SORIN CRM KA351 The Orchestra Plus Link User Manual TABLE OF CONTENTS

SORIN CRM The Orchestra Plus Link TABLE OF CONTENTS

User_manual.pdf

USER MANUALKA 351ORCHESTRA PLUS LINK
  TABLE OF CONTENTS 1. List of symbols .......................................................................................................................................................................................... 2 2. Symbols used in this manual ................................................................................................................................................................... 3 3. Introduction ................................................................................................................................................................................................ 4 4. User Profile................................................................................................................................................................................................. 5 5. Indication .................................................................................................................................................................................................... 6 6. Warnings and precautions ....................................................................................................................................................................... 7 6.1 Safety Precautions .......................................................................................................................................................................... 7 6.2 Precautions for safe operation ...................................................................................................................................................... 7 7. Package contents ...................................................................................................................................................................................... 8 8. Description ................................................................................................................................................................................................. 9 9. Using ORCHESTRA PLUS LINK ............................................................................................................................................................. 10 9.1 Setting-up ORCHESTRA PLUS LINK........................................................................................................................................... 10 9.2 Using the ORCHESTRA PLUS LINK ............................................................................................................................................ 10 9.3 Ensuring stable RF Communication ........................................................................................................................................... 11 9.4 ORCHESTRA PLUS LINK software update ................................................................................................................................. 11 10. ORCHESTRA PLUS LINK basic care ..................................................................................................................................................... 12 11. Maintenance and Recycling ................................................................................................................................................................... 13 11.1. Compatibility ................................................................................................................................................................................. 13 12. Troubleshooting ...................................................................................................................................................................................... 14 13. Technical specifications ......................................................................................................................................................................... 15 14. Declaration of conformity ....................................................................................................................................................................... 16 15. Guidance and manufacturer’s declaration ........................................................................................................................................... 19 15.1 Electromagnetic emissions .......................................................................................................................................................... 19 15.2 Electromagnetic immunity ........................................................................................................................................................... 19 15.3 Recommended separation distances between portable and mobile RF communications equipment and the ORCHESTRA PLUS LINK ............................................................................................................................................................. 20 16. Technical assistance ............................................................................................................................................................................... 21
1.  LIST OF SYMBOLS  2 SORIN - ORCHESTRA PLUS LINK – U386A    1.  LIST OF SYMBOLS                                          FCC ID : YSGKA351 IC ID: 10270A-KA351    This symbol is used to encourage you to consult the documentation and manual enclosed in the packaging. FCC icon This symbol confers the approval of the US Federal Communications Commission.    Name and address of the manufacturer  Serial number     Keep the device dry. Keep it away from liquids and do not spill or drip water on it.  The monitor shall be powered only with direct current.  Non-ionizing magnetic radiation   This electronic product is subject to disposal and recycling regulations that vary by country and region. Many  countries  prohibit  the  disposal  of  waste  electronic  equipment  in  standard  waste receptacles. For more details, please refer to the European Directive 2002/96/CEE.   Temperature limits for storage and transportation   Humidity limits for storage and transportation   Pressure limits for storage and transportation   Sorin Reference of the ORCHESTRA PLUS LINK  USB Type A Power supply connector to Orchestra Plus
2.  SYMBOLS USED IN THIS MANUAL  SORIN – ORCHESTRA PLUS LINK – U386A 3   2.  SYMBOLS USED IN THIS MANUAL  This icon is used to call your attention to a particularly important point.  This icon alerts you to a hazard that may result in equipment damage or personal injury. Carefully read the instructions provided with this icon.  ABOUT THIS MANUAL If you have technical or usage questions that are not covered in this manual or you want more in-depth information, please contact your sales representative.
3.  INTRODUCTION  4 SORIN - ORCHESTRA PLUS LINK – U386A    3.  INTRODUCTION The ORCHESTRA PLUS LINK is part of the RF Programmer System. This system has been specially designed to program and interrogate Sorin Radio Frequency implantable medical devices.  Sorin cardiac devices are equipped with a transceiver which receives clinical commands and sends  clinical  information  and  device  parameters  through  the  ORCHESTRA  PLUS  LINK Radio Frequency wireless technology.    This manual does not explain how to use the SmartView programming software; please refer to the online help.
