ST Engineering Telematics Wireless SONATA1 Water meter User Manual Master Meter Letter Head

Telematics Wireless Ltd. Water meter Master Meter Letter Head

Users Manual

   _____________________________________________________________________________________    Master Meter, Inc.  101 Regency Pkwy, Mansfield, TX 76063  T: 817-842-8000  F: 817-842-8100  MasterMeter.com         SONATA User Manual FCC ID: NTASONATA1 IC: 4732A-SONATA1 Rev 1.0 November 9, 2016
   _____________________________________________________________________________________    Master Meter, Inc.  101 Regency Pkwy, Mansfield, TX 76063  T: 817-842-8000  F: 817-842-8100  MasterMeter.com   Table of contents  General Information                    Page  1.   Introduction                    3 2.  General Information                  3 3.  Permissible Operating Conditions              3 4.  Package Contents                  3 5.  Accessories (Optional)                  3 6.  Unpacking and Handling                3   Safety                      7.  Transmitter Information                4 8.  FCC and Industry Canada Statements              4   Installation                      9.  Installation Requirements                5 10.  Installing the Sonata                  5   Disposal                      11.  Disposal                    5      2
   _____________________________________________________________________________________    Master Meter, Inc.  101 Regency Pkwy, Mansfield, TX 76063  T: 817-842-8000  F: 817-842-8100  MasterMeter.com    1.  Introduction The Sonata is an ultrasonic water meter designed for accurate measurement of potable water for residential applications. The Sonata's unique design delivers precise flow measurement without any moving parts − for long life, sustained accuracy and exceptional performance. Sonata is a maintenance free device for up to 20 years of operation.   2.  General Information    Read the instructions below before installing the meter.   To  prevent  injury  or  damage,  do  not  install,  operate  or  maintain  the  meter  without  following  the instructions in this guide.   Store the meter in a cool, dry place.   Follow all warnings and instructions marked on the product.  3.  Permissible Operating Conditions  AWWA Standard Most recent revision of ANSI/AWWA Standard C700 and C708 NSF/ANSI Standard NSF/ANSI 372, NSF/ANSI 61, & Safe Drinking Water Act (SDWA) Max. Working Pressure 175 PSI Liquid Temperature 32.1° to 122°F   (0.1° to 50°C) Ambient Temperature -13° to 131°F    (-25° to 55°C) Environmental Protection IP68   4.  Package Contents The following items are included in the package:   Sonata Ultrasonic Water Meter (up to 12 depending on purchased quantity)   Condensed Installation Manual   5.  Accessories – Optional   EDPM gaskets    Non Return Valve    Strainer   Output extension cable, for specific installations.   6.  Unpacking and handling   Carefully unpack the meter and inspect all contents for shipping damage before attempting to install. If any indication of physical damage is found, immediately contact the responsible transportation service and your local Master Meter representative.   Do not carry the Sonata by its lid.   Avoid hard blows, jolts or impact to the meter.    3
   _____________________________________________________________________________________    Master Meter, Inc.  101 Regency Pkwy, Mansfield, TX 76063  T: 817-842-8000  F: 817-842-8100  MasterMeter.com   7.  Transmitter Information  The  User  and  the  Installer  should  be  aware  that  changes  and  modifications  to  the  equipment  not expressly  approved  by  Master  Meter  could  void  warranty  and  the  user's  authority  to  operate  the equipment.   Professionally trained personnel should install the equipment.  The Sonata    is equipped with an internal antenna/transmitter and 1) must be  installed at a  minimum separation distance of at least 20 cm  from all persons, and 2) must not be co-located or  operating in conjunction with any other antenna or transmitter.    8.  FCC and Industry Canada Statements  The digital portion of the transceiver has been tested and found to comply with the limits for a Class B digital  device, pursuant to  part 15  of the  FCC  Rules.  These limits  are designed  to  provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or television  reception,  which  can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is encouraged to try to correct the interference by one or more of the following measures:  1.)  Reorient or relocate the receiving antenna.  2.)  Increase the separation between the equipment and receiver. 3.) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4.) Consult the dealer or an experienced radio/TV technician for help.  FCC and Industry Canada statements This device complies with Part 15 of FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)  This  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired operation.  The device meets the exemption from the routine evaluation limits in section 2.5 of RSS-102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance.     CAUTION ATTENTION 4
   _____________________________________________________________________________________    Master Meter, Inc.  101 Regency Pkwy, Mansfield, TX 76063  T: 817-842-8000  F: 817-842-8100  MasterMeter.com   9.  Installation Requirements 1.  Ensure that the connecting pipes are aligned (Figure 1).   2.  Check for the proper distance between the pipe unions to avoid mechanical stress. (Figure 2)  3.  The meter may be installed in any orientation. (Figure 3) There are no straight pipe requirements on the Sonata.   4.  Always use new gaskets and ensure that the coupling nut surfaces are clean.   Installation Notes   Do not install the meter on the suction side of a pipe.    Avoid exposing the meter to excessive vibration.    Support of the pipeline on both sides of the meter is recommended.   10.  Installing the Sonata 1.  Unpack the Sonata. Install/assemble accessories, is supplied, and as needed.   2.   Note the proper flow direction as indicated on the meter. The Sonata is a bi-directional flow meter and will also measure reverse flow.   3.  Install new gaskets in the coupling nut.   4.  Place the meter in position and carefully tighten the coupling nuts by hand. Make sure each coupling nut is smoothly screwed onto the meter threads. Use a wrench to tighten the coupling nuts to a minimum torque setting of 10 lb-ft up to a maximum of 35 lb-ft. (Figure 4)   5.  Once installed, open the upstream valve to allow water to fill the meter and piping.   6.  Open a downstream valve to flush all air out of the pipeline.   7.  Close the downstream valve and verify that there are no leaks at the coupling nuts.   11.  Disposal This product contains Lithium Thionyl Chloride batteries. Local and national regulations for proper battery disposal should be followed.     Figure 1 Figure 2 Figure 3 Figure 4 5

Navigation menu