  ENGLISH – 1 TABLE OF CONTENTS  1. Introduction.................................................................................5 2. Indication.....................................................................................5 3. Warnings and precautions.........................................................5 3.1. Warnings ...........................................................................5 3.2. Safety Precautions...........................................................6 3.3. Precautions for safe operation .......................................6 4. familiarise yourself with your SMARTVIEW monitor ..............7 4.1. Package contents.............................................................7 4.2. Description........................................................................8 4.3. Meaning of the lights and buttons..................................9 5. Using your SMARTVIEW monitor .............................................10 5.1. Setting-up your SMARTVIEW monitor ...........................10 5.2. Complete the installation with communication setup..................................................................................12 5.3. Operational usage............................................................13 5.4. On-demand operation......................................................13 6. Travelling.....................................................................................13 7. Moving home...............................................................................14 8. SMARTVIEW monitor basic care...............................................14 9. Maintenance and Recycling ......................................................14 10. FAQ ..............................................................................................15 11. Technical specifications ............................................................16 12. Data protection ...........................................................................17 13. Declaration of conformity ..........................................................17
2 – ENGLISH   14. Guidance and manufacturer’s declaration...............................19 14.1. Electromagnetic emissions.............................................19 14.2. Electromagnetic immunity ..............................................20 14.3. Recommended separation distances between portable and mobile RF communications equipment and the SMARTVIEW monitor......................23 15. Technical assistance....................................................................24
  ENGLISH – 3 LIST OF SYMBOLS   This symbol is  used to encourage  you to consult the  documentation  and manual enclosed in the packaging.  This  symbol  confers  the  approval  of  the  US  Federal  Communications Commission.  This symbol indicates that the device meets UL requirements. Remote Cardiac Monitor (Medical Equipment) WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH IEC 60601-1, CAN/CSA 60601-1, ANSI/AAMI ES 60601-1.   Name and address of the manufacturer  Serial number     Temperature limits     Atmospheric air-pressure limits  Direct current   This symbol indicates the phone line connection.
4 – ENGLISH    This electronic product is subject to disposal and recycling regulations that vary by country and region. Many countries prohibit the disposal of waste electronic equipment in standard waste  receptacles.  For  more  details,  please  refer  to  the  European  Directive 2002/96/CEE.  IP21 Degree of protection provided by the enclosure SYMBOLS USED IN THIS MANUAL  This icon is used to call your attention to a particularly important point.  This  icon  alerts  you  to  a  hazard  that  may  result  in equipment  damage  or  personal  injury.  Carefully  read the instructions provided with this icon. ABOUT THIS MANUAL Your doctor should be your first source of information regarding your health. This manual addresses many of the questions you or your family may have about your SMARTVIEW monitor and its use. If you have technical or usage questions that are not covered in this manual or you want more in-depth information, please contact the Sorin CRM toll-free technical assistance.
  ENGLISH – 5 1. INTRODUCTION The SMARTVIEW monitor you received is part of the SMARTVIEW Remote Monitoring  System.  This  system  has  been  specially  designed  to  transmit information  stored  in  your  Sorin  CRM  implanted  cardiac  device  to  your doctor on a regular basis. Your Sorin CRM cardiac device is equipped with a transmitter which sends clinical information and device parameters to your doctor through the SMARTVIEW  monitor using Radio  Frequency wireless technology.  The  data  retrieved  by  your  SMARTVIEW  monitor  is  routed through the phone line, synthesized and reported to your doctor. The SMARTVIEW Remote Monitoring System designed by Sorin CRM is  a  fully  automated  system  which  does  not  need  any  specific interaction in operational mode. It can, however, also be used manually but only on your doctor’s instruction. 2. INDICATION The SMARTVIEW monitor is designed for use with:  − the Sorin CRM radio frequency implanted cardiac device only.  − any  household  traditional  (analog  type)  telephone  land  line.  It  will not operate with other lines such as and not limited to digital, ADSL or optical. 3. WARNINGS AND PRECAUTIONS 3.1. WARNINGS   If at any time you feel that you need a fast response, CALL  YOUR  LOCAL  EMERGENCY  SERVICE IMMEDIATELY.  The  SMARTVIEW  Remote  Monitoring  System  is  not intended as an emergency response system.
