....................................................................................... 55 4.5.2 Measure the isolation between donor antenna and service antenna ............................ 55 4.5.3 Evaluate isolation value & reconfigure the antenna installation .................................... 55 4.5.4 Test coverage area ........................................................................................................ 56 4.5.5 Verify UL gain and Performs test calls .......................................................................... 56 SNMP traps & Time Settings ...................................................................................................... 57 Administrations ..................................................................................................... 58 5.1 Viewing General Information ....................................................................................................... 58 5.2 Alarm Remedy............................................................................................................................. 59 5.3 Alarm Log .................................................................................................................................... 61 5.4 Isolation Measurement & Tune-up .............................................................................................. 55 5.3.1 Alarm History ................................................................................................................. 61 5.3.2 Alarm Mask / Shutdown ................................................................................................. 62 Firmware Upgrade....................................................................................................................... 63 Appendix ................................................................................................................ 64 6.1 Environmental Specification ........................................................................................................ 64 6.2 Radio Frequency Specification ................................................................................................... 65 6.3 Digital Filter Specification ............................................................................................................ 66 6.3.1 Public Safety 700 MHz Band–Selective (Class B) ........................................................ 66 6.3.2 Public Safety 800 MHz Band –Selective (Class B) ....................................................... 66 6.3.3 Public Safety 700 & 800 MHz Channel–Selective (Class A) ......................................... 67 6.4 Power Supply Specification ......................................................................................................... 68 6.5 Mechanical Specification ............................................................................................................. 69 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 6 / 70 User Manual of SRDR-33-7080-A-FN List of Figures Figure 1. FCC Part 90 Class Information in the GUI .............................................................................. 12 Figure 2. Signal Flow of SRDR-33-7080-A-FN ........................................................................................... 19 Figure 3. Inner View of the SRDR-33-7080-A-FN ...................................................................................... 20 Figure 4. External Connectors .................................................................................................................... 22 Figure 5. The Spectrum of M701 ................................................................................................................ 24 Figure 6. The Spectrum of M702 ................................................................................................................ 24 Figure 7. The Spectrum of M703 ................................................................................................................ 24 Figure 8. The Spectrum of M801 ................................................................................................................ 24 Figure 9. The Spectrum of M802 ................................................................................................................ 25 Figure 10. The Spectrum of M803 .............................................................................................................. 25 Figure 11. The Spectrum of M036 excluding FirstNet ................................................................................ 25 Figure 12, The Spectrum of M036 including FirstNet ................................................................................. 25 Figure 13. 3 times Failure in Shutdown Algorithm Type 1 .......................................................................... 30 Figure 14. 2 times Failure in Shutdown Algorithm Type 1 .......................................................................... 30 Figure 15. Shutdown Algorithm Type 2 ....................................................................................................... 31 Figure 16. Dimensions of SRDR-7080-A-FN .............................................................................................. 33 Figure 17. Mount Bracket for Wall and Rack .............................................................................................. 35 Figure 18. Dimensions used to install Product on the Wall ........................................................................ 35 Figure 19. The Location of Ground Lug ...................................................................................................... 37 Figure 20. Information of Terminal .............................................................................................................. 37 Figure 21. Connection for AC-UPS site ...................................................................................................... 39 Figure 22. Connection for DC-UPS site ...................................................................................................... 39 Figure 23. Connections with AC & Batteries ............................................................................................... 40 Figure 24. AC Cable Drawing ..................................................................................................................... 40 Figure 25. DC Cable Drawing ..................................................................................................................... 41 Figure 26. Relay Output Cable Drawing ..................................................................................................... 43 Figure 27. External Alarm Emulator ............................................................................................................ 43 Figure 28. GUI Port of SOLiD Responder ................................................................................................... 45 Figure 29. Login Window ............................................................................................................................ 46 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 7 / 70 User Manual of SRDR-33-7080-A-FN Figure 30. Main Screen of GUI ................................................................................................................... 46 Figure 31. System Operation Mode Window .............................................................................................. 48 Figure 32. Power Supply Configuration ...................................................................................................... 49 Figure 33. AMP Shutdown Function ........................................................................................................... 50 Figure 34. Summary of Selecting the Operation Modes ............................................................................. 50 Figure 35. Service Channels Window ......................................................................................................... 51 Figure 36. Pre-Configured Filter Mode Window.......................................................................................... 52 Figure 37. Channelized Filter Mode Window .............................................................................................. 53 Figure 38. Isolation Measurement Window................................................................................................. 55 Figure 39. SNMP Configuration .................................................................................................................. 57 Figure 40. System Information Window ...................................................................................................... 58 Figure 41. Example of Alarm Remedy ........................................................................................................ 60 Figure 42. System Log ................................................................................................................................ 61 Figure 43. Alarm Mask / Shutdown ............................................................................................................. 