SOYAL TECHNOLOGY AR-661UGV2 Stationary UHF RFID Reader User Manual AR 661UG brief 1x

SOYAL TECHNOLOGY CO., LTD. Stationary UHF RFID Reader AR 661UG brief 1x

User Manual

Download: SOYAL TECHNOLOGY AR-661UGV2 Stationary UHF RFID Reader User Manual AR 661UG brief  1x
Mirror Download [FCC.gov]SOYAL TECHNOLOGY AR-661UGV2 Stationary UHF RFID Reader User Manual AR 661UG brief  1x
Document ID2752522
Application IDAKlWPPzX0Owt2qDNqJ8W/w==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.28kB (303559 bits)
Date Submitted2015-09-17 00:00:00
Date Available2016-03-16 00:00:00
Creation Date2017-09-14 05:12:12
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-09-14 05:12:12
Document TitleMicrosoft Word - AR-661UG brief user manual-1.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: Timlee

AR-661UG (V2) User Manual
Stationary UHF RFID Reader
Overview
As a long-range stationary radio frequency identification (RFID) reader, the AR-661UG(V2) is
around 860MHz-960MHz (Precise UHF band is able to adjust and comply with different countries’
standard by order) UHF RFID reader operable at various operating bands specified by individual
countries. It also complies with all standard protocols defined in ISO18000-6C.
Points for attention
The reader should be positioned so that personnel in the area for prolonged periods may
safely remain at least 20 cm (8 in) in an uncontrolled environment from the reader’s surface.
Federal Communications Commission (FCC) Statement
15.21
You are cautioned that changes or modifications not expressly approved by the part responsible for
compliance could void the user’s authority to operate the equipment.
15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) this device may not cause harmful interference and
2) this device must accept any interference received, including interference that may cause
undesired operation of the device.
RF exposure:
To comply with the FCC RF exposure compliance requirements, this device and its antenna must not
be co-located or operating in conjunction with any other antenna or transmitter.
FCC RF Radiation Exposure Statement:
1. This Transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
-1-
V150819
AR-661UG (V2) User Manual
Stationary UHF RFID Reader
Contents
UHF Reader*1
L-Bracket*1
U-Bracket*1
Fixed Bracket*1
M6 screw*4
Dimensions
Output Cable Descriptions
-2-
V150819
AR-661UG (V2) User Manual
Stationary UHF RFID Reader
Wire Application
Power
Wire
Color
Black
Orange-White
Orange
Blue-White
Blue
Green-White
Green
DI
Brown-White
DO
Brown
RS-485
GND (WG)
GND (RS-485)
Wiegand
Description
DC Power Jack
Apply for the size in OD55mm*ID20mm*11mm(L)
DC12V / 1.5A
RS-485 (A+)
RS-485
GND for Wiegand Connection
GND for RS-485 Connection
Wiegand Data: 1 Input
Wiegand Data: 0 Input
External control signal input
H:3.3V / L:0V
*If DI is not in use, please connect it with the blue
or blue/white wire.
Reader control signal output
(For RS-485 Connection Only)
Notice of Installation
1. Secure the AR-661UG(V2) RFID reader on a column, pedestal, wall, or beam at least 150cm
above ground and leave space for adjusting the up and down and left and right angles of the
reader.
2. Check the antenna pattern and adjust the support angle for the reader to face the position the tag
will pass through.
3. Although the ideal sensing range of AR-661UG(V2) is over 10m, the actual sensing range varies
due to weather (raining, fog, sunny) and installation method (horizontal, inclining).
Installation
Step 1: Use a screwdriver to screw the
L-Bracket on the backside of UHF reader
Step 2: Take off the nuts and gaskets from
U-bracket. Set the U-bracket into any cylinder at
the site. Gradually attach the Fixed Bracket and
Step 1 to U-Bracket and fixed by the nuts and
gasket.
-3-
V150819
AR-661UG (V2) User Manual
Stationary UHF RFID Reader
Step 3: Adjust the of UHF Reader
Front and back sides of finished Installation
Wiring Diagram
Connect the AR-661UG(V2) to a Wiegand signal source based on the communication interface of the
access controller.
Basic connection with Wiegand interface
Warranty
1. This product is covered by a one-year warranty from the date of purchase.
2. Warranty covers free inspections and repair of the product to good condition if there are problems
or poor product condition.
3. Warranty does not cover product damage due to an act of God (e.g. flood, fire, earthquake,
typhoon, thunder strike, etc.).
4. Warranty does not cover willful damage (e.g. scratch, fall, impact, etc.) or damage due to
negligence (loss, loosened screws, etc.).
Warrant will void if labels on the case are removed or damaged.
-4-
V150819

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Author                          : Timlee
Create Date                     : 2015:08:25 18:27:47+08:00
Modify Date                     : 2015:08:25 18:29:50+08:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : Timlee
Title                           : Microsoft Word - AR-661UG brief user manual-1.docx
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:08:25 18:29:50+08:00
Producer                        : Acrobat Distiller 10.1.15 (Windows)
Document ID                     : uuid:11ecca82-990b-42d6-be98-d860f89ee5e1
Instance ID                     : uuid:32ef9de6-989f-414f-9df0-2d0a33e2f794
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ACLE-AR-661UGV2

Navigation menu