6 – ENGLISH   3.2. SAFETY PRECAUTIONS Alteration – Your SMARTVIEW monitor and supplied accessories shall not be modified, altered, or changed in any way without signed written permission  from  SORIN.  Unauthorized  modification  may  void  the equipment  authorization  from  the  FCC  and  will  void  the  SORIN warranty. Use only Sorin CRM supplied accessories. Keep  Children  Away  –  Do  not  let  children  touch  the  SMARTVIEW monitor.  Environmental factors - To reduce the risk of fire, electric shock and personal  injury,  do  not  expose  this  appliance  to  rain,  moisture  or extreme  temperatures  and  avoid  any  installation  or  On-Demand operation  during  an  electrical  storm.  If  the  SMARTVIEW  monitor  is damaged due to a shock or liquid exposure, do not plug it in again and call our toll-free technical assistance. 3.3. PRECAUTIONS FOR SAFE OPERATION Location – Preferably the SMARTVIEW monitor should be placed in a stable position on the nightstand of the patient, as close as possible to the side of the bed the patient usually sleeps. Power  supply  –  The  SMARTVIEW  monitor  should  be  connected exclusively to a Sorin CRM power adaptor. Power supply protection  – Power  adaptors  should  be  routed  so  they are not likely to be walked on or pinched by items placed on or against them.  Power  supply  disconnection  –  The  power  socket  must  be  near  the SMARTVIEW monitor and easily accessible. You can only  remove power from the SMARTVIEW monitor by disconnecting the power adaptor from the outlet. Always carefully disconnect all plugs by pulling on the plug and not on the cord.
  ENGLISH – 7 Interferences  –  The  SMARTVIEW  monitor  can  be  influenced  by  other household appliances (such as alarm clock, mobile phone). If possible, you should avoid placing electrical appliances next to the SMARTVIEW monitor. Check button  - Do not  press the  Check  button  on the bottom  of the transmitter  unless  requested  to  do  so  by  our  toll-free  technical assistance. 4. FAMILIARISE YOURSELF WITH YOUR SMARTVIEW MONITOR 4.1. PACKAGE CONTENTS Inside the box you will find:    1 SMARTVIEW monitor User’s manual     1 Power adaptor   1 RJ11 Telephone cable (5 meters)
8 – ENGLISH    Do not use any other parts than the ones supplied with the  SMARTVIEW  monitor,  as  this  may  result  in increased  emissions  or  decreased  immunity  of  the equipment. 4.2. DESCRIPTION   A/ On-Demand button  B/ Progress bar       C/ Status light D/ Telephone ports 1 and 2  E/ Power supply inlet  (cable with the orange mark)
  ENGLISH – 9 4.3. MEANING OF THE LIGHTS AND BUTTONS Light or button  State  Colour   Meaning  OFF  No colour   The  SMARTVIEW  monitor  is  not properly plugged in or not connected to the  telephone  network.  Please  check the  connections.  If  the  status  light remains off, please contact our toll-free technical assistance. Constant amber You have just connected the SMARTVIEW monitor to the wall socket. The SMARTVIEW monitor is setting up. Please wait. This process takes less than 5 minutes. Status light  ON Constant green The SMARTVIEW monitor is operational. Green  The  SMARTVIEW  monitor  is  gathering data.  Stay  as  close  as  possible  to  the SMARTVIEW  monitor  and  don’t disconnect it. On-Demand button  Flashing Red  The SMARTVIEW monitor could not gather the  information  stored  in  your  implanted defibrillator.  Come  closer  to  the SMARTVIEW  monitor  and  restart  the process. If the button turns red again, please contact our toll-free technical assistance.   ON  Green  You pushed the button to request an On-Demand  transmission.  The  SMARTVIEW monitor  is  checking  that  the  function  is active before performing the transmission.  Progress lights   Progress  Green  The  SMARTVIEW  monitor  is  gathering information  from  your  implanted defibrillator. Stay as close as possible  to  the  SMARTVIEW  monitor  and  don’t disconnect it.