62 Figure 44. Upgrade / Reset ......................................................................................................................... 63 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 8 / 70 User Manual of SRDR-33-7080-A-FN List of Tables Table 1. License Descriptions ..................................................................................................................... 18 Table 2. Unit Functions ............................................................................................................................... 21 Table 3. Passbands of Class A Device ....................................................................................................... 23 Table 4. Passbands of Class B Device ....................................................................................................... 23 Table 5. Passband Types ........................................................................................................................... 23 Table 6. Mechanical Specification .............................................................................................................. 33 Table 7. Packing List of the SRDR-33-7080-A-FN ..................................................................................... 34 Table 8. Power Supply Specification .......................................................................................................... 39 Table 9. AC Port Pin Description ................................................................................................................ 40 Table 10. DC Port Pin Description .............................................................................................................. 41 Table 11. NFPA Alarm Connection upon the Power Supply configuration ................................................. 42 Table 12. IP address of SOLiD Responder ................................................................................................. 45 Table 13. Access Information to AP ............................................................................................................ 45 Table 14. Description of Main Menu ........................................................................................................... 47 Table 15. Description of Operation Mode Items ......................................................................................... 48 Table 16. Pre-configured Filter Parameters ................................................................................................ 52 Table 17. 36 Channelized Filter Parameters .............................................................................................. 53 Table 18. Parameters of Time Setting ........................................................................................................ 57 Table 19. Description of System Information .............................................................................................. 58 Table 20. Description of Alarms .................................................................................................................. 59 Table 21. Description of Terms in the Alarm Mask ..................................................................................... 62 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 9 / 70 User Manual of SRDR-33-7080-A-FN General Information 1.1 Safety Notices “Only qualified personnel should handle the equipment. Any person involved in installation or service of the equipment should understand and follow these safety guidelines.” General Caution SOLiD assumes no liability for the customer’s or user’s failure to comply with these requirements: • • Explosive atmospheres - To avoid explosion or fire, do not operate this equipment in the presence of flammable gases or fumes. Lightning danger - Do not install or make adjustments to this equipment during an electrical storm. Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation. Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the equipment. When working with equipment outdoors, make sure to fasten the door or cover securely in an open state to prevent the door from slamming shut by the wind. Use this eqipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. Any local regulations are to be followed when operating repeaters. Hot Burn Injury Due to the power dissipation, the equipment may reach a very high temperature. Be careful not to touch the heat-sink part or the hot parts inside and outside. Since the temperature goes lower slowly, pay caution after putting off the equipment. Power Supply Precaution In case of connection to the sealed lead-acid batteries, this equiment is intended for installation in restricted access areas. A restricted access area is an area to which access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and which is controlled by the authority responsible for the location. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 10 / 70 User Manual of SRDR-33-7080-A-FN Only service personnel or skilled person should handle the connection procedure between the product and the batteries including auxillary accessories concerning the power supply sources. This power of this system should be supplied with the wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device Grounding Signal Booster, feeders, donor antenna, service antenna and auxiliary equipment (splitters, tabs, .etc) are required to be bonded to protective grounding using the bonding stud or screw provided with each unit. Dangerous Electric Shock Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the main power supply off prior to any work in such a repeater. Electrostatic Discharge Static electricity means no risk of personal injury but it can severely damage essential parts of the Signal Parts on the printed circuit boards as well as other parts in the Signal Booster are sensitive to electrostatic discharge. Never touch printed circuit boards or uninsulated conductor surfaces unless absolutely necessary. If you must handle printed circuit boards or uninsulated conductor surfaces, use ESD protective equipment, or first touch the Signal Booster chassis with your hand and then do not move your feet on the floor. Never let your clothes touch printed circuit boards or uninsulated conductor surfaces. Disposal of Electric and Electronic Waste Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with unsorted waste. Please contact your local recycling authority for disposal of this product. Dispose of used batteries according to the instructions in accordance with legal laws. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 11 / 70 User Manual of SRDR-33-7080-A-FN 1.2 FCC Notices FCC Part 90 statement This equipment complies with Title 47 CFR Parts 90. This is a 90.219 Class B device. WARNING: This is a 90.219 Class B device. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signalboosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Home/personal use are prohibited. The installation procedure must result in the signal booster complying with FCC/ISED requirements 90.219(d)/ RSS-131 Sec.6.3 & 6.4. In order to meet FCC/ ISED requirements, it may be necessary for the installer to reduce the UL and/or DL output power for certain installations. Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor‐ only restrictions is prohibited. If all the passbands are no wider than 75 KHz, the equipment will be Class A device. Otherwise it is Class B device. User can also check FCC part 90 Class from the System Information window. Figure 1. FCC Part 90 Class Information in the GUI If you are unsure, contact your provider. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 12 / 70 FCC Part 15 statement User Manual of SRDR-33-7080-A-FN This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may notcause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could “void” the user's authority to operate this equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Radiofrequncy Radiation Exposure Limits This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 200 cm during normal operation. This device must not be co-located or operating in conjunction with any other antenna or transmitter. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 13 / 70 User Manual of SRDR-33-7080-A-FN 1.3 Industry Canada(IC) Notices This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. Son exploitation est autorisée aux deux conditions suivantes: (1) .il ne doit pas produire de brouillage; et (2) il doit accepter tout brouillage radioélectrique subi, même si celui-ci est susceptible d’en compromettre le fonctionnement. RSS-GEN, Sec. 7.1.2 – (transmitters) Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée quivalente (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante. RSS-GEN, Sec. 7.1.2 – (detachable antennas) This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur. RSS-102 RF Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 200 cm between the radiator and your ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 14 / 70 User Manual of SRDR-33-7080-A-FN body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 200 cm entre la source de radiation (l’antenne) et toute personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur. RSS-131 Section 5.3 The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. a. The nominal passband gain (dB): 95dB maximum b. The nominal bandwidth: 12.5KHz – 10MHz c. The rated mean output power: 33 dBm per each band maximum d. The input and output impedances: 50 ohm, 50 ohm ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 15 / 70 User Manual of SRDR-33-7080-A-FN 1.4 Antenna Installation Notices 1.4.1 Antenna Requirements The installation procedure must result in the signal booster complying with FCC requirements 90.219(d). In order to meet FCC requirements 90.219(d), it may be necessary for the installer to reduce the UL and/or DL output power for certain installations. FCC regulation mandate that the ERP of type B signal boosters should not exceed 5W. Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor‐only restrictions is prohibited. Only 50 ohm rated antennas, cables and passive equipment shall be used with this equipment. Any device attached to this equipment not meeting this standard may cause degradation and unwanted signals in the bi-directional system. All components connected to this device must operate in the frequency range of this device. 1.4.2 Donor Antenna Requirements Maximum Service Antenna Gain is calculated by the below formula. [ERP] – [nominal output power] – [cable Loss] Yagi or silmilar type: Directional antenna with a sharp beam, at maximum 17 dBi At minimum cable loss is 5 dB Example of the available antenna specification EIRP = 27 dBm (UL output power) - 5 dB (Cable Loss) + 17 dBi (Antenna gain) = 39 dBm ERP = EIRP – 2.15 dB = 39 – 2.15 = 36.85 dBm < 37 dBm (FCC limit) 1.4.3 Service Antenna Requirements Maximum Service Antenna Gain is calculated by the below formula. [ERP] – [nominal output power] – [cable Loss] – [allocated power] Omni antenna with 0 – 2 dBi gain, Patch antenna with wide beam of 10 dBi gain, At maximum 17 dBi At mimimum 5 antennas and splitters At minimum cable loss is 10 dB Example of the available antenna specification EIRP = 33 dBm (DL output power) - 7 dB (Splitter Loss) – 5 dB (Cable loss) + 17dBi (Antenna gain) = 38 dBm ERP = EIRP – 2.15 dB = 38 – 2.15 = 35.85 dBm < 37 dBm (FCC limit) ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 16 / 70 User Manual of SRDR-33-7080-A-FN Product Overview 2.1 Introduction SRDR-33-7080-A-FN is an excellent product from SOLiD, which is the signal booster to support public safety radio services typically indoors. It was designed to give great benefits to agents such as First Responder, fire fighters to communicate each other under the emergency as well as a normal situation. And it provides customers the effective solution from the point of total cost of ownership, survivability, flexibility to the circumstance, and easy installation. SRDR-33-7080-A-FN is a dual band digital repeater to choose the various digital filters with several delays and several rejections. It features 36 FPGA-based, software-controlled, and user-selectable filters across 700 & 800 MHz bands. It can help you configure the best operation to eliminate the adjacent interference and to mitigate the Time Difference Interference (TDI) problem. So, it can be configured as FCC part 90. Class A device or FCC part 90. Class B device. User should follow instructions which are described in 1. 2 FCC notices in case of class B device. 2.2 Main Features NFPA/IFC Compliant Dual-Band 700/800 MHz & 2W per Band FirstNet Support Channel-Selective & Band-Selective by user-selectable software Integrated Battery Charger and Alarming Operation at 60°C and Extended Life Simple and Low-powered Active DAS interface ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 17 / 70 User Manual of SRDR-33-7080-A-FN 2.3 Ordering Information Table 1. License Descriptions SRDR-33-7080-A-FN Digital Repeater, 2 Watt, 700/800 MHz Public Safety + FirstNet, Band selective, NEMA4, NFPA/IFC Compliant. SRDR-33-L1 Digital Repeater Channel Selective License Upgrade SRDR-33-L2 Digital Repeater Echo Cancellation License Upgrade SRDR-33-L3 Digital Repeater System Analysis Module License Upgrade, includes plugin module The SOLiD RESPONDER is available from the factory in four different configurations. The base configuration defaults to a “Band Selective” device and does not include the Echo Cancellation or System Analysis features. The base configuration can be factory upgraded by purchasing any, or all, of the three additional licensable software configurations. Refer to the following descriptions or consult your local SOLiD Sales Engineer for guidance in selecting the best product configuration for your application. SRDR-33-7080-A-FN (Base Configuration) This Part Number represents the base configuration, which includes the Band Selective mode only (FCC Class B Wideband Signal Booster Device). All Class B Signal Booster devices must be registered with the FCC prior to operation. SRDR-33-L1 (Channel Selective Software Upgrade) This license upgrade adds a Channel Selective mode allowing the user to switch between Band Selective and Channel Selective operation. When operating at channel bandwidths of 75KHz or less, this device is classified by FCC as a Class A Narrowband Signal Booster Device, and as such, does not require registration with the FCC. Channel Selective mode is typically used in RF congested areas where narrow pass windows are needed to minimize interference from undesired frequencies. In Channel Selective mode, also known as “Channelized” mode, the user can assign up to 36 window filters, in any increment, between the 700 and 800 MHz bands. SRDR-33-L2 (Echo Cancellation Software Upgrade) Echo Cancellation Mode (“ZeroDelta” feature). This license upgrade adds an Echo Cancellation feature to Band and Channel Selective modes. The Echo Cancellation feature includes an advanced patented algorithm that allows the repeater to maintain maximum gain even when system isolation deteriorates to as low as the gain of the repeater. Traditional repeaters require at least 15-20dB more isolation than system gain to prevent oscillation. The “ZeroDelta” feature allows normal operation with 0dB difference between system isolation and system gain. This feature has many advantages such as increased system stability and reliability, easy system commissioning and optimization, and increased coverage footprint and cost savings in applications where weak off-air signals require a high gain setting. SRDR-33-L3 (System Analysis Module – Hardware and Software Upgrade) System Analysis Module (SAM). This part number includes a hardware plug-in module and software that enables advanced system analysis, such as: data logging of wideband spectrum to aid in application of window filters, to spectrum analyzer features that display near-real time spectrum readings for both input and output. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 18 / 70 User Manual of SRDR-33-7080-A-FN 2.4 Signal Flow Below is the block diagram which describes the signal flow in the equipment. PRDU LO1 FPGADownlink 700 PS 700 PS Donor Antenna Service Antenna 800 PS 800 PS LO2 700 & 800 PS LO3 FPGAUplink 700 PS 700 PS 800 PS 800 PS LO4 Figure 2. Signal Flow of SRDR-33-7080-A-FN 700 PS stands for the signal that includes Public Safety narrowband (6+6 MHz) and the FirstNet (10+10 MHz). 800 PS stands for the signal that includes NPSPAC (3+3 MHz), PS & Non-Cellular SMR (6+6 MHz), and Expansion Band (1+1 MHz). Off-the-air RF signal that received from the donor antenna is down-converted to the IF signal. It goes to the FPGA after the analog-to-digital conversion, and filtered to remove the unwanted signal. The signal that comes from FPGA is reconstructed in the digital-to-analog converter. And then it would be up-converted by the same local oscillator with the down-conversion. So, its frequency is same to the original signal. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 19 / 70 User Manual of SRDR-33-7080-A-FN 2.5 Description of Modules Figure 3. Inner View of the SRDR-33-7080-A-FN 2.5.1 Integrated PSU The integrated PSU consists of AC to DC power supply, DC to DC power supply, and the 48V battery charger. This feature enables to operate with AC power source and batteries for redundancy. 2.5.2 Power Amplifier Unit (PAU) This unit amplifiers a low-power signal to the high-powered RF signal. 2.5.3 Digital Unit (DU) The unit performs a powerful digital filtering. 2.5.4 Radio Frequency Unit (RFU) Each signal on the 700 & 800 MHz band is converted into the signal with an intermediate frequency to be filtered. For high input power it is attenuated to prevent the saturation in the analog-to-digital converter. The signal which comes from the digital-to-analog converter is also converted into the signal with an original radio frequency. 2.5.5 CPU This unit controls and monitors every module except for multiplexer. After connecting the product to PC, user set up parameters to operate via GUI software. And it will monitor and store all status to be chosen. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 20 / 70 User Manual of SRDR-33-7080-A-FN Multiplexer 2.5.6 Multiplexer combines several signals of multiple paths into those of one path. And it acts vice versa. This module is made up of cavities. Signal Analysis Module (SAM) 2.5.7 This is a hardware plug-in module with a high processing power and it enables advanced system analysis, such as: data logging of wideband spectrum to aid in application of window filters, to spectrum analyzer features that display near-real time spectrum readings for both input and output. Table 2. Unit Functions No. Unit Integrated PSU PAU DU RFU CPU Multiplexer Enclosure Description AC input : 100 – 120 VAC, DC input: 48 – 56 VDC, Batteries input: 43 – 56 VDC Output: 29V, 5V Filters and amplifies highly downlink signals in 700 MHz band irrespetively Filters and amplifies highly downlink signals in 800 MHz band irrespetively Filters and amplifies highly uplink signals in 700 MHz band & 800 MHz band Filters signals Cancels echo signals and amplifies original input signals Down-converts and up-converts the frequencies of signals Attenuates and amplifies signals Controls each unit to operate Monitors the defined status of each unit Can be accessed by Ethernet and 2.4 GHz Wi-Fi Separates a downlink signal which comes from the donor antenna into signal in the 700 band and the signal in the 800 band. And combines vice versa for uplink signal. Combines two downlink signals which come from RFU into one signal to the service antenna and separates vice versa for uplink signal. Enclosure to satisfy NEMA4 Can be mounted on the Wall/Rack ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 21 / 70 User Manual of SRDR-33-7080-A-FN 2.6 External Interface All excternal connectors are located in the bottom side of the product. Figure 4. External Connectors ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 22 / 70 User Manual of SRDR-33-7080-A-FN 2.7 Operation 2.7.1 Classes and Passbands Types The class of device which is defined in the FCC part 90 is distingushed by the below passbands and each bandwidth of channel filter. And it is enabled by the digital filter which user can choose approprietly under the cicumstance. Table 3. Passbands of Class A Device Bands Category Downlink Uplink 700 MHz PS narrowband 769 – 775 MHz 799 – 805 MHz 800 MHz Public Safety 851 - 861 MHz 806 - 816 MHz Table 4. Passbands of Class B Device Bands 700 MHz 800 MHz Category Downlink Uplink LTE 758 – 768 MHz 788 – 798 MHz PS narrowband 769 – 775 MHz 799 – 805 MHz Public Safety 851 - 861 MHz 806 - 816 MHz There are 2 different passband types for our equipment. Below is the table which describes the name and the FCC part 90 Class. Table 5. Passband Types License Passband Type Mode Number FCC part 90 Class M701 Class B Device M702 Class B Device Basic Pre-configured M703 Class B Device (Band-Selective) Band Filters M801 Class B Device M802 Class B Device M803 Class B Device M036 Class A Device SRDR-33-L1 (Channel-Selective) Channelized Filters ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 23 / 70 User Manual of SRDR-33-7080-A-FN All the spectrum examples per mode numbers are presented below. The blue squares denotes the digital filters, and the vertical lines in them denotes the radio signals. The dark blue ones are service channels, and the red ones are interferences. 758 788 763 793 768 769 798 799 775 805 Figure 5. The Spectrum of M701 758 788 763 793 768 769 798 799 775 805 Figure 6. The Spectrum of M702 758 788 763 793 768 769 798 799 775 805 Figure 7. The Spectrum of M703 851 806 854 809 860 861 815 816 Figure 8. The Spectrum of M801 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 24 / 70 User Manual of SRDR-33-7080-A-FN 851 806 854 809 860 861 815 816 Figure 9. The Spectrum of M802 851 806 854 809 860 861 815 816 Figure 10. The Spectrum of M803 700 Channel-Selective Spectrum excluding FirstNet 758 788 763 793 768 769 798 799 800 Channel-Selective Spectrum 775 805 851 806 854 809 860 861 815 816 Figure 11. The Spectrum of M036 excluding FirstNet 700 Channel-Selective Spectrum including FirstNet 758 788 763 793 768 769 798 799 800 Channel-Selective Spectrum 775 805 851 806 854 809 860 861 815 816 Figure 12, The Spectrum of M036 including FirstNet ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 25 / 70 User Manual of SRDR-33-7080-A-FN 2.7.2 Procedure to Choose Passband From the GUI for setup the equipment, user can choose one passband type among the possible several alternatives. It is noticed that a specific passband type named M036 is only available if SRDR-33-L1 license exists. The procedure of choice passband’s type is executed by the wizard in the GUI. Below are pictures which are captured in the GUI. User configures digital filters in the step 3. Step 1 Click Operation Mode Wizard Step 2 Choose the service band ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 26 / 70 User Manual of SRDR-33-7080-A-FN Step 3-1 Choose the passband types among the 3 options. Pre-configured Filter A step is followed by step 3-1 Choose the detailed passband option among the preconfigured filters in Public Safety 700 MHz band. Another step is followed by step 3-1 Choose the detailed passband option among the preconfigured filters in Public Safety 800 MHz band. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 27 / 70 User Manual of SRDR-33-7080-A-FN Step 3-2 Choose the passband types among the 3 options. 36 Channelized Filter Step 4 Choose the DAS Interface choose the output port to the service antenna Step 5 Choose the power supply configuration choose the redundancy type of power source ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 28 / 70 User Manual of SRDR-33-7080-A-FN Step 6 Select Power Amplifier’s Shutdown for the specific region Step 7 Report the summary of the user selection. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 29 / 70 User Manual of SRDR-33-7080-A-FN 2.7.3 Automatic Shutdown of Amplifiers The equipment has an automatic shutdown function to protect the power amplifiers themselves and the wireless network when the normal operational conditions cannot be maintained. The conditions of the shutdown RF power amplifier are below. A. High Output Power from RF Power Amplifier (Shutdown Algorithm type 1) The equipment shut down the power amplifier automatically if the composite output power exceed the threshold level for 10 seconds. The level can be set through GUI. Once an automatic shutdown occurs, the equipment will turn on power amplifier automatically in 10 seconds to assess the power amplifier’s condition. If the shutdown condition is detected again, the equipment will shut down the power amplifier. It tries to do this process up to 3 times. If the shutdown condition is released, it continues to operate. After an automatic shutdown occurs 3 times continuously, an automatic recovery is terminated. So, to turn on power amplifier is only possible by setting PA operation in the GUI. The following diagram shows this shutdown algorithm type 1. 2nd recovery 1st recovery Normal Operation 10 sec 10 sec PA on Shutdown 3rd recovery 10 sec PA on PA on PA on 10 sec 10 sec 10 sec Shutdown 10 sec 4th alarm is detected 2nd alarm is detected 1st alarm is detected 3rd alarm is detected Figure 13. 3 times Failure in Shutdown Algorithm Type 1 1st recovery Normal Operation Shutdown 10 sec 10 sec PA on 10 sec 2nd recovery PA on 10 sec PA on 10 sec 2nd alarm is detected 1st alarm is detected 3rd alarm is released Figure 14. 2 times Failure in Shutdown Algorithm Type 1 B. High Input Power from RF Power Amplifier (Shutdown Algorithm type 2) The equipment shut down the power amplifier automatically if the composite input power exceed the threshold level for 10 seconds. The level can be set through GUI. Once an automatic shutdown occurs, if only the shutdown condition is released, the equipment would turn on power amplifier automatically. The following diagram shows this shutdown algorithm type 2. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 30 / 70 User Manual of SRDR-33-7080-A-FN Normal Operation Shutdown occurs PA on PA on No Release Shutdown Shutdown 10 sec Status Alarm 10 sec 10 sec Alarm Release Shutdown No alarm Figure 15. Shutdown Algorithm Type 2 C. High Temperature at RF Power Transistor (Shutdown Algorithm type 2) The equipment shut down the power amplifier automatically if the composite input power exceed the threshold level for 10 seconds. The level can be set through GUI. Once an automatic shutdown occurs, if only the shutdown condition is released, the equipment would turn on power amplifier automatically. The following diagram shows this shutdown algorithm type 2. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 31 / 70 User Manual of SRDR-33-7080-A-FN Installing the SOLiD RESPONDER 3.1 Overview of the Installation Procedure ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 32 / 70 User Manual of SRDR-33-7080-A-FN 3.2 Location Installation Site 3.2.1 Product Dimension Below are the dimensions of SRDR-33-7080-A-FN. Figure 16. Dimensions of SRDR-7080-A-FN Table 6. Mechanical Specification Items Value Dimensions (HxWxD) 530 x 420 x 208 (mm) 20.9 x 16.5 x 8.2 (inches) 630 x 460 x 218 (mm) 24.8 x 18.1 x 8.6 (inches) Weight 34kg, 75 lb 19” Rack Mount Yes Operating Temperature -30 – 60 °C ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Comments Without bump With bump Ambient Temperature Page 33 / 70 3.2.2 Installation Environment User Manual of SRDR-33-7080-A-FN The following criteria should be considered when selecting the SOLiD Responder installation site location. During transportation and installation, take necessary handling precautions to avoid potential physical injury to the installation personnel and the equipment. Input Signal Requirements BTS channels, channel power BTS antenna location, height, gain Distance from the BTS antenna Donor antenna type, gain, and location It is recommended that the installation location be as close as possible to the donor antenna site in order to reduce the cable loss to a minimum. Environmental Requirements Use a suitable mounting surface, such as a flat back rigid wall. The SOLiD Responder can be mounted to the 19” rack. The SOLiD Responder is convection cooled, so airflow should be possible. Electrical Requirements Follow Electro-Static Discharge (ESD) precautions. Verify that the equipment has been well grounded. This includes antennas and all cables connected to the system. Ensure lightning protection for the antennas is properly grounded. The power up procedure should be followed by the connecting all components arould the SOLiD Responder to prevnet from the electrical damage. Ensure cables are properly routed and secured so that they are not damaged. 3.3 Unpacking and Package Contents Examine the packing container for damage before unpacking the product. After unboxing, verify that all of the items listed in the packing list are included. Table 7. Packing List of the SRDR-33-7080-A-FN No. Items Quantity Description SRDR-33-7080-A-FN The main body of equipment This includes the keys of door insideof door. AC Cable Power cable for AC 100 – 120 VAC DC Cable Power cable for DC 48VDC and 48V line batteries NFPA Alarms Cable Water-proof RJ-45 Connector External alarms cable for NFPA alarm box. It includes 5 possible alarms which are chosen by user. Accessory for the Ethernet cable to connect with the equipment. For SNMP traps. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 34 / 70 User Manual of SRDR-33-7080-A-FN 3.4 Mounting the Product 3.4.1 Mounting Method SRDR-33-7080-A-FN is designed to be water-proof and dirt-proof. The unit has the structure of One-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of NEMA4. SOLiD RESPONDER can be mounted into either of a 19” Standard Rack or on a Wall. Basically, it has both of a Wall Mount Bracket and a Rack Mount Bracket. Depending on the use of the Rack Mount Bracket, the bracket can be removed. The following shows dimension of the fixing point for the Wall Mount Bracket. Figure 17. Mount Bracket for Wall and Rack Figure 18. Dimensions used to install Product on the Wall ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 35 / 70 User Manual of SRDR-33-7080-A-FN 3.4.2 Installation the Wall Mount Bracket SRDR-33-7080-A-FN installation bracket is attached on Enclosure when is delivered. It doesn’t need to remove bracket to install enclosure. simply after installing 4 of M12 mounting bolts, secure 4 mounting bolts tightly First, install 2 of M12 mounting bolts roughly half way on the enclosure and install enclosure over the bolts and secure tightly. Second, install 2 of M12 mounting bolts under the enclosure and secure tightly 3.4.3 Rack Mount Installation SOLiD RESPONDER would be the best fit to be mounted on 19” standard rack. into a rack. The unit occupies around 15U of space except cable connection. 3.5 Grounding The Grounding terminal is located at the bottom of heat-dissipating pin in the back of enclosure, and it’s fixed by M4 screw. The recommended thickness of cable is AWG#10 – 12 copper grounding wire. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 36 / 70 User Manual of SRDR-33-7080-A-FN Figure 19. The Location of Ground Lug The specification of compression terminal is like below. Figure 20. Information of Terminal The required part number is JOCT 6-2 supporting AWG 12 – 10. The way to install the grounding cable comply with below procedures. 1. Loosen a M4 screws and then take compression terminal off 2. Insert AWG#12~10 Grounding Wire into terminal and then compress a terminal using tool 3. Assemble the terminal which made in step “2” using M4 screws 4. Cut the ground wire to proper length and connect it to the earth ground source ( Round terminals located on the side of a 1 mm2 (6 AWG) or more wires Using permanently connected to earth.) ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 37 / 70 User Manual of SRDR-33-7080-A-FN 3.6 Antenna Connections and Guidelines 3.6.1 Donor Antenna Installation Guidelines Accurately determine the azimuth to the donor site. Obtain the donor site information and approval from the service provider/carrier. Ensure that the radiation path to the donor site is unobstructed. Mount the donor antenna at or toward the edge of the roof, in the direction of the donor site. Avoid having the RF signal from the donor pass above the location(s) of the service antennas. Normally, the service antennas are installed behind and below the donor antenna, as viewed from above. This approach helps avoid interference and feedback to and from the service antennas. Normally, mounting the donor antenna higher will allow a less obstructed path to the donor site. However, in high traffic metro areas, avoid mounting the donor antenna higher than necessary, as the quality of the donor signal may become less stable and it is more likely to encounter adjacent channel interference. When possible, shield the rear of a donor antenna by locating it so that any HVAC units and/or penthouse structures are behind the antenna, relative to the donor cell site location. 3.6.2 Indoor Antenna Installation Guidelines Use omnidirectional antennas indoors and locate them centrally with respect to the intended coverage area to minimize signal leakage to the outside. Only use directional antennas indoors in special cases when higher gain and directionality would be helpful and RF exposure limits will not be exceeded. To avoid Signal Booster uplink overload and gain limiting, mount the indoor antennas away from areas where mobile subscribers frequently use their phones, such as desks or dispatch areas. To determine the quantity and locations of indoor antennas, measure Received Signal Strength Indication (RSSI) using DM Tool software to determine areas of weak signals. These are the approximate areas where indoor antennas may be needed. Be aware that the signal from an indoor antenna, in most cases, can be expected to penetrate approximately two standard sheet rock walls to reach users. If the signal must travel through more than two walls, or if the walls are made of materials other than sheet rock, it may be necessary to split the available signal and add more antennas. 3.6.3 RF Cable Installation Guidelines For all coaxial connections to/from the Signal Booster - high performance, flexible, low loss 50 ohm coaxial communications cable. All cables shall be weather-resistant type. If the coaxial cables are NOT weather-resistant type: wrap the exterior coaxial cables with insulation and holding tape (Type 3M Rubber splicing tape) for environmental protection and to ensure longer lifetime. Cable length - determined by the Signal Booster installation plan. When calculating the cablelength, take into account excess cable slack so as not to limit the insertion paths. 3.6.4 Connecting Antennas Connect the Donor and Service antennas. Verify all RF connectors are tightened and the cables and antennas are secured. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 38 / 70 User Manual of SRDR-33-7080-A-FN 3.7 Connecting Power Cables and Power-up 3.7.1 Integrated PSU The integrated PSU consists of AC to DC power supply, DC to DC power supply, and the 48V battery charger. This feature enables to operate with AC power source and batteries for redundancy. Two external ports such as AC input and DC input have circuit breaker to protect themselves. Below is the table for the power supply specification. Table 8. Power Supply Specification Item Description Power Supply AC 100 - 120 VAC DC 48 – 56 VDC 48V-rail charger for lead-acid batteries Charger with State of Charge detection 3.7.2 Power Redundancy SRDR-33-7080-A-FN supports AC 120V power source, 48V DC power source, DC 48V batteries and charger. So 3 types of power supply configuration are possible for power redundancy. These block diagrams are below. Integrated PSU AC 100 - 120 VAC AC/DC CB1 AC – UPS DC/DC 29V 29 V DC/DC 5V 5.0 V Charger DC CB2 Low Voltage Disconnect Figure 21. Connection for AC-UPS site Integrated PSU DC – UPS AC AC/DC CB1 Battery Enclosure 29 V Charger 43 ~ 56 VDC DC/DC 5V DC CB2 SLA Batteries DC/DC 29V 5.0 V Low Voltage Disconnect Figure 22. Connection for DC-UPS site ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 39 / 70 User Manual of SRDR-33-7080-A-FN Integrated PSU AC 100 - 120 VAC DC/DC 29V AC/DC CB1 AC & Batteries Charger 43 ~ 56 VDC DC/DC 5V DC CB2 SLA Battery 29 V 5.0 V Low Voltage Disconnect SLA Battery SLA Battery SLA Battery Figure 23. Connections with AC & Batteries 3.7.3 AC Power Cabling SRDR-33-7080-A-FN supports 100 – 120 VAC input power. The pin discription of AC port is below. Table 9. AC Port Pin Description Port Outlook MS Connector Name Description AC 120V-H AC Hot AC 120V-N AC Neutral AC GND AC Ground Numbering Figure 24. AC Cable Drawing A provided outside power cable is only one type with AWG#16 & 2m. From the above drawing you can verify it easily. Note that you should match exact polarity of AC voltage. If you use the attached AC cable in the shipping box, you don’t need to worry about it. Otherwise the equipment can have an severe damage under power-on. Usually a circiut breaker on AC power line will work to prevent damage under the abnormal situation. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 40 / 70 User Manual of SRDR-33-7080-A-FN 3.7.4 DC Power Cabling SRDR-33-7080-A-FN supports 48VDC input power. An actual voltage is 43 – 56 VDC of batteries or DC-UPS. The pin discription of DC port is below. Table 10. DC Port Pin Description Port Outlook MS Connector Name Description NC Not Connected NC Not Connected + - Numbering 48VDC Figure 25. DC Cable Drawing The provided outside power cable is only one type. From the above drawing you can verify it easily. Note that you should match exact polarity of DC voltage. Otherwise the equipment can have an severe damage under power-on. 3.7.5 Power Up After verifying the proper connection of wires in the each power cable, power up SRDR-33-7080-A-FN. Don’t miss gounding. If an abnormal electrical situation occurs, each circiut breaker on two power lines will work to prevent damage. If you succeed in power up the product, you can see the green LED on the top of the integrated PSU light. AC power source has a priority over DC power source in the SRDR-33-7080-A-FN. So, in case that two power switches are on, the power up from the DC power source wouldn’t performed. You should check the availablity of DC power source with AC power switch off. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 41 / 70 User Manual of SRDR-33-7080-A-FN 3.8 Connecting NFPA Alarms 3.8.1 Choose the alarms to be monitored SOLiD Responder provides upto 5 alarms to be monitored by the external alarm box and SNMP traps. They consist of 2 system alarms and 3 power alarms. Below is the alarms to be provided by the external alarm cable. Table 11. NFPA Alarm Connection upon the Power Supply configuration Items AC & Batteries AC UPS DC UPS System component malfunction. Connect Connect Connect VSWR-antenna malfunction Connect Connect Connect Normal AC power, Loss of normal AC power Connect Connect Do Not connect Battery charger failure Connect Do Not connect Do Not connect Low battery capacity Connect Do Not connect Do Not connect Accrding to the power supply configuration, the related 3 power alarms are monitored and masked suitably. But user should connect the proper alarms because the each external alarm signal is dedicated to the fixed wire in the cable, and it’s unchanged by software. Below is the proper connection of relat output cable with alarm box upon the power supply configuration. 3.8.2 Select the type of external alarms SOLId RESPONDER provides 3 pins per every alarm. The first one is a common signal, the second one is normal-open signal, and the third is normal-close signal. Since the alarm state is desired to be sustained under the unpowered situation, 3 wires per an alarm are adopted instead of programmable 2 wires. So, a customer just have to choose an appropriate signal according to the type of alarm box. Below is the table describing the pinout of the relay output. User can recognize the proper wire easily due to the labeling with numbers and colors. No. Pin Name NC1 COM1 Description label A Normal-Closed Signal for System Malfunction A Common Signal for System Malfunction NO1 A Normal-Open Signal for System Malfunction NC2 A Normal-Closed Signal for Antenna Malfunction COM2 A Common Signal for Antenna Malfunction NO2 A Normal-Open Signal for Antenna Malfunction NC3 A Normal-Closed Signal for AC loss COM3 A Common Signal for AC loss NO3 A Normal-Open Signal for AC loss ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 42 / 70 User Manual of SRDR-33-7080-A-FN 10 NC4 A Normal-Closed Signal for a charger failure 11 COM4 A Common Signal for a charger failure 12 NO4 A Normal-Open Signal for a charger failure 13 NC5 A Normal-Closed Signal for the state of charge 70% 14 COM5 A Common Signal for the state of charge 70% 15 NO5 A Normal-Open Signal for the state of charge 70% 16 GND Signal Ground Figure 26. Relay Output Cable Drawing 3.8.3 Connect cable to the alarm box 3.8.4 Verify the state of connection When a user needs to create external alarms on purpose or for testing, additional feature as shown below can be used. External Alarm Emulator can be found in the top side of Log/Alarm window in the GUI. Figure 27. External Alarm Emulator When you click the ON/OFF button in the window, External Alarm Emulator generates the virtual alarm to be verified. You can see the result in the status LED or in the alarm box. When the External Alarm Emulator window is closed, to emulate alarms will be cleared. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 43 / 70 User Manual of SRDR-33-7080-A-FN Setup and Commissioning 4.1 Overview of the Commissioning Procedure ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 44 / 70 User Manual of SRDR-33-7080-A-FN 4.2 Connecting the GUI to the Product 4.2.1 Network Information of GUI The computer where the GUI has been installed can be connected with SOLiD Responder through wireless or wired connection. Below is the figure of the wired connection port. Figure 28. GUI Port of SOLiD Responder SOLiD Responder has the built-in 2.4GHz Wi-Fi module so that a wireless connection is available without the cable. The computer should be located within the coverage range of 2.4 GHz Wi-Fi, typically hundred feet away. However, if there are obstacles between them, that could affect the communications. Table 12. IP address of SOLiD Responder Type IP Address Wired Connection Via Ethernet (GUI port) Wireless Connection Via 2.4GHz Wi-Fi Port Number 192.168.100.1 20000 192.168.30.1 20000 Table 13. Access Information to AP SSID of AP SOLiD_PS_#### Access Password 12345678 ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 45 / 70 User Manual of SRDR-33-7080-A-FN 4.2.2 Log in GUI When you click the Responder GUI icon, the following window will be popped up. Figure 29. Login Window To enter the GUI, type the login password that has been delivered. 4.2.3 GUI Main Screen Below is the layout of the main screen of GUI. Figure 30. Main Screen of GUI ① ② ③ Communication: it represents the communication status and the connection information with the device. Main Menu: these are categorized in three parts. A. Device Monitoring: these features are for monitoring the device B. Commissioning: these features are for setting up the device C. Management: these features are for device management. Main Window: these features are for checking all the information about the Responder. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 46 / 70 User Manual of SRDR-33-7080-A-FN Table 14. Description of Main Menu Item Descriptions Device Monitoring System Information CH Power Spectrum It displays current status and alarms of the Responder. It displays the information about input/output signals (DL only) and filters of the Responder in the graphs. Commissioning Operation Mode Service Channels Filter / CH Setup AMP / Isolation Users can see the operation mode of the Responder And, It allows users to select a mode to operate the Responder. It displays frequency information about service channels that are provided in your area. It displays information about the filters, channel powers, and gains in the Responder. It displays the status of the power amplifier and the antenna isolation. Management Log / Alarm Upgrade / Reset SNMP Save Screenshot It allows users to set alarms’ condition and to check alarm history as well. It allows users to update the firmware and to reset the Responder. It allows users to set network parameters and the current time. It allows users to capture the current GUI screen image. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 47 / 70 User Manual of SRDR-33-7080-A-FN 4.3 Configuring Operation Mode of the Product 4.3.1 Operation Mode Window The below Window shows the operation mode that user has selected or factory setting. Figure 31. System Operation Mode Window Table 15. Description of Operation Mode Items Item Service Frequency Band Band Selective Channel Selective Description ON/OFF of 700M/800M Path The selected option is shown among the 2 options. ① Pre-Configured Filter Mode ② 36 Channelized Filter Mode The 2 option can be possible with the Channel license. nd The mixed combination of filters across two bands is impossible. Echo Cancellation DAS Interface Power Configuration ON/OFF of Echo Cancellation This feature can be chosen with Echo Cancellation license. The downlink output and uplink input port to the service antenna The power redundancy type for alarms. and the status of the power-saving mode ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 48 / 70 User Manual of SRDR-33-7080-A-FN AMP Shutdown The status of Shutdown AMP function at the high temperature. 4.3.2 Changing Operation Mode To change an operation mode, click the Operation Mode Wizard button in the top of the window. You can’t edit or modify the setting by clicking directly the main window. The operation mode will be changed after press Finish button in the popped small window that appears at last stage. 