4.  USER PROFILE  SORIN – ORCHESTRA PLUS LINK – U386A 5   4.  USER PROFILE Any  person  who  followed  the  required  training  based  on  the  local  regulation.  Training completion and effectiveness are under his/her medical supervisor’s responsibility.
5.  INDICATION  6 SORIN - ORCHESTRA PLUS LINK – U386A    5. INDICATION The ORCHESTRA PLUS LINK is designed for use with:  -  Sorin Radio Frequency implantable medical devices,  -  Sorin Orchestra Plus programmer equipped with a Sorin inductive programming head.
6.  WARNINGS AND PRECAUTIONS  SORIN – ORCHESTRA PLUS LINK – U386A 7   6.  WARNINGS AND PRECAUTIONS 6.1 SAFETY PRECAUTIONS Alteration –  Your  ORCHESTRA  PLUS  LINK  and  supplied  accessories  shall  not  be modified,  altered,  or  changed  in  any  way  without  signed  written  permission  from  Sorin. Unauthorized  modification  may  void  the  equipment  authorization  from  the  certified  body (compliance to standards) and compromise system performance. Use only Sorin  supplied accessories. Environmental factors - To reduce the risk of system failure, fire, personal injury, do not expose this appliance to humidity, moisture, extreme temperatures or electrical storms. If the ORCHESTRA PLUS LINK is damaged due to a mechanical shock or liquid, do not plug it in again and call your sales representative. Keep the device dry – Do not spill or drip liquids on it. 6.2 PRECAUTIONS FOR SAFE OPERATION Location – Preferably the ORCHESTRA PLUS LINK should be placed in a stable position as close as possible to the patient. Power supply –  The ORCHESTRA PLUS LINK shall be connected exclusively to one of Sorin Orchestra Plus USB ports. Refer to Orchestra Plus user manual for location of ports E & C (dual ports).  Power supply protection –ORCHESTRA PLUS LINK USB cable shall be routed so it is not likely to be walked on or pinched by items placed on or against it. In addition, USB cable extensions shall not be used to connect ORCHESTRA PLUS LINK to Orchestra Plus. Power supply connection – ORCHESTRA PLUS LINK  USB  cable  shall be plugged into Orchestra PLUS before interrogating the implantable medical device. It will not be possible to establish an RF communication with the  implantable medical device if  the interrogation starts before the ORCHESTRA PLUS LINK has been connected. Power  supply  disconnection  –  You  can  only  remove  power  from  ORCHESTRA  PLUS LINK  by  disconnecting  its  USB  cable  from  Orchestra  Plus.  Always  carefully  disconnect ORCHESTRA PLUS LINK by pulling on the USB plug and not on the cable.  Do  not  remove  the  USB  cable  during  the  Orchestra  Plus  programming  session  of  the implantable medical device. Interferences  –  ORCHESTRA  PLUS  LINK  can  be  subject  to  disturbances  from  other products in the vicinity which emit electromagnetic interference (see Troubleshooting section 10).  Keep  the  space  clear  between  the  ORCHESTRA  PLUS  LINK  and  the  implantable medical device.
7.  PACKAGE CONTENTS  8 SORIN - ORCHESTRA PLUS LINK – U386A    7.  PACKAGE CONTENTS Inside the box you will find ORCHESTRA PLUS LINK and its user manual (CD-Rom).      Do not use any other parts than those supplied with the ORCHESTRA PLUS LINK.