10 – ENGLISH   5. USING YOUR SMARTVIEW MONITOR   The Sorin CRM SMARTVIEW monitor works automatically. Therefore, you will have no interaction with it except at installation and only on your doctor’s request.   5.1. SETTING-UP YOUR SMARTVIEW MONITOR In order to perform the installation of your SMARTVIEW monitor in a quickly, easily and safely way, we recommend you to call our technical assistance (see toll-free phone numbers at the end of this manual). Our technicians will assist you. It is free and takes little time. Step  Operation 1  Take all the items out of the box.  2  Place  your  SMARTVIEW  monitor  in  a  stable  position, preferably on your nightstand, as close as possible to the side of the bed you usually sleep on. 3  To connect the SMARTVIEW monitor to the phone line:
  ENGLISH – 11  wall socket, use the Sorin CRM black telephone cable to connect  the  SMARTVIEW  monitor  to  the  telephone  wall socket as shown in the picture below:   - if your phone is already plugged into the telephone wall socket, unplug your own telephone cable from the telephone wall socket and plug it into one of the telephone ports at the back of the SMARTVIEW monitor. Use the Sorin CRM black telephone cable to connect the SMARTVIEW monitor to the wall socket as shown in the picture below:
12 – ENGLISH   4  Remove the power  adaptor  from  the  little  white  box  and plug  the  end  of  the  cable  with  the  orange  mark  into  the appropriate  inlet  in  the  SMARTVIEW  monitor  identified with the same orange mark. 5  Plug the power supply block into the mains. A green light turns ON immediately on this block. 6  You should observe the following: The status light turns stable amber for around 45 seconds and then turns green. Your SMARTVIEW monitor is now ready for the next step: Communication. 7  The On-Demand button is now flashing green. It will continue flashing as long as you do not press this button.  To  operate  properly,  your  SMARTVIEW  monitor should  always  be  connected  to  your  phone  line  and the main power outlet.  5.2. COMPLETE THE INSTALLATION WITH COMMUNICATION SETUP  At  this  stage,  your  SMARTVIEW  monitor  will  need  to  “talk”  with  your Sorin  CRM  implanted  device.  You  will  not  feel  anything  as  it  is  fully independent of your clinical treatment. Press the On-Demand button gently until you feel a click. You will see the On-Demand button constant green for between 30 seconds and 1 minute. Wait until the green light turns completely OFF. Your  SMARTVIEW  monitor  is  fully  operational  and  your  doctor  has already  been  notified  that  the  installation  has  run  successfully.  Your Sorin CRM implanted device is now being monitored.
  ENGLISH – 13  The  communication  setup  is  requested  at  first installation  only.  Disconnecting  and  reconnecting  the SMARTVIEW monitor does not require setting up the communication again.  5.3. OPERATIONAL USAGE In order to reduce any inconvenience, your SMARTVIEW monitor is set up to read your Sorin CRM implanted device at night while you sleep.  If the status light is OFF, check all connections. If the problem persists, call our toll-free technical assistance..  During the transmission, your phone line will be busy. Should  you  need  to  use  your  phone  for  emergency reasons, temporarily unplug your SMARTVIEW monitor.   Should you be on the phone while the SMARTVIEW monitor gathers  data,  you may hear  some noises or disruptions on the phone line. 5.4. ON-DEMAND OPERATION Your  doctor  may  ask  you  to  press  the  On-Demand  button.  Follow  his instructions closely, but do not use this button unless your doctor requests it. 6. TRAVELLING  If you are  planning to  travel, you should inform your doctor of your  dates of absence. Some of the scheduled events may need to be temporarily changed.   To  know  whether  your  SMARTVIEW  monitor  will operate in the country where you travel,  please call our  toll-free  technical  assistance  who  will  give  you relevant instructions.
14 – ENGLISH   7. MOVING HOME If you move home, you will have to re-install your SMARTVIEW monitor in your new home by following the installation procedure. Please call our toll-free technical assistance. 8. SMARTVIEW MONITOR BASIC CARE  Your  SMARTVIEW  monitor  has  been  designed  to  successfully  pass  the safety and regulatory standards. To ensure that it works, always protect your SMARTVIEW  monitor from  being  splashed  with any kind  of  liquid.  If you need to clean it, please use only a soft dry cloth. Any other cleaning method could  damage  your  SMARTVIEW  monitor.  Do  not  use  any  kind  of detergents even dry ones. 9. MAINTENANCE AND RECYCLING Your SMARTVIEW monitor remains property of Sorin CRM.  It requires no maintenance. As  with  all  electronic  devices  recycling  your  SMARTVIEW  monitor  is mandatory, therefore please return it  to  Sorin  CRM if you  do  not  use  or need it anymore.  Please contact our toll-free technical assistance for more information on the collecting procedure. Sorin CRM will be in charge of collecting and recycling it in compliance with European Directive 2002/96/CEE.
  ENGLISH – 15 10. FAQ Why do I need to be monitored? You have been advised to install Sorin CRM's SMARTVIEW monitor in your home so that your doctor can closely follow your heart disease and identify potential  needs  for  adjustments  to  your  treatment.  Should  you  have  any questions or need further information, please contact your doctor.  What shall I do if I do not feel well? When  experiencing  symptoms,  you  should  call  your  doctor  or  your  local emergency  service.  Our  technology  does  not  replace  them  under  any circumstances. Is there a risk due to Radio Frequency? No,  because  the  SMARTVIEW  monitor  has  successfully  passed  the security tests regarding normative level of radiation. Does the communication cost me anything? The  communication  won’t  cost  you  anything  within  the  country  where the first connection has been initiated.  Our  SMARTVIEW  monitor  uses  toll-free  phone  numbers  to  transfer information to your doctor. If you use the SMARTVIEW Monitor abroad then communication costs will not be covered by Sorin CRM.