4.3.3 Filter Mode The Responder supports two types of filters. (Note that you need to have Channel License for using Channelized Filter Mode.) Item Description Pre-Configured Filter Mode Band Selective ON/OFF of 700M PS NB and 700M FirstNet Passband of 800M PS (with 3, 9, and 10 MHz filters) 36 Channelized Filter Mode Channel Selective (with license) up to 36 channel filters for 700M and 800M PS Any increment is possible across two bands 4.3.4 Echo Cancellation The Echo Cancellation feature includes an advanced algorithm that allows the repeater to maintain maximum gain even when system isolation deteriorates to as low as the gain of the repeater. Traditional repeaters require at least 15-20dB more isolation than system gain to prevent oscillation. The “ZeroDelta” feature allows normal operation with 0dB difference between system isolation and system gain. 4.3.5 Power Supply Configuration Select a power supply configuration from the list to report alarms properly. When the AC & 48V batteries with Charger is selected, Power Saving Mode can be chosen. Figure 32. Power Supply Configuration ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 49 / 70 User Manual of SRDR-33-7080-A-FN 4.3.6 AMP Shutdown function It allows users to choose whether to shut down the AMP when the temperature reaches the specific level. Figure 33. AMP Shutdown Function 4.3.7 Summary At the last stage, you can check all the information of the modes you selected. When you click the Finish button, those selected modes will be applied to the Responder. Figure 34. Summary of Selecting the Operation Modes ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 50 / 70 User Manual of SRDR-33-7080-A-FN 4.4 Setup Channel Configuration & RF parameters 4.4.1 Input the information of service channels Service Channels are the channels which is used for the public safety purpose in the specific region. These channels should be passed and amplified in the equipment. And it is, of course, essential for the channel filters. All the information about the service channels can be imported and be exported with the csv file. Below is the window for the importing the service channels. Figure 35. Service Channels Window 4.4.2 Setup Parameters of Digital Filter 4.4.2.1 Pre-Configured Filter Mode When you select Pre-Configured Filter mode from the Operation Mode, three band-configuration will be displayed as shown below. In this mode, users can control ON/OFF feature of each band and adjust attenuation values up to 10dB. In the System setting on the bottom, users can set the maximum gain and maximum output power of the system. The equipment will not exceed these level. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 51 / 70 User Manual of SRDR-33-7080-A-FN Figure 36. Pre-Configured Filter Mode Window Table 16. Pre-configured Filter Parameters Item Range Description 700M Max Gain 65 – 95 dB Set the maximum gain of 700M 800M Max Gain 65 – 95 dB Set the maximum gain of 800M 700M DL Output Power 3 – 33 dBm Set the maximum output of 700M DL 800M DL Output Power 3 – 33 dBm Set the maximum output power of 800M DL UL Output Power 0 – 27 dBm Set the maximum output power of UL Filter Type UL Gain Balance Squelch Time Band/Channel On/Off 1 – 3600 sec only displayed UL gain has the same value with DL gain As a default, gain balance is on. Dwell time to detect the Squelch ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 52 / 70 User Manual of SRDR-33-7080-A-FN 4.4.2.2 36 Channelized Filters In the 36 Channelized Filter Mode, users can set the total 36 channel-filters across 700M and 800M bands. Users can Export and Import the information about the current filter. Figure 37. Channelized Filter Mode Window Public Safety Filters for the narrowband include the following information. Table 17. 36 Channelized Filter Parameters Item DL Description Start CH Center Freq. The lowest channel freq. of the passband Stop CH Center Freq. The highest channel freq. of the passband CH Filter Bandwidth of filter Delay Group Delay of filter ATT Attenuation value Squelch Squelch level Input Input power Interference Pre filter: Interference status before a CH filter Post Filter: Interference status after a CH filter ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 53 / 70 User Manual of SRDR-33-7080-A-FN UL Output Output power Current Gain Current gain Squelch Squelch level Input Input power Output Output power Current Gain Current gain The color of circles in the Interference column indicates the relative strength with the channel power. This state is not real-time, but is updated every 2 minutes. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 54 / 70 User Manual of SRDR-33-7080-A-FN 4.5 Isolation Measurement & Tune-up 4.5.1 Monitor Downlink Input Power Observe downlink input power from the GUI. To receive the input signal with high signal-to-noise ratio is essential to maintain the service with better condition. Align the direction of donor antenna until the DL input power reading is maximized. 4.5.2 Measure the isolation between donor antenna and service antenna SOLiD Responder has the powerful algorithm to measure antenna isolation which doesn’t interfere with radio service. After finishing the basic connection with both antennas, user just enable the amplifier and wait for the result for a moment. Figure 38. Isolation Measurement Window 4.5.3 Evaluate isolation value & reconfigure the antenna installation BDA oscillation is caused by low isolation (antenna separation) between donor antenna and service antennas. The recommended isolation between those antennas is 20 dB above the system gain. The amount of isolation that can be achieved between antennas depends on several factors, such as the physical vertical and horizontal separation (distance between the antennas), polarization, radiation pattern of the antennas, the medium between the antennas, antenna gain etc. Considering the above serveral conditions, evaluate the antenna isolation if it is adequate to cover. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 55 / 70 User Manual of SRDR-33-7080-A-FN 4.5.4 Test coverage area Use test-quipment to verify field intensity within the coverage area. If needed, realign the service antenna to achieve the desired coverage. Note that the equipment gain could not be set to maximum or the output power is not high enough due to insufficient donor and service antennas isolation, then the antennas’ position should be changed to increase isolation. 4.5.5 Verify UL gain and Performs test calls Typically, the UL gain is set around 5dB less than DL gain. Users can calculate and determine if the repeater UL noise will interfere with the BTS. Perform test calls in the coverage area to evaluate voice quality. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 56 / 70 User Manual of SRDR-33-7080-A-FN 4.6 SNMP traps & Time Settings The Responder can notify the remote server about the external alarm output through SNMP (Simple Network Management Protocol) Traps. To use this feature, fill the parameters about network and SNMP traps in the ① section as shown below. Figure 39. SNMP Configuration The Responder has another port that can be connected to the external network as well as a port for GUI. You should fill the appropriate network parameters in the ② section to connect the Responder to the internet. The Responder has Real Time Clock(RTC) inside and uses Universal Time Coordinated (UTC). Users can synchronize Responder’s time with the time of GUI in the PC by clicking Sync.PC System button in the ③ section. Network Time Protocol (NTP) is a networking protocol for clock synchronization between computer systems over packetswitched, variable-latency data networks.If you change the time in the ③ section, the time for the alarm message also changes. Table 18. Parameters of Time Setting Item Description System Time (UTC) It is the UTC time that the Responder has set as the absolute time. System Time (Your Time zone) Local time: If you connect your computer with the Responder, the System Time on the GUI will display the time of your computer. Sync. PC <-> System It synchronizes the time of the Responder with currently connected computer. Time synchronization can be done and controlled automatically when the Responder is connected with the external network. To use this feature, enter the IP address of NTP server that will be connected. NTP#1 & 2 Server IP ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 57 / 70 User Manual of SRDR-33-7080-A-FN Administrations 5.1 Viewing General Information Since the passband’s ranges of SOLiD RESPONDER are 12.5 – 200 KHz, FCC part 90 Class A or B device is possible in this mode. If all the passbands are no wider than 75 KHz, the equipment will be Class A device. Otherwise it is Class B device. User can also check FCC part 90 Class from the System Information window. Figure 40. System Information Window Table 19. Description of System Information Item Description Product Information Manufacturer Product Name Model Name Serial No. Product Temperature Power Configuration SOLiD RESPONDER Model