8.  DESCRIPTION  SORIN – ORCHESTRA PLUS LINK – U386A 9   8.  DESCRIPTION  A/ Functioning status LED B/ RF link indicator LED C/ RF signal strength 5 LEDs D/ USB cable    A A  C C B  C D  C
9.  USING ORCHESTRA PLUS LINK  10 SORIN - ORCHESTRA PLUS LINK – U386A    9.  USING ORCHESTRA PLUS LINK  9.1 SETTING-UP ORCHESTRA PLUS LINK In order to setup ORCHESTRA PLUS LINK, follow the instructions below. Step Operation 1 Install & switch on Orchestra Plus programmer (refer to Orchestra Plus user manual) 2 Take ORCHESTRA PLUS LINK out of the box. 3 Place your ORCHESTRA PLUS LINK on a stable and flat surface, (on a trolley, table or the patient’s bed) as close as possible to the patient. 4 Plug ORCHESTRA PLUS LINK USB cable into an Orchestra Plus USB port.   Once connected to Orchestra Plus, ORCHESTRA PLUS LINK will automatically run SW initialization and self-tests for a few seconds (status LED will light-up orange).    Once self-tests have passed, ORCHESTRA PLUS LINK is ready for use. The status LED becomes green. 9.2 USING THE ORCHESTRA PLUS LINK To interrogate an implantable  medical  device compatible  with  ORCHESTRA  PLUS  LINK, follow the instructions below: Step Operation 1 Place the inductive programming head on the implantable medical device and select the Interrogate button in the Programmer User Interface.   After  a  few  seconds  the  RF  communication  will  start  automatically  (if  previously selected in the programmer User Interface) The  RF  link  indicator  will  light-up  and  RF  signal  strength  LEDs  will  indicate the  RF communication quality. 5 LEDs lit up indicate the optimal communication 2 Move the inductive programming head away from the implantable medical device once the RF communication has started  Full  interrogation  and  programming  of  the  implantable  medical  device  can  now  be performed via ORCHESTRA PLUS LINK. 3 Quit the programming session before the patient leaves the operating room or follow-up. RF programming communication will be in any case automatically disabled after a time of inactivity (RF still active for Remote Monitoring).
9.  USING ORCHESTRA PLUS LINK  SORIN – ORCHESTRA PLUS LINK – U386A 11   Quitting  the  programming  session  reduces  battery  consumption  and optimizes device longevity.  9.3 ENSURING STABLE RF COMMUNICATION  For  stable  RF  communication  between  ORCHESTRA  PLUS  LINK  and  the  implantable medical device, it is recommended to position ORCHESTRA PLUS LINK in order to light at least 4 LEDs.    It  is  highly  recommended  to  obtain  stable  communication  before performing device tests such as pacing and defibrillation threshold tests. Keep  the  space  clear  between  the  ORCHESTRA  PLUS  LINK  and  the implantable medical device, and do not cover the implanted device when performing defibrillation threshold tests.  In some cases the RF communication can be disturbed and disrupted (see Troubleshooting section 10). When  RF  communication  is  disrupted  Orchestra  Plus  will  automatically  try  to  restore  it. During RF communication restoration, the RF link LED will blink.     9.4 ORCHESTRA PLUS LINK SOFTWARE UPDATE ORCHESTRA PLUS LINK software update, if any, will start automatically after connection to Orchestra Plus. (Orchestra Plus shall be on.)  During the update the functioning status LED is  green  and  the  RF  signal  strength  LEDs indicate  the  action  in-progress  by  blinking sequentially.
10. ORCHESTRA PLUS LINK BASIC CARE  12 SORIN - ORCHESTRA PLUS LINK – U386A    10. ORCHESTRA PLUS LINK BASIC CARE  Protect the ORCHESTRA PLUS LINK from splashes. To clean it, please only use a soft dry cloth. Any other cleaning method could damage the ORCHESTRA PLUS LINK. Do not use any kind of detergents even dry ones. Do not sterilize.
11. MAINTENANCE AND RECYCLING  SORIN – ORCHESTRA PLUS LINK – U386A 13   11. MAINTENANCE AND RECYCLING 11.1.  COMPATIBILITY For  more  information  about  implant  Radio  Frequency  wireless  programming  compatibility with ORCHESTRA PLUS LINK, please refer to the implant user manual.  The  ORCHESTRA  PLUS  LINK  requires  neither  maintenance,  nor  calibration  (periodical electrical test). As  with  all  electronic  devices,  recycling  the  ORCHESTRA  PLUS  LINK  is  mandatory, therefore please return it to Sorin if no longer used.  Please contact your sales representative for more information on the collection procedure. Sorin will be in charge of collecting and recycling it in compliance with European Directive 2002/96/CEE.