16 – ENGLISH   11. TECHNICAL SPECIFICATIONS  If  you  suspect  any  kind  of  default,  please  call  our  toll-free  technical assistance. Our technicians will help you and run investigations if needed. Part number  KA960  Dimensions   Height: 59 mm  Width: 156 mm  Depth: 122 mm  Weight  250 g Power supply   AC input : 100-240 V~ 50-60 Hz 250 mA (to wall socket) Operating conditions  from 0°C to +40°C from 5% to 93% RH non condensing Transport and storage conditions from -15°C to +70°C from 5% to 95% RH non condensing Atmospheric air-pressure limits Min: 700 hPa Max: 1060 hPa IP21  Degree of protection provided by the enclosure Transmitter frequency  2400-2483 MHz (ISM) 402-405 MHz (MedRadio) Characteristics of the transmitters ISM: uses frequency hoping,  ERP = 100 mW max, OOK modulation. MedRadio: uses Listen Before Talk algorithm, ERP = 25 µW max, FSK modulation. Receiver frequency  402-405 MHz (MedRadio)
  ENGLISH – 17 Modem  Standard ITU-T V.92/V.90/56K SocketModem module for PSTN subscriber line. Telecom approved in more than 50 countries.  The SMARTVIEW monitor may be interfered with by other equipment, even if that other equipment complies with CISPR emission requirements. 12. DATA PROTECTION Any clinical data is  fully secured with  restricted  access. You have  the right to access this information at any time and ask for any change by request  only.  Please  contact  your  doctor  or  our  toll-free  technical assistance.  13. DECLARATION OF CONFORMITY Sorin CRM declares that this device: − is  in  conformity  with  the  essential  requirements  of  Directive  1999/5/EC  on  Radio  and Telecommunications  Terminal  Equipment,  with  the  mutual  recognition  of  their  conformity (R&TTE) and with the Directive 90/385/EEC on Active Implantable Medical Devices and, − carries the CE marking accordingly. Sorin CRM declares that this device conforms to the following Product Specifications: Safety  - IEC  60601-1:2005  (Ed.  3)  -  Medical  electrical  equipment  -  Part  1:  General requirements for basic safety and essential performance. EMC -IEC 60601-1-2:2007 (Ed. 3) - Medical electrical equipment - Part 1-2: General requirements for  basic  safety  and  essential  performance  -  Collateral  standard:  Electromagnetic compatibility - Requirements and Tests. EN  50371:2002 - Generic standard  to  demonstrate  the  compliance  of low power  electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz - 300 GHz). EN  50385:2002  -  Product  standard to  demonstrate  the  compliance  of radio  base  stations and fixed terminal stations for wireless telecommunication systems with the basic restrictions or the reference levels related. EN  301  489  v1.8.1  -  Electromagnetic  compatibility  and  Radio  spectrum  Matters  (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services.
18 – ENGLISH   Federal Communication Commission Interference Statement 47 CFR Section 15.105(a) - The FCC Product ID is YSGKA960. This equipment has been tested and found to comply with the limits for a Class B or A digital device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a  residential  installation.  This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.    If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: − Reorient or relocate the receiving antenna. − Increase the separation between the equipment and receiver. − Connect the equipment into an outlet  on  a circuit  different from that to which the receiver is connected. − Consult the dealer or an experienced radio/TV technician for help. FCC Interference Statement 47 CFR Section 15.21 - No Unauthorized Modifications CAUTION:  This  equipment  may  not  be  modified,  altered,  or  changed  in  any  way  without signed written permission from SORIN. Unauthorized modification may void the equipment authorization from the FCC and will void the SORIN warranty. Identification of the equipment according Section 2.925 and 15.19 (a)(1) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1)  This  device  may  not  cause  harmful  interference,  and  (2)  this  device  must accept any interference received, including interference that may cause undesired operation. This device may not interfere with stations operating in the 400.150–406.000 MHz band in the  Meteorological  Aids,  Meteorological  Satellite,  and  Earth  Exploration  Satellite  Services and must accept any interference received, including interference that may cause undesired operation.