information, SRDR-33-7080-A-FN Serial number of the Responder The temperature on the bottom side of the Responder Status of power supply Software Version CPU FPGA DL, FPGA UL Information regarding software versions ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 58 / 70 User Manual of SRDR-33-7080-A-FN Batch, PAU ICS, Channel Information whether a user has the license or not Service Information FCC Part 90 Class B/Band-Selective A/Channel-Selective 700M FirstNet 700M PS Filter 800M PS Filter Filter information that is in service Power AC DC or Battery Status of power supply RF Information 700 Band Interface 800 Band Interface DL 700 Input DL 700 Output DL 800 Input DL 800 Output UL Total Output ANT Isolation Output port to the service antenna Active DAS or Passive DAS DL 700M input power DL 700M output power DL 800M input power DL 800M output power UL 700M/800M composite output power Antenna isolation information 5.2 Alarm Remedy Below is the table that describes the meaning and the condition of alrams. Table 20. Description of Alarms Alarm Item Description Dwell Time to issue Dwell Time to Clear Immediately Immediately Immediately Continuous oscillations occur Immediately Immediately Immediately ① System Alarm DL 700M AMP DL 800M AMP UL AMP ON or OFF status of each AMP Oscillation If oscillation occurs continuously, the alarm occurs. DL Input If downlink input power is low, the alarm occurs. 5 seconds 5 seconds Door Open When the door opened, the alarm occurs. Immediately Immediately Product Temperature If the temperature of bottom side is higher than the threshold level, the alarm occurs. 5 seconds 5 seconds ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Otherwise Page 59 / 70 User Manual of SRDR-33-7080-A-FN ② External Alarm Output (NFPA) Donor Antenna Malfunction Service Antenna Malfunction If DC power switch is off for the case of AC and batteries, the alarm occurs. It monitors the device whether it is normal. (If it detects an abnormality, the alarm occurs.) It monitors VSWR status at the port of the device. (If there is failure or no antenna, the alarm occurs.) Loss of Normal AC Power If there is no AC power, the alarm occurs. Power Source Redundancy System Component Malfunction Failure of Battery Charger Low-Battery Capacity If there is battery charger failure, the alarm occurs. If the battery power is below 70%, the alarm occurs. ※ Dwell time to issue: the duration for issuing an alarm ※ Dwell time to clear: the duration for clearing an alarm 5 seconds 5 seconds 1 minute 1 minute 5 minutes 1 minute 5 minutes 1 minute 1 minute 1 minute 1 minute 1 minute 1 minute 1 minute When an alarm occurs, the Alarm Remedy button is blinking in green. When you click the Alarm Remedy button, you can see the detailed information about the alarm. Figure 41. Example of Alarm Remedy ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 60 / 70 User Manual of SRDR-33-7080-A-FN 5.3 Alarm Log 5.3.1 Alarm History Figure 42. System Log From the above system log, alarms in red mean alarms issued, and alarms in blue mean alarms cleared. Messages in black mean the user’s actions. The Responder can store up to 400 logs. When a user wants to save alarms logs, click Export button to save them as files. When a user wants to delete all the logs from the Responder, click Erase button in the bottom. ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 61 / 70 5.3.2 Alarm Mask / Shutdown User Manual of SRDR-33-7080-A-FN Click Alarm Mask / Shutdown button to check or change parameters of alarms as shown below. Figure 43. Alarm Mask / Shutdown Table 21. Description of Terms in the Alarm Mask Item Threshold Mask Shutdown Description If it exceeds the threshold value, the alarm occurs. Display and change the masking of alarms ON/OFF feature of each condition for Power AMP Auto Shutdown ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 62 / 70 User Manual of SRDR-33-7080-A-FN 5.4 Firmware Upgrade It allows users to update firmware or to reset the system. Figure 44. Upgrade / Reset ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 63 / 70 User Manual of SRDR-33-7080-A-FN Appendix 6.1 Environmental Specification Item Value Operating Temperature -30 - 60℃ Cooling Convection Humidity 10 % - 90% condensed Enclosure IP66, NEMA 4 Installation site Indoor & Outdoor Item Value Comments No fan inside Comments FCC Compliance UL NFPA/IFC ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 64 / 70 User Manual of SRDR-33-7080-A-FN 6.2 Radio Frequency Specification Value Item Downlink Uplink 758 – 775 MHz 788 – 805 MHz 851 – 861 MHz 806 – 816 MHz 700 PS +33 dBm (2W) +30 dBm (1W) 800 PS +33 dBm (2W) Frequency Range Composite Output Power Comments composite Passband Gain 65 – 95 dB 65 – 95 dB Passband Ripple ±2.5 dB ±2.5 dB Spurious emission -13 dBm -13 dBm Noise Figure 6 dB 6 dB Group Delay 4.5 – 99 usec 4.5 – 99 usec Maximum RF Input Power with no damage + 10 dBm + 10 dBm Adjustable with 1dB steps Depends on types of filters Per channel Squelch -110 – -60 dBm for UL & DL Adjustable with 1dB steps ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 65 / 70 User Manual of SRDR-33-7080-A-FN 6.3 Digital Filter Specification 6.3.1 Public Safety 700 MHz Band–Selective (Class B) Band-Selective Item Frequency Range Preconfigured Delay Variable Gain Range Downlink Uplink ① 758 – 775 MHz ① 788 – 805 MHz ② 769 – 775 MHz ② 799 – 805 MHz ③ 758 – 768 MHz ③ 788 – 798 MHz ① PS NB + FirstNet (M71) ② PS NB only (M72) ③ FirstNet only (M73) 4.5 us for 758 – 768/ 799 – 805 MHz 6 us for 769 – 775 / 788 – 805 MHz 0 – 10 dB with 1dB Step (attenuation only) Adjustable with 1 dB steps Squelch Comments for -110 – -60 dBm For DL & UL For DL & UL 6.3.2 Public Safety 800 MHz Band –Selective (Class B) Band-Selective Item Frequency Preconfigured Range Delay Variable Gain Range Squelch Downlink Uplink ① 851 – 861 MHz ① 806 – 816 MHz ② 851 – 860 MHz ② 806 – 815 MHz ③ 851 – 854 MHz ③ 806 – 809 MHz 5.5 us 0 – 10 dB with 1dB Steps (attenuation only) Adjustable with 1 dB steps for -110 – -60 dBm ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Comments ① NSPSPAC, SMR, EB (M81) ② NSPSPAC, SMR (M82) ③ NSPSPAC (M83) 60dB @ 1 MHz offset For DL & UL For DL & UL Page 66 / 70 User Manual of SRDR-33-7080-A-FN 6.3.3 Public Safety 700 & 800 MHz Channel–Selective (Class A) Channel Selective Item Downlink Uplink Comments BW of 12.5, 25 KHz Channel Filter Semi-auto Number of any increment can be Channel Manual assigned between 700 & Filter Delay Variable Gain Range Squelch 36 800 bands 15 us 15 us 50dB @ 110KHz offset 33 us 33 us 50dB @ 30KHz offset 50 us 50 us 50dB @ 20KHz offset 99 us 99 us 50dB @ 10KHz offset 0 – 10 dB with 1dB Step (attenuation only) Adjustable with 1 dB steps for -110 – -60 dBm ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Per Channel For DL & UL Per Channel For DL & UL Page 67 / 70 User Manual of SRDR-33-7080-A-FN 6.4 Power Supply Specification Item Power Supply Value AC 100 - 120 VAC DC 48 – 56 VDC Charger Comments 48V-rail charger for lead-acid batteries with State of Charge detection Up to 1.7A Power Consumption Operation Mode • 60℃ • Noncharge state 120 AC 48 VDC Power-Saving Mode Passive DAS (PS 700 & PS 800) < 165W < 150W < 130W Passive DAS (PS 700 or PS 800) < 140 W < 125 W < 110 W Active DAS Mode (PS 700 & PS 800) < 110 W < 95 W < 88 W ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 68 / 70 User Manual of SRDR-33-7080-A-FN 6.5 Mechanical Specification Item Dimensions (HxWxD) Value 530 x 420 x 208 (mm) 20.9 x 16.5 x 8.2 (inches) 630 x 460 x 220 (mm) 24.8 x 18.1 x 9.1 (inches) Volume 12.5 gal Weight 34kg, 75 lb 19” Rack Mount Comments Without bump With bump Without bump Yes Power Port AC Power MS3102 16-10S (3pin) DC Power MS3102 18-10S (2pin) Antenna Port Donor N-Female Donor Coupling Service SMA-Female 30 dB coupled to antenna port N-Female Service Coupling SMA-Female 30 dB coupled to antenna port Active DAS Port 700 DL QMA, Female -5dBm @ maximum 800 DL QMA, Female -5dBm @ maximum 700 UL QMA, Female 800 UL QMA, Female Communications Port Antenna Port – WiFi Ethernet Port SMA, Female RJ-45 port with IP66 Local management terminal SNMP traps 5 Relay outputs Relay Output MS3102 20-29S (17 pin) ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. ① System component malfunction. ② VSWR-antenna malfunction ③ Normal AC power, Loss of normal AC power Page 69 / 70 User Manual of SRDR-33-7080-A-FN ④ Battery charger failure ⑤ Low battery capacity (to 70 percent depletion) – End of the document – ©2017 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 70 / 70
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Hoony Hong Category : Comments : Company : SOLiD USA, Inc. Create Date : 2017:08:17 13:48:41+09:00 Manager : Modify Date : 2017:08:17 13:49:12+09:00 Source Modified : D:20170817044820 Subject : Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08 Metadata Date : 2017:08:17 13:49:12+09:00 Creator Tool : Word용 Acrobat PDFMaker 11 Document ID : uuid:40b8033d-db0f-4ad5-b71c-f2c741033f70 Instance ID : uuid:3588a6d5-3243-4de5-8c5d-91a8699be605 Format : application/pdf Title : Responder User Manual Description : Creator : Hoony Hong Producer : Adobe PDF Library 11.0 Keywords : Page Layout : OneColumn Page Count : 70EXIF Metadata provided by EXIF.tools