12. TROUBLESHOOTING  14 SORIN - ORCHESTRA PLUS LINK – U386A    12. TROUBLESHOOTING Start-up problems If the ORCHESTRA PLUS LINK functioning status LED is not green, verify USB connection with Orchestra Plus. If the problem persists, call your sales representative.  Unstable or no RF communication with implantable medical device To recover stable communication: -  Verify USB connection with Orchestra Plus -  Move the inductive programming head away from the implantable medical device during the implantation or follow-up session, when the RF session is initiated. -  Remove any objects between ORCHESTRA PLUS LINK and implantable medical device -  Re-position (5 - 10 cm) or rotate the ORCHESTRA PLUS LINK -  Move the ORCHESTRA PLUS LINK closer to the implantable medical device -  If none of the above works, switch to inductive telemetry
13.  TECHNICAL SPECIFICATIONS  SORIN – ORCHESTRA PLUS LINK – U386A 15   13. TECHNICAL SPECIFICATIONS  Part number KA351 Dimensions  Height: 176 mm Width: 106mm Depth: 54,4 mm Weight 450 g Power supply  USB input : 5 V / 500mA  Operating conditions from 0°C to +35°C Atmospheric pressure: from 700 to 1060 hPa  Transport and storage conditions from -20°C to +60°C from 5% to 95% RH (non condensing) Atmospheric pressure: from 500 to 1060 hPa Transmitter frequency 2400-2483 MHz (ISM) 402-405 MHz (MedRadio) Characteristics of the transmitters ISM: uses frequency hopping EIRP = 10 mW max, OOK modulation. MedRadio: uses Listen Before Talk algorithm, EIRP = 25 µW max, FSK modulation. Receiver frequency 402-405 MHz (MedRadio)   The  ORCHESTRA  PLUS  LINK  may  be  disturbed  by  other  equipment, even if said equipment complies with CISPR emission requirements.
14. DECLARATION OF CONFORMITY  16 SORIN - ORCHESTRA PLUS LINK – U386A    14. DECLARATION OF CONFORMITY Sorin declares that this device conforms to the following Product Specifications: Safety  -  IEC  60601-1: 2005  (Ed.  3)  -  Medical  electrical  equipment  -  Part  1:  General requirements for basic safety and essential performance. EMC  -  IEC  60601-1-2:  2012  (Ed.  3)  -  Medical  electrical  equipment  -  Part  1-2:  General requirements  for  basic  safety  and  essential  performance  -  Collateral  standard: Electromagnetic compatibility - Requirements and Tests. EN 50371: 2002 - Generic standard to demonstrate the compliance of low power electronic and  electrical  apparatus  with  the  basic  restrictions  related  to  human  exposure  to electromagnetic fields (10 MHz – 300 GHz). EN 50385: 2002 - Product standard to demonstrate the compliance of radio base stations and  fixed  terminal  stations  for  wireless  telecommunication  systems  with  the  basic restrictions or the reference levels related. EN 60950-1:2006/A12:2011 - Information technology equipment - Safety -- Part 1: General requirements. EN  62311:  2008  -  Assessment  of  electronic  and  electrical  equipment  related  to  human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz) EN 301 489-1 v1.8.1  -  Electromagnetic compatibility  and  Radio  spectrum Matters  (ERM); Electromagnetic  Compatibility (EMC)  standard  for  radio  equipment  and  services  -  Part 1: Common technical requirements. EN 301 489-1 V1.9.2 - Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic  Compatibility  (EMC)  standard  for  radio  equipment  and  services;  Part  1: Common technical requirements EN 301 489-7 V1.3.1 - Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic  Compatibility  (EMC)  standard  for  radio  equipment;  Part  17:  Specific conditions for Broadband Data Transmission Systems EN 301 489-17 v2.1.1 - Specific conditions for Broadband Data Transmission Systems. EN 301 489-27 v1.1.1  -  Specific  conditions  for  Ultra Low Power  Active  Medical  Implants (ULP-AMI) and related peripheral devices (ULP-AMI-P). EN  300  328  v1.7.1  -  Electromagnetic  compatibility  and  Radio  spectrum  Matters  (ERM); Wideband  transmission  systems;  Data  transmission  equipment  operating  in  the  2,4  GHz ISM band and using wide band modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive. ETSI  EN  301  839-1  v1.3.1  -  Electromagnetic  compatibility  and  Radio  spectrum  Matters (ERM); Short Range Devices (SRD); Ultra Low Power Active Medical Implants (ULP-AMI) and Peripherals (ULP-AMI-P) operating in the frequency range 402 MHz to 405 MHz - Part 1: Technical characteristics and test methods. ETSI  EN  301  839-2  v1.3.1  -  Electromagnetic  compatibility  and  Radio  spectrum  Matters (ERM); Short Range Devices (SRD); Ultra Low Power Active Medical Implants (ULP-AMI) and Peripherals (ULP-AMI-P) operating in the frequency range 402 MHz to 405 MHz - Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive.  Federal Communication Commission Interference Statement 47 CFR Section 15 and 105(b)