  ENGLISH – 19 14. GUIDANCE AND MANUFACTURER’S DECLARATION  14.1. ELECTROMAGNETIC EMISSIONS The SMARTVIEW monitor is intended for use in the electromagnetic environment specified below. The customer or the  user  of  the SMARTVIEW  monitor should assure  that it is used in  such  an environment. Emissions test  Compliance  Electromagnetic environment - guidance RF emissions CISPR 11 Group 1  The SMARTVIEW monitor uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Class B Harmonic emissions IEC 61000-3-2 Class A Voltage fluctuations / flicker emissions IEC 61000-3-3 Complies The SMARTVIEW monitor is suitable for use in all establishments, including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes.
20 – ENGLISH   14.2. ELECTROMAGNETIC IMMUNITY The SMARTVIEW monitor is intended for use in the electromagnetic environment specified below. The user of the SMARTVIEW monitor should assure that it is used in such an environment. Immunity test  IEC 60601 test level Compliance level Electromagnetic environment - guidance Electrostatic discharge (ESD) IEC 61000-4-2 ± 6 kV contact ± 8 kV air ± 6 kV contact ± 8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Electrical fast transient/burst IEC 61000-4-4 ± 2 kV for power supply lines ± 1 kV for input/output lines ± 2 kV for power supply lines ± 1 kV for input/output lines Mains power quality should be that of a typical home environment. Surge IEC 61000-4-5 ± 1 kV line(s) to line(s) ± 2 kV line(s) to earth ± 1 kV line(s) to line(s) ± 2 kV line(s) to earth Mains power quality should be that of a typical home environment.
  ENGLISH – 21 Immunity test  IEC 60601 test level Compliance level Electromagnetic environment - guidance Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5 s <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5 s Mains power quality should be that of a typical home environment. If the user of the SMARTVIEW monitor requires continued operation during power mains interruptions, it is recommended that the SMARTVIEW monitor be powered from an uninterruptible power supply or a battery. Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 3 A/m  3 A/m  Power frequency magnetic fields should be at levels characteristic of a typical bedroom in a typical home environment. NOTE: UT is the a.c. mains voltage prior to application of the test level. The SMARTVIEW monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the SMARTVIEW monitor should assure that it is used in such an environment. Portable  and  mobile  RF  communications  equipment  should  be  used  no  closer  to  the SMARTVIEW  monitor,  including  cables,  than  the  recommended  separation  distance calculated from the equation applicable to the frequency of the transmitter.
22 – ENGLISH   Recommended separation distance: Conducted RF IEC 61000-4-6 3 Vrms 150 kHz  to 80 MHz 3 V Pd 2.1= Radiated RF IEC 61000-4-3 3 V/m 80 MHz  to 2.5 GHz 3 V/m Pd 2.1=  80  to 800 MHz Pd 3.2= 800 MHz to 2.5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field  strengths  from  fixed  RF  transmitters,  as  determined  by  an  electromagnetic  site survey,a should be less than the compliance level in each frequency range.b Interference may occur in the vicinity of equipment marked with the following symbol:  NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a  Field  strengths  from  fixed  transmitters,  such  as  base  stations  for  radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment  due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the SMARTVIEW monitor is used exceeds the applicable RF compliance level above, the SMARTVIEW  monitor  should  be  observed  to  verify  normal  operation.  If  abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the SMARTVIEW monitor. b  Over  the  frequency  range  150 kHz  to  80 MHz,  field  strengths  should  be  less  than 3 V/m.
  ENGLISH – 23 14.3. RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS EQUIPMENT AND THE SMARTVIEW MONITOR The SMARTVIEW monitor is intended for use in an electromagnetic environment in which radiated RF  disturbances  are  controlled.  The  user  of  the  SMARTVIEW  monitor  can  help  prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the SMARTVIEW monitor as recommended below, according to the maximum output power of the communications equipment. Separation distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz Pd 2.1= 80 MHz to 800 MHz Pd 2.1= 800 MHz to 2.5 GHz Pd 3.2= 0.01  0.12  0.12  0.23 0.1  0.38  0.38  0.73 1  1.2  1.2  2.3 10  3.8  3.8  7.3 100  12  12  23 For transmitters  rated at  a  maximum  output power  not listed  above, the  recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency  of  the  transmitter,  where  P  is  the  maximum  output  power  rating  of  the transmitter in watts (W) according to the transmitter manufacturer. NOTE  1:  At  80 MHz  and  800 MHz,  the  separation  distance  for  the  higher  frequency  range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
24 – ENGLISH   15. TECHNICAL ASSISTANCE For any assistance or question you may have about your SMARTVIEW monitor, please call our toll-free Sorin technical assistance. Our technical assistance desk is open from Monday to Friday from 8:00 am to 6:00 pm local time, except weekends.    855 877 3899                   Last revision date of this manual: 2011-07