14. DECLARATION OF CONFORMITY  SORIN – ORCHESTRA PLUS LINK – U386A 17  The FCC product ID is YSGKA351. This equipment has been tested and found to comply with the limits for  a Class  B digital device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a  residential  installation.  This equipment generates uses and can radiate radio frequency energy and, if not installed and used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a particular installation. If this equipment does cause harmful interference to radio or television reception  which  can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is encouraged to try to correct interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept  any  interference  received,  including  interference  that  may  cause  undesired operation. This device complies with FCC RF radiation exposure limits set forth for general population. This  device  must  be  installed  to  provide  a  separation  distance  of  at  least  20cm  from  all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.  FCC Interference Statement 47 CFR Section 15.21 - No Unauthorized Modifications    CAUTION: This equipment may not be modified, altered, or changed in any way  without  signed  written  permission  from  SORIN.  Unauthorized modification may void the equipment authorization from the  FCC and  will void the SORIN warranty.  Identification of the equipment according Section 95.1217(a) This transmitter is authorized by rule under the Medical Device Radiocommunication Service (in part 95 of the FCC Rules) and must not cause harmful interference to stations operating in the 400.150-406.00 MHz band in the Meteorological Aids (i.e., transmitters and receivers used to communicate weather data), the Meteorological Satellite, or the Earth Exploration Satellite  Services  and  must  accept  interference  that  may  be  caused  by  such  stations, including  interference  that  may cause  undesired  operation. This  transmitter shall  be used only in accordance with the FCC Rules governing the Medical Device Radiocommunication Service. Analog and digital voice communications are prohibited. Although this transmitter has been approved by the Federal Communications Commission, there is no guarantee that it will not receive interference or that any particular transmission from this transmitter will be free from interference.  IC Requirements for Canada The IC product ID is 10270A-KA351.
14. DECLARATION OF CONFORMITY  18 SORIN - ORCHESTRA PLUS LINK – U386A   This class B digital apparatus meets all requirements of the Canadian Interference- causing equipment regulations. This device complies with Industry Canada licence-exempt RSS standard(s).  Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under  Industry  Canada  regulations,  this  radio  transmitter  may  only  operate  using  an antenna of a type and maximum (or lesser) gain approved for the  transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should  be  so chosen that  the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This device complies with Industry Canada RF radiation exposure limits set forth for general population (uncontrolled  exposure).  This  device  must be  installed  to  provide a  separation distance  of  at  least  20cm  from  all  persons  and  must  not  be  collocated  or  operating  in conjunction with any other antenna or transmitter.  This device may not interfere with stations operating in the 400.150–406.000 MHz band in the  Meteorological  Aids,  Meteorological  Satellite,  and  Earth  Exploration  Satellite  Services and must accept any interference received, including interference that may cause undesired operation.  Cet appareil numérique de la classe B respecte toutes les exigences du règlement sur le matériel brouilleur du Canada. Le  présent  appareil  est  conforme  aux  CNR  d’Industrie  Canada  applicables  aux  appareils radio  exempts  de  licence.  L’exploitation  est  autorisée aux deux conditions  suivantes:  (1) il ne  doit  pas  produire  de  brouillage,  et  (2) l’utilisateur  du  dispositif  doit  être  prêt  a  accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. Conformément  à  la  réglementation  d’Industrie  Canada,  le  présent  émetteur  radio  peut fonctionner avec une antenne d’un type et  d’un gain maximal (ou  inférieur) approuvé pour l’émetteur  par  Industrie  Canada.  Dans  le  but  de  réduire  les  risques  de  brouillage radioélectrique à l’ intention d’autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Le  présent  appareil  est  conforme  aux  niveaux  limites  d’exigences  d’exposition  RF  aux personnes  définies  par  Industrie  Canada.  Cet  appareil  doit  être  installé  afin  d’offrir  une distance  de  séparation  d’au  moins  20cm  avec  l’utilisateur,  et  ne  doit  pas  être  installé  à proximité ou être utilisé en conjonction avec une autre antenne ou un autre émetteur.  Le présent dispositif ne doit pas causer de brouillage aux stations du service des auxiliaires de la météorologie, des satellites météorologiques, du service d’exploration de la terre par satellite, exploitées dans la bande 400,150-406,000 MHz, et il doit accepter tout brouillage reçu, y compris le brouillage pouvant entraîner un mauvais fonctionnement du dispositif.
15. GUIDANCE AND MANUFACTURER’S DECLARATION  SORIN – ORCHESTRA PLUS LINK – U386A 19   15.  GUIDANCE AND MANUFACTURER’S DECLARATION  15.1 ELECTROMAGNETIC EMISSIONS The  ORCHESTRA  PLUS  LINK  is  intended  for  use  in  the  electromagnetic  environment specified below. The user of the ORCHESTRA PLUS LINK should ensure that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance RF emissions CISPR 11 Group 1 The ORCHESTRA PLUS LINK uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference to nearby electronic equipment. RF emissions CISPR 11 Class B The ORCHESTRA PLUS LINK is suitable for use in all clinical establishments, as an accessory of Orchestra Plus programmer Harmonic emissions IEC 61000-3-2 Class A 15.2 ELECTROMAGNETIC IMMUNITY The  ORCHESTRA  PLUS  LINK  is  intended  for  use  in  the  electromagnetic  environment specified below. The user of the ORCHESTRA PLUS LINK should ensure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Electrostatic discharge (ESD) IEC 61000-4-2 ± 6 kV contact ± 8 kV air ± 6 kV contact ± 8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. The  ORCHESTRA  PLUS  LINK  is  intended  for  use  in  the  electromagnetic  environment specified below. The user of the ORCHESTRA PLUS LINK should ensure that it is used in such an environment. Portable  and  mobile  RF  communications  equipment  should  be  used  no  closer  to  the ORCHESTRA  PLUS  LINK,  including  cables,  than  the  recommended  separation  distance calculated from the equation applicable to the frequency of the transmitter.
15. GUIDANCE AND MANUFACTURER’S DECLARATION  20 SORIN - ORCHESTRA PLUS LINK – U386A   Recommended separation distance: Conducted RF IEC 61000-4-6 3 Vrms 150 kHz  to 80 MHz 3 V Pd 2.1 Radiated RF IEC 61000-4-3 3 V/m 80 MHz  to 2.5 GHz 3 V/m Pd 2.1 80 to 800 MHz Pd 3.2 800 MHz to 2.5 GHz where  P  is  the  maximum  output  power  rating  of  the  transmitter  in  watts  (W)  according  to  the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,a should be less than the compliance level in each frequency range.b Interference may occur in the vicinity of equipment marked with the following symbol:  NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a  Field  strengths  from  fixed  transmitters,  such  as  base  stations  for  radio  (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF  transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the ORCHESTRA PLUS LINK is used exceeds the applicable RF compliance  level  above,  the  ORCHESTRA  PLUS  LINK  should  be  observed  to  verify  normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting, relocating the ORCHESTRA PLUS LINK, or use inductive telemetry. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 15.3 RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS EQUIPMENT AND THE ORCHESTRA PLUS LINK The  ORCHESTRA  PLUS  LINK  is  intended  for  use  in  an  electromagnetic  environment  in which radiated RF disturbances are controlled. The user of the  ORCHESTRA PLUS LINK can help prevent electromagnetic interference by maintaining a minimum distance between portable  and  mobile  RF  communications  equipment  (transmitters)  and  the  ORCHESTRA PLUS  LINK  as  recommended  below,  according  to  the  maximum  output  power  of  the communications equipment. Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz  to 80 MHz Pd 2.1 80 MHz to 800 MHz Pd 2.1 800 MHz to 2.5 GHz Pd 3.2 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
16.  TECHNICAL ASSISTANCE  SORIN – ORCHESTRA PLUS LINK – U386A 21   16.  TECHNICAL ASSISTANCE  For  any  assistance  you  may  need  or  question  you  may  have  about  your  ORCHESTRA PLUS LINK, please call your sales representative.    Last revision date of this manual: 2014-10
Manufactured in italy by distributed bySorin Group Italia S.r.l.Via Crescentino s.n.13040 Saluggia (VC) - ItalyTel: +39 0161 487095Fax: +39 0161 487524Sorin CRM USA, Inc.14401 West 65th WayArvada,CO 80004 - USAwww.sorin.com© 2014 Sorin CRM SASU386ACAUTION: FEDERAL LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN2014-10